1.Applications of Vaterite in Drug Loading and Controlled Release
Xiao-Hui SONG ; Ming-Yu PAN ; Jian-Feng XU ; Zheng-Yu HUANG ; Qing PAN ; Qing-Ning LI
Progress in Biochemistry and Biophysics 2025;52(1):162-181
Currently, the drug delivery system (DDS) based on nanomaterials has become a hot interdisciplinary research topic. One of the core issues is drug loading and controlled release, in which the key lever is carriers. Vaterite, as an inorganic porous nano-material, is one metastable structure of calcium carbonate, full of micro or nano porous. Recently, vaterite has attracted more and more attention, due to its significant advantages, such as rich resources, easy preparations, low cost, simple loading procedures, good biocompatibility and many other good points. Vaterite, gained from suitable preparation strategies, can not only possess the good drug carrying performance, like high loading capacity and stable loading efficiency, but also improve the drug release ability, showing the better drug delivery effects, such as targeting release, pH sensitive release, photothermal controlled release, magnetic assistant release, optothermal controlled release. At the same time, the vaterite carriers, with good safety itself, can protect proteins, enzymes, or other drugs from degradation or inactivation, help imaging or visualization with loading fluorescent drugs in vitro and in vivo, and play synergistic effects with other therapy approaches, like photodynamic therapy, sonodynamic therapy, and thermochemotherapy. Latterly, some renewed reports in drug loading and controlled release have led to their widespread applications in diverse fields, from cell level to clinical studies. This review introduces the basic characteristics of vaterite and briefly summarizes its research history, followed by synthesis strategies. We subsequently highlight recent developments in drug loading and controlled release, with an emphasis on the advantages, quantity capacity, and comparations. Furthermore, new opportunities for using vaterite in cell level and animal level are detailed. Finally, the possible problems and development trends are discussed.
2.Acute Inflammatory Pain Induces Sex-different Brain Alpha Activity in Anesthetized Rats Through Optically Pumped Magnetometer Magnetoencephalography
Meng-Meng MIAO ; Yu-Xuan REN ; Wen-Wei WU ; Yu ZHANG ; Chen PAN ; Xiang-Hong LIN ; Hui-Dan LIN ; Xiao-Wei CHEN
Progress in Biochemistry and Biophysics 2025;52(1):244-257
ObjectiveMagnetoencephalography (MEG), a non-invasive neuroimaging technique, meticulously captures the magnetic fields emanating from brain electrical activity. Compared with MEG based on superconducting quantum interference devices (SQUID), MEG based on optically pump magnetometer (OPM) has the advantages of higher sensitivity, better spatial resolution and lower cost. However, most of the current studies are clinical studies, and there is a lack of animal studies on MEG based on OPM technology. Pain, a multifaceted sensory and emotional phenomenon, induces intricate alterations in brain activity, exhibiting notable sex differences. Despite clinical revelations of pain-related neuronal activity through MEG, specific properties remain elusive, and comprehensive laboratory studies on pain-associated brain activity alterations are lacking. The aim of this study was to investigate the effects of inflammatory pain (induced by Complete Freund’s Adjuvant (CFA)) on brain activity in a rat model using the MEG technique, to analysis changes in brain activity during pain perception, and to explore sex differences in pain-related MEG signaling. MethodsThis study utilized adult male and female Sprague-Dawley rats. Inflammatory pain was induced via intraplantar injection of CFA (100 μl, 50% in saline) in the left hind paw, with control groups receiving saline. Pain behavior was assessed using von Frey filaments at baseline and 1 h post-injection. For MEG recording, anesthetized rats had an OPM positioned on their head within a magnetic shield, undergoing two 15-minute sessions: a 5-minute baseline followed by a 10-minute mechanical stimulation phase. Data analysis included artifact removal and time-frequency analysis of spontaneous brain activity using accumulated spectrograms, generating spectrograms focused on the 4-30 Hz frequency range. ResultsMEG recordings in anesthetized rats during resting states and hind paw mechanical stimulation were compared, before and after saline/CFA injections. Mechanical stimulation elevated alpha activity in both male and female rats pre- and post-saline/CFA injections. Saline/CFA injections augmented average power in both sexes compared to pre-injection states. Remarkably, female rats exhibited higher average spectral power 1 h after CFA injection than after saline injection during resting states. Furthermore, despite comparable pain thresholds measured by classical pain behavioral tests post-CFA treatment, female rats displayed higher average power than males in the resting state after CFA injection. ConclusionThese results imply an enhanced perception of inflammatory pain in female rats compared to their male counterparts. Our study exhibits sex differences in alpha activities following CFA injection, highlighting heightened brain alpha activity in female rats during acute inflammatory pain in the resting state. Our study provides a method for OPM-based MEG recordings to be used to study brain activity in anaesthetized animals. In addition, the findings of this study contribute to a deeper understanding of pain-related neural activity and pain sex differences.
3.Mechanism of Ferroptosis in Cerebral Ischemia-reperfusion and Interventional Mechanism of Huoxue Huayu Jiedu Prescription Based on "Blood Stasis and Toxin" Pathogenesis
Jiayue HAN ; Danyi PAN ; Jiaxuan XIAO ; Yuchen LIU ; Jiyong LIU ; Yidi ZENG ; Jinxia LI ; Caixing ZHENG ; Hua LI ; Wanghua LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(8):51-60
ObjectiveTo explore the material basis of the "interaction of blood stasis and toxin" mechanism in cerebral ischemia-reperfusion injury, as well as the protective role of Huoxue Huayu Jiedu prescription (HXHYJDF) against ferroptosis. MethodsSixty SPF-grade male SD rats were randomly divided into six groups: sham group, model group, deferoxamine (DFO) group (100 mg·kg-1), low-dose HXHYJDF group (4.52 g·kg-1), medium-dose HXHYJDF group (9.04 g·kg-1), and high-dose HXHYJDF group (18.07 g·kg-1), with ten rats in each group. Except for the sham group, the other groups were used to replicate the model of focal cerebral ischemia-reperfusion in the middle cerebral artery of rats by the reforming Longa method. Neurological function was assessed at 1st, 3rd, 5th, and 7th days post-reperfusion using the modified neurological severity scores (m-NSS). Brain tissue pathology and the morphology of mitochondria were observed using hematoxylin-eosin (HE) staining and transmission electron microscopy. The contents of malondialdehyde (MDA), glutathione (GSH), divalent iron ions (Fe2+), and reactive oxygen species (ROS) in the ischemic cerebral tissue were detected using enzyme-linked immunosorbent assay (ELISA). Immunohistochemistry and Western blot (WB) were used to detect the expression of iron death marker proteins glutathione peroxidase 4 (GPX4), ferroportin-1 (FPN1), transferrin receptor protein 1 (TfR1), and ferritin mitochondrial (FtMt) in brain tissue. ResultsCompared with the sham group, the mNSS score of the model group was significantly increased (P<0.01). HE staining showed that the number of neurons in the cortex of brain tissue was seriously reduced, and the intercellular space was widened. The nucleus was fragmented, and the cytoplasm was vacuolated. The results of transmission electron microscopy showed that the mitochondria in the cytoplasm contracted and rounded, and the mitochondrial cristae decreased. The matrix was lost and vacuolated, and the density of the mitochondrial bilayer membrane increased. The results of ELISA showed that the content of GSH decreased significantly (P<0.01), and the contents of MDA, Fe2+, and ROS increased significantly (P<0.01). The results of immunohistochemistry and WB showed that the expression of GPX4 and FPN1 proteins was significantly decreased (P<0.01), and the expression of FtMt and TfR1 proteins was significantly increased (P<0.01). Compared with those of the model group, the m-NSS scores of the high-dose and medium-dose HXHYJDF groups began to decrease on the 3rd and 5th days, respectively (P<0.05, P<0.01). The results of HE and transmission electron microscopy showed that the intervention of HXHYJDF improved the pathological changes of neurons and mitochondria. The results of ELISA showed that the content of GSH in the medium-dose and high-dose HXHYJDF groups increased significantly (P<0.01), and the contents of MDA, Fe2+, and ROS decreased significantly (P<0.05, P<0.01). The content of GSH in the low-dose HXHYJDF group increased significantly (P<0.01), and the contents of MDA and ROS decreased significantly (P<0.01). The results of immunohistochemistry showed that the expression of GPX4 and FPN1 in the high-dose HXHYJDF group increased significantly (P<0.01), and the expression of FtMt and TfR1 decreased significantly (P<0.01). The expression of GPX4 and FPN1 in the medium-dose HXHYJDF group increased significantly (P<0.05), and the expression of TfR1 decreased significantly (P<0.01). WB results showed that the expression levels of FPN1 and GPX4 proteins in the high-dose, medium-dose, and low-dose HXHYJDF groups were significantly up-regulated (P<0.01), and the expression levels of FtMt and TfR1 proteins were significantly down-regulated (P<0.01). ConclusionHXHYJDF can significantly improve neurological dysfunction symptoms in rats with cerebral ischemia-reperfusion injury, improve the pathological morphology of the infarcted brain tissue, and protect the brain tissue of rats with cerebral ischemia-reperfusion injury to a certain extent. Neuronal ferroptosis is involved in cerebral ischemia-reperfusion injury, with increased levels of MDA, Fe2+, ROS, and TfR1 and decreased levels of FtMt, FPN1, GPX4, and GSH potentially constituting the material basis of the interaction of blood stasis and toxin mechanism in cerebral ischemia-reperfusion injury. HXHYJDF may exert brain-protective effects by regulating iron metabolism-related proteins, promoting the discharge of free iron, reducing brain iron deposition, alleviating oxidative stress, and inhibiting ferroptosis.
4.Study on the improvement effects of Compound qinbai granules on ulcerative colitis in rats and its mechanism
Shouyan HE ; Wenpeng LUO ; Liao PAN ; Jinyin XIAO ; Zhenquan WANG
China Pharmacy 2025;36(6):686-691
OBJECTIVE To investigate the improvement effects of Compound qinbai granules on ulcerative colitis (UC) in rats and its mechanism based on short-chain fatty acid (SCFA) and their targets G protein-coupled receptor (GPR). METHODS Male SD rats were randomly divided into normal group (12 rats) and model group (30 rats); the model group was given 5% dextran sulfate sodium solution to induce the UC model. Model rats were divided into the model group, positive control group [Mesalazine enteric-coated tablets 270 mg/(kg·d)] and Compound qinbai granules group [2.52 g/(kg·d)], with 9 rats in each group. Rats in each group were orally administered with normal saline or corresponding medication twice a day, for three consecutive weeks. During intragastric administration, the general conditions of rats in each group were observed, and the disease activity index (DAI) scores were assessed after the last administration. Serum levels of pro-inflammatory cytokines (tumor necrosis factor-α, interleukin-6) and anti-inflammatory cytokines (transforming growth factor-β1, interleukin-10) were measured. Pathological changes in their colonic tissues were observed and scored. Additionally, the content of SCFA (acetic acid, propionic acid and butyric acid) in their feces as well as the protein and mRNA expressions of GPR41, GPR43 and GPR109A in colonic tissues were detected. RESULTS Compared with the normal group, rats in the model group exhibited lethargy and obvious blood in their feces; the colonic tissue structure was severely damaged, with pathological changes such as notable glandular loss, edema, and inflammatory cell infiltration visible; the serum levels of pro- inflammatory cytokines, DAI score and colonic pathology score were significantly increased, while the levels of anti-inflammatory cytokines, SCFA content, and protein and mRNA expressions of GPR41, GPR43 and GPR109A were significantly decreased or down-regulated (P<0.01). Compared with the model group, the general condition and pathological changes of colonic tissue in each administration group showed improvement, with significant reversal observed in the aforementioned quantitative indicators (P<0.05 or P<0.01). CONCLUSIONS Compound qinbai granules can alleviate intestinal inflammation and intestinal mucosal damage in UC rats. These effects may be related to its ability to restore intestinal SCFA levels and the expression of their target GPR.
5.Construction Process and Quality Control Points of the Database for Facial Phenotypes and Clinical Data of Pediatric Growth and Development-related Diseases
Jiaqi QIANG ; Yingjing WANG ; Danning WU ; Runzhu LIU ; Jiuzuo HUANG ; Hui PAN ; Xiao LONG ; Shi CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(3):552-557
The growth and development of children is an important stage for health, and its monitoringand intervention are related to the long-term development of individuals. The construction of a standardized and multi-dimensional database of pediatric growth and development-related diseases is an important basis for realizing precise diagnosis and treatment and health management. Based on the needs of clinical practice, this study proposes to establish a specialized database of pediatric growth and development-related diseases that integrates facial phenotypes and clinical diagnosis and treatment information. This study elaborates on the construction process, including data sources, data collection content, and the operation and management of the database; and proposes key points for quality control, including the establishment of quality control nodes, database construction standards, and a full-process quality control framework. The above ensure the integrity, logic and effectiveness of the data, so that the database can provide an objective basis for the screening and diagnosis of pediatric growth and development-related diseases. On the basis of scientific data management and strict quality control, the database will help reveal the patterns of children's growth and development, and promote the level of children's health management.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail