1.Specific DNA barcodes screening, germplasm resource identification, and genetic diversity analysis of Platycodon grandiflorum
Xin WANG ; Yue SHI ; Jin-hui MAN ; Yu-ying HUANG ; Xiao-qin ZHANG ; Ke-lu AN ; Gao-jie HE ; Zi-qi LIU ; Fan-yuan GUAN ; Yu-yan ZHENG ; Xiao-hui WANG ; Sheng-li WEI
Acta Pharmaceutica Sinica 2024;59(1):243-252
Platycodonis Radix is the dry root of
2.Study on the potential allergen and mechanism of pseudo-allergic reactions induced by combined using of Reduning injection and penicillin G injection based on metabolomics and bioinformatics
Yu-long CHEN ; You ZHAI ; Xiao-yan WANG ; Wei-xia LI ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Xiao-fei CHEN ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Kun LI ; Jin-fa TANG ; Ming-liang ZHANG
Acta Pharmaceutica Sinica 2024;59(2):382-394
Based on the strategy of metabolomics combined with bioinformatics, this study analyzed the potential allergens and mechanism of pseudo-allergic reactions (PARs) induced by the combined use of Reduning injection and penicillin G injection. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). Based on UPLC-Q-TOF/MS technology combined with UNIFI software, a total of 21 compounds were identified in Reduning and penicillin G mixed injection. Based on molecular docking technology, 10 potential allergens with strong binding activity to MrgprX2 agonist sites were further screened. Metabolomics analysis using UPLC-Q-TOF/MS technology revealed that 34 differential metabolites such as arachidonic acid, phosphatidylcholine, phosphatidylserine, prostaglandins, and leukotrienes were endogenous differential metabolites of PARs caused by combined use of Reduning injection and penicillin G injection. Through the analysis of the "potential allergen-target-endogenous differential metabolite" interaction network, the chlorogenic acids (such as chlorogenic acid, neochlorogenic acid, cryptochlorogenic acid, and isochlorogenic acid A) and
3.Investigation and analysis of the current status of transjugular intrahepatic portosystemic shunt treatment for portal hypertension in China
Haozhuo GUO ; Meng NIU ; Haibo SHAO ; Xinwei HAN ; Jianbo ZHAO ; Junhui SUN ; Zhuting FANG ; Bin XIONG ; Xiaoli ZHU ; Weixin REN ; Min YUAN ; Shiping YU ; Weifu LYU ; Xueqiang ZHANG ; Chunqing ZHANG ; Lei LI ; Xuefeng LUO ; Yusheng SONG ; Yilong MA ; Tong DANG ; Hua XIANG ; Yun JIN ; Hui XUE ; Guiyun JIN ; Xiao LI ; Jiarui LI ; Shi ZHOU ; Changlu YU ; Song HE ; Lei YU ; Hongmei ZU ; Jun MA ; Yanming LEI ; Ke XU ; Xiaolong QI
Chinese Journal of Radiology 2024;58(4):437-443
Objective:To investigate the current situation of the use of transjugular intrahepatic portosystemic shunt (TIPS) for portal hypertension, which should aid the development of TIPS in China.Methods:The China Portal Hypertension Alliance (CHESS) initiated this study that comprehensively investigated the basic situation of TIPS for portal hypertension in China through network research. The survey included the following: the number of surgical cases, main indications, the development of Early-TIPS, TIPS for portal vein cavernous transformation, collateral circulation embolization, intraoperative portal pressure gradient measurement, commonly used stent types, conventional anticoagulation and time, postoperative follow-up, obstacles, and the application of domestic instruments.Results:According to the survey, a total of 13 527 TIPS operations were carried out in 545 hospitals participating in the survey in 2021, and 94.1% of the hospital had the habit of routine follow-up after TIPS. Most hospitals believed that the main indications of TIPS were the control of acute bleeding (42.6%) and the prevention of rebleeding (40.7%). 48.1% of the teams carried out early or priority TIPS, 53.0% of the teams carried out TIPS for the cavernous transformation of the portal vein, and 81.0% chose routine embolization of collateral circulation during operation. Most of them used coils and biological glue as embolic materials, and 78.5% of the team routinely performed intraoperative portal pressure gradient measurements. In selecting TIPS stents, 57.1% of the hospitals woulel choose Viator-specific stents, 57.2% woulel choose conventional anticoagulation after TIPS, and the duration of anticoagulation was between 3-6 months (55.4%). The limitation of TIPS surgery was mainly due to cost (72.3%) and insufficient understanding of doctors in related departments (77.4%). Most teams accepted the domestic instruments used in TIPS (92.7%).Conclusions:This survey shows that TIPS treatment is an essential part of treating portal hypertension in China. The total number of TIPS cases is far from that of patients with portal hypertension. In the future, it is still necessary to popularize TIPS technology and further standardize surgical indications, routine operations, and instrument application.
