1.Interpretation of perioperative immunotherapy for lung cancer in 2024 WCLC/ESMO
Jiahe LI ; Xiaopeng REN ; Jiayu LU ; Chenyuan ZHANG ; Ruitao FAN ; Xuxu ZHANG ; Xinyao XU ; Guizhen LI ; Jipeng ZHANG ; Wei LI ; Qiang LU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):300-307
		                        		
		                        			
		                        			The 2024 World Conference on Lung Cancer (WCLC) and the European Society for Medical Oncology (ESMO) Annual Meeting, two of the most prestigious events in oncology, have concluded sequentially. As the most authoritative annual gatherings in lung cancer and the entire oncology field, the WCLC and ESMO conferences brought together top oncology experts and scientists from around the world to share, discuss, and publish the latest cutting-edge advancements in oncology. In both conferences, lung cancer immunotherapy remained a hot topic of considerable interest. This article aims to summarize and discuss the important research progress on perioperative immunotherapy for non-small cell lung cancer reported at the two conferences.
		                        		
		                        		
		                        		
		                        	
2.The Impairment Attention Capture by Topological Change in Children With Autism Spectrum Disorder
Hui-Lin XU ; Huan-Jun XI ; Tao DUAN ; Jing LI ; Dan-Dan LI ; Kai WANG ; Chun-Yan ZHU
Progress in Biochemistry and Biophysics 2025;52(1):223-232
		                        		
		                        			
		                        			ObjectiveAutism spectrum disorder (ASD) is a neurodevelopmental condition characterized by difficulties with communication and social interaction, restricted and repetitive behaviors. Previous studies have indicated that individuals with ASD exhibit early and lifelong attention deficits, which are closely related to the core symptoms of ASD. Basic visual attention processes may provide a critical foundation for their social communication and interaction abilities. Therefore, this study explores the behavior of children with ASD in capturing attention to changes in topological properties. MethodsOur study recruited twenty-seven ASD children diagnosed by professional clinicians according to DSM-5 and twenty-eight typically developing (TD) age-matched controls. In an attention capture task, we recorded the saccadic behaviors of children with ASD and TD in response to topological change (TC) and non-topological change (nTC) stimuli. Saccadic reaction time (SRT), visual search time (VS), and first fixation dwell time (FFDT) were used as indicators of attentional bias. Pearson correlation tests between the clinical assessment scales and attentional bias were conducted. ResultsThis study found that TD children had significantly faster SRT (P<0.05) and VS (P<0.05) for the TC stimuli compared to the nTC stimuli, while the children with ASD did not exhibit significant differences in either measure (P>0.05). Additionally, ASD children demonstrated significantly less attention towards the TC targets (measured by FFDT), in comparison to TD children (P<0.05). Furthermore, ASD children exhibited a significant negative linear correlation between their attentional bias (measured by VS) and their scores on the compulsive subscale (P<0.05). ConclusionThe results suggest that children with ASD have difficulty shifting their attention to objects with topological changes during change detection. This atypical attention may affect the child’s cognitive and behavioral development, thereby impacting their social communication and interaction. In sum, our findings indicate that difficulties in attentional capture by TC may be a key feature of ASD. 
		                        		
		                        		
		                        		
		                        	
3.Development and validation of a prognostic nomogram model for patients with the lower third and abdominal oesophageal adenocarcinoma
Zhengshui XU ; Dandan LIU ; Jiantao JIANG ; Ranran KONG ; Jianzhong LI ; Yuefeng MA ; Zhenchuan MA ; Jia CHEN ; Minxia ZHU ; Shaomin LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):201-207
		                        		
		                        			
		                        			Objective To establish an individualized nomogram model and evaluate its efficacy to provide a possible evaluation basis for the prognosis of lower third and abdominal part of oesophageal adenocarcinoma (EAC). Methods Lower third and abdominal part of EAC patients from 2010 to 2015 were chosen from the SEER Research Plus Database (17 Regs, 2022nov sub). The patients were randomly allocated to the training cohort and the internal validation cohort with a ratio of 7∶3 using bootstrap resampling. The Cox proportional hazards regression analysis was used to determine significant contributors to overall survival (OS) in EAC patients, which would be elected to construct the nomogram prediction model. C-index, calibration curve and receiver operating characteristic (ROC) curve were performed to evaluate its efficacy. Finally, the efficacy to evaluate the OS of EAC patients was compared between the nomogram prediction model and TNM staging system. Results In total, 3945 patients with lower third and abdominal part of EAC were enrolled, including 3475 males and 470 females with a median age of 65 (57-72) years. The 2761 patients were allocated to the training cohort and the remaining 1184 patients to the internal validation cohort. In the training and the internal validation cohorts, the C-index of the nomogram model was 0.705 and 0.713, respectively. Meanwhile, the calibration curve also suggested that the nomogram model had a strong capability of predicting 1-, 3-, and 5-year OS rates of EAC patients. The nomogram also had a higher efficacy than the TNM staging system in predicting 1-, 3-, and 5-year OS rates of EAC patients. Conclusion This nomogram prediction model has a high efficiency for predicting OS in the patients with lower third and abdominal part of EAC, which is higher than that of the current TNM staging system.
		                        		
		                        		
		                        		
		                        	
4.Effect of NEP1-40/PLGA on facial nerve repair in rats
XUE Bing ; XI Hualei ; YAO Lihong ; XU Wanqiu ; XU Xiaohang ; LIN Song ; PIAO Guiyan ; WANG Xiumei
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(2):110-119
		                        		
		                        			Objective:
		                        			 To investigate the effect of neurite outgrowth inhibitor extracellular peptide residues 1-40 (NEP1-40) combined with poly (lactic-co-glycolic acid) (PLGA) and gelatin electrospun fiber membrane on facial nerve repair in rats. 
		                        		
		                        			Methods:
		                        			According to the principle of random grouping, 108 male SD rats were divided into four groups (n = 27 in each group, approved by the ethics committee), namely, the sham group, control group, PLGA group, and NEP1-40 + PLGA group. A facial nerve fracture model was established for all of the groups except for the sham group. The control group received no further treatment, the PLGA group and the NEP1-40+PLGA group were supported by PLGA membrane, and the NEP1-40+PLGA group received one immediate local injection of NEP1-40 (5 μg/μL) at a dose of 10 μL. Facial nerve function analysis, electrophysiological examination, transmission electron microscope observation, HE staining, and immunohistochemical staining of myelin marker S100β and axonal marker β3-tubulin were used to evaluate the recovery of injured facial nerves of rats at 2, 4 and 8 weeks.
		                        		
		                        			Results :
		                        			 At 8 weeks, the facial nerve function score of the NEP1-40+PLGA group was better than that of the control group and PLGA group (P < 0.001), and facial nerve function was significantly restored. Electrophysiological examination of nerve action potentials at the injured facial nerve showed that the amplitude in the NEP1-40+PLGA group was higher than that of the control group and PLGA group (P < 0.001), but there was no significant difference in latency and conduction velocity results between the groups (P > 0.05). At 2, 4, and 8 weeks, transmission electron microscopy showed that the number of myelinated nerve fibers and myelin sheath thickness in the cross-section of the injured facial nerve in the NEP1-40+PLGA group were greater than those in the other groups (P < 0.05). At 8 weeks, HE staining showed that the facial nerves in the control group had partially recovered, but the overall cell distribution was uneven and the boundary with surrounding tissues was slightly blurred. In contrast, the NEP1-40+PLGA group had a relatively uniform cell distribution and a clearer boundary with surrounding tissues. At 2, 4, and 8 weeks, the immunohistochemical results showed that in the cross-section of the injuried facial nerve, NEP1-40 increased the expression of neural markers S100 β and β3-tubulin, especially β3-tubulin, which was close to normal levels (P > 0.05)
		                        		
		                        			Conclusion
		                        			NEP1-40 is beneficial for the generation of new myelin sheaths and axons at the site of injury, and it can promote the repair and regeneration of injured facial nerves to a certain extent, thus accelerating the recovery of injured nerve function.
		                        		
		                        		
		                        		
		                        	
5.Environmental contamination status of norovirus outbreaks in schools and nurseries in Linhai City
ZHENG Jianjun, WANG Xi,HONG Danyang, LI Yaling, XU Qiumeng, ZHANG Huili, HAN Qian, LU Da, ZHENG Qiao
Chinese Journal of School Health 2025;46(4):601-603
		                        		
		                        			Objective:
		                        			To investigate the environmental contamination of norovirus in nurseries and primary/secondary schools, so as to provide a scientific basis for effective prevention and control measures.
		                        		
		                        			Methods:
		                        			A total of 483 external environmental samples were collected from 34 cluster outbreaks of norovirus gastroenteritis in kindergartens and primary/secondary schools in Linhai City from 2021 to 2024. Pathogen detection was conducted using a rapid nucleic acid extraction kit and realtime fluorescence RT-PCR, and the results were analyzed using the χ2 test or Fishers exact test.
		                        		
		                        			Results:
		                        			Among the collected external environmental samples, the total positive rate of surface contamination was 13.66%. The positive rates in kindergartens and primary/secondary schools were 12.20% and 15.82%, respectively. In kindergartens, the five surfaces with the highest detection rates were desks/chairs (23.33%), toilet stool troughs (20.69%), urinal troughs (12.00%), washbasins/sinks (11.11%), and toilet mops (9.38%). In primary/secondary schools, the top five were toilet stool troughs (38.30%), urinal troughs (23.53%), toilet door handles (13.04%), toilet mops (12.50%), and drinking cups (11.11%). The difference in positive detection rates among different external environments in primary/secondary schools was statistically significant (Fishers exact probability test, P<0.01). The positive detection rate in sanitary toilets was higher than that in classroom environments (χ2=17.38), while the positive detection rate in classroom environments of kindergartens was higher than that in primary/secondary schools (χ2=5.42)(P<0.05).
		                        		
		                        			Conclusions
		                        			Norovirus exhibits a high contamination rate in nurseries and schools, particularly in restroom areas. Strengthening sanitation and disinfection in highrisk environments, and improving hygiene awareness among children and staff, are essential for the effective prevent and control of norovirus.
		                        		
		                        		
		                        		
		                        	
6.Preliminary exploration of differentiating and treating multiple system atrophy from the perspective of the eight extraordinary meridians
Di ZHAO ; Zhigang CHEN ; Nannan LI ; Lu CHEN ; Yao WANG ; Jing XUE ; Xinning ZHANG ; Chengru JIA ; Xuan XU ; Kaige ZHANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(3):392-397
		                        		
		                        			
		                        			Multiple system atrophy (MSA) is a rare neurodegenerative disease with complex clinical manifestations, presenting substantial challenges in clinical diagnosis and treatment. Its symptoms and the eight extraordinary meridians are potentially correlated; therefore, this article explores the association between MSA symptom clusters and the eight extraordinary meridians based on their circulation and physiological functions, as well as their treatment strategies. The progression from deficiency to damage in the eight extraordinary meridians aligns with the core pathogenesis of MSA, which is characterized by "the continuous accumulation of impacts from the vital qi deficiency leading to eventual damage". Liver and kidney deficiency and the emptiness of the eight extraordinary meridians are required for the onset of MSA; the stagnation of qi deficiency and the gradual damage to the eight extraordinary meridians are the key stages in the prolonged progression of MSA. The disease often begins with the involvement of the yin and yang qiao mai, governor vessel, thoroughfare vessel, and conception vessel before progressing to multiple meridian involvements, ultimately affecting all eight extraordinary meridians simultaneously. The treatment approach emphasizes that "the direct method may be used for joining battle, but indirect method will be needed in order to secure victory" and focuses on "eliminate pathogenic factors and reinforce healthy qi". Distinguishing the extraordinary meridians and focusing on the primary symptoms are pivotal to improving efficacy. Clinical treatment is aimed at the target, and tailored treatment based on careful clinical observation ensures precision in targeting the disease using the eight extraordinary meridians as the framework and core symptoms as the specific focus. Additionally, combining acupuncture, daoyin therapy, and other method may help prolong survival. This article classifies clinical manifestations based on the theory of the eight extraordinary meridians and explores treatment.
		                        		
		                        		
		                        		
		                        	
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
            