1.Analysis of current situation and countermeasures of sex education in special education schools in Luzhou
Chinese Journal of School Health 2025;46(6):802-805
		                        		
		                        			Objective:
		                        			To analyze the implementation status and challenges of sex education in special education schools, so as to provide a scientific basis for formulating effective promotion strategies.
		                        		
		                        			Methods:
		                        			From November 2023 to January 2024, a census survey was conducted among 120 in service teachers from 7 special education schools in Luzhou. The questionnaire covered the current status of sex education in schools, teachers  attitudes and knowledge toward sex education, and their coping methods for students  inappropriate sexual behaviors.
		                        		
		                        			Results:
		                        			About 77.5% of teachers reported having provided sex education to students, but 93.2% indicated a lack of specialized sex education textbooks for special children, 90.4% reported no full time teachers for sex education, and the methods of sex education were relatively limited (50.0% mainly based on lecture method). Nearly 95.8% of teachers held a positive attitude toward sex education, with 98.3% supporting its implementation. Only 26.7% of teachers demonstrated a good grasp of sex education knowledge, with the best understood topic being "recognition and protection of private parts" (21.6%). When dealing with students  inappropriate sexual behaviors, the active response rate of teachers was 23.9%, with the highest active response rate observed for "intentionally hugging or kissing the opposite sex" (39.7%).
		                        		
		                        			Conclusions
		                        			The special education schools in Luzhou lack comprehensive sex education curricula, teaching materials and full time teachers, sufficient knowledge among teachers, and adequate proactive responses to students  inappropriate sexual behaviors. Greater emphasis should be placed on sex education for special children, including the training of dedicated teachers, to provide comprehensive and high quality sex education services for special children.
		                        		
		                        		
		                        		
		                        	
2.Effects of Rhizosphere Organic Acids on Metabolism of Hairy Roots of Salvia miltiorrhiza
Xinyu FU ; Wenying HAN ; Jidong JU ; Bingqian ZHOU ; Guohong YANG ; Xiao WANG ; Lanping GUO ; Wei LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(18):166-174
		                        		
		                        			
		                        			ObjectiveTo investigate the effects of rhizosphere organic acids secreted by the roots of Salvia miltiorrhiza on continuous cropping obstacles. MethodsThe mixed solution of organic acids in the rhizosphere of S. miltiorrhiza in continuous cropping and rotation cropping was added to the hairy roots subcultured for 21 days, and samples were collected on days 0, 2, 4, 6, 8, and 10. The changes of biomass, effective components, primary metabolites, secondary metabolites, antioxidant enzymes, and hormones in hairy roots of S. miltiorrhiza were observed and determined. ResultsCompared with the rotation cropping group and the blank control group, the simulation of organic acid secretion from the roots of S. miltiorrhiza had a significant inhibitory effect on the growth of hairy roots and decreased the content of effective components as well as total sugar and total protein in primary metabolites. Compared with the blank control group, the rotation cropping group and the continuous cropping group showed total sugar and total protein content decreases of 33.9% and 5.1%, respectively. On the other hand, the secretion of organic acids from S. miltiorrhiza roots significantly promoted the accumulation of total phenolic acids and total tanshinone, which showed increases of 14.6% and 1.6%, respectively, in continuous cropping group and rotation cropping group compared with the blank control group. ConclusionThe organic acid environment under continuous cropping significantly inhibited the growth of hairy roots and the accumulation of primary metabolites, while promoting the synthesis and accumulation of secondary metabolites of S. miltiorrhiza. 
		                        		
		                        		
		                        		
		                        	
3.Field-driven medical micro-robots:application prospect of continuously optimizing material preparation process
Wenqian XIAO ; Hongjuan HAN ; Haocheng YANG ; Bo LI ; Binyan HE
Chinese Journal of Tissue Engineering Research 2025;29(10):2097-2104
		                        		
