1.Follow up study on the association of anxiety and depressive symptoms with smartphone addiction among middle school students
JI Mingxia, YANG Jie, JIA Qu, DONG Ying, WANG Daosen, LI Zhumin, WEN Xiang, CHEN Qifei, LI Xiuhong
Chinese Journal of School Health 2025;46(9):1277-1281
Objective:
To investigate the changing trends for associations of anxiety and depressive symptoms with smartphone addiction among middle school students, so as to provide a scientific basis for preventing smartphone addiction in middle school students.
Methods:
From 2022 to 2023, a method of combining convenient sampling with cluster sampling was used to select 8 923 middle school students from 27 junior high schools and 3 senior high schools in a district of Shenzhen City between September 2022 (baseline, T1) and September 2023 (follow up, T2). The Smartphone Addiction Scale-Short Version (SAS-SV), Patients Health Questionnaire-9 Item (PHQ-9), and Generalized Anxiety Disorder 7-item Scale (GAD-7) were administered to assess smartphone addiction, anxiety and depressive symptoms. Mixed effects models were used to analyze the association of anxiety and depressive symptoms with smartphone addiction among middle school students.
Results:
From September 2022 to September 2023, the reported prevalence of smartphone addiction increased from 24.22% to 25.25% ( χ 2=45.71); and smartphone addiction scores [ 24.00 (16.00, 32.00),25.00(16.00, 33.00)], anxiety symptom scores [2.00(0.00, 7.00),3.00(0.00, 7.00)] and depressive symptom scores[3.00(0.00, 8.00),5.00(0.00, 9.00)] all significantly increased ( Z =-17.43, -42.38, -41.57) (all P <0.05). There were statistically significant difference in the distribution of anxiety and depression symptom levels among middle school students in 2022 and 2023 ( χ 2=85.15, 106.85, both P <0.05). After adjusting for covariates such as age, gender and family background, mixed effects models revealed dose response associations of anxiety and depressive symptoms with smartphone addiction among middle school students:mild anxiety symptom( OR =3.22), moderate to severe anxiety symptom ( OR =5.36), mild depressive symptom ( OR =3.32) and moderate to severe depressive symptom ( OR =6.13) were significantly associated with higher risks of smartphone addiction (all P <0.05). Interaction effect analysis found that co existing anxiety and depressive symptoms synergistically increased addiction risk by 5.60 times ( OR =5.60) compared to the asymptomatic group, with 32% of the combined risk attributable to their interaction ( S=1.64, AP =0.32)(both P < 0.05 ).
Conclusions
Anxiety and depressive symptoms are significantly associated with smartphone addiction, exhibiting a synergistic effect. Attention should be paid to emotional issues and smartphone addiction among middle school students.
2.Advances in therapeutic drug monitoring methods based on liquid chromatography-tandem mass spectrometry
Ziying LI ; Jie XIE ; Ziyu QU ; You JIANG ; Di ZHANG ; Songlin YU ; Xiaoli MA ; Ling QIU ; Xinhua DAI ; Xiang FANG ; Xiaoping YU
Chinese Journal of Laboratory Medicine 2024;47(3):332-340
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology has the characteristics of high specificity and high throughput, making it rapidly applied and developed in the field of clinical testing. Its application in the monitoring of therapeutic drugs can effectively improve the quantitative accuracy and sensitivity, and formulate a personalized and optimal dosing plan for patients. However, this technology still faces some challenges, and automation, quality control, and quantitative traceability will be the future development direction.
