1.Evaluation of molecular point-of-care testing for rapid diagnosis of influenza A virus and influenza B virus
Xiaodong SONG ; Guojun CAO ; Min ZHU ; Yu CHEN ; Kun CHEN ; Jin XIANG ; Meijuan LU
International Journal of Laboratory Medicine 2024;45(2):146-149,154
Objective To evaluate the performance of two molecular point-of-care testing(POCT)prod-ucts in the diagnosis of influenza A virus(Flu A)and influenza B virus(Flu B)of clinical samples,and pre-liminarily evaluate the clinical diagnostic value of the changes of infection-related indicators in peripheral blood.Methods A total of 491 oropharyngeal swabs from patients with influenza-like symptoms who were treated in the hospital were recruited into this study from November 1,2019 to June 30,2023.These swabs were collected using reverse transcription real-time quantitative fluorescent polymerase chain reaction(RT-qPCR),and two POCT molecular products,XpertTM Xpress Flu/RSV and EasyNAT? Flu Assay,respectively.The diagnostic performance of two POCT molecular products was analyzed using RT-qPCR reaction as a standard.According to the results of RT-qPCR method,the subjects were divided into Flu A positive group,Flu B positive group and negative group(both Flu A and Flu B were negative).The levels of indicators in pe-ripheral blood of the three groups were compared to evaluate the value of these indicators in the clinical diag-nosis of Flu A and Flu B.Results Among the 491 patient specimens,the XpertTM Xpress Flu/RSV assay showed the sensitivity for Flu A was 96.88%,and the specificity was 99.75%,and the sensitivity for Flu B was 100.00%,and the specificity was 100.00%.EasyNAT? Flu Assay assay showed the sensitivity for Flu A was 94.79%,and the specificity was 96.81%,and the sensitivity for Flu B was 100.00%,and the specificity was 100.00%.And two POCT molecular methods performed well consistency(Kappa value was 0.974).There was no significant difference in the levels of C-reactive protein and serum amyloid A among the negative group,Flu A positive group,and Flu B positive group(P>0.05).But the levels of white blood cell count in the negative group were higher than those in the Flu A positive group and Flu B positive group(P<0.01).Conclusion In this paper,two typical molecular POCT products are studied.Their sensitivity and specificity are highly consistent with the results of RT-qPCR.Molecular POCT products have the advantages of flexibil-ity and rapidity,which are of great value for the improvement of clinical diagnosis and treatment.Molecular detection combined with peripheral blood infection related indicators is helpful for the early diagnosis of influ-enza virus infectious diseases.
2.Network pharmacology and molecular docking to explore the mechanism of antiplatelet drugs in the treatment of acute lung injury
Jing NIU ; Qian XIANG ; Zhi-Yan LIU ; Zhe WANG ; Lin-Yu CAO
The Chinese Journal of Clinical Pharmacology 2024;40(6):914-917
Objective To explore the mechanism of antiplatelet drugs in the treatment of acute lung injury based on the strategy of network pharmacology.Methods The targets of antiplatelet drugs were predicted by SwissTargetPrediction platform,and the related targets of acute lung injury were obtained by GeneCards and OMIM databases.The protein interaction network was constructed through the STRING platform.The CytoHubba and MCODE plug-ins in Cytoscape software were used to screen out the core targets and highly connected target clusters for the treatment of acute lung injury.The DAVID database was used to analyze the gene ontology(GO)bioprocess and Kyoto encyclopedia of genes and genomes(KEGG)signaling pathway enrichment of the core targets.Finally,AutoDockTools software was used for molecular docking verification.Results A total of 20 core targets for antiplatelet drugs in the treatment of acute lung injury were screened,among which the top three core targets were proto-oncogene tyrosine-protein kinase(SRC),phosphoinositide-3-kinase regulatory subunit 1(PIK3R1)and signal transducer and activator of transcription 3(STAT3).Antiplatelet drugs may play a role in the treatment of acute lung injury by regulating epidermal growth factor receptor(ErbB)signaling pathway,positive programmed death receptor-1(PD-1)/programmed death receptor ligand-1(PD-L1)signaling pathway and Janus activated kinase/signal transducer and activator of transcription(JAK-STAT)signaling pathway.Molecular docking results further showed that antiplatelet drugs could bind well to core targets.Conclusion This study elucidated the possible mechanism of antiplatelet drugs in the treatment of acute lung injury from a systematic and holistic perspective,and provided new ideas for further study of the pharmacological mechanism of antiplatelet drugs in the treatment of acute lung injury.
