1.Effect of chromosome-instability-associated gene GALNT7 on proliferation and apoptosis of HCT116 colon cancer cells
Xiao Fang ; Wei Zhao ; Wenying Yu ; Lingjie Pei ; Wenxuan Qian ; Ya Zhao
Acta Universitatis Medicinalis Anhui 2025;60(1):96-101
Objective :
To investigate the effect of chromosome instability(CIN) associated gene polypeptide N-acetylgalactosaminyltransferase 7(GALNT7) on proliferation and apoptosis of HCT116 colon cancer cells.
Methods :
The HCT116 cell line withGALNT7knockdown was constructed by lentiviral infection. The correlation betweenGALNT7and CIN was verified by chromosome spread assay. The effect ofGALNT7on cell proliferation was detected by live cell counting, and the effect ofGALNT7on cell cycle distribution was detected by flow cytometry and Western blot. Caspase-3 activity and Western blot assays were used to detect the effect ofGALNT7on apoptosis.
Results :
HCT116 cells showed a slower proliferation rate upon knocking down ofGALNT7, and exhibited a more scattered karyotype distribution and a phenotype of increased degree of CIN. Inhibition ofGALNT7in HCT116 cells resulted in cell cycle arrest, upregulation of P21 and downregulation of CDK6 protein levels, as well as increased levels of Caspase-3 activity, cleaved PARP1 and PUMA protein expression, and decreased levels of BCL-2 protein expression.
Conclusion
TheGALNT7gene may promote proliferation and inhibit apoptosis of HCT116 colon cancer cells through the suppression of CIN generation.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Chemical consitituents and hypoglycemic activity of Sophora tonkinensis
Xiao-yun YAN ; Ling-feng QIN ; Rui ZHANG ; Ya-nan YANG ; Jin-ying TIAN ; Fei YE ; Xu ZHANG ; Pei-cheng ZHANG ; Guo-cheng WANG
Acta Pharmaceutica Sinica 2024;59(11):3135-3140
Eleven compounds were isolated from the ethyl acetate fraction of the 95% aqueous ethanol extract of the roots of
8.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
9.The Effects of RNF213 on the Proliferation and Apoptosis of Acute Myeloid Leukemia THP-1 Cells
Xiao-Qi SHI ; Ping-Ping ZHANG ; Ya-Ning GUAN ; Zuo-Chen DU ; Yan CHEN ; Pei HUANG ; Zhi-Xu HE
Journal of Experimental Hematology 2024;32(5):1365-1371
Objective:To discover the relationship between the RNF213 gene and acute myeloid leukemia(AML),and explore the effect of RNF213 on the proliferation and apoptosis of THP-1 cells.Methods:Analyze the expression of RNF213 gene in AML and its relationship with prognosis through the GEPIA database.Collecting 30 AML patients and non-tumor hematological patients who went to the Affiliated Hospital of Zunyi Medical University from January 2017 to January 2022.RT-qPCR and Western blot were used to detect the expression levels of RNF213 mRNA and protein.Perform survival of patients was analysed by Kaplan-Meier.Meanwhile,the expression levels of RNF213 mRNA and protein were detected in AML cell lines(THP-1,OCI-AML2).CRISPR-Cas9 was used to knockdown the RNF213 gene in THP-1 cells;flow cytometry was used to detect apoptosis rate of cell.CCK-8 and colony formation assay were used to detect cell proliferation.Western blot was used to detect the expression level of Cleaved-Caspase 3 protein.Results:Compared with the control group,the expression level of RNF213 in AML patients was significantly increased,and patients with high expression of RNF213 have a worse prgnosis.Higher expression level of RNF213 protein in THP-1 cells.After knocking down the RNF213 gene of THP-1 cells,cell proliferation was significantly reduced,and the apoptosis rate and expression of apoptosis related protein Cleared-Caspase3 were significantly increased.Conclusion:AML patients have high expression of RNF213,and the prognosis of high expression patients is poor.The RNF213 gene affects AML cell proliferation and apoptosis,and may be a prognostic marker and potential therapeutic target for AML.
10.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.


Result Analysis
Print
Save
E-mail