4.Exploring the risk "time interval window" of sequential medication of Reduning injection and penicillin G injection based on the correlation between biochemical indexes and metabolomics characteristics
Ming-liang ZHANG ; Yu-long CHEN ; Xiao-yan WANG ; Xiao-fei CHEN ; Hui ZHANG ; Ya-li WU ; Liu-qing YANG ; Shu-qi ZHANG ; Lu NIU ; Ke-ran FENG ; Wei-xia LI ; Jin-fa TANG
Acta Pharmaceutica Sinica 2024;59(7):2098-2107
Exploring the risk "time interval window" of sequential medication of Reduning injection (RDN) and penicillin G injection (PG) by detecting the correlation between serum biochemical indexes and plasma metabonomic characteristics, in order to reduce the risk of adverse reactions caused by the combination of RDN and PG. All animal experiments and welfare are in accordance with the requirements of the First Affiliated Experimental Animal Ethics and Animal Welfare Committee of Henan University of Chinese Medicine (approval number: YFYDW2020002). The changes of biochemical indexes in serum of rats were detected by enzyme-linked immunosorbent assay. It was determined that RDN combined with PG could cause pseudo-allergic reactions (PARs) activated by complement pathway. Further investigation was carried out at different time intervals (1.5, 2, 3.5, 4, 6, and 8 h PG+RDN). It was found that sequential administration within 3.5 h could cause significant PARs. However, PARs were significantly reduced after administration interval of more than 4 h. LC-MS was used for plasma metabolomics analysis, and the levels of serum biochemical indicators and plasma metabolic profile characteristics were compared in parallel. 22 differential metabolites showed similar or opposite trends to biochemical indicators before and after 3.5 h. And enriched to 10 PARs-related pathways such as arachidonic acid metabolism, steroid hormone biosynthesis, linoleic acid metabolism, glycerophospholipid metabolism, and tryptophan metabolism. In conclusion, there is a risk "time interval window" phenomenon in the adverse drug reactions caused by the sequential use of RDN and PG, and the interval medication after the "time interval window" can significantly reduce the risk of adverse reactions.
5.Transcutaneous Electrical Acupoint Stimulation Promotes PGC-1α Mediated Mitochondrial Biogenesis and Antioxidant Stress to Protect Cognitive Function in Vascular Dementia Rats
Ji-Liang KANG ; Ke HU ; Jun-Yue LU ; Zi-Wei HU ; Biao-Ping XU ; Xiao-Mao LI ; Jun-Jie ZHOU ; Yu JIN ; Min TANG ; Rong XU ; You-Liang WEN
Progress in Biochemistry and Biophysics 2024;51(5):1191-1202
ObjectiveThe purpose of this study was to investigate the effects of transcutaneous electrical acupoint stimulation (TEAS) on cognitive function of vascular dementia (VD) rats and its mechanism. MethodsVD rat model was established by modified two-vessel occlusion (2-VO). After modeling, TEAS and electroacupuncture (EA) were used to stimulate Baihui and Zusanli points of rats respectively for 14 d. After treatment, novel object recognition test, Morris water maze test, and Y maze test were used to evaluate the spatial memory and learning ability of rats. Hematoxylin and eosin staining was used to observe the morphology of hippocampal neurons. Transmission electron microscopy was used to observe the ultrastructure of hippocampal mitochondria. Enzyme-linked immunosorbent assay kits were used to detected the levels of SOD, CAT, GSH-Px, MDA and ROS in serum of rats. Western blot was used to detect the expression of PGC-1α, TFAM, HO-1, NQO1 proteins in the hippocampus, Keap1 protein in the cytoplasm and Nrf2, NRF1 proteins in the nucleus. ResultsAfter treatment for 14 d, compared to the model group, the escape latency of VD rats decreased, while the discrimination index, the times of rats crossing the original platform area, the residence time in the original platform quadrant, and the percentage of alternation increased. TEAS can improve the structure of hippocampal neurons and mitochondria of VD rats, showing that neurons were arranged more regularly and distributed more evenly, nuclear membrane and nucleoli were clearer, and mitochondrial swelling were reduced, mitochondrial matrix density were increased, and mitochondrial cristae were more obvious. The levels of SOD, GSH-Px and CAT in serum increased significantly, while the concentration of MDA and ROS decreased. TEAS also up-regulated the expression levels of PGC-1α TFAM, NQO1 and HO-1 proteins in the hippocampus and Nrf2, NRF1 proteins in the nucleus, but down-regulated the Keap1 protein in the cytoplasm. ConclusionTEAS can improve cognition, hippocampal neurons and mitochondrial structure of VD rats, and the effect is better than EA. The mechanism may be the activation of PGC-1α mediated mitochondrial biogenesis and antioxidant stress, which also provides a potential therapeutic technology and experimental basis for the treatment of VD.
