1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.A reporter gene assays for bioactivity determination of human chorinonic gonadotropin
Ying HUANG ; Xiao-ming ZHANG ; He-yang LI ; Lü-yin WANG ; Hui ZHANG ; Ping LÜ ; Jing LI ; Xiang-dong GAO ; Cheng-gang LIANG
Acta Pharmaceutica Sinica 2024;59(2):432-438
This study constructed a LHCGR-CRE-luc-HEK293 transgenic cell line according to the activation of the cAMP signaling pathway after recombinant human chorionic gonadotropin binding to the receptor. The biological activity of recombinant human chorionic gonadotropin was assayed using a luciferase assay system. The relative potency of the samples was calculated using four-parameter model. And the method conditions were optimized to validate the specificity, relative accuracy, precision and linearity of the method. The results showed that there was a quantitative potency relationship of human chorinonic gonadotropin (hCG) in the method and it was in accordance with the four-parameter curve. After optimization, the conditions were determined as hCG dilution concentration of 2.5 μg·mL-1, dilution ratio of 1∶4, cell number of 10 000-15 000 cells/well, and induction time of 6 h. The method had good specificity, relative accuracy with relative bias ranging from -8.9% to 3.4%, linear regression equation correlation coefficient of 0.996, intermediate precision geometric coefficient of variation ranging from 3.3% to 15.0%, and linearity range of 50% to 200%. This study successfully established and validated a reporter gene method to detect hCG biological activity, which can be used for hCG biological activity assay and quality control.
7.Total body water percentage and 3rd space water are novel risk factors for training-related lower extremity muscle injuries in young males
Liang CHEN ; Ke-Xing JIN ; Jing YANG ; Jun-Jie OUYANG ; Han-Gang CHEN ; Si-Ru ZHOU ; Xiao-Qing LUO ; Mi LIU ; Liang KUANG ; Yang-Li XIE ; Yan HU ; Lin CHEN ; Zhen-Hong NI ; Xiao-Lan DU
Chinese Journal of Traumatology 2024;27(3):168-172
Purpose::To identify the risk factors for training-related lower extremity muscle injuries in young males by a non-invasive method of body composition analysis.Methods::A total of 282 healthy young male volunteers aged 18 -20 years participated in this cohort study. Injury location, degree, and injury rate were adjusted by a questionnaire based on the overuse injury assessment methods used in epidemiological studies of sports injuries. The occurrence of training injuries is monitored and diagnosed by physicians and treated accordingly. The body composition was measured using the BodyStat QuadScan 4000 multifrequency Bio-impedance system at 5, 50, 100 and 200 kHz to obtain 4 impedance values. The Shapiro-Wilk test was used to check whether the data conformed to a normal distribution. Data of normal distribution were shown as mean ± SD and analyzed by t-test, while those of non-normal distribution were shown as median (Q 1, Q 3) and analyzed by Wilcoxon rank sum test. The receiver operator characteristic curve and logistic regression analysis were performed to investigate risk factors for developing training-related lower extremity injuries and accuracy. Results::Among the 282 subjects, 78 (27.7%) developed training injuries. Lower extremity training injuries revealed the highest incidence, accounting for 23.4% (66 cases). These patients showed higher percentages of lean body mass ( p = 0.001), total body water (TBW, p=0.006), extracellular water ( p=0.020) and intracellular water ( p=0.010) as well as a larger ratio of basal metabolic rate/total weight ( p=0.006), compared with those without lower extremity muscle injuries. On the contrary, the percentage of body fat ( p=0.001) and body fat mass index ( p=0.002) were lower. Logistic regression analysis showed that TBW percentage > 65.35% ( p=0.050, odds ratio =3.114) and 3rd space water > 0.95% ( p=0.045, odds ratio =2.342) were independent risk factors for lower extremity muscle injuries. Conclusion::TBW percentage and 3rd space water measured with bio-impedance method are potential risk factors for predicting the incidence of lower extremity muscle injuries in young males following training.