3.Research Advance on Smartphone-based Visual Biosensor in Point-of-Care Testing
Xian-Xin XIANG ; Hua-Yue SUN ; Hui-Ning CHAI ; Kun YU ; Li-Jun QU ; Guang-Yao ZHANG ; Xue-Ji ZHANG
Chinese Journal of Analytical Chemistry 2024;52(2):145-156
Human physiological indicators have become an important standard for assessing health in modern society.Traditional detection methods often require a separate laboratory,complex operation process and long detection time,so it is urgent to develop portable,fast and accurate on-site detection technologies for bioanalysis.Point-of-care testing(POCT),which differs from traditional laboratory testing,can realize the rapid in situ detection of biomarkers without the complicated analytical process of the laboratory.Smartphones,which are an essential tool in our daily life,not only have independent operating systems and built-in storage functions,but also have high-definition cameras,which have great application potential in POCT visualization.The combination of various biosensing technologies and smartphones has developed into a new direction in the field of POCT.This review mainly introduced the research progress of smartphone-based visual biosensors in POCT in recent years,including colorimetric sensors,fluorescence sensors,chemiluminescence sensors and electrochemiluminescence sensors.Finally,the problems faced by smart-phone-based visual biosensors in the application of POCT were summarized,and their future development was prospected.
4.Analysis of Material Basis of Famous Classical Formula Baoyuantang Based on UPLC-Q-TOF-MS/MS
Wenjing GAO ; Shanshan LI ; Xiaomei XIANG ; Yi SUN ; Yang QU ; Chunling ZHOU ; Shufan ZHOU ; Lun YU ; Bing LI ; Ping WANG ; Haiyu XU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(22):243-248
ObjectiveA rapid method for identification of chemical constituents in Baoyuantang reference sample was established in order to clarify the material basis of this formula. MethodBased on ultra-performance liquid chromatography-quadrupole-time-of-flight mass spectrometry(UPLC-Q-TOF-MS/MS) and self-established database information, the chemical components in Baoyuantang were systematically characterized and identified. The chromatography was performed on a Waters ACQUITY UPLC HSS T3 column(2.1 mm×100 mm, 1.8 μm) with mobile phase of 0.1% formic acid aqueous solution(A)-0.1% formic acid acetonitrile solution(B) for gradient elution(0-3 min, 2%-19%B; 3-8 min, 19%B; 8-8.1 min, 19%-22%B; 8.1-14 min, 22%-29%B; 14-16 min, 29%B; 16-32 min, 29%-45%B; 32-32.1 min, 45%-90%B; 32.1-35 min, 90%-95%B; 35-36 min, 95%-98%B; 36-37 min, 98%-2%B; 37-40 min, 2%B). Based on electrospray ionization(ESI), continuum data format was collected in both positive and negative ion modes with a scanning range of m/z 50-1 500. Chemical constituents in the decoction of Baoyuantang were systematically analyzed by UNIFI 1.9.4 software matching, control comparison, The Encyclopedia of Traditional Chinese Medicine(ETCM) database search and literature reports. ResultA total of 229 components were identified under negative ion mode and 181 under positive ion mode, with a total of 322 components after removing duplicates, including 116 triterpene saponins, 66 flavonoids, 19 organic acids, 6 gingerphenols, 6 gingerols, 5 gingerones, 10 amino acids, 7 saccharides, 5 coumarins and 82 other components. Among them, 83, 141, 39, 35 and 38 components were attributed to Ginseng Radix et Rhizoma, Glycyrrhizae Radix et Rhizoma, Astragali Radix, Cinnamomi Cortex and Zingiberis Rhizoma Recens, respectively. ConclusionIn this study, the rapid characterization and identification of multi-class components in Baoyuantang was realized, and it was confirmed that the material basis of this formula was mainly triterpenoid saponins, flavonoids, gingerols and organic acids, and the chemical composition was attributed and analyzed, which provided a reference for the subsequent quality control research.
