1.Electrical stimulation induces miR-741-3p to regulate Radil and promote Schwann cell migration
Qing LIU ; Bo GAO ; Xiao YANG ; Yu JIANG ; Pei WANG
Chinese Journal of Tissue Engineering Research 2025;29(19):4038-4043
		                        		
		                        			
		                        			BACKGROUND:More and more animal experiments and clinical studies have confirmed that electrical stimulation can promote the repair of peripheral nerve injury,but the specific mechanism is not yet fully understood. OBJECTIVE:To investigate the effect of electrical stimulation-induced miR-741-3p regulating Radil on Schwann cell migration. METHODS:(1)Twelve male SD rats were randomly divided into electrical stimulation group and control group.The electrical stimulation group received continuous electrical stimulation for 7 days after sciatic nerve compression injury,while the control group was not treated after sciatic nerve compression.The injured nerves were taken on day 7 after operation.The expression difference of miR-741-3p between the two groups was verified by fluorescence in situ hybridization.(2)The target genes of miR-741-3p were predicted by miRDB,TargetScan,and miRWalk databases.(3)Schwann cells were transfected with miR-741-3p mimetic and its control,miR-741-3p inhibitor and its control,Radil siRNA and its control,miR-741-3p inhibitor+Radil siRNA and miR-741-3p inhibitor+siRNA control.The transfection efficiency was detected by RT-PCR.The migration ability of Schwann cells was detected by Transwell chamber. RESULTS AND CONCLUSION:(1)The fluorescence intensity of miR-741-3p in the electrical stimulation group was lower than that in the control group.(2)The results of database prediction showed that 69 genes might be the target genes of miR-741-3p.Radil was one of the predicted target genes,which was mainly involved in cell adhesion and migration.(3)Compared with the miR-741-3p inhibitor control group,the number of Schwann cell migration increased in the miR-741-3p inhibitor group(P<0.05).Compared with the miR-741-3p mimic control group,the number of Schwann cell migration in the miR-741-3p mimic group decreased(P<0.05).Compared with the siRNA control group,the number of Schwann cell migration was decreased in the Radil siRNA group(P<0.05).(4)Compared with miR-741-3p inhibitor control group,the expression level of Radil was increased in miR-741-3p inhibitor group.Compared with miR-741-3p mimic control group,the expression level of Radil was decreased in miR-741-3p mimic group.(5)Compared with miR-741-3p inhibitor+siRNA control group,the number of Schwann cell migration was reduced in miR-741-3p inhibitor+Radil siRNA group(P<0.05).The results showed that electrical stimulation promoted the migration of Schwann cells by down-regulating miR-741-3p and targeting Radil gene.
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.Mechanism of peimine improving chronic obstructive pulmonary disease induced by lipopolysaccharide combined with cigarette smoke in mice
Pei CHEN ; Xiao-Ju CHEN ; Zhu-Man DU ; Cao-Hui WANG
Acta Anatomica Sinica 2024;55(2):215-221
		                        		
		                        			
		                        			Objective To investigate the effects and mechanisms of peimine(PME)on chronic obstructive pulmonary disease(COPD)in mice.Methods The mice were randomly divided into 4 groups(20 mice in each group),control group,PME group,chronic obstructive pulmonary disease group and treatment group.Animal models of COPD were induced in mice by lipopolysaccharide combined with smoke.The effects of PME on COPD model mice was analyzed by HE staining,transmission electron microscopy and the ratio of wet/dry weight of mouse lung tissue.The effects of PME on COPD model mice were analyzed by HE staining,transmission electron microscopy and the ratio of wet/dry weight of mouse lung tissue.The effects of PME on inflammatory factor tumor necrosis factor(TNF)-α,interleukin(IL)-6 and IL-1β in lung tissue were analyzed by ELISA and Western blotting.The effects of PME on oxidative stress in lung tissue were analyzed by dihydroethidium(DHE)staining and Western blotting.The effects of PME on nuclear factor kappa-B(NF-κB)pathway and nuclear factor erythroid 2-related factor 2(Nrf2)pathway were analyzed by protein immunoblotting.Results Compared with the COPD group,PME treatment could significantly improve the lung tissue injury and the number of inflammatory cells in mice,and the wet/dry weight ratio of lung tissue was significantly reduced.Compared with the control group,the levels of TNF-α,IL-6 and IL-1β in the alveolar lavage fluid of COPD mice significantly increased,and the level of TNF-α,IL-6 and IL-1β in the alveolar lavage fluid of mice after PME treatment was significantly reduced.In addition,compared with the control group,the protein expression of TNF-α,IL-6 and IL-1β in the lung tissue of COPD mice significantly increased,and the level of TNF-α,IL-6 and IL-1β in the lung tissue of COPD mice after PME treatment were significantly reduced.Immunohistochemistry and Western blotting showed that the level of superoxide dismutase 2(SOD2)protein in COPD group was significantly lower than that in control group,while PME treatment could improve the level of superoxide dismutase protein.The analysis of MDA content in lung tissue showed that compared with the COPD group,the production of MDA in lung tissue of COPD mice was significantly inhibited after PME treatment.Protein Western blotting showed that PME treatment could prevent the phosphorylation of inhibitor of NF-κB(IκBα)and the transfer of NF-κB p65 to the cell nucleus,and the expression of Nrf2 and its main downstream target heme oxygenase-1(HO-1)in the lung tissue of mice treated with PME significantly increased.Conclusion PME is able to inhibit inflammation and oxidative stress and improve lung tissues damage in the COPD model in vivo and this protection effect might be both the Nrf2 pathway activation and NF-κB pathway inhibition.
		                        		