		                        			
		                        			BACKGROUND:Micro-robots have the characteristics of small size,flexibility,and strong targeting,and can complete complex tasks in a single or clustered manner in a narrow environment.With the continuous optimization of materials,preparation processes,and driving approaches,they have shown increasingly important application value in the field of biomedicine. OBJECTIVE:To analyze the application of field-driven micro-robots in medical field and to look forward to their application prospect. METHODS:Using"microrobots,nanorobots,drivers,biomedical,medical"as Chinese keywords and"microrobots,micro-robots,nanorobots,micromachine,microswimmer,medical"as English keywords,WanFang Data and PubMed databases were searched,respectively.The search time range was from January 2010 to January 2024,and a small number of long-term articles were included.Through reading the titles and preliminarily screening the abstracts,the repetitive studies,low-quality journals,and irrelevant literature were excluded.After reading the entire text,66 papers were finally included for review. RESULTS AND CONCLUSION:Field-driven medical micro-robots mainly include magnetic,optical,thermal,ultrasonic,and multi-mixed factor-driven robots.Field-driven robots have been used in intestinal diagnosis,drug targeting therapy,and stem cell therapy.Medical micro-robots are currently only used in a small number of clinical applications,but most of which are still in the theoretical and experimental stages.Medical micro-robots will face many challenges in future,such as large-scale preparation,precise control of micro-robots,recycling or degradation in vivo,whether the materials used will cause adverse reactions to the human body,and the related minimally invasive medical procedures.
		                        		
		                        		
		                        		
		                        	
		                				4.Five new triterpenoid saponins from the kernels of Momordica cochinchinensis 
		                			
		                			Ru DING ; Jia-qi WANG ; Yi-yang LUO ; Yong-long HAN ; Xiao-bo LI ; Meng-yue WANG
Acta Pharmaceutica Sinica 2025;60(2):442-448
		                        		
		                        			
		                        			 Five saponins were isolated from the kernels of 
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
10.Construction, screening and immunogenicity of the recombinant poxvirus vaccine rVTTδTK-RBD against SARS-CoV-2.
Renshuang ZHAO ; Yilong ZHU ; Chao SHANG ; Jicheng HAN ; Zirui LIU ; Zhiru XIU ; Shanzhi LI ; Yaru LI ; Xia YANG ; Xiao LI ; Ningyi JIN ; Xin JIN ; Yiquan LI
Chinese Journal of Cellular and Molecular Immunology 2024;40(1):19-25
		                        		
		                        			
		                        			Objective To construct a recombinant poxvirus vector vaccine, rVTTδTK-RBD, and to evaluate its safety and immunogenicity. Methods The receptor-binding domain (RBD) gene was synthesized with reference to the gene sequence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and was inserted into the polyclonal site of the self-constructed recombinant plasmid pSTKE, to construct the recombinant poxvirus shuttle vector pSTKE-RBD. This was then transfected into BHK-21 cells pre-infected with the vaccinia virus Tiantan strain (VTT). The recombinant poxvirus rVTTδTK-RBD was successfully obtained after several rounds of fluorescence phage screening. The effect of rVTTδTK-RBD on the body mass of BALB/c mice was detected after immunizing mice by intra-nasal vaccination. The levels of specific and neutralizing antibodies produced by rVTTδTK-RBD on BALB/c mice were analyzed after immunizing mice intramuscularly. The effect of rVTTδTK-RBD on T cell subsets in BALB/c mice was detected by flow cytometry. Results Through homologous recombination, enhanced green fluorescent protein (EGFP) screening marker, and multiple rounds of fluorescent phosphorescence phage screening, a recombinant poxvirus rVTTδTK-RBD, expressing RBD with deletions in the thymidine kinase (TK) gene, was successfully obtained, which was validated by PCR. The in vivo experiments on BALB/c mice showed that rVTTδTK-RBD was highly immunogenic against SARS-CoV-2 and significantly reduced toxicity to the body compared to the parental strain VTT. Conclusion The recombinant poxvirus vaccine rVTTδTK-RBD against SARS-CoV-2 is successfully constructed and obtained, with its safety and immunogenicity confirmed through various experiments.
		                        		
		                        		
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Mice
		                        			;
		                        		
		                        			SARS-CoV-2/genetics*
		                        			;
		                        		
		                        			COVID-19
		                        			;
		                        		
		                        			Vaccines, Synthetic/genetics*
		                        			;
		                        		
		                        			Genes, Reporter
		                        			;
		                        		
		                        			Bacteriophages
		                        			;
		                        		
		                        			Mice, Inbred BALB C
		                        			
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail