1.Characteristic ion Identification of Different Original Haliotidis Concha and Its Counterfeits
Xiaojie LIANG ; Guowei LI ; Lin ZHOU ; Qiping HU ; Muxiang LUO ; Jiehao TANG ; Xiangdong CHEN ; Liye PAN ; Dongmei SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):263-269
ObjectiveTo establish a method for the identification of Haliotidis Concha and its counterfeits, and to improve its quality evaluation method. MethodsA total of 17 batches of Haliotis discus hannai, 4 batches of H. ruber, 3 batches of H. laevigata, 3 batches of H. ovina, 3 batches of H. diversicolor, 3 batches of H. asinina, 3 batches of H. iris were collected. Ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC-Q-Exactive-Orbitrap-MS/MS) was used to analyze the hydrolysates of different original Haliotidis Concha and its counterfeits, and the potential characteristic ions of each species were screened by Venn diagram. UPLC-triple quadrupole tandem mass spectrometry(UPLC-QqQ-MS/MS) was used to validate the characteristic ions, and the specific detection method of the characteristic ions was established. ResultsA total of 1 182, 167, 47, 89, 104, 203, 424 potential characteristic ions were screened from H. discus hannai, H. ruber, H. laevigata, H. ovina, H. diversicolor, H. asinina and H. iris, respectively. And 9 characteristic ions were selected. The precision, stability and repeatability of the 9 characteristic ions in the established identification method met the requirements. Different original Haliotidis Concha and its counterfeits could detect their own characteristic ions, including m/z 631.83-886.48(double charge) and m/z 631.83-443.74(double charge) of H. discus hannai, m/z 699.28-232.11(double charge) and m/z 699.28-544.27(double charge) of H. ruber, m/z 535.76-752.37(double charge) and m/z 535.76-548.28(double charge) of H. laevigata, m/z 708.35-442.28(double charge) and m/z 708.35-215.14(double charge) of H. ovina, m/z 561.33-614.86(triple charge), m/z 561.33-468.28(triple charge), m/z 608.29-618.32(double charge) and m/z 608.29-390.21(double charge) of H. diversicolor, m/z 769.85-274.10(double charge), m/z 769.85-532.75(double charge), m/z 827.43-646.36(single charge), m/z 827.43-257.12(single charge) of H. asinina, and m/z 468.24-576.29(double charge) and m/z 468.24-505.26(double charge) of H. iris. ConclusionIn this study, a total of 9 characteristic ions are screened from 6 kinds of original Haliotidis Concha and its counterfeits, and a specific identification method is established, which is helpful to solve the limitations of the existing quality evaluation methods of Haliotidis Concha, and provide a basis for the production, circulation and medication quality.
2.Characteristic ion Identification of Different Original Haliotidis Concha and Its Counterfeits
Xiaojie LIANG ; Guowei LI ; Lin ZHOU ; Qiping HU ; Muxiang LUO ; Jiehao TANG ; Xiangdong CHEN ; Liye PAN ; Dongmei SUN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):263-269
ObjectiveTo establish a method for the identification of Haliotidis Concha and its counterfeits, and to improve its quality evaluation method. MethodsA total of 17 batches of Haliotis discus hannai, 4 batches of H. ruber, 3 batches of H. laevigata, 3 batches of H. ovina, 3 batches of H. diversicolor, 3 batches of H. asinina, 3 batches of H. iris were collected. Ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC-Q-Exactive-Orbitrap-MS/MS) was used to analyze the hydrolysates of different original Haliotidis Concha and its counterfeits, and the potential characteristic ions of each species were screened by Venn diagram. UPLC-triple quadrupole tandem mass spectrometry(UPLC-QqQ-MS/MS) was used to validate the characteristic ions, and the specific detection method of the characteristic ions was established. ResultsA total of 1 182, 167, 47, 89, 104, 203, 424 potential characteristic ions were screened from H. discus hannai, H. ruber, H. laevigata, H. ovina, H. diversicolor, H. asinina and H. iris, respectively. And 9 characteristic ions were selected. The precision, stability and repeatability of the 9 characteristic ions in the established identification method met the requirements. Different original Haliotidis Concha and its counterfeits could detect their own characteristic ions, including m/z 631.83-886.48(double charge) and m/z 631.83-443.74(double charge) of H. discus hannai, m/z 699.28-232.11(double charge) and m/z 699.28-544.27(double charge) of H. ruber, m/z 535.76-752.37(double charge) and m/z 535.76-548.28(double charge) of