6.Comparative Evaluation of Encephalon State Index and Bispectral Index in Monitoring the Depth of Anesthesia during the Surgical Anesthesia Stage
Sanchao LIU ; Nong YAN ; Xingliang JIN ; Xianliang HE ; Ke XIAO ; Hanyuan LUO ; Huacheng LUO ; Yongjun ZENG ; Jie QIN ; Yinbing YANG ; Yalan LI ; Lan GAO
Chinese Journal of Medical Instrumentation 2024;48(6):639-644
Objective Evaluate the performance of the encephalon state index(ESI)in depth of anesthesia monitoring during clinical surgery,compared with the bispectral index(BIS).Methods ESI and BIS data were collected from 60 patients in a single-center clinical trial to compare their efficacy in measuring the depth of anesthesia.Results Consistency analysis revealed mean differences and standard deviations of-0.18±5.42 and-0.11±6.51 between ESI and BIS for awake and anesthetized states,respectively.Correlation analysis showed a correlation coefficient of 0.92 throughout the operative period.Prediction probability analysis indicated that both ESI and BIS had prediction probabilities of 0.97,effectively predicting anesthesia status.Conclusion ESI and BIS show good equivalence in monitoring depth of anesthesia during clinical surgery,which meet the requirements of clinical anesthesia.
7.Finite element analysis of titanium rods after vertebral column decancellation osteotomy for ankylosing spondylitis
Bao-Ke SU ; Yong-Qing WANG ; Zhi-Jie KANG ; Hai-Yan WANG ; Feng JIN ; Xiao-He LI ; Zhen-Hua CAO ; Jia-Xuan HUO ; Yong ZHU ; Feng LI
Acta Anatomica Sinica 2024;55(3):339-344
Objective To analyze the stress changes of thoracic vertebra(T)11-sacrum(S)titanium rods in patients with ankylosing spondylitis after vertebral column decancellation(VCD)osteotomy,and provide reference for the selection and improvement of titanium rods before surgery.Methods The original data of the continuous scanning tomographic images of patients with ankylosing spondylitis after VCD osteotomy were imported into Mimics 21.0 in DICOM format,and T11-S vertebrae,screws and titanium rods were respectively reconstructed.They were imported into 3-Matic to establish a preliminary geometric modeling,and then processed with noise removal,paving,smoothing,etc.The improved model was imported into Hypermesh 10 software for grid division,and the material was imported into ANSYS 19.2 to display the finite element model after attribute assignment,Set the boundary and load conditions,and measure the stress value at the connection between the screw and the titanium rod.Results Under neutral position,forward bending,lateral bending,and axial rotation conditions,the titanium rod had the highest stress at the upper vertebrae(T11)and the lowest stress at the top vertebrae(L3);Under the backward extension condition,the titanium rod has the highest stress at the lower end vertebra(L5).Conclusion In the upper and lower vertebrae,it is possible to consider increasing the diameter of the titanium rod,enhancing its hardness,or changing it to a double rod.
8.Cephalometric parameters of three Wa dialect ethnic groups in China
Yue-Tong YAO ; Ke-Li YU ; Xing-Hua ZHANG ; Xin-Ying GAO ; Yao XIAO ; Zhi CHENG ; Wen-Fang GAO ; Xin LIU ; Jin-Ping BAO
Acta Anatomica Sinica 2024;55(5):625-631
Objective To survey and analysis of cephalometric indicators of Wa adults in China.Methods Cephalometric parameters were measured in 1996 cases(858 males and 1138 females)of Wa adults in China,including 927 cases(381 males and 546 females)of the Baraoke ethnic group,564 cases(241 males and 323 females)of the A Wa ethnic group,and 505 cases(236 males and 269 females)of the Wa ethnic group by using sliding caliper and spreading caliper.Seventeen direct cephalofacial parameters and one indirect parameter for each of the three dialect ethnic groups were derived separately and analyzed for age correlations,inter-sex u-tests,and multiple comparisons.Finally,the three dialect ethnic groups were subjected to cluster analysis and principal component analysis with 15 ethnic groups in China.Results Nose breadth,mouth breadth and physiognomic ear length were significantly and positively correlated with age for both sexes in the three Wa dialect ethnic groups,while head breadth and lip height were significantly and negatively correlated with age.Except for the interocular breadth,there were gender differences between males and females in the cephalometric parameters of the three Wa dialect ethnic groups.The cephalofacial features of the Baraoke,A Wa and Wa ethnic groups were different,as evidenced by the fact that males and females of the Baraoke and Wa dialect ethnic group had higher lip height,wider nasal breadth and wider mouth breadth,while males and females of the A Wa ethnic group had lower nasal height.Conclusion The cephalofacial features of the three Wa dialect ethnic groups are close to those of the Khmus and Mang,who have their origins in the ancient Baipu people and are also members of the Mon-Khmer language group of the Austroasiatic linguistic.
