1.Micromorphological characteristics of the pedicle of the lower cervical vertebra
Kun LI ; Shaojie ZHANG ; Jun SHI ; Jian WANG ; Yanan LIU ; Lan DUO ; Yang YANG ; Yunteng HAO ; Zhijun LI ; Xing WANG
Chinese Journal of Tissue Engineering Research 2024;28(12):1890-1894
BACKGROUND:The lower cervical vertebral pedicle is the main stress site of the posterior column of the spine,which is of great significance for the maintenance of the stability of the human center of gravity and the reduction of shock.At present,there are few reports on the characteristics of the internal bone trabeculae,and the characteristics of the joint site of the vertebral pedicle with the articular process and the vertebral body.It is urgent to understand the fine anatomical structure of the vertebral pedicle and the relationship and function of each part. OBJECTIVE:To observe the microanatomical morphology of the vertebral pedicle by Micro-CT scanning of cervical vertebra specimens,and to measure and analyze the microstructure and morphometric parameters of the bone trabecula in the cervical pedicle under normal conditions to evaluate the safety performance of the cervical spine. METHODS:Micro-CT scanning was performed on 31 sets of cervical vertebrae C3-C7.By checking and reconstructing the areas of interest in the bone trabecular within the vertebral pedicle,the morphological characteristics and distribution direction of the bone trabecular within the cervical pedicle were observed,and the bone microstructure parameters were detected,and the differences in the bone microstructure of the C3-C7 vertebral pedicle were analyzed and compared. RESULTS AND CONCLUSION:(1)The Micro-CT images showed that the honeycomb bone trabeculae of the pedicle of the lower cervical spine presented a complex network of microstructures.The trabeculae near the cortical bone were lamellar and relatively compact,extending forward toward the vertebral body and backward toward the articular process lamina.Abatoid bone trabeculae extended into the medullary cavity and transformed into a network structure,and then into rod-shaped bone trabeculae.The rod-shaped bone trabeculae were sparsely distributed in the medullary cavity.(2)Statistical results of morphological parameters of bone trabeculae showed that bone volume fraction values in C4 and C5 were higher than that in C7(P<0.05).The bone surface/bone volume value in C7 was higher than that in C3,C4 and C6(P<0.05).The bone surface density of bone trabeculae in C7 was higher than that in C3,C4,C5 and C6(P<0.05).Trabecular thickness in C7 was higher than that in C3,C4 and C5(P<0.05).Bone surface/bone volume and bone surface density of the left pedicle bone trabecular were greater than those on the right side(P<0.05).(3)The microstructural changes of C3-C7 were summarized,in which the load capacity and stress of the C7 pedicle were poor,and the risk of injury was high in this area.
2.Research on Diagnosis Model of Endometrial Lesions by Hysteroscopy Based on Deep Learning Algorithm Combined with Grad-CAM
Mingliang CAO ; Mi YIN ; Qingbin WANG ; Hanfeng ZHU ; Xing LI ; Jun ZHANG ; Lin MAO ; Xuefeng MU ; Min CAO ; Yutao MA ; Jian WANG ; Yan ZHANG
Journal of Practical Obstetrics and Gynecology 2024;40(5):409-413
Objective:To explore the effectiveness of a hysteroscopic endometrial lesion diagnosis model de-veloped based on deep learning(DL)algorithm combined with gradient-weighted class activation mapping(Grad-CAM)visualization technology.Methods:303 hysteroscopy videos(4781 images)of 291 patients who un-derwent hysteroscopy examination in the Department of Gynecology,Renmin Hospital of Wuhan University from June 1,2021 to December 31,2022 were selected.The dataset was divided into a training set(3703 images)and a test set(1078 images)by weight sampling method.After the training set was used for model learning and train-ing,two model architectures,residual neural network(ResNet18)and efficient neural network(EfficientNet-B0),were selected to verify the model in the test set by five-class and two-class classification tasks,respectively.Tak-ing histopathology as the gold standard,the diagnostic efficacy was evaluated to select the optimal model,and the Grad-CAM layer was embedded in the optimal model to output hysteroscopy images of Grad-CAM.Results:①In the five-class classification tasks,the accuracy of EfficientNet-B0 model(93.23%)was higher than that of Res-Net18 model(84.23%);the area under the curve(AUC)of EfficientNet-B0 model in the diagnosis of five disea-ses,including atypical endometrial hyperplasia,endometrial polyps,endometrial cancer,endometrial atypical hy-perplasia,and submucous myoma,was slightly higher than that of ResNet18 model,and the AUC of both models was almost above 0.980.②In the binary classification task of accuracy and the evaluation of specificity,the two models were similar,both above 93.00%,and the sensitivity of EfficientNet-B0 model(91.14%)was significantly better than that of ResNet18 model(77.22%).③EfficientNet-B0 model combined with Grad-CAM algorithm could identify the abnormal areas in the image.After biopsy and pathological examination,it was confirmed that about 95%of the marked areas in the model's output heatmap were lesion areas.Conclusions:The hysteroscopy di-agnostic model developed by EfficientNet-B0 model combined with Grad-CAM has high diagnostic accuracy,sen-sitivity,and specificity,and has application value in the diagnosis of endometrial lesions.
3.Arthroscopic all-inside reconstruction of isolated posterior cruciate ligament injury
Jian XIAO ; Hao LI ; Jun YAN ; Fan HU ; Ce WANG ; Gengyan XING
Chinese Journal of Orthopaedics 2024;44(3):139-145
Objective:To investigate the indications and effects of arthroscopic all-inside reconstruction in the treatment of isolated posterior cruciate ligament (PCL) injury.Methods:A retrospective analysis was performed on 47 patients with isolated PCL injury, who underwent arthroscopic all-inside reconstruction in the Third Medical Center of the PLA General Hospital from January 2016 to January 2020. There were 39 males and 8 females, aged 27.14±7.70 years old (range 16-40 years old). The preoperative kneeling-position stress X-ray showed that the degree of tibial posterior displacement was 8-10 mm, which was a complete and isolated Grade II PCL injury. The tibial and femoral tunnels were created through posterior-medial, anteromedial, and anterolateral portals, while the lateral portal to the medial femoral condyle was enlarged to position the tibial tunnel and protect the anterior cruciate ligament. The autologous graft tendon was pulled through the femoral and tibial tunnels secured with an adjustable loop plate. The efficacy was evaluated by evaluating and comparing preoperative and postoperative Lachman test, posterior drawer test, knee range of motion and relaxation, pain visual analogue scale (VAS) and Lysholm score.Results:43 patients were followed up for 35.21±3.88 months (range 12-40 months). The symptoms of knee instability all improved after surgery. At the follow-up of 1 year after surgery, 41 (95%) and 40 (93%) patients showed normal or I-degree laxity in Lachman test and posterior drawer test, respectively. The active range of motion and passive flexion of the knee joint were increased to 90°-110° and 110°-130°, respectively. The Lysholm score was 86.44±4.08 at the first year of follow-up and 90.12±3.33 at the last follow-up with significant difference compared with pre-operations ( P<0.05). The VAS score was 2.07±0.94 at the first year of follow-up and 1.28±0.83 at the last follow-up with significant difference compared with pre-operations ( P<0.05). The Lysholm score and VAS were 90.12±3.33 and 1.28±0.83, which were significantly improved compared to 1-year-follow-up ( P<0.05). Conclusion:Routine kneeling stress X-rays can evaluate the degree of tibial posterior displacement in isolated PCL injuries. With tibial posterior displacement equal to or greater than 10 mm, surgical reconstruction was required. All-inside reconstruction of isolated PCL injury was a safe and minimally invasive surgery to improve symptoms and restore knee functions.
4.Investigation of metabolites of 2-methyl-dechloroketamine in vitro
Jun-hui RU ; Feng HUANG ; Hao WU ; Min-hao WANG ; Xing KE ; Jian-hong GAO ; Yi-lei FAN
Acta Pharmaceutica Sinica 2024;59(5):1357-1363
The abuse of novel phenylcyclohexylpyridine drugs poses a significant threat to societal safety. The novel psychoactive substance 2-methyl-deschloroketamine (2-MDCK), belonging to the phenylcyclohexylpyridine class, has recently surfaced as a new compound. However, there is a lack of understanding regarding its metabolic pathways and the identification of suitable biomarkers. In this study, a human liver microsomal model was established, and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) technology was applied to investigate the
5.Clinical and genetic features of children with 3-methylcrotonyl-coenzyme A carboxylase deficiency:an analysis of six cases
Li-Ming ZHANG ; Sheng-Nan WU ; Ya-Nan GUO ; Jian-Wei YANG ; Hong-Qi SUN ; Jun-Mei YANG ; Yong-Xing CHEN
Chinese Journal of Contemporary Pediatrics 2024;26(8):845-851
Objective To investigate the clinical and genetic features of children with 3-methylcrotonyl-coenzyme A carboxylase deficiency(MCCD).Methods A retrospective analysis was conducted on the clinical manifestations and genetic testing results of six children with MCCD who attended Children's Hospital Affiliated to Zhengzhou University from January 2018 to October 2023.Results Among the six children with MCCD,there were 4 boys and 2 girls,with a mean age of 7 days at the time of attending the hospital and 45 days at the time of confirmed diagnosis.Of all children,one had abnormal urine odor and five had no clinical symptoms.All six children had increases in blood 3-hydroxyisovaleryl carnitine and urinary 3-hydroxyisovaleric acid and 3-methylcrotonoylglycine,and five of them had a reduction in free carnitine.A total of six mutations were identified in the MCCC1 gene,i.e.,c.1630del(p.R544Dfs*2),c.269A>G(p.D90G),c.1609T>A(p.F537I),c.639+2T>A,c.761+1G>T,and c.1331G>A(p.R444H),and three mutations were identified in the MCCC2 gene,i.e.,c.838G>T(p.D280Y),c.592C>T(p.Q198*,366),and c.1342G>A(p.G448A).Among these mutations,c.269A>G(p.D90G)and c.1609T>A(p.F537I)had not been previously reported in the literature.There was one case of maternal MCCD,and the child carried a heterozygous mutation from her mother.Five children with a reduction in free carnitine were given supplementation of L-carnitine,and free carnitine was restored to the normal level at the last follow-up visit.Conclusions This study identifies two new mutations,c.269A>G(p.D90G)and c.1609T>A(p.F537I),thereby expanding the mutation spectrum of the MCCC1 gene.A combination of blood amino acid and acylcarnitine profiles,urine organic acid analysis,and genetic testing can facilitate early diagnosis and treatment of MCCD,and provide essential data for genetic counseling.