3.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.
4.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
5.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
6.X-linked recessive ichthyosis with recurrent fungal keratitis:a case report
Lan YU ; Jiao QIN ; Feng-Jiao LONG ; Xiang-Xi CHEN ; Shang-Cao WU
Chinese Journal of Infection Control 2024;23(8):1037-1039
Ichthyosis is a hereditary dyskeratotic skin disease with systemic skin dryness and roughness,mainly manifested by scaly skin,which may be accompanied by ocular abnormalities.At present,there are many studies on skin fungal infection caused by ichthyosis,but only few reports on cases with combined ocular fungal infection.This paper reports a case of X-linked recessive hereditary ichthyosis with recurrent fungal keratitis(FK),which is expec-ted to provide reference for clinical early diagnosis and treatment of this disease.
7.Application of KIH Structure in Recombinant Expression of Human Interleukin-35 in vitro
Kai-Yue ZHANG ; Zong-Yan LI ; Rui-Qing CAO ; Lin-Lin MENG ; Xiang-Wei HU ; Yu-Chao GU ; Jian-Gang WANG
Chinese Journal of Biochemistry and Molecular Biology 2024;40(6):857-866
Interleukin-35(IL-35)is an important immunosuppressive cytokine that has been shown to play a role in the immune response of various diseases.In this study,we cloned the coding sequence of human IL-35 gene,constructed single subunit expression vectors pXC17.4-p35 and pcDNA3.1(+)-EBI3,and co-transfected CHO-K1 cells to express IL-35 in vitro.No binding was found between subunits of p35 and EBI3.Knobs-into-Holes(KIH)can solve the problem of heavy chain mismatch of heterolo-gous antibodies.Therefore,expression vectors pXC17.4-p35-Fch and pcDNA3.1(+)-EBI3-Fck were constructed by fusing KIH structures on the basis of the original sequences to express the recombinant fu-sion protein of KIH-IL-35.The expression vectors of two subunits were exchanged at the same time to verify the influence of different vectors on the expression level of KIH-IL-35.The analysis of various pro-tein detection methods showed that the correct expression rate of KIH-IL-35 structure was significantly im-proved.Affinity purification of KIH-IL-35 was performed after large amount of expression,and the bind-ing activity of KIH-IL-35 to glycoprotein 130(gp130)was detected by ELISA.The results showed that the binding of KIH-IL-35 to gp130 was concentration dependent.The indirect activity of KIH-IL-35 and M1 cells was detected by cell activity assay.Further results showed that the inhibition rate of M1 cells in-creased in a dose-dependent manner with the concentration of KIH-IL-35.In addition,a method for de-termining IL-35 activity by activated human peripheral blood mononuclear cells was successfully estab-lished.Activated PBMCs increased in a dose-dependent manner with KIH-IL-35 concentration.In sum-mary,this study utilized the KIH-IL-35 model to enhance the expression of recombinant human IL-35 and validated its high activity in vitro,providing new ideas for the study of IL-35 and the recombinant expres-sion of similar heterodimeric cytokines.
8.Study on inhibitory effect of alisol B on non-small cell lung cancer based on network pharmacology and its mechanism
Liu-Yan XIANG ; Wen-Xuan WANG ; Si-Meng GU ; Xiao-Qian ZHANG ; Lu-Yao LI ; Yu-Qian LI ; Yuan-Ru WANG ; Qi-Qi LEI ; Xue YANG ; Ya-Jun CAO ; Xue-Jun LI
Chinese Pharmacological Bulletin 2024;40(12):2375-2384
Aim To explore the potential genes and mechanism of alisol B in the treatment of non-small cell lung cancer(NSCLC).Methods The proliferation and migration of NSCLC cells were detected by CCK-8 and Transwell.Genes of NSCLC and alisol B were col-lected through TCGA and compound gene prediction database,and their intersection genes were obtained.The network of protein-protein interaction(PPI)was constructed by using String database,and the top 20 key nodes were screened out,and the prognosis-related proteins related to the prognosis of NSCLC were screened out by using R language,and the intersection of them was obtained.The potential mechanism of ali-sol B on NSCLC was explored by KEGG and GO en-richment analysis and the relationship between related genes and immune cells,which was verified by cell-lev-el experiments.Results Alisol B inhibited the cell activity and migration ability of NSCLC cells.Five im-portant genes were identified by network pharmacologi-cal analysis:CCNE1,CDK1,COL1A1,COL1A2 and COL3A1.The results of cell experiment showed that al-isol B down-regulated the expression of Cyclin E1,CDK1 and COL1A2 in NSCLC cells.In addition,alisol B could inhibit the expression of COL1A2 and M2 macrophage marker CD206 in macrophages.Conclu-sions Alisol B may inhibit the proliferation of tumor cells by down-regulating CDK1 and Cyclin E1,and may affect the function of macrophages by inhibiting COL1A2,thus regulating the tumor immune microenvi-ronment and inhibiting NSCLC.
9.Efficacy comparison between pneumovesicoscopic Cohen and Politano-Leadbetter technique in transvesicoscopic ureteral reimplantation in children
Changkun MAO ; Yongsheng CAO ; Han CHU ; Bo PENG ; Xiang LIU ; Xin YU ; Chengpin TAO ; Qifei DENG ; Tao ZHANG ; Chao YANG
Chinese Journal of Applied Clinical Pediatrics 2023;38(3):221-225
Objective:To compare the efficacy of pneumovesicoscopic Cohen and Politano-Leadbetter procedures in the treatment of vesicoureteral junction obstruction (VUJO) in children.Methods:The data of 48 children with VUJO who underwent operations in the Department of Urology, Anhui Provincial Children′s Hospital from January 2017 to December 2021 were retrospectively analyzed.According to the operation time, the patients were divided into the pneumovesicoscopic Cohen group(group C) (28 cases) and pneumovesicoscopic Politano-Leadbetter group(group P) (20 cases). The operation time, postoperative urinary catheterization duration, hematuria duration, hospitalization time, and the improvement of hydronephrosis, ureteral dilatation, and renal function after surgery were compared between the 2 groups.The enumeration data were compared by the χ2 test or Fisher′ s exact probability method.The measurement data were compared by the t-test. Results:All the 48 children were successfully operated on by the same surgeon, without conversion to open surgery.Six cases in the group C had a megaureter and underwent ureter tailoring.Two cases in the group P had calyceal and ureteral calculi, which were all removed after operation.There was a statistically significant difference in the operation time between group C and group P[(136.5±35.4) min vs.(165.8±33.2) min, t=-3.154, P=0.002]. The patients were followed up for (10.3±2.6) months after operation.There were 8 cases and 6 cases of urinary tract infection in group C and group P within 2 months after the operation, respectively.They all improved after conservative anti-infection treatment, and the infection was well controlled after removal of the D-J tube.Besides, their intravenous pyelography 6 months after operation showed that the ureter was unobstructed.In group C, 6 months after the operation, the anterior and posterior diameters of the renal pelvis [(1.62±0.54) cm vs.(2.55±1.24) cm, t=-5.027, P=0.001] and the largest diameter of the ureter [(0.95±0.27) cm vs.(1.51±0.52) cm, t=-8.495, P<0.001] were significantly decreased, compared with those before operation.However, the renal cortex thickness was increased significantly [(1.47±0.25) cm vs.