5.Analysis of ethical issues related to medical digital twins
Chinese Medical Ethics 2024;37(6):686-692
As a"double-edged sword"in emerging medical science and technology,medical digital twins not only bring good news to clinical diagnosis and treatment,but also have a certain impact on the medical ethics system.This paper mainly discussed the ethical risks and challenges involved in the application of digital twins technology in the medical field,such as the scientificity and effectiveness of simulation experimental results,the autonomy of both doctors and patients,issues of privacy and life safety,and potential social injustice.Starting from the four principles of bioethics,such as respect,benefit,non-harm,and justice,this paper analyzed the current situation and explored prevention and treatment countermeasures or suggestions for solving the ethical issues of medical digital twins,with a view to achieving timely,accurate,and effective detection,prevention,and control,to better promote the rational development,innovative application,and healthy development of digital twins technology in the medical field.
6.Effect of Dexmedetomidine on Intraoperative Hemodynamics and Blood Loss in Patients Undergoing Spine Surgery:A Systematic Review and Meta-Analysis
Wang MEI ; Che JIAN-XIANG ; Chen LEI ; Song TING-TING ; Qu JIN-TAO
Chinese Medical Sciences Journal 2024;39(1):54-68,中插6
Objective Dexmedetomidine(Dex)is a highly selective α2 adrenoceptor agonist that reduces blood pressure and heart rate.However,its ability to provide stable hemodynamics and a clinically significant reduction in blood loss in spine surgery is still a matter of debate.This study aimed to investigate the effects of Dex on intraoperative hemodynamics and blood loss in patients undergoing spine surgery. Methods The Web of Science,MEDLINE,EMBASE,and the Cochrane Library were searched up to February 2023 for randomized controlled trials(RCTs)including patients undergoing spine surgeries under general anaesthesia and comparing Dex and saline.A fixed-or random-effect model was used depending on heterogeneity. Results Twenty-one RCTs,including 1388 patients,were identified.Dex added the overall risk of intraoperative hypotension(odds ratio[OR]:2.11;95%confidence interval[CI]:1.24-3.58;P=0.006)and bradycardia(OR:2.48;95%CI:1.57-3.93;P=0.0001).The use of a loading dose of Dex led to significantly increased risks of intraoperative hypotension(OR:2.00;95%CI:1.06-3.79;P=0.03)and bradycardia(OR:2.28;95%CI:1.42-3.66;P=0.0007).For patients receiving total intravenous anesthesia,there was an increased risk of hypotension(OR:2.90;95%CI:1.24-6.82;P=0.01)and bradycardia(OR:2.66;95%CI:1.53-4.61;P=0.0005).For patients in the inhalation anesthesia group,only an increased risk of bradycardia(OR:4.95;95%CI:1.41-17.37;P=0.01)was observed.No significant increase in the risk of hypotension and bradycardia was found in the combined intravenous-inhalation anesthesia group.The incidence of severe hypotension(OR:2.57;95%CI:1.05-6.32;P=0.04),but not mild hypotension,was increased.Both mild(OR:2.55;95%CI:1.06-6.15;P=0.04)and severe(OR:2.45;95%CI:1.43-4.20;P=0.001)bradycardia were associated with a higher risk.The overall analyses did not reveal significant reduction in intraoperative blood loss.However,a significant decrease in blood loss was observed in total inhalation anesthesia subgroup(mean difference[MD]:-82.97;95%CI:-109.04--56.90;P<0.001). Conclusions Dex increases the risks of intraoperative hypotension and bradycardia in major spine surgery.The administration of a loading dose of Dex and the utilization of various anesthesia maintenance methods may potentially impact hemodynamic stability and intraoperative blood loss.