6.Antimicrobial resistance of bacteria from intensive care units:surveillance report from Hunan Province Antimicrobial Resistance Surveillance Sys-tem,2012-2021
Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Jun LIU ; Xing-Wang NING ; Guo-Min SHI ; Jing-Min WU ; Huai-De YANG ; Hong-Xia YUAN ; Ming ZHENG ; Nan REN ; Xun HUANG ; An-Hua WU ; Jian-Dang ZHOU
Chinese Journal of Infection Control 2024;23(8):942-953
Objective To investigate the distribution and antimicrobial susceptibility of clinically isolated bacteria from intensive care units(ICUs)in hospitals of Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021.Methods According to China Antimicrobial Resistance Surveillance System,data of clinically isolated bacterial strains and antimicrobial susceptibility testing results of bacteria from ICUs reported by all member units of Hunan Province Antimicrobial Resistance Surveillance System were analyzed with WHONET 2022 software.Results From 2012 to 2021,the total number of bacteria isolated from ICUs of member units of the Hunan Province Antimi-crobial Resistance Surveillance System was 5 777-22 369,with Gram-negative bacteria accounting for 76.1%-78.0%annually.Staphylococcus aureus ranked first among isolated Gram-positive bacteria each year.The top 5 bacteria among Gram-negative bacteria were Acinetobacter baumannii,Klebsiella pneumoniae,Escherichia coli,Pseudo-monas aeruginosa,and Stenotrophomonas maltophilia.Detection rate of methicillin-resistant Staphylococcus aureus showed a downward trend year by year.No Staphylococcus spp.were found to be resistant to vancomycin,teico-planin and linezolid.Detection rates of vancomycin-resistant Enterococcus faecalis and vancomycin-resistant Entero-coccus faecium were 0.6-1.1%and 0.6%-2.2%,respectively.Resistance rates of Escherichia coli and Kleb-siella pneumoniae to imipenem were 3.1%-5.7%and 7.7%-20.9%,respectively.Resistance rates of Pseudo-monasaeruginosa and Acinetobacter baumannii to imipenem were 24.6%-40.1%and 76.1%-80.9%,respective-ly.Detection rates of carbapenem-resistant Pseudomonas aeruginosa declined year by year.Acinetobacter baumannii maintained high susceptibility to polymyxin B,with resistance rate<10%.Conclusion Antimicrobial resistance of bacteria from ICUs is serious.Carbapenem-resistant Enterobacteriales has an upward trend after 2019.It is nece-ssary to strengthen the surveillance of bacterial resistance and carry out multidisciplinary collaboration.
7.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
8.Curative effect analysis of anterior cervical discectomy and fusion in patients with cervical spondylosis of vertebral artery type
Yi-Xiang AI ; Jian-Tao LIU ; Ding-Jun HAO ; Xi GONG ; Yi-Han ZHU ; Xing-Yuan LI ; Xi-Wei ZHANG ; Kao WANG ; Jia-Jun SUN ; Shu-Yuan ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(7):670-675
Objective To investigate the clinical effect of anterior cervical discectomy and fusion(ACDF)in the treatment of cervical spondylosis of vertebral artery type(CSA).Methods The clinical data of 42 patients with CSA from January 2020 to January 2022 were retrospectively analyzed.There were 25 males and 17 females,aged from 30 to 74 years old with an average of(53.9±11.0)years old.There were 18 cases with single-segment lesions,17 cases with two-segment lesions,and 7 cases with three-segment lesions.The American Academy of Otolaryngology-Head and Neck Surgery's Hearing and Balance Committee score(CHE),the Neck Disability Index(NDI)and the cervical curvature Cobb angle were recorded before surgery and after surgery at 6 months.Results All 42 ACDF patients were followed up for 6 to 30 months with an average of(14.0±5.2)months.The operative time ranged from 95 to 220 min with an average of(160.38±36.77)min,the intraoperative blood loss ranged from 30 to 85 ml with an average of(53.60±18.98)ml.Tow patients had mild postoperative dysphagia,which improved with symptomatic treatment such as nebulized inhalation.CHE score decreased from(4.05±0.96)preoperatively to(2.40±0.70)at 6 months postoperatively(t=12.97,P<0.05).The number of improved vertigo at 6 months postoperatively was 38,with an im-provement rate of 90.5%.NDI score was reduced from(34.43±8.04)preoperatively to(20.76±3.91)at 6 months postopera-tively(t=1 1.83,P<0.05).The cervical curvature Cobb angle improved from(8.04±6.70)° preoperatively to(12.42±5.23)° at 6 months postoperatively(t=-15.96,P<0.05).Conclusion The ACDF procedure has outstanding clinical efficacy in treating CSA.The operation can rapidly relieve patients'episodic vertigo symptoms by relieving bony compression and reconstructing cervical curvature.However,it is necessary to strictly grasp the indications for surgery and clarify the causes of vertigo in pa-tients,and ACDF surgery is recommended for CSA patients for whom conservative treatment is ineffective.
