1.Performance of body mass index, waist circumference and waist-to-height ratio in screening true obesity in children
FANG Qihuan, WANG Yuedong, ZHAO Min, YANG Lili, XI Bo
Chinese Journal of School Health 2025;46(3):421-425
Objective:
To evaluate the accuracy of body mass index (BMI), waist circumference (WC) and waist-to-height ratio (WHtR) in screening true obesity among children, so as to provide a scientific basis for precise screening and early prevention and control of childhood obesity.
Methods:
A total of 1 322 children aged 10-15 years old were surveyed by the Huantai Children Cardiovascular Health Cohort in 2021. Fat mass percentage (FMP) and fat mass index (FMI) were measured by bioelectrical impedance analysis, with FMP or FMI values at or above the age and sex-specific 70th percentiles as the criteria for defining true obesity. BMI, WC and WHtR were used to define general obesity and central obesity. The accuracy of these measures in screening for true obesity was evaluated by calculating the missed diagnosis rate, misdiagnosis rate, area under the curve(AUC) for receiver operating characteristic and Kappa coefficient.
Results:
Boys had higher BMI [(21.79±4.56) kg/m 2], WC [(76.41±12.53) cm] and WHtR (0.47±0.07) than girls [(20.83±4.13) kg/m 2, (70.69±10.06) cm, (0.45±0.06)] ( t =4.02, 9.19, 6.63), while boys had lower FMP [(18.29±8.35)%] and FMI [(4.35±2.79) kg/m 2] than girls [(24.87±6.51)%, (5.44±2.53) kg/m 2] ( t =-16.10,-7.42) ( P <0.01). Using FMP as a reference standard, the diagnosis error rates of screening for true obesity based on BMI, WC and WHtR were 12.24%, 2.11% and 2.11%, respectively; the diagnosis error rates were 10.88%, 27.28% and 24.33%; the AUC values were 0.88, 0.85 and 0.87; the Kappa coefficients were 0.67, 0.48 and 0.52. Using FMI as a reference standard, rates of BMI, WC and WHtR screening for true obesity were 14.20%, 1.23% and 2.78%; the diagnosis error rates were 4.81%, 20.84% and 18.14 %; the AUC values were 0.90, 0.89 and 0.90; the Kappa coefficients were 0.81, 0.64 and 0.67.
Conclusions
BMI has a higher diagnosis error rate in screening for true obesity in children, while WC and WHtR have higher diagnosis error rates. It is recommended to promote body fat assessment in clinical practice, so as to achieve more accurate prevention and control of chronic diseases.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Associations between weekday-weekend screen time and subjective sleep quality among adolescents
CAO Runze, ZHAO Min, WANG Mingming, XI Bo
Chinese Journal of School Health 2025;46(8):1170-1174
Objective:
To explore the association between the joint association of screen time on weekdays and weekends with self rated sleep quality among adolescents, providing scientific basis for improving adolescent sleep health.
Methods:
Using data from "Huantai Children s Cardiovascular Health Follow up Cohort" survey conducted during November to December 2023, a total of 1 197 adolescents aged 12-17 years with complete demographic characteristics, physical measurements, and questionnaire data were included. The dose response relationship between screen time and sleep quality was evaluated by restrictive cubic splines (RCS). Based on screen time on weekdays and weekends (normal: < 2 h/d; excessive: ≥ 2 h/d), adolescents were categorized into 4 groups. Multivariate Logistic regression models were used to analyze the association between the combined effect of screen time on weekdays and weekends and sleep quality.
Results:
The RCS analysis results showed that there was a linear dose response relationship between average daily screen time and poor sleep quality in adolescents (non linear P >0.05). The results of multiple Logistic regression analysis showed that adjusting for potential covariates,compared with adolescents having normal screen time on both weekdays and weekends, those with excessive screen time on both weekdays and weekends had increased risk of poor sleep quality ( OR=2.51, 95%CI=1.33-4.62, P <0.01). Sex stratified analysis revealed that girls with excessive screen time on both weekdays and weekends had increased odds of poor sleep quality ( OR=3.03, 95%CI=1.23-7.14, P =0.01), compared to girls who had normal screen time on both weekdays and weekends.
Conclusions
A linear dose response relationship exists between daily screen time and poor sleep quality in adolescents. Excessive screen time on both weekdays and weekends is positively associated with poor sleep quality, particularly more pronounced among female adolescents.
8.Consensus statement on research and application of Chinese herbal medicine derived extracellular vesicles-like particles (2023 edition).
