1.Research progress on artificial intelligence application in the perioperative period of cardiovascular surgery
Hong JIANG ; Zeye LIU ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):54-59
With the advancement and development of computer technology, the medical decision-making system based on artificial intelligence (AI) has been widely applied in clinical practice. In the perioperative period of cardiovascular surgery, AI can be applied to preoperative diagnosis, intraoperative, and postoperative risk management. This article introduces the application and development of AI during the perioperative period of cardiovascular surgery, including preoperative auxiliary diagnosis, intraoperative risk management, postoperative management, and full process auxiliary decision-making management. At the same time, it explores the challenges and limitations of the application of AI and looks forward to the future development direction.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Novel X-Clip transcatheter edge-to-edge repair system for treating severe functional mitral regurgitation: The first case report
Jiaqi DAI ; Da ZHU ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):567-570
For patients with moderate-to-severe functional mitral regurgitation (FMR) who continue to experience heart failure symptoms despite optimized medical and device therapy, transcatheter mitral valve edge-to-edge repair (TEER) is increasingly becoming a reliable treatment option. With the continuous research and development and improvement of TEER-related devices, there are currently dozens of domestically developed TEER devices undergoing clinical trials in China. In this study, we report the first case of a patient with severe FMR treated with the X-Clip® TEER system. The patient, a 60-year-old male, suffered FMR attributed to dilated cardiomyopathy. Preoperative transthoracic echocardiography showed severe mitral regurgitation (4+). He underwent percutaneous repair using the X-Clip® system, and immediate postoperative ultrasound showed mild mitral regurgitation. At the 1-month follow-up, the patient’s symptoms and New York Heart Association (NYHA) functional class improved, and a follow-up transthoracic echocardiogram showed mild mitral regurgitation (1+).
7.Reconstruction and analysis of K-Clip surgery process based on finite element method
Hao SHI ; Wenbin OUYANG ; Shiguo LI ; Qi LI ; Fengwen ZHANG ; Yao LIU ; Wenxin LU ; Chang LIU ; Shaojie ZHANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(01):44-50
Objective To investigate the effects of different types of tricuspid regurgitation, implantation positions, and device models on the treatment outcomes of K-Clip for tricuspid regurgitation using numerical simulations. Methods Three-dimensional reconstruction of the heart model was performed based on CT images. Two different regurgitation orifices were obtained by modifying the standard parameterized tricuspid valve leaflets and chordae tendineae. The effects of different K-Clip models at different implantation positions (posterior leaflet midpoint, anterior-posterior commissure, anterior leaflet midpoint, posterior septal commissure) were simulated using commercial explicit dynamics software Ls-Dyna. Conclusion For the two types of regurgitation in this study, clipping at the posterior leaflet midpoint resulted in a better reduction of the regurgitation orifice (up to 75% reduction in area). Higher clamping forces were required for implantation at the anterior leaflet midpoint and posterior septal commissure, which was unfavorable for the smooth closure of the clipping components. There was no statistical difference in the treatment outcomes between the 18T and 16T K-Clip components, and the 16T component required less clamping force. Therefore, the use of the 16T K-Clip component is recommended.
8.Echo-guiding percutaneous aortic stent implantation for coarctation of the aortic: A case report
Junke CHANG ; Peijian WEI ; Yaoxing LU ; Fengwen ZHANG ; Fang FANG ; Chuangshi WANG ; Shouzheng WANG ; Wenbin OUYANG ; Junyi WAN ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):325-328
Currently, transcatheter intervention has emerged as a first-line treatment for coarctation of the aortic. Due to the radiation exposure associated with catheter interventional therapy, there are numerous restrictions, which harms both patients and medical personnel and is dependent on sizable radiation apparatus. Here, we report for the first time a case of echo-guiding percutaneous aortic stent implantation for a 27 years female patient of reproductive age. After discharge, the patient's aortic coarctation pressure decreased to 18 mm Hg, and the surgical results were satisfactory.
9.Analysis of Cardiac Reverse Remodeling After Transcatheter Edge-to-edge Repair of Mitral Regurgitation due to Various Etiologies and Experience of Echocardiography Application
Zhiling LUO ; Xiaoli DONG ; Qiuzhe GUO ; Yuanzheng WANG ; Jin LI ; Yunfei ZHOU ; Shuanglan YU ; Da ZHU ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2024;39(3):234-241
Objectives:To evaluate the valvular and cardiac function,cardiac reverse remodeling at 6-month after transcatheter edge-to-edge repair(TEER)for patients with functional and degenerative mitral valve regurgitation,and summarize the experience of echocardiography application. Methods:The clinical data of 93 patients with moderate to severe mitral regurgitation(MR)treated with TEER and completed 6-month follow-up in Yunnan Fuwai Cardiovascular Hospital from July 2022 to February 2023 were retrospectively analyzed.Patients were divided into functional mitral regurgitation(FMR)and degenerative mitral regurgitation(DMR)groups according to MR etiology.The valve characteristic parameters,as well as valvular function,chamber volume and cardiac functional parameters before and at 6 months after operation were compared.The key points of echocardiography application were summarized. Results:Among all patients,71 were FMR and 22 were DMR.There were differences in valve structure between the two groups.Mitral TEER were successfully accomplished and all patients completed 6-month follow-up.The key points of echocardiography application included:valve structure analysis,atrial septal puncture location,device delivery process monitoring and image optimization during clamping process.The mitral regurgitation grade and NYHA grade were significantly improved in all patients at 6 months after TEER(P<0.05),and the mean mitral valve pressure gradient was higher than that before operation(P<0.05).Left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV)and left atrial volume index in FMR group were significantly decreased(P<0.05),while left ventricular and left atrial volume in DMR group remained unchanged(P>0.05).There were no significant changes in left ventricular ejection fraction and left ventricular global strain in both groups during the observation period(P>0.05).The changes of LVEDV and LVESV before and after operation were more significant in FMR group than those in DMR group(P<0.05). Conclusions:Mitral TEER can reduce the degree of regurgitation and improve cardiac function in the early postoperative period for moderate and severe MR patients with different etiologies.There are differences in preoperative valve structure and postoperative cardiac reverse remodeling between FMR and DMR patients.Echocardiography is an important imaging technique for the evaluation and monitoring process before,during and post mitral TEER.
10.Postoperative management of cardiac and vascular surgery in the period of COVID-19
Shuo CHANG ; Xinyi ZHANG ; Sheng HUANG ; Yuxin FAN ; Xiangbin PAN ; Xiaoqi WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(07):967-973
Objective To explore the postoperative characteristics and management experience of patients with coronavirus disease 2019 (COVID-19) undergoing cardiac and vascular surgery. Methods From December 7, 2022 to January 5, 2023, the patients with COVID-19 who were admitted to Cardiovascular Hospital Affiliated to Kunming Medical University and underwent cardiac and vascular surgery were selected. The clinical history, surgical information, postoperative recovery process and treatment plan were analyzed retrospectively. Results There were 18 patients in this group, including 11 (61.1%) males and 7 (38.9%) females, with an average age of 58.1±10.9 years. There were 7 patients of hypertension, 5 patients of diabetes, 3 patients of respiratory diseases, and 2 patient of chronic renal insufficiency. There were 5 (27.8%) patients receiving emergency operations and 13 (72.2%) elective operations. All the 18 patients underwent cardiac and vascular surgery in the period of COVID-19, and the time between the last positive nucleic acid test and the surgery was 1.50 (1.00, 6.25) days. There were 8 patients of pulmonary imaging changes, including 3 patients with chest patch shadow, 3 patients with thickened and disordered lung markings, and 2 patients with exudative changes before operation. Antiviral therapy was not adopted in all patients before operation. Three patients were complicated with viral pneumonia after operation, including 2 patients with high risk factors before operation, who developed into severe pneumonia after operation, and underwent tracheotomy. One patient with thrombus recovered after anticoagulation treatment. Another patient of mild pneumonia recovered after antiviral treatment. The other 15 patients recovered well without major complications. There was no operation-related death in the whole group. One patient died after surgery, with a mortality rate of 5.6%. Conclusion Patients with COVID-19 are at high risk of cardiac and vascular surgery, and patients with high-risk factors may rapidly progress to severe pneumonia. Patients with preoperative lung imaging changes or other basic visceral diseases should consider delaying the operation. Early antiviral combined with immunomodulation treatment for emergency surgery patients may help improve the prognosis.