7.Prediction method of diopter based on sequence of ocular biological parameters
Luebiao XU ; Lan DING ; Chen LIANG ; Yuliang WANG ; Yujia LIU ; Jianmin SHANG ; Jun ZHU ; Huazhong XIANG ; Renyuan CHU ; Cheng WANG ; Xiaomei QU
International Journal of Biomedical Engineering 2024;47(5):417-422
Objective:To establish a prediction method of diopter based on sequence of ocular biological parameters.Methods:A stratified random cluster sampling method was used to extract the dataset. The dataset consisted of data collected from January 2022 to January 2023 by the Eye & ENT Hospital, Fudan University, from children aged 5 to 13 years in 2 key schools and 2 general schools of Yangpu District, Shanghai. Children’s ocular biological parameters, including sex, age, diopter, axial length, corneal curvature, and anterior chamber depth were collected. The slope of the optimally fitted straight line was calculated using the least squares method. The least square-back propagation (BP) neural network model was established by combining baseline data and the pre-processed rate of the change of ocular biological parameters. The dataset was divided into the training set and the validation set according to the ratio of 8:2 for five-fold cross-validation. The model performance was evaluated by using the mean absolute error (MAE), mean squared error (MSE), root mean square error (RMSE), correlation coefficient R, and coefficient of determination R2. Results:The optimal performances of R2, R, RMSE, MAE, and MSE of the least square-BP neural network model were 0.96, 0.981 9, 0.214 2, 0.139 9 D, 0.045 9, respectively. The regression equation between the predicted value and the true value of the diopter was y=0.97 x+ 0.014 8, R2=0.97, with good correlation. In the internal verification, MAE values of the diopter at three, six, nine, and twelve months of follow-up were 0.110 1, 0.136 0, 0.153 7, and 0.184 8 D, respectively, which achieved clinically acceptable performance (less than 0.25 D). In the external validation, the errors were less than 0.25 D at all ages. Conclusions:A prediction method of diopter based on sequence of ocular biological parameters was successfully developed.
8.Comparative study on surface roughness of polishing cercon zirconia with four polishing tools
Yuxi HAN ; Weijun ZHANG ; Jing XU ; Mengting YAO ; Zhe QU ; Xiang ZHANG
STOMATOLOGY 2024;44(10):759-764
Objective To evaluate the polishing finish of four different polishing tools.Methods Fifty specimens were selected from suitable zirconia and randomly divided into 5 groups with 10 specimens in each group.Group A was the negative control group;Group B was the EVE group;Group C was the SHOFU group;Group D was the Toboom group,and Group E was the NAIS group.All specimens were subjected to surface roughness measurements after each level of treatment.One specimen in each group was randomly selected after each level of treatment and put into the vacuum coater for surface gold spraying,and then put into the scanning electron microscope for surface morphology observation after vacuuming.Results Final Ra value:The negative group((1.677±0.066)μm)>SHOFU group((0.357±0.037)μm)>EVE group((0.248±0.051)μm)>Toboom group((0.115±0.039)μm)and NAIS group((0.123±0.029)μm).Scanning electron microscope observation showed that the deepest and longest scratches were left on the surface of the specimen with the diamond needle,and the surface of the specimen was gradually smoothed by using the polishing kit to treat the surfacein turn.The surface of the specimens polished by NAIS group and Toboom group had the least and shallow scratches under the mirror.Conclu-sion Toboom and NAIS zirconia polishing tools provide the best polishing results.
