1.Establishment and Application of a Duplex Real Time Fluorogenic Quantitative PCR Assay System for miR-451a and miR-21-5p
Shu-Xiao HU ; Hui-Xiang CHEN ; Sheng HU ; Yi-Xia ZHAO ; An-Quan JI ; Yang LI ; Jie LIAN ; Qi-Fan SUN
Progress in Biochemistry and Biophysics 2024;51(3):706-715
ObjectiveBody fluid stains left at crime scenes are frequently trace amounts, while the identification of body fluids through real time fluorogenic quantitative technique often necessitates the repeated detection within the limited sample, as multiple miRNA markers are the basis for the identification. Based on the goal of both the throughput and efficiency improvement of miRNA analysis in trace samples, a duplex real time fluorogenic quantitative PCR assay system was designed to accurately quantify two miRNAs simultaneously, and the system should be further verified by actual sample for the body fluid identification. MethodsThe duplex real time fluorogenic quantitative PCR system of miR-451a to miR-21-5p was established with specially designed primers and probes, and the concentrations of the primers and probes were both optimized. The specificity, sensitivity and reproducibility of the system were validated, while its capability for body fluid identification was assessed using the miR-451a to miR-21-5p ratio. ResultsThe optimized assay system exhibited excellent specificity and repeatability, with coefficients of variation consistently below 8% for both intra- and inter-batch variability. The amplification efficiency of miR-451a and miR-21-5p reached 71.77% and 74.81%, respectively, with high and relatively consistent results. By utilizing this duplex real time fluorogenic quantitative PCR assay system, a total of 58 body fluid samples were analyzed, exhibiting a discrimination rate of 100% between blood and non-blood samples, as well as between peripheral blood and menstrual blood samples. Moreover, the results, obtained from single real time fluorogenic quantitative PCR assay system and duplex real time fluorogenic quantitative PCR assay system, showed no statistically significant difference with randomly selected blood samples (n=20). Compared to previous single real time fluorogenic quantitative PCR assay system, the sensitivity of duplex real time fluorogenic quantitative PCR assay system exhibited remarkable improvement. A minimum input of only 0.1 ng total RNA was sufficient for accurate detection of peripheral blood and menstrual blood samples, while saliva, semen, and vaginal secretion required only 1 ng total RNA for precise identification purposes. Additionally, the duplex real time fluorogenic quantitative PCR assay system successfully differentiated between different types of body fluids in simulated samples under natural outdoor conditions. ConclusionThe duplex real time fluorogenic quantitative PCR assay system effectively reduced both the time and material costs by half compared to the single system, especially suitable for the examination of body fluid stains left at crime scenes, solving the contradiction between the trace amount and the multiple sample volumes demand of repeated real time fluorogenic quantitative PCR. The duplex real time fluorogenic quantitative PCR assay successfully distinguished blood and other body fluid, as well as peripheral blood and menstrual blood samples, which maintains an equivalent capability for body fluid identification with half sample, time and reagent consumption. This system provides an efficient tool for identifying suspicious body fluids, as well as a foundation for more multiplexed real time fluorogenic quantitative PCR assay system research.
2.Hypericin inhibits the expression of NLRP3 in microglia of Parkinson's disease mice and alleviates the damage of DA-ergic neurons
Li-Shan FAN ; Jia ZHANG ; Si-Xiang NIU ; Qi XIAO ; Hui-Jie FAN ; Lei XU ; Li-Xia YANG ; Lu JIA ; Shao-Chen QIN ; Bao-Guo XIAO ; Cun-Gen MA ; Zhi CHAI
The Chinese Journal of Clinical Pharmacology 2024;40(17):2523-2527
Objective To observe the intervention effect of hypericin(HYP)on 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine(MPTP)-induced Parkinson's disease(PD)mice model and its mechanism.Methods Thirty C57BL/6 mice were randomly divided into normal,model and experimental groups with 10 mice per group.PD mouse model was established after 7 days of intraperitoneal injection of MPTP,and drug intervention was carried out from the first day of modeling.Normal group and model group were intraperitoneally injected with 500 μL·kg·d-1 0.9%NaCl.The experimental group was intraperitoneally injected with 25 mg·kg·d-1 HYP.The three groups of rats were given the drug once each time for 14 days.The expression levels of tyrosine hydroxylase(TH),Nod-like receptor thermal protein domain protein 3(NLRP3)and ionized calcium binding adapter molecule 1(Iba1)in the striatum of nigra were detected by Western blot.Results The climbing time of normal,model and experimental groups was(5.35±0.43),(9.71±1.19)and(8.07±0.34)s;suspension scores were(2.92±0.15),(1.38±0.28)and(1.96±0.28)points;the relative expression levels of TH protein were 1.04±0.06,0.51±0.09 and 0.75±0.07;the relative expression levels of NLRP3 protein were 0.51±0.03,1.00±0.04 and 0.77±0.06;the relative expression levels of Iba1 protein were 0.68±0.10,1.30±0.28 and 0.89±0.05,respectively.The above indexes in the model group were statistically significant compared with the experimental group and the normal group(all P<0.01).Conclusion HYP plays a therapeutic role in PD by inhibiting the expression of NLRP3 inflammasome in PD mice.
3.Th17/Treg balance and macrophage polarization ratio in lower extremity arteriosclerosis obliterans
Zhen-Zhen Li ; Min Liu ; Xiong-Hui He ; Zhen-Dong Liu ; Zhan-Xiang Xiao ; Hao Qian ; You-Fei Qi ; Cun-Chuan Wang
Asian Pacific Journal of Tropical Biomedicine 2024;14(3):127-136
Objective: To explore the balance of peripheral blood T helper 17 cells/regulatory T cell (Th17/Treg) ratio and the polarization ratio of M1 and M2 macrophages in lower extremity arteriosclerosis obliterans (ASO). Methods: A rat model of lower extremity ASO was established, and blood samples from patients with lower extremity ASO before and after surgery were obtained. ELISA was used to detect interleukin 6 (IL-6), IL-10, and IL-17. Real-time RCR and Western blot analyses were used to detect Foxp3, IL-6, IL-10, and IL-17 expression. Moreover, flow cytometry was applied to detect the Th17/Treg ratio and M1/M2 ratio. Results: Compared with the control group, the iliac artery wall of ASO rats showed significant hyperplasia, and the concentrations of cholesterol and triglyceride were significantly increased (P<0.01), indicating the successful establishment of ASO. Moreover, the levels of IL-6 and IL-17 in ASO rats were pronouncedly increased (P<0.05), while the IL-10 level was significantly decreased (P<0.05). In addition to increased IL-6 and IL-17 levels, the mRNA and protein levels of Foxp3 and IL-10 in ASO rats were significantly decreased compared with the control group. The Th17/Treg and M1/M2 ratios in the ASO group were markedly increased (P<0.05). These alternations were also observed in ASO patients. After endovascular surgery (such as percutaneous transluminal angioplasty and arterial stenting), all these changes were significantly improved (P<0.05). Conclusions: The Th17/Treg and M1/M2 ratios were significantly increased in ASO, and surgery can effectively improve the balance of Th17/Treg, and reduce the ratio of M1/M2, and the expression of inflammatory factors.