9.Radiofrequency ablation on prosthetic valve for atrial tachycardia after transcatheter aortic valve replacement
Hong-Xiao LI ; Bi-Jun HUANG ; Lu-Xin WANG ; Xing-Xu WANG ; Yun-Kai WANG ; Xiao-Yan HE ; Jian-Qiang ZHANG
Chinese Journal of Interventional Cardiology 2024;32(4):232-235
Transcatheter aortic valve replacement(TAVR)has emerged as a promising therapeutic alternative for addressing aortic valve-related pathologies.However,the occurrence of rapid arrhythmias linked to TAVR procedures is progressively drawing scrutiny.Presently,pharmacologic interventions constitute the mainstay of managing atrial arrhythmias related to TAVR,while the potential of ablation as a viable treatment modality remains undefined.Notably,in cases where the arrhythmia's genesis is presumed to be intricately linked to the prosthetic valve,the practicality and safety of ablation procedures remain unverified.Our institution has successfully ventured into radiofrequency ablation for a distinctive patient presenting with this intricate condition,thereby tentatively affirming the efficacy and safety of catheter ablation administered on the surface of prosthetic valves.
10.Research on Diagnosis Model of Endometrial Lesions by Hysteroscopy Based on Deep Learning Algorithm Combined with Grad-CAM
Mingliang CAO ; Mi YIN ; Qingbin WANG ; Hanfeng ZHU ; Xing LI ; Jun ZHANG ; Lin MAO ; Xuefeng MU ; Min CAO ; Yutao MA ; Jian WANG ; Yan ZHANG
Journal of Practical Obstetrics and Gynecology 2024;40(5):409-413
Objective:To explore the effectiveness of a hysteroscopic endometrial lesion diagnosis model de-veloped based on deep learning(DL)algorithm combined with gradient-weighted class activation mapping(Grad-CAM)visualization technology.Methods:303 hysteroscopy videos(4781 images)of 291 patients who un-derwent hysteroscopy examination in the Department of Gynecology,Renmin Hospital of Wuhan University from June 1,2021 to December 31,2022 were selected.The dataset was divided into a training set(3703 images)and a test set(1078 images)by weight sampling method.After the training set was used for model learning and train-ing,two model architectures,residual neural network(ResNet18)and efficient neural network(EfficientNet-B0),were selected to verify the model in the test set by five-class and two-class classification tasks,respectively.Tak-ing histopathology as the gold standard,the diagnostic efficacy was evaluated to select the optimal model,and the Grad-CAM layer was embedded in the optimal model to output hysteroscopy images of Grad-CAM.Results:①In the five-class classification tasks,the accuracy of EfficientNet-B0 model(93.23%)was higher than that of Res-Net18 model(84.23%);the area under the curve(AUC)of EfficientNet-B0 model in the diagnosis of five disea-ses,including atypical endometrial hyperplasia,endometrial polyps,endometrial cancer,endometrial atypical hy-perplasia,and submucous myoma,was slightly higher than that of ResNet18 model,and the AUC of both models was almost above 0.980.②In the binary classification task of accuracy and the evaluation of specificity,the two models were similar,both above 93.00%,and the sensitivity of EfficientNet-B0 model(91.14%)was significantly better than that of ResNet18 model(77.22%).③EfficientNet-B0 model combined with Grad-CAM algorithm could identify the abnormal areas in the image.After biopsy and pathological examination,it was confirmed that about 95%of the marked areas in the model's output heatmap were lesion areas.Conclusions:The hysteroscopy di-agnostic model developed by EfficientNet-B0 model combined with Grad-CAM has high diagnostic accuracy,sen-sitivity,and specificity,and has application value in the diagnosis of endometrial lesions.

Result Analysis
Print
Save
E-mail