H. laevigata, m/z 708.35-442.28(double charge) and m/z 708.35-215.14(double charge) of H. ovina, m/z 561.33-614.86(triple charge), m/z 561.33-468.28(triple charge), m/z 608.29-618.32(double charge) and m/z 608.29-390.21(double charge) of H. diversicolor, m/z 769.85-274.10(double charge), m/z 769.85-532.75(double charge), m/z 827.43-646.36(single charge), m/z 827.43-257.12(single charge) of H. asinina, and m/z 468.24-576.29(double charge) and m/z 468.24-505.26(double charge) of H. iris. ConclusionIn this study, a total of 9 characteristic ions are screened from 6 kinds of original Haliotidis Concha and its counterfeits, and a specific identification method is established, which is helpful to solve the limitations of the existing quality evaluation methods of Haliotidis Concha, and provide a basis for the production, circulation and medication quality.
3.Study on the quality of Bolbostemmatis Rhizoma standard decoction by HPLC fingerprint combined with quantitative analysis of multi-components by single marker
Zhenyu LI ; Xiangyuan ZHOU ; Yifei MA ; Xian QIU ; Minyou HE ; Xiangdong CHEN ; Dongmei SUN
International Journal of Traditional Chinese Medicine 2024;46(1):76-83
Objective:To establish the HPLC fingerprint of Bolbostemmatis Rhizoma standard decoction; To determine the three effective components with similar structure by quantitative analysis of multi-components by single marker (QAMS); To evaluate the quality of Bolbostemmatis Rhizoma standard decoction.Methods:HPLC was adopted to establish the fingerprints of 15 batches of Bolbostemmatis Rhizoma standard decoction. The Chromatographic column was Waters XBridge Phenyl (4.6 mm×250 mm, 5 μm). The mobile phase was acetonitrile-0.1% phosphoric acid solution with gradient elution. Cluster analysis (HCA) and principal component analysis (PCA) were conducted based on the relative peak area of common peaks. The same method as the fingerprint was used to establish QAMS of tubeimoside A, B, C on Bolbostemmatis Rhizoma standard decoction.Results:There were 14 common peaks in the fingerprint of Bolbostemmatis Rhizoma standard decoction. It was confirmed that the peak 3 was L-tryptophan, the peak 11 was tubeimoside B, the peak 12 was tubeimoside C, and the peak 13 was tubeimoside A. 15 batches of Bolbostemmatis Rhizoma standard decoction from different origins were divided into 3 categories by HCA and PCA. There was no significant difference between QAMS and the external standard method (ESM) through the system suitability inspection. Conclusion:This method is accurate, reliable and has good specificity, which can effectively evaluate the quality of Bolbostemmatis Rhizoma standard decoction.
4.Study on quality evaluation of Buddleja officinalis from different habitats based on HPLC fingerprint and content determination
Cuijie WEI ; Xiaoxia LIU ; Zhiwen DUAN ; Yongwei FENG ; Xiaozhou JIA ; Yueyi LIANG ; Xiangdong CHEN ; Dongmei SUN ; Zhenyu LI
International Journal of Traditional Chinese Medicine 2024;46(2):215-221
Objective:To establish UPLC fingerprint method and 2 contents determination methods of Buddleja officinalis; To provide a reference for improving the quality control standard and evaluation of Buddleja officinalis from different habitats.Methods:UPLC method was used to establish the fingerprints of 17 batches of Buddleja officinalis. The similarity evaluation, clustering analysis, principal component analysis and orthogonal partial least squares discriminant analysis were used to compare the quality differences of Buddleja officinalis from different habitats. The contents of acteoside and linarin in Buddleja officinalis were determined.Results:There were 12 common peaks in UPLC fingerprints of Buddleja officinalis, six of which were identified as echinacoside, acteoside, cynaroside, isoacteoside, linarin, and apigenin. The fingerprint similarity of 17 batches of Buddleja officinalis was more than 0.9; Buddleja officinalis from different habitats were classified into 2 groups. Five differential markers were determined by OPLS-DA analysis. The order of significance was acteoside > peak 3 > echinacoside > isoacteoside > linarin. Edgeworthia chrysantha was identified by the method of fingerprint as counterfeit. The results of content determination showed that the content of Buddleja officinalis in Hubei and Sichuan was the high and stable.Conclusion:The method can effectively analyze the differences of Buddleja officinalis from different habitats, and provide reference for the quality control of Buddleja officinalis.