4.Investigation and analysis of the current status of transjugular intrahepatic portosystemic shunt treatment for portal hypertension in China
Haozhuo GUO ; Meng NIU ; Haibo SHAO ; Xinwei HAN ; Jianbo ZHAO ; Junhui SUN ; Zhuting FANG ; Bin XIONG ; Xiaoli ZHU ; Weixin REN ; Min YUAN ; Shiping YU ; Weifu LYU ; Xueqiang ZHANG ; Chunqing ZHANG ; Lei LI ; Xuefeng LUO ; Yusheng SONG ; Yilong MA ; Tong DANG ; Hua XIANG ; Yun JIN ; Hui XUE ; Guiyun JIN ; Xiao LI ; Jiarui LI ; Shi ZHOU ; Changlu YU ; Song HE ; Lei YU ; Hongmei ZU ; Jun MA ; Yanming LEI ; Ke XU ; Xiaolong QI
Chinese Journal of Radiology 2024;58(4):437-443
Objective:To investigate the current situation of the use of transjugular intrahepatic portosystemic shunt (TIPS) for portal hypertension, which should aid the development of TIPS in China.Methods:The China Portal Hypertension Alliance (CHESS) initiated this study that comprehensively investigated the basic situation of TIPS for portal hypertension in China through network research. The survey included the following: the number of surgical cases, main indications, the development of Early-TIPS, TIPS for portal vein cavernous transformation, collateral circulation embolization, intraoperative portal pressure gradient measurement, commonly used stent types, conventional anticoagulation and time, postoperative follow-up, obstacles, and the application of domestic instruments.Results:According to the survey, a total of 13 527 TIPS operations were carried out in 545 hospitals participating in the survey in 2021, and 94.1% of the hospital had the habit of routine follow-up after TIPS. Most hospitals believed that the main indications of TIPS were the control of acute bleeding (42.6%) and the prevention of rebleeding (40.7%). 48.1% of the teams carried out early or priority TIPS, 53.0% of the teams carried out TIPS for the cavernous transformation of the portal vein, and 81.0% chose routine embolization of collateral circulation during operation. Most of them used coils and biological glue as embolic materials, and 78.5% of the team routinely performed intraoperative portal pressure gradient measurements. In selecting TIPS stents, 57.1% of the hospitals woulel choose Viator-specific stents, 57.2% woulel choose conventional anticoagulation after TIPS, and the duration of anticoagulation was between 3-6 months (55.4%). The limitation of TIPS surgery was mainly due to cost (72.3%) and insufficient understanding of doctors in related departments (77.4%). Most teams accepted the domestic instruments used in TIPS (92.7%).Conclusions:This survey shows that TIPS treatment is an essential part of treating portal hypertension in China. The total number of TIPS cases is far from that of patients with portal hypertension. In the future, it is still necessary to popularize TIPS technology and further standardize surgical indications, routine operations, and instrument application.
5.Quality evaluation of childhood autism guidelines/consensus based on AGREE Ⅱ and RIGHT
Hui DENG ; Meng-Qi WANG ; Xiang-Ran MENG ; Zheng-Li LONG ; Xue CAO ; Jia LIU
Medical Journal of Chinese People's Liberation Army 2024;49(9):977-985
Objective To evaluate the methodological and reporting quality of published guidelines/consensus for childhood autism(CA),providing a basis for formulating domestic CA guidelines.Methods We searched databases including CNKI,Wanfang Data,SinoMed,Medlive,PubMed,national institute of health and clinical excellence(NICE),national guideline clearinghouse(NGC),and Scottish intercollegiate guidelines network(SIGN)for Chinese and foreign guideline/consensus on childhood autism published before February 1,2024.Two researchers independently evaluated the methodology and reporting quality of the guideline/consensus using the Appraisal of Guidelines Research and Evaluation Ⅱ(AGREE Ⅱ)and Reporting Items for Practice Guidelines in Healthcare(RIGHT)tools.Results After literature screening,19 CA guidelines/consensus were included,comprising 11 guidelines,7 consensus,and 1 expert recommendation,with 9 domestic and 10 foreign articles.The AGREE Ⅱ evaluation scores for the six domains were as follows:scope and purpose(91.1%±4.5%),stakeholder involvement(86.8%±6.7%),rigour of development(83.0%±10.2%),clarity of presentation(84.3%±6.2%),applicability(82.7%±13.3%),and editorial independence(65.4%±21.8%).The RIGHT checklist reported rates for the seven domains were:basic information(87.6%±11.0%),background(87.6%±13.8%),evidence(81.1%±22.6%),recommendation(71.1%±38.4%),review and quality assurance(83.5%±16.7%),funding and declaration and management of interests(48.7%±29.4%),and other information(64.4%±11.8%).The domain with the lowest score for methodological quality was"editorial independence"and for reporting quality,it was"funding and declaration and management of interests".The reporting rate of domestic articles(26.2%±1.5%)was significantly lower than that of foreign articles(52.6%±2.2%),with a statistically significant difference(P<0.05).Conclusion The overall quality of current childhood autism guidelines/consensus requires improvement.During the formulation and reporting of guidelines/consensus,strictly adhering to AGREE Ⅱ and RIGHT is imperative,and it is essential to clearly report funding sources and conflicts of interest.