		                        		
		                        		
		                        	
8.Progress of Multi-Parameter Magnetic Resonance Imaging in Evaluating the Efficacy of Neoadjuvant Chemoradiotherapy for Locally Advanced Rectal Cancer
Xiao WANG ; Wenguang LIU ; Yigang PEI ; Wenzheng LI
Chinese Journal of Medical Imaging 2024;32(3):299-304
		                        		
		                        			
		                        			Neoadjuvant chemoradiotherapy is a part of the current standard treatment mode for locally advanced rectal cancer,which enables a certain proportion of patients to achieve complete tumor response,improving the surgical resection rate and anal retention rate,and then prolonging the disease-free survival period of patients.MRI is the preferred imaging examination to evaluate the efficacy of neoadjuvant therapy.With the development of functional MRI,quantitative parameters derived from different imaging principles can provide more biological information about tumors,improving the clinical application value of MRI.Multi-parameter MRI combining conventional MRI sequences and functional sequences can more comprehensively evaluate the efficacy of neoadjuvant therapy,which is conducive to developing individualized treatment plans for patients in clinical practice and realize precision medicine.
		                        		
		                        		
		                        		
		                        	
9.Research advance of Flash-RT in tumor treatment
Yuan WANG ; Lehui DU ; Pei ZHANG ; Qingchao SHANG ; Xingdong GUO ; Jiangyue LU ; Xiao LEI ; Baolin QU
China Medical Equipment 2024;21(1):9-14,20
		                        		
		                        			
		                        			The Flash radiotherapy(Flash-RT),which is the key breakthrough in the basic field of radiotherapy technique,which is expected to cause a new major transformation in the field of radiotherapy.In this paper,we reviewed the latest research advances of the application and the mechanism exploration of Flash-RT in tumor treatment.Current studies have found that both the Flash-RT with electron beams and photon and the Flash-RT with proton can reduce injury of normal tissue than radiotherapy with conventional dose-rate,but the relevant mechanisms are not yet clearly understood,which includes but not limited to oxygen depletion,DNA damage,cellular senescence,apoptosis and immune response.The difference of Flash-RT injury between tumor tissue and normal tissue further reduces the limitations of radiotherapy,and reduces the adverse reaction and complication compared with conventional radiotherapy,which has wide application prospects.
		                        		
		                        		
		                        		
		                        	
10.The application of percutaneous puncture renal fascia suspension in laparoscopic partial nephrectomy
Qi LI ; Pei ZHENG ; Yusheng WANG ; Guangyuan JING ; Mingrui WANG ; Bo ZHAO ; Tengfei XU ; Xiaoli WANG ; Kaidong WANG ; Xiao PAN ; Fen YIN
Chinese Journal of Urology 2024;45(1):53-54
		                        		
		                        			
		                        			When partial nephrectomy is performed by posterior abdominal approach, the surgical field is poorly exposed, resulting in increased surgical difficulty and risk of injury.In this study, 28 patients with T 1a stage kidney tumors underwent retroperitoneal laparoscopic partial nephrectomy. Intraoperatively, exposure of the surgical field was achieved using the percutaneous puncture of the renal fascia suspension technique. There were no dissatisfactory exposures due to peritoneal damage during the surgery, no additional tubes were inserted, and no conversions to open surgery were needed. The operation time was (76.5±20.3) minutes, blood loss was (92.1±18.7) ml, renal artery clamping time was (19.5±4.3) minutes. Postoperatively, there were no complications such as bleeding, infection, or hematuria.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail