1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Role of TGF-β/Smads signaling pathway in myocardial fibrosis of heart failure and research status of traditional Chinese medicine intervention
Yao-Hui HUO ; Jing ZHANG ; Li-Rong ZHOU ; Xiao-Gang ZHANG ; Yong-Ze GAO ; Li-Ming LIU ; Kai LIU
The Chinese Journal of Clinical Pharmacology 2024;40(3):444-448
During the progression of heart failure(HF),abnormal transduction of the transforming growth factor-β(TGF-β)/Smads signaling pathway is important mechanism of myocardial fibrosis(MF)in HF.TGF-β,a key factor in MF,is in an overexpression state in the process of MF in HF,and Smads is a major effector downstream of TGF-β.The TGF-β/Smads pathway induces abnormal proliferation of myofibroblasts,aggravates myocardial extracellular matrix deposition,and reduces the ability of the cardiac tissues to resist fibrosis,which plays a complex role in the pathogenesis of MF in HF.Traditional Chinese medicine(TCM)has the efficacy of unequivocal inhibiting myocardial collagen deposition,anti-MF,protecting the myocardium and improving cardiac function in the prevention and treatment of MF in HF and so on,and the TGF-β/Smads pathway is one of the key pathways through which TCM monomers,TCM combinations,and proprietary medicines can exert their cardioprotective effects on the HF.This paper reviews the existing experimental research results of TCM intervening in the TGF-β/Smads pathway for the treatment of MF in HF over the past 10 years,with a view to providing theoretical basis for the prevention and treatment of HF MF well as the development and of new drugs.
7.Modeling of medical equipment requirements for helicopter evacuation and rescue team based on AnyLogic
Shuo TANG ; Mi LI ; Li HE ; Bang-Fu ZHOU ; Liang ZHOU ; Nan XIAO ; Zhi-Gang ZHANG
Chinese Medical Equipment Journal 2024;45(5):28-33
Objective To provide references for reasonable equipping of airborne medical equipment oriented to different tasks by constructing a medical equipment requirement model for the helicopter evacuation and rescue team.Methods Relevant basic data were collected and organized on time for routine and emergency medical treatment and elementary medical equipment requirements for types of medical treatment.AnyLogic multi-agent modeling was used to established a medical equipment requirement model for the helicopter evacuation and rescue team,with the casualty,equipment and medical personnel as the agent modules and the logical relationship-based access rules between the agents.An example was taken with a Z-8 helicopter transformed into an ambulance platform to transport the rescue team and casualties,in which a variety of evacuation tasks with multi combinations of light and serious casualties were simulated and the model developed was used to record and analyze the data on waiting time for medical treatment,completion rate,personnel utilization rate and equipment requirement during 100 times of simulation flight.Results The model developed could provide generalized medical equipment allocation programs for the helicopter evacuation and rescue team to complete a variety of evacuation tasks in terms of electronic device,treatment equipment,auxiliary instrument and medical consumables.Conclusion The model developed facilitates rational allocation of medical equipment for the helicopter evacuation and rescue team.[Chinese Medical Equipment Journal,2024,45(5):28-33]
8.Total body water percentage and 3rd space water are novel risk factors for training-related lower extremity muscle injuries in young males
Liang CHEN ; Ke-Xing JIN ; Jing YANG ; Jun-Jie OUYANG ; Han-Gang CHEN ; Si-Ru ZHOU ; Xiao-Qing LUO ; Mi LIU ; Liang KUANG ; Yang-Li XIE ; Yan HU ; Lin CHEN ; Zhen-Hong NI ; Xiao-Lan DU
Chinese Journal of Traumatology 2024;27(3):168-172