6.Carthamus tinctorius L.extract ameliorates alcoholic liver disease by modulating PI3K/Akt/FoxO signaling pathway
Wen-Xuan WANG ; Xiang-Lei FU ; Man QI ; Fu-Rong FAN ; Fu-Rong ZHU ; Yuan-Chuang WANG ; Kai-Yue ZHANG ; Min LIU ; Sheng-Hui CHU
Chinese Pharmacological Bulletin 2024;40(6):1137-1145
Aim To investigate the effects of Cartham-us tinctorius L.extract(CTLE)on oxidative stress,lipid metabolism,and apoptosis levels of mice with al-cohol-induced liver injury and its mechanism of action.Methods The mouse model of alcohol-associated liver disease was established by chronic alcohol feeding and acute alcohol gavage.Mice were randomly divided into four groups.During the modeling period,the state changes of mice were observed every day,and their weight was recorded.At the end of modeling,blood and liver tissues were collected from each group of mice.The blood of mice was analyzed biochemically,and HE staining and Oil Red O staining were used to evaluate further the degree of pathological damage in the liver of mice.Quantitative real-time PCR(qPCR)and Western blot were applied to detect the mRNA and protein expression levels of p-PI3K,PI3K,p-Akt,Akt,p-mTOR,mTOR,p-FoxO1,FoxO1,p-FoxO3a,FoxO3a,p-FoxO4,FoxO4,BCL and BAX factors.Results Compared to the model group,the CTLE administration group showed improved hepatic patho-logical injury and reduced lipid deposition.The bio-chemical indexes in serum and liver,such as ALT,AST,TG,TC,and MDA levels were reduced,while GSH and SOD levels increased.Regulating the PI3K/Akt/FoxO pathway resulted in increased production of SOD,which reduced damage and apoptosis caused by reactive oxygen species(ROS).Conclusions CTLE can exert anti-oxidative stress and anti-apoptotic effects through the PI3K/Akt/FoxO pathway and attenuates alcoholic liver injury in mice,providing new ideas for the treatment of alcoholic liver disease and the develop-ment of related drugs.
7.Chemical constituents from Codonopsis pilosula in Shanxi and their anti-inflammatory activities
Yan-Gang CHENG ; Pei LI ; Si-Qi YANG ; Xiang-Peng KONG ; Hui-Feng LI ; Yan WANG ; Jin-Yan TAN ; Ying-Li WANG
Chinese Traditional Patent Medicine 2024;46(7):2265-2271
AIM To study the chemical constituents from Codonopsis pilosula(Franch.)Nannf in Shanxi and their anti-inflammatory activities.METHODS The 70% ethanol extract from C.pilosula in Shanxi was isolated and purified by silica gel,ODS and preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.Their in vitro anti-inflammatory activities were evaluated by RAW264.7 model.RESULTS Sixteen compounds were isolated and identified as ethylsyringin(1),7-O-ethyltangshenoside Ⅱ(2),triandrin(3),trans-isoconiferin(4),methylsyringin(5),9-acetoxy syringin(6),cordifolioidyne B(7),codonopiloenynenoside A(8),codonopilodiynoside F(9),pratialin B(10),lobetyolinin(11),lariciresinol-4-O-β-D-glucoside(12),dihydrodehydrodiconiferyl alcohol 4′-O-β-D-glucoside(13),atractylenolid Ⅲ(14),baimantuoluoamide B(15),benzyl primeveroside(16).Compounds 1-2,5,7-11 and 13-15 had certain anti-inflammatory activities,among which compounds 11,14-15 had higher activities,whose IC50 values were(18.23±4.18),(17.73±3.12),(14.89±2.47)μmol/L,respectively.CONCLUSION Compounds 3,6,13,16 are first isolated from Campanulaceae,2,5,15 are first found from this plant.Compounds 11,14 and 15 have good anti-inflammatory activities.
8.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.
9.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.
10.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.


Result Analysis
Print
Save
E-mail