1.Xenon post-conditioning protects against spinal cord ischemia-reperfusion injury in rats by downregulating mTOR pathway and inhibiting endoplasmic reticulum stress-induced neuronal apoptosis.
Lan LUO ; Jia Qi TONG ; Lu LI ; Mu JIN
Journal of Southern Medical University 2022;42(8):1256-1262
OBJECTIVE:
The purpose of this study was to determine whether xenon post-conditioning affects mTOR signaling as well as endoplasmic reticulum stress (ERS)-apoptosis pathway in rats with spinal cord ischemia/reperfusion injury.
METHODS:
Fifty male rats were randomized equally into sham-operated group (Sham group), I/R model group (I/R group), I/R model+ xenon post-conditioning group (Xe group), I/R model+rapamycin (a mTOR signaling pathway inhibitor) treatment group (I/R+ Rapa group), and I/R model + xenon post- conditioning with rapamycin treatment group (Xe + Rapa group).. In the latter 4 groups, SCIRI was induced by clamping the abdominal aorta for 85 min followed by reperfusion for 4 h. Rapamycin (or vehicle) was administered by daily intraperitoneal injection (4 mg/kg) for 3 days before SCIRI, and xenon post-conditioning by inhalation of 1∶1 mixture of xenon and oxygen for 1 h at 1 h after initiation of reperfusion; the rats without xenon post-conditioning were given inhalation of nitrogen and oxygen (1∶ 1). After the reperfusion, motor function and histopathologic changes in the rats were examined. Western blotting and real-time PCR were used to detect the protein and mRNA expressions of GRP78, ATF6, IRE1α, PERK, mTOR, p-mTOR, Bax, Bcl-2 and caspase-3 in the spinal cord.
RESULTS:
The rats showed significantly lowered hind limb motor function following SCIRI (P < 0.01) with a decreased count of normal neurons, increased mRNA and protein expressions of GRP78, ATF6, IRE1α, PERK, and caspase-3, and elevated p-mTOR/mTOR ratio and Bax/Bcl-2 ratio (P < 0.01). Xenon post-conditioning significantly decreased the mRNA and protein levels of GRP78, ATF6, IRE1α, PERK and caspase-3 (P < 0.05 or 0.01) and reduced p-mTOR/mTOR and Bax/Bcl-2 ratios (P < 0.01) in rats with SCIRI; the mRNA contents and protein levels of GRP78 and ATF6 were significantly decreased in I/R+Rapa group (P < 0.01). Compared with those in Xe group, the rats in I/R+Rapa group and Xe+Rapa had significantly lowered BBB and Tarlov scores of the hind legs (P < 0.01), and caspase-3 protein level and Bax/Bcl-2 ratio were significantly lowered in Xe+Rapa group (P < 0.05 or 0.01).
CONCLUSION
By inhibiting ERS and neuronal apoptosis, xenon post- conditioning may have protective effects against SCIRI in rats. The mTOR signaling pathway is partially involved in this process.
Animals
;
Apoptosis
;
Caspase 3/metabolism*
;
Endoplasmic Reticulum Stress
;
Endoribonucleases/pharmacology*
;
Injections, Intraperitoneal
;
Male
;
Neurons/pathology*
;
Nitrogen/metabolism*
;
Oxygen/metabolism*
;
Protein Serine-Threonine Kinases
;
Proto-Oncogene Proteins c-bcl-2/metabolism*
;
RNA, Messenger/metabolism*
;
Random Allocation
;
Rats
;
Rats, Sprague-Dawley
;
Reperfusion Injury/metabolism*
;
Sirolimus/pharmacology*
;
Spinal Cord Ischemia/pathology*
;
TOR Serine-Threonine Kinases/metabolism*
;
Xenon/therapeutic use*
;
bcl-2-Associated X Protein/metabolism*
2.Dual-Energy CT: New Horizon in Medical Imaging.
Korean Journal of Radiology 2017;18(4):555-569
Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.
Diagnostic Imaging*
;
Filtration
;
Humans
;
Iodine
;
Lung
;
Radiation Exposure
;
Uric Acid
;
Xenon
3.Hazards Caused by UV Rays of Xenon Light Based High Performance Solar Simulators.
Safety and Health at Work 2017;8(3):237-245
BACKGROUND: Solar furnaces are used worldwide to conduct experiments to demonstrate the feasibility of solar–chemical processes with the aid of concentrated sunlight, or to qualify high temperature-resistant components. In recent years, high-flux solar simulators (HFSSs) based on short-arc xenon lamps are more frequently used. The emitted spectrum is very similar to natural sunlight but with dangerous portions of ultraviolet light as well. Due to special benefits of solar simulators the increase of construction activity for HFSS can be observed worldwide. Hence, it is quite important to protect employees against serious injuries caused by ultraviolet radiation (UVR) in a range of 100 nm to 400 nm. METHODS: The UV measurements were made at the German Aerospace Center (DLR), Cologne and Paul-Scherrer-Institute (PSI), Switzerland, during normal operations of the HFSS, with a high-precision UV-A/B radiometer using different experiment setups at different power levels. Thus, the measurement results represent UV emissions which are typical when operating a HFSS. Therefore, the biological effects on people exposed to UVR was investigated systematically to identify the existing hazard potential. RESULTS: It should be noted that the permissible workplace exposure limits for UV emissions significantly exceeded after a few seconds. One critical value was strongly exceeded by a factor of 770. CONCLUSION: The prevention of emissions must first and foremost be carried out by structural measures. Furthermore, unambiguous protocols have to be defined and compliance must be monitored. For short-term activities in the hazard area, measures for the protection of eyes and skin must be taken.
Compliance
;
Skin
;
Sunlight
;
Switzerland
;
Ultraviolet Rays
;
Xenon*
4.Collateral Ventilation Quantification Using Xenon-Enhanced Dynamic Dual-Energy CT: Differences between Canine and Swine Models of Bronchial Occlusion.
Eun Ah PARK ; Jin Mo GOO ; Sang Joon PARK ; Chang Hyun LEE ; Chang Min PARK
Korean Journal of Radiology 2015;16(3):648-656
OBJECTIVE: The aim of this study was to evaluate whether the difference in the degree of collateral ventilation between canine and swine models of bronchial obstruction could be detected by using xenon-enhanced dynamic dual-energy CT. MATERIALS AND METHODS: Eight mongrel dogs and six pigs underwent dynamic dual-energy scanning of 64-slice dual-source CT at 12-second interval for 2-minute wash-in period (60% xenon) and at 24-second interval for 3-minute wash-out period with segmental bronchus occluded. Ventilation parameters of magnitude (A value), maximal slope, velocity (K value), and time-to-peak (TTP) enhancement were calculated from dynamic xenon maps using exponential function of Kety model. RESULTS: A larger difference in A value between parenchyma was observed in pigs than in dogs (absolute difference, -33.0 +/- 5.0 Hounsfield units [HU] vs. -2.8 +/- 7.1 HU, p = 0.001; normalized percentage difference, -79.8 +/- 1.8% vs. -5.4 +/- 16.4%, p = 0.0007). Mean maximal slopes in both periods in the occluded parenchyma only decreased in pigs (all p < 0.05). K values of both periods were not different (p = 0.892) in dogs. However, a significant (p = 0.027) difference was found in pigs in the wash-in period. TTP was delayed in the occluded parenchyma in pigs (p = 0.013) but not in dogs (p = 0.892). CONCLUSION: Xenon-ventilation CT allows the quantification of collateral ventilation and detection of differences between canine and swine models of bronchial obstruction.
Airway Obstruction/*radiography
;
Animals
;
Bronchial Diseases/*radiography
;
Bronchography/*methods
;
Disease Models, Animal
;
Dogs
;
Pulmonary Ventilation/*physiology
;
Respiration
;
Swine
;
Tomography, Spiral Computed/*methods
;
Xenon
5.Computer-Aided Classification of Visual Ventilation Patterns in Patients with Chronic Obstructive Pulmonary Disease at Two-Phase Xenon-Enhanced CT.