Purpose::To identify the risk factors for training-related lower extremity muscle injuries in young males by a non-invasive method of body composition analysis.Methods::A total of 282 healthy young male volunteers aged 18 -20 years participated in this cohort study. Injury location, degree, and injury rate were adjusted by a questionnaire based on the overuse injury assessment methods used in epidemiological studies of sports injuries. The occurrence of training injuries is monitored and diagnosed by physicians and treated accordingly. The body composition was measured using the BodyStat QuadScan 4000 multifrequency Bio-impedance system at 5, 50, 100 and 200 kHz to obtain 4 impedance values. The Shapiro-Wilk test was used to check whether the data conformed to a normal distribution. Data of normal distribution were shown as mean ± SD and analyzed by t-test, while those of non-normal distribution were shown as median (Q 1, Q 3) and analyzed by Wilcoxon rank sum test. The receiver operator characteristic curve and logistic regression analysis were performed to investigate risk factors for developing training-related lower extremity injuries and accuracy. Results::Among the 282 subjects, 78 (27.7%) developed training injuries. Lower extremity training injuries revealed the highest incidence, accounting for 23.4% (66 cases). These patients showed higher percentages of lean body mass ( p = 0.001), total body water (TBW, p=0.006), extracellular water ( p=0.020) and intracellular water ( p=0.010) as well as a larger ratio of basal metabolic rate/total weight ( p=0.006), compared with those without lower extremity muscle injuries. On the contrary, the percentage of body fat ( p=0.001) and body fat mass index ( p=0.002) were lower. Logistic regression analysis showed that TBW percentage > 65.35% ( p=0.050, odds ratio =3.114) and 3rd space water > 0.95% ( p=0.045, odds ratio =2.342) were independent risk factors for lower extremity muscle injuries. Conclusion::TBW percentage and 3rd space water measured with bio-impedance method are potential risk factors for predicting the incidence of lower extremity muscle injuries in young males following training.
9.Reconstruction of Allen's type IV fingertip amputation via bilateral unequal-sized hallux osteo-onychocutaneous free flaps: A retrospective study with 5-year follow-up
Xiu-Zhong LI ; Xiu-Yun WANG ; Yi-Min ZHOU ; Da-Zhi YU ; Hua-Gang ZHANG ; Shu-Jian HOU ; Ke-Cheng LAO ; Xiao FAN
Chinese Journal of Traumatology 2024;27(6):403-409
Purpose::The reconstruction of Allen's type IV fingertip amputation is a clinical challenge. Our team designed bilateral unequal-sized hallux osteo-onychocutaneous free flaps for the long-term reconstruction of Allen's type IV fingertip amputation and conducted a retrospective study with a 5-year follow-up aims to evaluate the effects of this technique.Methods::A retrospective analysis with a 5-year follow-up including 13 patients with Allen's type IV fingertip amputation who were admitted to our hospital from January 2010 to January 2017 was conducted. The patients were treated with bilateral unequal-sized hallux osteo-onychocutaneous free flaps. The operation time, intraoperative blood loss, and complications were recorded, and the survival rate of the transplanted flaps was calculated. During the 5-year follow-up after operation, the nail growth time was recorded and the finger appearance was observed. At the last follow-up appointment, the length, width, and girth of the reconstructed fingertip and contralateral normal fingertip, range of motion of the reconstructed fingertip and contralateral normal fingertip, Semmes-Weinstein test (for the evaluation of tactile sensation), and two-point discrimination testing results were recorded. SPSS 22.0 software was used for the statistical analysis and the data are presented as mean ± SD.Results::The mean operation time was (5.62 ± 0.51) h, the mean intraoperative blood loss was (34.15 ± 3.13) mL, and the survival rate of the transplanted flaps was 100%. During the 5-year follow-up, the average nail growth time was (10.14 ± 1.98) months and the average bone union time was (3.78 ± 0.91) months. The length, width, and girth of the reconstructed fingertip were (31.52 ± 3.73) mm, (17.82 ± 1.74) mm, and (59.75 ± 3.04) mm, respectively, which did not differ from those of the contralateral normal fingertip. The range of motion of the reconstructed fingertip was (12.15 ± 2.79) degrees which is different from that of the contralateral normal fingertip. The average tactile sensation evaluated via the Semmes-Weinstein test and the average two-point discrimination test of the reconstructed fingertip were (0.39 ± 0.17) g and (7.46 ± 1.14) mm, respectively, which were not different from those of the contralateral normal fingertip. The average Maryland score of feet in the donor area was 87.66 ± 7.39, which was satisfactory.Conclusion::Bilateral unequal-sized hallux osteo-onychocutaneous free flaps are an effective method to reconstruct Allen's type IV fingertip amputations with a satisfactory appearance and good sensory function.
10.Surveillance of bacterial resistance in tertiary hospitals across China:results of CHINET Antimicrobial Resistance Surveillance Program in 2022
Yan GUO ; Fupin HU ; Demei ZHU ; Fu WANG ; Xiaofei JIANG ; Yingchun XU ; Xiaojiang ZHANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Yuling XIAO ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Jingyong SUN ; Qing CHEN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yunmin XU ; Sufang GUO ; Yanyan WANG ; Lianhua WEI ; Keke LI ; Hong ZHANG ; Fen PAN ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Wei LI ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Qian SUN ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanqing ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Wenhui HUANG ; Juan LI ; Quangui SHI ; Juan YANG ; Abulimiti REZIWAGULI ; Lili HUANG ; Xuejun SHAO ; Xiaoyan REN ; Dong LI ; Qun ZHANG ; Xue CHEN ; Rihai LI ; Jieli XU ; Kaijie GAO ; Lu XU ; Lin LIN ; Zhuo ZHANG ; Jianlong LIU ; Min FU ; Yinghui GUO ; Wenchao ZHANG ; Zengguo WANG ; Kai JIA ; Yun XIA ; Shan SUN ; Huimin YANG ; Yan MIAO ; Mingming ZHOU ; Shihai ZHANG ; Hongjuan LIU ; Nan CHEN ; Chan LI ; Jilu SHEN ; Wanqi MEN ; Peng WANG ; Xiaowei ZHANG ; Yanyan LIU ; Yong AN
Chinese Journal of Infection and Chemotherapy 2024;24(3):277-286
Objective To monitor the susceptibility of clinical isolates to antimicrobial agents in tertiary hospitals in major regions of China in 2022.Methods Clinical isolates from 58 hospitals in China were tested for antimicrobial susceptibility using a unified protocol based on disc diffusion method or automated testing systems.Results were interpreted using the 2022 Clinical &Laboratory Standards Institute(CLSI)breakpoints.Results A total of 318 013 clinical isolates were collected from January 1,2022 to December 31,2022,of which 29.5%were gram-positive and 70.5%were gram-negative.The prevalence of methicillin-resistant strains in Staphylococcus aureus,Staphylococcus epidermidis and other coagulase-negative Staphylococcus species(excluding Staphylococcus pseudintermedius and Staphylococcus schleiferi)was 28.3%,76.7%and 77.9%,respectively.Overall,94.0%of MRSA strains were susceptible to trimethoprim-sulfamethoxazole and 90.8%of MRSE strains were susceptible to rifampicin.No vancomycin-resistant strains were found.Enterococcus faecalis showed significantly lower resistance rates to most antimicrobial agents tested than Enterococcus faecium.A few vancomycin-resistant strains were identified in both E.faecalis and E.faecium.The prevalence of penicillin-susceptible Streptococcus pneumoniae was 94.2%in the isolates from children and 95.7%in the isolates from adults.The resistance rate to carbapenems was lower than 13.1%in most Enterobacterales species except for Klebsiella,21.7%-23.1%of which were resistant to carbapenems.Most Enterobacterales isolates were highly susceptible to tigecycline,colistin and polymyxin B,with resistance rates ranging from 0.1%to 13.3%.The prevalence of meropenem-resistant strains decreased from 23.5%in 2019 to 18.0%in 2022 in Pseudomonas aeruginosa,and decreased from 79.0%in 2019 to 72.5%in 2022 in Acinetobacter baumannii.Conclusions The resistance of clinical isolates to the commonly used antimicrobial agents is still increasing in tertiary hospitals.However,the prevalence of important carbapenem-resistant organisms such as carbapenem-resistant K.pneumoniae,P.aeruginosa,and A.baumannii showed a downward trend in recent years.This finding suggests that the strategy of combining antimicrobial resistance surveillance with multidisciplinary concerted action works well in curbing the spread of resistant bacteria.

Result Analysis
Print
Save
E-mail