5.Various arginine configurations-modified chitosan hydrogels promote skin wound repair
Jing DENG ; Tinghua LI ; Hai ZHU ; Xiao YANG ; Jun CAO ; Xiangdong ZHU
Chinese Journal of Tissue Engineering Research 2024;28(10):1497-1504
BACKGROUND:Clinical skin wound healing continues to be a significant concern,and tissue repair research has moved to the forefront with the development of biomaterials with immunomodulatory properties.Therefore,it is crucial to research wound dressings that have immunomodulatory properties. OBJECTIVE:To prepare chitosan hydrogels that have been modified by arginine with different configurations and assess their capacity to speed up wound healing in a rat animal model. METHODS:(1)In vitro trial:Chitosan modified by pure L-arginine,pure D-arginine,and L-arginine and D-arginine was synthesized by EDC/NHS system,which was then crosslinked with aldehyde-modified four-arm polyethylene glycol.Different chitosan-based hydrogels(CS-L,CS-D,and CS-DL)were finally formed via the Schiff base reaction.Three kinds of hydrogel extracts were co-cultured with fibroblasts respectively.Hydrogel cytocompatibility was assessed using the CCK-8 assay and live/dead staining.The effect of hydrogel on the migration capacity of fibroblasts was assessed by using a scratch test.Three kinds of hydrogels were incubated with rat erythrocyte suspension respectively to evaluate the hemocompatibility of the hydrogels.The hydrogel extract was co-cultured with RAW264.7 macrophages to test the hydrogels'capacity to enhance macrophage NO generation and polarize macrophage phenotype.(2)In vivo experiment:A total of 36 adult SD rats were divided into 4 groups with 9 rats in each group by the random number table method.Two full-layer skin defect wounds of 2 cm×2 cm were made on the back of each rat.Normal saline was added to the wounds of the control group,and corresponding hydrogel was added to the wounds of the CS-L,CS-D,and CS-DL groups,respectively,and then bandaged and fixed.The wound healing was observed regularly after operation.Hematoxylin-eosin staining was performed at 3,10,and 21 days after operation.The samples were collected 10 days after operation and M2 macrophage immunofluorescence staining was performed. RESULTS AND CONCLUSION:(1)In vitro experiments:Under scanning electron microscopy,the three kinds of hydrogels exhibited obvious interpenetrating network structures with pore sizes ranging from 70-200 μm.The three kinds of hydrogels have good swelling performance,degradation performance,self-healing performance,and suitable mechanical strength.The three kinds of hydrogels had good cytocompatibility and hemocompatibility and could promote the migration of fibroblasts.All three kinds of hydrogels had the ability to promote the polarization of macrophages,and CS-D hydrogels had the strongest ability to promote the polarization of macrophages.CS-L hydrogel could significantly promote the production of NO in macrophages.(2)In vivo experiment:3 and 10 days after operation,the wound healing rate in the CS-L and CS-D groups was higher than that in the control group(P<0.05).After 21 days,the wound healing rate of the three hydrogel groups was higher than that of the control group.Hematoxylin-eosin staining displayed that a large number of inflammatory cells were infiltrated in the wound tissue of rats in all groups,accompanied by neovessels and fibroblasts 3 days after operation.10 days after operation,there was still more inflammatory cell infiltration in the wound of the control group,and the inflammation of the other three groups was improved,especially the decrease of inflammatory cells in the CS-D group was more obvious.21 days after operation,the wound epithelium of each group was well repaired,and there was basically no inflammatory cell infiltration in the CS-L and CS-D groups,while there was still a small amount of inflammatory cell infiltration in the control group.Immunofluorescence staining revealed that the number of M2-type macrophages in the CS-D group was higher than that in the other three groups(P<0.05).(3)The results conclude that chitosan hydrogels modified by different configurations of arginine can promote wound healing through different mechanisms.
6.Effects of distal tibial tuberosity-high tibial osteotomy on ankle angle on coronal plane
Yuetong YIN ; Guangyu ZHU ; Xiangdong TIAN ; Yetong TAN ; Sheng MA ; Zhipeng XUE ; Yuanyi HU ; Xiaomin LI
Chinese Journal of Tissue Engineering Research 2024;28(21):3349-3354
BACKGROUND:Distal tibial tuberosity-high tibial osteotomy is a surgical treatment for knee osteoarthritis,but there is still a lack of clinical studies on its effect on ankle joints. OBJECTIVE:To observe the effects of distal tibial tuberosity-high tibial osteotomy on ankle angle on coronal plane of the radiography of the full length of lower limb in weight loading. METHODS:Data of 40 patients(41 knees)with distal tibial tuberosity-high tibial osteotomy from March 2021 to March 2022 were retrospectively analyzed,including 31 females and 9 males,20 left knees and 21 right knees,aged 49-75 years,mean(63.44±6.57)years.The radiographic data of the full length of the lower limb in weight loading were collected before,week 2 and week 48 postoperatively.Hip-knee-ankle angle,talar tilt angle,tilt angle of the ankle,tibiocrural angle,and tibial articular surface angle were measured before and after surgery. RESULTS AND CONCLUSION:(1)Hip-knee-ankle angle improved from(-6.24±3.69)° before operation to(2.59±3.49)° week 2 postoperatively and(2.15±3.49)° week 48 postoperatively.The tilt angle of the ankle changed from(-7.90±3.11)° before operation to(-2.51±2.59)° week 2 postoperatively and(-2.46±2.42)° week 48 postoperatively,with statistically significant difference(P<0.001).(2)There was no significant difference in talar tilt angle,tibiocrural angle,and tibial articular surface angle before and week 2 postoperatively.(3)No significant difference in the angle changes was detected between week 2 and week 48 postoperatively.(4)It is indicated that distal tibial tuberosity-high tibial osteotomy can not only correct genu varus but also improve ankle angle.This result remains stable after 48 weeks of weight-bearing activities.
7.Application of` the variable angle traction method by using clip with dental in super minimally invasive non full thickness resection of early gastric cancer
Qun SHAO ; Xiangdong WANG ; Ke HAN ; Jinping LI ; Zhaobei CAI ; Enqiang LINGHU ; Qianqian CHEN
Chinese Journal of Postgraduates of Medicine 2024;47(3):221-225
Objective:Assisted traction technology is effective in increasing the rate of super minimally invasive surgery (SMIS) in patients with early gastric cancer (EGC), and shortening the operator′s learning curve. We adopt the variable angle traction technique of tissue clamp dental floss as a traction technique in this research.Methods:Patients with early gastric cancer who were treated with SMIS - non full layer resection of EGC were enrolled in the First Medical Center of Chinese PLA General Hospital from January 2022 to June 2023. This research was carried out by experts at the same level. It was divided into two groups: traction and non-traction. Submucosal detachment time (SDT), submucosal detachment rate (SDS), lamina propria exposure, muscularis propria defect (MPD), bleeding during operation, block resection, surgical resection, hand operation expenses, and surgical instruments were recorded.Results:Nine patients adopted variable angle traction, and 9 patients did not. The overall resection rate and curative resection rate of both groups were 100%. The mean SDT time was 28.00 (21.00, 34.00) min in traction group and 56.00 (40.00, 85.00) min in non traction group. And it had statistical significance ( P = 0.005). The SDS was (0.58 ± 0.21) cm 2/min in traction group and (0.23 ± 0.10) cm 2/min in non-traction group. And it had statistical significance ( P<0.05). Exposure of intrinsic muscle layer (IML): 8 cases in the traction group and 6 cases in the non-traction group. Intraoperative IML injury: in the traction group, 8 cases were MPD-0 and 1 case was MPD-Ft; in the non-traction group, 4 cases were MPD-0, 1 case was MPD-Pt, and 4 cases were MPD-Ft. There was no statistical difference between the two groups in terms of intraoperative bleeding, hospitalization expenses, surgical expenses, and the total hospitalization time. There were no serious adverse reactions or outcomes. Conclusions:The variable angle traction method accelerates SDT and SDS for SMIS-non full layer resection of EGC. It has the advantages of the sufficient separation of IML and mucosal layer, the deeper dissection depth, the low injury of IML, low intraoperative bleeding, and no additional medical costs. Therefore, this method can become an auxiliary treatment technology for SMIS.
8.Evaluation of Mechanical Properties of Three-Dimensional-Printed Metal Vertebral Body Substitutes
Enchun DONG ; Jianfeng KANG ; Changning SUN ; Dichen LI ; Yang LUO ; Ling WANG ; Xiangdong LI
Journal of Medical Biomechanics 2024;39(1):76-83
Objective To study the mechanical properties of titanium mesh and three-dimensional(3D)-printed metal vertebral body substitutes(VBS)to provide guidance for the selection and structural optimization of artificial vertebral implants in clinical practice.Methods The equivalent elastic modulus,equivalent yield strength,and structural failure mode of titanium mesh and 3D-printed porous,truss,and topologically optimized VBS were systematically investigated using compression tests.Results The elastic modulus of the titanium mesh(2 908.73±287.39 MPa)was only lower than that of the topologically optimized VBS.However,their structural strengths and stabilities were inadequate.The yield strength of the titanium mesh(46.61±4.85 MPa)was only higher than that of the porous VBS and it was the first to yield during compression.The porous VBS was insufficient for use as the vertebral implant owing to its poor mechanical strength(18.14±0.17 MPa-25.79±0.40 MPa).The truss VBS had good elastic modulus(2 477.86±55.19 MPa-2 620.08±194.36 MPa)and strength(77.61±0.50 MPa-88.42±1.07 MPa).However,the structural stability of the truss VBS was insufficient,and instability occurred easily during compression.The topologically optimized VBS had the highest elastic modulus(3 746.28±183.80 MPa)and yield strength(177.43±3.82 MPa)among all the tested VBS types,which could provide improved security and stability for artificial vertebral implant in vivo services.Conclusions Topology optimization results in a high strength and high stability VBS design.Moreover,it provides a large design space and great safety margin to provide increased possibilities for lightweight and new material design of future artificial vertebral implants.
9.Evaluation of short-term effects on 3D printing patient-matched artificial vertebral body in clinical research and application
Xiaokang LI ; Lei SHI ; Xiangdong LI ; Hai HUANG ; Qi WU ; Xiaodong TANG ; Zheng GUO
Chinese Journal of Orthopaedics 2024;44(6):354-361
Objective:To evaluate the short-term efficacy and safety of 3D printing patient-matched artificial vertebral body in clinical research and application.Methods:A total of 12 patients with spinal tumors were enrolled 7 males (58.33%) and 5 females (41.67%), aged from 18 to 65 years old in The First Affiliated Hospital of Air Force military Medical University (hereinafter referred to as Xijing Hospital) and Peking University people's Hospital from September 2021 to July 2022. The spinal vertebra defect were restored by using 3D printing patient-matched artificial vertebral body after tumor resection. All patients who accepted TES and 3D printing patient-matched artificial vertebral body implantation were included according to the inclusion and exclusion criteria. The bone interface fusion was evaluated by the imaging fusion criteria of Brantigan and Steffee at 3 and 6 months after operation, the curative effect was evaluated by comparing Japanese Orthopaedic Association (JOA) score at 3 and 6 months after operation, visual analogue scale (VAS) 3 months after operation and intervertebral height at 3 and 6 months after operation with those before operation, and the safety was evaluated by adverse event recording.Results:All 12 patients completed the operation successfully, and the operation sites were thoracic vertebrae in 6 cases (50%), thoracolumbar in 3 cases (25%) and lumbar vertebrae in 3 cases (25%). All patients were followed up. The mean follow-up time was 23.92±3.23 months (range, 19-29 months). No tumor recurrence or metastasis was observed during this period. All patients were followed up at 15 days, 3 months and 6 months after operation. During the 6-month follow-up, X ray results showed that interface of bone and the vertebral body were fused in all of the 12 patients, and the effective rate of fusion was 100%. The 95% confidence interval is calculated to be (75.6%-100%). Six months after operation, the improvement rate of JOA score was excellent in 10 cases, good in 1 case, poor in 1 case, and the excellent and good rate was 91.66%. The preoperative VAS score was 4.08 ±2.47, and during the 3-month follow-up, the VAS score was improved to 1.83 ±1.59. Compared with the preoperative VAS score, the difference was statistically significant ( t=2.635, P=0.023). The intervertebral height before operation, 15 days after operation, 3 months after operation and 6 months after operation were 32.75 (25.94, 68.20), 41.09 (30.55, 70.20), 40.70 (30.23, 67.83) and 40.74 (30.23, 67.08), respectively, and there was no statistically significant difference (χ 2=0.768, P=0.857). No implant-related adverse events occurred after operation. Conclusion:The 3D printing patient-matched artificial vertebral body used in this study has satisfactory short-term efficacy and safety in the reconstruction of spinal stability after spinal tumor resection.
10.Construction and evaluation of an indicator system for nursing human resource efficiency in integrated medical and elderly care institutions using Data Envelopment Analysis
Mingxin HE ; Yanyan LI ; Yalou YANG ; Hongrui ZHU ; Shuhong GAO ; Shiming ZHOU ; Hua ZHANG ; Xiangdong ZHOU
Chinese Journal of Health Management 2024;18(2):99-106
Objective:To construct an evaluation indicator system for the efficiency of nursing human resources in integrated medical and elderly care institutions using Data Envelopment Analysis (DEA) and subsequently evaluate its effectiveness.Methods:This cross-sectional survey utilized literature review and investigative methods to initially establish a library of evaluation indicators for nursing human resource efficiency. The Delphi method was employed in two rounds of consultations with 17 experts from various fields, including nursing management, elderly care institution management, integrated medical and elderly care institution management, health economics management, and public health. The reliability of the indicator system was assessed based on factors such as expert enthusiasm, authority, concentration of opinions, and coordination. Adjustments, modifications, and improvements were made to the indicators based on expert opinions to establish the final indicator system. From August to December 2022, the DEA model was applied to evaluate the efficiency of 12 integrated medical and elderly care institutions in Haikou city based on this indicator system.Results:The constructed evaluation indicator system comprised 68 items divided into three levels: 9 primary indicators, 19 secondary indicators, and 40 tertiary indicators. The positive coefficients of the two rounds of expert consultations were 100% and 94.1%, with authority coefficients of 0.88 and 0.92, Kendall harmony coefficients of 0.471 and 0.348, and mean coefficients of variation of 0.16 and 0.12 ( P<0.001). DEA evaluation results for the 12 integrated medical and elderly care institutions showed that 5 were DEA effective institutions with comprehensive efficiency (OE), technical efficiency (TE), and scale efficiency (SE) values all equal to 1.000, while 7 were non-DEA effective institutions, including 4 with SE <1.000 but TE=1.000 and 3 with both SE and TE<1.000. Conclusions:The constructed evaluation indicator system demonstrates high enthusiasm, authority coefficients, and coordination in expert consultations, indicating high acceptability and comprehensive content with distinct levels and strong specialty characteristics. The DEA model′s evaluation results objectively and effectively reflect the efficiency of nursing human resources in integrated medical and elderly care institutions, demonstrating practical utility.

Result Analysis
Print
Save
E-mail