8.Association of abnormal early postoperative blood glucose concentration with short-term prognosis and establishment of a prediction model in patients undergoing non-small cell lung cancer surgery
Gang ZHONG ; Nian-Ping MO ; Zheng-Yao YANG ; Tao JIANG ; Dong-Fang TANG ; Xiao-Yong SHEN
Fudan University Journal of Medical Sciences 2024;51(6):949-956
Objective To investigate the effect of early postoperative abnormal blood glucose on the short-term prognosis of non-small cell lung cancer(NSCLC),and to analyze the clinical characteristics and risk factors related to poor early prognosis.Methods A total of 897 patients with NSCLC who underwent thoracoscopic surgery in Huadong Hospital,Fudan University from Jan 2020 to Aug 2021 were divided into hyperglycemia(HG)group(>7.8 mmol/L)and normal blood glucose(NG)group(≤7.8 mmol/L and≥3.9 mmol/L)according to the early postoperative blood glucose values.Additionally,the patients were divided into higher blood glucose fluctuation group(≥4 mmol/L)and the group with lower blood glucose fluctuation(<4 mmol/L)basing on the fasting blood glucose.Using Logistic regression models,column line charts,ROC curves and other methods,we aimed to clarify the impact of early postoperative blood glucose abnormalities on short-term prognosis,explore clinical characteristics associated with poor short-term outcomes,identify other high-risk factors,and establish relevant risk prediction models.Results Compared with the NG group,the incidence of postoperative pneumonia,thromboembolism,ICU admission rate,total length of hospital stay and hospital cost were significantly higher in the HG group(P<0.05).Higher blood glucose fluctuation group had a greater risk of ICU admission(P=0.003).Logistic regression analysis showed that age,preoperative fasting glucose,white blood cell count and cytokeratin 19 fragment antigen 21-1(CYFRA21-1)were risk factors for postoperative hyperglycemia(P<0.05).Contrary to the effect of BMI,diabetes,male patients,higher blood glucose fluctuation,white blood cell count and age were the risk factors for postoperative adverse events(P<0.05).The AUC of the column line chart model was 0.661(95%CI:0.624-0.698),indicating good discriminative ability for predicting poor short-term prognosis postoperatively.Calibration curves also demonstrated good consistency between predicted and actual probabilities.Conclusion Early postoperative blood glucose fluctuations independently impact the short-term prognosis of thoracoscopic NSCLC patients.Blood glucose combined with gender,BMI,white blood cell count,age and diabetes history can serve as predictive factors for poor short-term prognosis postoperatively.Additionally,a column line chart constructed based on these factors may aid clinicians in early intervention for NSCLC patients with indications.
9.MiR-15b-5p alleviates hypoxia/reoxygenation-induced human renal tubular epithelial cell HK-2 injury by targeting FOXO1
Hua-Feng LI ; Hong-Yi ZHANG ; Ke-Bing XIAO ; Hui YANG ; Zi-Feng LI ; Gang-Gang ZHAO
Medical Journal of Chinese People's Liberation Army 2024;49(11):1311-1318
Objective To investigate the role and underlying mechanism of miR-15b-5p on hypoxia/reoxygenation(H/R)induced human renal tubular epithelial cell(HK-2)injury by targeting forkhead box O1(FOXO1).Methods HK-2 cells in the log growth phase were set up as follows:(1)control group(normal culture)and H/R group(H/R induced culture).The expressions of miR-15b-5p and FOXO1 mRNA were detected using qRT-PCR,and the protein expression of FOXO1 was detected using Western blotting.(2)Control group(normal culture),H/R group(H/R induced culture),H/R+mimic control group(cells transfected with mimic control then induced by H/R),H/R+miR-15b-5p mimic group(cells transfected with miR-15b-5p mimic then induced by H/R),H/R+miR-15b-5p mimic+OE-NC group(cells co-transfected with miR-15b-5p mimic and OE-NC plasmid,then induced by H/R),and H/R+miR-15b-5p mimic+OE-FOXO1 group(cells co-transfected with miR-15b-5p mimic and FOXO1 overexpression plasmid,then induced by H/R).The expression of miR-15b-5p was detected using qRT-PCR,and the protein expressions of FOXO1,cleaved caspase-3,Bax,and Bcl-2 were detected using Western blotting.CCK-8 assay was used to detect cell viability.Cell apoptosis was measured by the TUNEL method.(3)Control group(normal culture),H/R group(H/R induced culture),H/R+miR-15b-5p mimic group(cells transfected with miR-15b-5p mimic then induced by H/R),and H/R+miR-15b-5p mimic+OE-FOXO1 group(cells co-transfected with miR-15b-5p mimic and FOXO1 overexpression plasmid,then induced by H/R).The protein expressions of LC3,p62 and Beclin1 were detected using Western blotting.LC3 immunofluorescence was used to detect the cell autophagy.The target reaction between miR-15b-5p and FOXO1 was assessed using dual luciferase reporting assay.Results Under an inverted microscope,it was observed that the control group had a higher number of cells,most of which were in a typical cobblestone shape and grew in a cobblestone-like manner;most of the cells in the H/R group contracted and became round,with a significant decrease in the number of adherent cells.In H/R-induced HK-2 cells,miR-15b-5p was significantly down-regulated,while miRNA and protein expression of FOXO1 was up-regulated(P<0.05).Luciferase assay results showed that miR-15b-5p directly targeted the 3'-UTR of FOXO1.Overexpression of miR-15b-5p increased cell viability,reduced cell apoptosis,and decreased autophagy in H/R-induced HK-2 cells(P<0.05).Compared with H/R+miR-15b-5p mimic group,the viability of HK-2 cells was decreased,the apoptosis and autophagy level were increased in H/R+miR-15b-5p mimic+OE-FOXO1 group(P<0.05).Conclusion miR-15b-5p inhibited autophagy and alleviated H/R-induced HK-2 cell injury by targeting FOXO1.
10.Synthesis and characterization of matrix metalloproteinase-responsive BDNF controlled-release materials
Jun-Ru HEI ; Cui WANG ; Meng-Wen SONG ; Sheng-Qiang XIE ; Bing-Xian WANG ; Xiao-Juan LAN ; Han-Bo ZHANG ; Gang CHENG ; Zhi-Qiang LIU ; Xi-Qin YANG ; Jian-Ning ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(11):1319-1326
Objective To develop a matrix metalloproteinase(MMP)-responsive hyaluronic acid(HA)-based controlled-release material for brain-derived neurotrophic factor(BDNF)to provide a novel therapeutic strategy for intervention and repair of traumatic brain injury(TBI).Methods HA was modified with amination,followed by condensation with Suflo-SMCC carboxyl group to form amide,and then linked with glutathione(GSH)to synthesize HA-GSH.The recombinant glutathione S-transferase(GST)-tissue inhibitor of metalloproteinase(TIMP)-BDNF(GST-TIMP-BDNF)expression plasmid was constructed using molecular cloning technique with double enzyme digestion by Bam H Ⅰ and Eco R Ⅰ.The recombinant GST-TIMP-BDNF protein was expressed in the Escherichia coli prokaryotic expression system,and purified by ion exchange chromatography,confirmed by Western blotting.MMP diluents were supplemented with PBS,MMP inhibitor marimastat,and varing concentrations(0.4,0.6,0.8 mg/ml)of GST-TIMP-BDNF or GST-BDNF.MMP-2 activity was analyzed using an MMP activity detection kit to evaluate the inhibitory effect of the recombinant protein on MMP.Primary rat neurons were extracted and cultured to establish an iron death model induced by RSL3.The effect of recombinant protein GST-TIMP-BDNF on neuronal injury was detected by immunofluorescence staining.Results MRI hydrogen spectrum identification confirmed the successful synthesis of HA-GSH.Western blotting results showed the successful expression of the recombinant protein GST-TIMP-BDNF containing the GST tag using the E.coli prokaryotic expression system.MMP activity detection results indicated that the recombinant protein GST-TIMP-BDNF had a superior inhibitory effect on MMP-2 activity compared to GST-BDNF(P<0.05).Immunofluorescence staining results showed a significant increase in fluorescence intensity in rat neurons treated with GST-TIMP-BDNF after RSL3 induction(P<0.05).Conclusion A MMP-responsive HA-based BDNF controlled-release material has been successfully developed,exhibiting a protective effect on neuron damage.

Result Analysis
Print