Qing ZHAO ; Tong WANG ; Hongbin WANG ; Peng CAO ; Chengyu JIANG ; Hongzhi QIAO ; Lihua PENG ; Xingdong LIN ; Yunyao JIANG ; Honglei JIN ; Huantian ZHANG ; Shengpeng WANG ; Yang WANG ; Ying WANG ; Xi CHEN ; Junbing FAN ; Bo LI ; Geng LI ; Bifeng LIU ; Zhiyang LI ; Suhua QI ; Mingzhen ZHANG ; Jianjian ZHENG ; Jiuyao ZHOU ; Lei ZHENG ; Kewei ZHAO
Chinese Herbal Medicines 2024;16(1):3-12
To promote the development of extracellular vesicles of herbal medicine especially the establishment of standardization, led by the National Expert Committee on Research and Application of Chinese Herbal Vesicles, research experts in the field of herbal medicine and extracellular vesicles were invited nationwide with the support of the Expert Committee on Research and Application of Chinese Herbal Vesicles, Professional Committee on Extracellular Vesicle Research and Application, Chinese Society of Research Hospitals and the Guangdong Engineering Research Center of Chinese Herbal Vesicles. Based on the collation of relevant literature, we have adopted the Delphi method, the consensus meeting method combined with the nominal group method to form a discussion draft of "Consensus statement on research and application of Chinese herbal medicine derived extracellular vesicles-like particles (2023)". The first draft was discussed in online and offline meetings on October 12, 14, November 2, 2022 and April and May 2023 on the current status of research, nomenclature, isolation methods, quality standards and research applications of extracellular vesicles of Chinese herbal medicines, and 13 consensus opinions were finally formed. At the Third Academic Conference on Research and Application of Chinese Herbal Vesicles, held on May 26, 2023, Kewei Zhao, convenor of the consensus, presented and read the consensus to the experts of the Expert Committee on Research and Application of Chinese Herbal Vesicles. The consensus highlights the characteristics and advantages of Chinese medicine, inherits the essence, and keeps the righteousness and innovation, aiming to provide a reference for colleagues engaged in research and application of Chinese herbal vesicles at home and abroad, decode the mystery behind Chinese herbal vesicles together, establish a safe, effective and controllable accurate Chinese herbal vesicle prevention and treatment system, and build a bridge for Chinese medicine to the world.
9.Method development and validation for testing the concentration of anti-TNF-α monoclonal antibody in serum based on ELISA
Zhen-Xiang HU ; Li-Xiu HE ; Bo WANG ; Xi CHEN ; Gui-Li LIU ; Yu-Min QIN
The Chinese Journal of Clinical Pharmacology 2024;40(11):1642-1645
Objective To establish an indirect enzyme-linked immunosorbent assay(ELISA)method for testing the concentration of a monoclonal antibody target tumor necrosis factor-α(TNF-α)in animal serum.Methods The critical parameters of the method including coating concentration of human TNF-α,source,concentration and stability of HRP-labeled goat anti-human immunoglobulin G(IgG)were investigated.The specificity,accuracy,precision,linearity and Limited of Determination of the method were investigated.Results The critical parameters of the method were confirmed as below:TNF-α was coated at 400 ng·mL-1;HRP labeled goat anti-human IgG antibody was diluted at 1:3.0 ×105;the diluted horseradish peroxidase labeled goat anti-human IgG antibody is well stored at 4 ℃ for 3 days.Meanwhile the method was confirmed to have good specificity,the recovery rate ranged from 84.00%to 106.82%,the coefficient of variation of different antibody concentration levels were no more than 10%;the method had a good linearity and the standard curve was y=(-8.37×103-2.37 × 106)/[1+(x/29.80)106]+2.37 × 106(R2=0.999);the limit of quantification was 1 ng·mL-1,all of which met the requirements.Conclusion A accurate and robust ELISA method was developed to test the concentration of anti-TNF-α monoclonal antibody in serum.
10.TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children
Xi MING ; Liqun WU ; Ziwei WANG ; Bo WANG ; Jialin ZHENG ; Jingwei HUO ; Mei HAN ; Xiaochun FENG ; Baoqing ZHANG ; Xia ZHAO ; Mengqing WANG ; Zheng XUE ; Ke CHANG ; Youpeng WANG ; Yanhong QIN ; Bin YUAN ; Hua CHEN ; Lining WANG ; Xianqing REN ; Hua XU ; Liping SUN ; Zhenqi WU ; Yun ZHAO ; Xinmin LI ; Min LI ; Jian CHEN ; Junhong WANG ; Yonghong JIANG ; Yongbin YAN ; Hengmiao GAO ; Hongmin FU ; Yongkun HUANG ; Jinghui YANG ; Zhu CHEN ; Lei XIONG
Journal of Nanjing University of Traditional Chinese Medicine 2024;40(7):722-732
Following the principles of evidence-based medicine,in accordance with the structure and drafting rules of standardized documents,based on literature research,according to the characteristics of chronic cough in children and issues that need to form a consensus,the TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children was formulated based on the Delphi method,expert discussion meetings,and public solicitation of opinions.The guideline includes scope of application,terms and definitions,eti-ology and diagnosis,auxiliary examination,treatment,prevention and care.The aim is to clarify the optimal treatment plan of Chinese medicine in the diagnosis and treatment of this disease,and to provide guidance for improving the clinical diagnosis and treatment of chronic cough in children with Chinese medicine.


Result Analysis
Print
Save
E-mail