9.Laboratory proficiency testing for creepage distance and electrical clearance test of medical electrical equipment based on GB 9706.1-2020
Xiao-Ming GAO ; Song-Yan XU ; Xiao-Peng HAN ; Zhen-Shi LIANG ; Man ZHANG ; Ting-Ru GUAN ; Hui-Ru WANG ; Yuan-Yuan QU ; Xin-Hua XIANG
Chinese Medical Equipment Journal 2024;45(10):54-59
Objective To clarify the understanding of types of laboratories and manufacturers for GB 9706.1-2020 Medical electrical equipment-Part 1:General requirements for basic safety and essential performance by laboratory proficiency testing for creepage distance and electrical clearance test.Methods An operation guide was formed according to the testing program in GB 9706.1-2020,and the homogeneity and stability of the samples were evaluated according to CNAS-GL003:2018 Guidance on Evaluating the Homogenneity and Stability of Samples Used for Proficiency Testing.Robust statistic methods were used to assess the quantitative parameters of the test results of the participating laboratories according to the requirements in GB/T 28043-2019 Statistical methods for use in proficiency testing by interlaboratory comparison;the results reported by the expert laboratories were used as the specified values of the qualitative parameters.SPSS 25.0 statistical software was used for data analysis.Results All the results of the crreepage distance and electrical clearance tests met the requirements for homogeneity and stability.Of the 46 laboratories involved in,37 ones did have comprehensive satisfactory determinations while the remained 9 ones not.Conclusion Some laboratories don't behave well in understanding the standard,which have to be reformed accordingly to enhance their proficiencies.[Chinese Medical Equipment Journal,2024,45(10):54-59]
10.A retrospective study of occlusal reconstruction in patients with old jaw fractures and dentition defects
Ming-Chao DING ; Bo-Ya JING ; Jin SHI ; Liu YANG ; Xiang-Dong LIU ; Jing-Fu WANG ; Shuang QU ; Jia-Wu LIANG ; Zi-Hao TANG ; Jin-Long ZHAO ; Lei TIAN
Chinese Journal of Traumatology 2024;27(5):272-278
Purpose::This study evaluated the methods and clinical effects of multidisciplinary collaborative treatment for occlusal reconstruction in patients with old jaw fractures and dentition defects.Methods::Patients with old jaw fractures and dentition defects who underwent occlusal reconstruction at the Third Affiliated Hospital of Air Force Military Medical University from January 2018 to December 2022 were enrolled. Clinical treatment was classified into 3 phases. In phase I, techniques such as orthognathic surgery, microsurgery, and distraction osteogenesis were employed to reconstruct the correct 3-dimensional (3D) jaw position relationship. In phase II, bone augmentation and soft tissue management techniques were utilized to address insufficient alveolar bone mass and poor gingival soft tissue conditions. In phase III, implant-supported overdentures or fixed dentures were used for occlusal reconstruction. A summary of treatment methods, clinical efficacy evaluation, comparative analysis of imageological examinations, and satisfaction questionnaire survey were utilized to evaluate the therapeutic efficacy in patients with traumatic old jaw fractures and dentition defects. All data are summarized using the arithmetic mean ± standard deviation and compared using independent sample t-tests. Results::In 15 patients with old jaw fractures and dentition defects (an average age of 32 years, ranging from 18 to 53 years), there were 7 cases of malocclusion of single maxillary fracture, 6 of malocclusion of single mandible fracture, and 2 of malocclusion of both maxillary and mandible fractures. There were 5 patients with single maxillary dentition defects, 2 with single mandibular dentition defects, and 8 with both maxillary and mandibular dentition defects. To reconstruct the correct 3D jaw positional relationship, 5 patients underwent Le Fort I osteotomy of the maxilla, 3 underwent bilateral sagittal split ramus osteotomy of the mandible, 4 underwent open reduction and internal fixation for old jaw fractures, 3 underwent temporomandibular joint surgery, and 4 underwent distraction osteogenesis. All patients underwent jawbone augmentation, of whom 4 patients underwent a free composite vascularized bone flap (26.66%) and the remaining patients underwent local alveolar bone augmentation. Free gingival graft and connective tissue graft were the main methods for soft tissue augmentation (73.33%). The 15 patients received 81 implants, of whom 11 patients received implant-supported fixed dentures and 4 received implant-supported removable dentures. The survival rate of all implants was 93.82%. The final imageological examination of 15 patients confirmed that the malocclusion was corrected, and the clinical treatment ultimately achieved occlusal function reconstruction. The patient satisfaction questionnaire survey showed that they were satisfied with the efficacy, phonetics, aesthetics, and comfort after treatment.Conclusion::Occlusal reconstruction of old jaw fractures and dentition defects requires a phased sequential comprehensive treatment, consisting of 3D spatial jaw correction, alveolar bone augmentation and soft tissue augmentation, and implant-supported occlusal reconstruction, achieving satisfactory clinical therapeutic efficacy.


Result Analysis
Print
Save
E-mail