Soon Ho YOON ; Jin Mo GOO ; Julip JUNG ; Helen HONG ; Eun Ah PARK ; Chang Hyun LEE ; Youkyung LEE ; Kwang Nam JIN ; Ji Yung CHOO ; Nyoung Keun LEE
Korean Journal of Radiology 2014;15(3):386-396
OBJECTIVE: To evaluate the technical feasibility, performance, and interobserver agreement of a computer-aided classification (CAC) system for regional ventilation at two-phase xenon-enhanced CT in patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS: Thirty-eight patients with COPD underwent two-phase xenon ventilation CT with resulting wash-in (WI) and wash-out (WO) xenon images. The regional ventilation in structural abnormalities was visually categorized into four patterns by consensus of two experienced radiologists who compared the xenon attenuation of structural abnormalities with that of adjacent normal parenchyma in the WI and WO images, and it served as the reference. Two series of image datasets of structural abnormalities were randomly extracted for optimization and validation. The proportion of agreement on a per-lesion basis and receiver operating characteristics on a per-pixel basis between CAC and reference were analyzed for optimization. Thereafter, six readers independently categorized the regional ventilation in structural abnormalities in the validation set without and with a CAC map. Interobserver agreement was also compared between assessments without and with CAC maps using multirater kappa statistics. RESULTS: Computer-aided classification maps were successfully generated in 31 patients (81.5%). The proportion of agreement and the average area under the curve of optimized CAC maps were 94% (75/80) and 0.994, respectively. Multirater kappa value was improved from moderate (kappa = 0.59; 95% confidence interval [CI], 0.56-0.62) at the initial assessment to excellent (kappa = 0.82; 95% CI, 0.79-0.85) with the CAC map. CONCLUSION: Our proposed CAC system demonstrated the potential for regional ventilation pattern analysis and enhanced interobserver agreement on visual classification of regional ventilation.
Aged
;
Area Under Curve
;
Feasibility Studies
;
Female
;
Humans
;
Male
;
Middle Aged
;
Observer Variation
;
Pulmonary Disease, Chronic Obstructive/physiopathology/*radiography
;
Pulmonary Emphysema/physiopathology/radiography
;
*Respiration
;
Retrospective Studies
;
Tomography, X-Ray Computed/*methods
;
Xenon/*diagnostic use
6.Redistributed Regional Ventilation after the Administration of a Bronchodilator Demonstrated on Xenon-Inhaled Dual-Energy CT in a Patient with Asthma.
Korean Journal of Radiology 2011;12(3):386-389
We report here on the redistributed regional ventilation abnormalities after the administration of a bronchodilator and as seen on xenon-inhaled dual-energy CT in a patient with asthma. The improved ventilation seen in the right lower lobe and the decreased ventilation seen in the right middle lobe after the administration of a bronchodilator on xenon-inhaled dual-energy CT could explain a positive bronchodilator response on a pulmonary function test. These changes may reflect the heterogeneity of the airway responsiveness to a bronchodilator in patients with asthma.
Albuterol/*administration & dosage
;
Asthma/*physiopathology/*radiography
;
Bronchodilator Agents/*administration & dosage
;
Child
;
Female
;
Humans
;
Pulmonary Ventilation
;
Radiation Dosage
;
Tomography, X-Ray Computed/*methods
;
Xenon/diagnostic use
7.Collateral Ventilation to Congenital Hyperlucent Lung Lesions Assessed on Xenon-Enhanced Dynamic Dual-Energy CT: an Initial Experience.
Hyun Woo GOO ; Dong Hyun YANG ; Namkug KIM ; Seung Il PARK ; Dong Kwan KIM ; Ellen Ai KIM
Korean Journal of Radiology 2011;12(1):25-33
OBJECTIVE: We wanted to evaluate the resistance to collateral ventilation in congenital hyperlucent lung lesions and to correlate that with the anatomic findings on xenon-enhanced dynamic dual-energy CT. MATERIALS AND METHODS: Xenon-enhanced dynamic dual-energy CT was successfully and safely performed in eight children (median age: 5.5 years, 4 boys and 4 girls) with congenital hyperlucent lung lesions. Functional assessment of the lung lesions on the xenon map was done, including performing a time-xenon value curve analysis and assessing the amplitude of xenon enhancement (A) value, the rate of xenon enhancement (K) value and the time of arrival value. Based on the A value, the lung lesions were categorized into high or low (A value > 10 Hounsfield unit [HU]) resistance to collateral ventilation. In addition, the morphologic CT findings of the lung lesions, including cyst, mucocele and an accessory or incomplete fissure, were assessed on the weighted-average CT images. The xenon-enhanced CT radiation dose was estimated. RESULTS: Five of the eight lung lesions were categorized into the high resistance group and three lesions were categorized into the low resistance group. The A and K values in the normal lung were higher than those in the low resistance group. The time of arrival values were delayed in the low resistance group. Cysts were identified in five lesions, mucocele in four, accessory fissure in three and incomplete fissure in two. Either cyst or an accessory fissure was seen in four of the five lesions showing high resistance to collateral ventilation. The xenon-enhanced CT radiation dose was 2.3 +/- 0.6 mSv. CONCLUSION: Xenon-enhanced dynamic dual-energy CT can help visualize and quantitate various degrees of collateral ventilation to congenital hyperlucent lung lesions in addition to assessing the anatomic details of the lung.
Administration, Inhalation
;
Child
;
Child, Preschool
;
Female
;
Humans
;
Lung/abnormalities/*radiography
;
Lung, Hyperlucent/*congenital/physiopathology/*radiography
;
Male
;
*Pulmonary Ventilation
;
*Tomography, X-Ray Computed
;
Xenon/administration & dosage/*diagnostic use
8.Advances in research on neuroprotective effects of inert gas.
Sheng CHEN ; Song-xue GUO ; Yuan HONG ; Jian-min ZHANG
Journal of Zhejiang University. Medical sciences 2011;40(1):101-106
Inert gas is a group of rare gases with very low activity, their application in medical field has increasingly drawn attentions. It is known that inert gases helium, xenon and argon have protective effects on nervous system and the mechanisms are related to eradicating free radicals, anti-inflammation, suppressing apoptosis, influencing ion channels and so on. Further study on the neuroprotective effect of inert gas will shed light on a new approach to treat neurological diseases.
Argon
;
pharmacology
;
Helium
;
pharmacology
;
Neuroprotective Agents
;
pharmacology
;
Noble Gases
;
pharmacology
;
Xenon
;
pharmacology
10.A Comparative Study of the Efficacy and Safety of 530~750 nm and 555~950 nm Wavelength Bands of 2nd Generation IPL in Korean Photo-Rejuvenation.
Young Bok LEE ; Hyun Jeong PARK ; Jun Young LEE ; Baik Kee CHO
Korean Journal of Dermatology 2009;47(2):140-147
BACKGROUND: Recently, the 2nd generation IPL with a filtered xenon flash lamp has been widely used in the dermatologic field. In disagreement with the manufacturer's intent, for Asian skin, there were some reports that the best results for vascular lesions were obtained with the PR applicator, while the best results for pigmented lesions were obtained with the VL applicator. OBJECTIVE: The purpose of this study is to compare the efficacy and safety of two different (530~750 nm PR applicator and the 555~950 nm VL applicator) wavelength bands of 2nd generation IPL in Korean photo-rejuvenation. In addition, we compared the improvement of telangiectasia, irregular pigmentation, and overall patient' satisfaction for both settings. METHODS: Twenty-two patients with signs of photoaging skin including irregular pigmentation and telangiectasia were treated with 2nd generation IPL (Ellipse-Flex(R), DDD, Denmark) using a split-face comparative method, comparing both sides with respect to improvement of telangiectasia, irregular pigmentation, and overall patient satisfaction. RESULTS: Comparison of the efficacy and safety between the VL and PR applicators revealed that the VL applicator was not specific for vascular lesions and that the PR applicator was not specific for pigmented lesions. Additionally, VL is not better than PR for vascular lesions (p=0.80, McNemar test) and PR is not better than VL for pigmented lesions (p=0.80, McNemar test). Finally, improvements in skin texture were not significantly different between VL and PR (p=0.80, McNemar test). CONCLUSION: The two IPL wavelength bands were found to be effective in the treatment of photo-damaged facial skin. The difference between the two treatment procedures with regard to clinical efficacy and safety was not significant.
Asian Continental Ancestry Group
;
Dichlorodiphenyldichloroethane
;
Humans
;
Pigmentation
;
Skin
;
Telangiectasis
;
Xenon

Result Analysis
Print
Save
E-mail