9.Modal testing study of three-axis manned centrifuge under elastic boundary conditions
Hai-Xia WANG ; Ke JIANG ; Zhao JIN ; Yi WANG ; Li-Hui ZHANG ; Yan XU ; Cong WANG ; Ming-Hao YANG ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Yuan-Jing ZHENG ; Bao-Hui LI
Chinese Medical Equipment Journal 2024;45(8):38-43
Objective To explore the modal testing method for the three-axis manned centrifuge under elastic boundary conditions with considerations on its complicated structure and high rotational inertia.Methods Modal testing was carried out with a three-axis manned centrifuge under elastic boundary conditions as the subject and a force hammer as the excitation source according to GJB 2706A-2008 Modal tests method for spacecraft and GB/T 11349.3-1992 Experimental determination of mechnical mobility measurements using impact excitation.Four times of hammering were carried out at each excitation position,and the data of the four times of hammering underwent linear average computation.Data acquisition was implemented with a three-axis accelerometer and a 64-channel data collector,and the modal data were analyzed using a frequency response function based on the Test.Lab modal test and analysis software.Results The coherence coefficient of the excitation signal was not lower than 0.8 in the 30 Hz band;the first three orders of the system's intrinsic vibrations were all torsional vibrations,with the frequencies of 9.15,15.66 and 19.22 Hz,respectively;the first order frequency of the system was about 9.15 Hz for both Z18 and Z21 excitation positions,and each of the second and third order frequencies similar situations were observed for also had a roughly equal value for the two excitation positions.Conclusion The force hammer testing method is applicable for the modal testing of the three-axis manned centrifuge,ensuring equipment safety and subject comfort.Referen-ces are provided for the following structural optimization design.[Chinese Medical Equipment Journal,2024,45(8):38-43]
10.Total body water percentage and 3rd space water are novel risk factors for training-related lower extremity muscle injuries in young males
Liang CHEN ; Ke-Xing JIN ; Jing YANG ; Jun-Jie OUYANG ; Han-Gang CHEN ; Si-Ru ZHOU ; Xiao-Qing LUO ; Mi LIU ; Liang KUANG ; Yang-Li XIE ; Yan HU ; Lin CHEN ; Zhen-Hong NI ; Xiao-Lan DU
Chinese Journal of Traumatology 2024;27(3):168-172
Purpose::To identify the risk factors for training-related lower extremity muscle injuries in young males by a non-invasive method of body composition analysis.Methods::A total of 282 healthy young male volunteers aged 18 -20 years participated in this cohort study. Injury location, degree, and injury rate were adjusted by a questionnaire based on the overuse injury assessment methods used in epidemiological studies of sports injuries. The occurrence of training injuries is monitored and diagnosed by physicians and treated accordingly. The body composition was measured using the BodyStat QuadScan 4000 multifrequency Bio-impedance system at 5, 50, 100 and 200 kHz to obtain 4 impedance values. The Shapiro-Wilk test was used to check whether the data conformed to a normal distribution. Data of normal distribution were shown as mean ± SD and analyzed by t-test, while those of non-normal distribution were shown as median (Q 1, Q 3) and analyzed by Wilcoxon rank sum test. The receiver operator characteristic curve and logistic regression analysis were performed to investigate risk factors for developing training-related lower extremity injuries and accuracy. Results::Among the 282 subjects, 78 (27.7%) developed training injuries. Lower extremity training injuries revealed the highest incidence, accounting for 23.4% (66 cases). These patients showed higher percentages of lean body mass ( p = 0.001), total body water (TBW, p=0.006), extracellular water ( p=0.020) and intracellular water ( p=0.010) as well as a larger ratio of basal metabolic rate/total weight ( p=0.006), compared with those without lower extremity muscle injuries. On the contrary, the percentage of body fat ( p=0.001) and body fat mass index ( p=0.002) were lower. Logistic regression analysis showed that TBW percentage > 65.35% ( p=0.050, odds ratio =3.114) and 3rd space water > 0.95% ( p=0.045, odds ratio =2.342) were independent risk factors for lower extremity muscle injuries. Conclusion::TBW percentage and 3rd space water measured with bio-impedance method are potential risk factors for predicting the incidence of lower extremity muscle injuries in young males following training.

Result Analysis
Print
Save
E-mail