(0.86±0.46) cm, t=2.028, P=0.004], and the renal function (as indicated by the diuretic nephrogram) was notably improved [(46.27±2.16)% vs.(41.83±3.04)%, t=1.647, P=0.030]. In group P, 6 months after operation, the anterior and posterior diameters of the renal pelvis[(1.48±0.82) cm vs.(2.68±1.41) cm, t=-2.740, P=0.003] and the maximum diameter of the ureter [(1.05±0.46) cm vs.(1.36±0.27) cm, t=-1.635, P=0.040] were significantly smaller than those before operation.However, the renal cortical thickness was increased [(1.38±0.33) cm vs.(0.74±0.39) cm, t=9.073, P<0.001], and the renal function (as indicated by the diuretic nephrogram) was significantly improved [(45.18±3.35)% vs.(39.55±2.49)%, t=1.277, P=0.030]. Politano-Leadbetter surgery outperformed Cohen surgery in promoting the recovery of the anterior and posterior diameters of the renal pelvis [(1.48±0.82) cm vs.(1.62±0.54) cm, t=-1.748, P=0.030]. Conclusions:Pneumovesicoscopic Politano-Leadbetter operation can establish a longer submucosal tunnel without changing the ureteral shape and opening position, having good effects in treating VUJO combined with calyceal and ureteral calculi.Pneumovesicoscopic Politano-Leadbetter operation can also better improve postoperative recovery from hydronephrosis than Cohen operation.However, the pneumovesicoscopic Politano-Leadbetter operation is more difficult and requires longer time.The surgeon should choose a reasonable operation based on his/her own experience.
10.Comparative study of corneal thickness and thinnest point position of keratoconus measured by Pentacam HR and RTVue OCT
Yu-Miao PAN ; Shang-Cao WU ; Wan-Ju YANG ; Xiang-Xi CHEN ; Jiao QIN ; Juan WANG ; Lan YU
International Eye Science 2023;23(6):1012-1016
AIM: To investigate the difference, correlation, and consistency of corneal thickness and the thinnest point position detected by Pentacam HR corneal topography map and RTVue optical coherence tomography(OCT)in patients with keratoconus.METHODS: Cross-sectional comparative study. The corneal curvature map, corneal thickness map, thinnest point position, and thinnest point thickness were detected by Pentacam HR and RTVue OCT. Paired sample t-test was used for data consistent with normal distribution, and paired sample rank sum test was used for data inconsistent with normal distribution. Spearman correlation analysis and Bland-Altman analysis were used for the correlation and consistency of the two measurement methods.RESULTS: A total of 63 patients(105 eyes)with keratoconus were included in this study, including 49 males(77.8%)and 14 females(22.2%), aged 22.24±6.19 years; among them, relevant data of Pentacam HR topographic map: Km was 47.85±4.73D and Kmax was 55.43±8.72D. In measuring central corneal thickness and the thinnest point thickness of keratoconus, the Pentacam HR was 4.70μm and 19.46μm thicker than the mean value measured by RTVue OCT(P<0.05). There was no significant difference between the horizontal and vertical coordinates of the thinnest points measured by the two devices(P>0.05). The central corneal thickness and the thinnest point thickness measured by the two devices were highly correlated, the horizontal coordinate of the thinnest point was moderately correlated, and the vertical coordinate of the thinnest point was weakly correlated. Bland-Altman analysis showed that the central corneal thickness, the thinnest point thickness, the horizontal coordinate of the thinnest point, and the vertical coordinate of the thinnest point were 95.2%(100/105)and 93.3%(98/105), 95.2%(100/105), 95.2%(100/105)respectively, which were within the 95% consistency limit, while the consistency ranges were -36.00~+26.62μm, -42.27~+3.36μm, -0.80~+0.84mm, and -1.95~+1.06mm, respectively.CONCLUSION: In keratoconus, the central corneal thickness and the thinnest point thickness measured by Pentacam HR were higher than those measured by RTVue OCT. It is not recommended that the central corneal thickness and the thinnest point thickness measured by the two instruments be interchangeable in clinical use because of the wide range of consistency between the two instruments' results. The position of the thinnest corneal point measured by the two instruments is similar and consistent, so it could be considered to replace the measured values of the two instruments in clinical use.

Result Analysis
Print
Save
E-mail