1.Dorsal plate assisted fixation of dorsal lunate fossa fracture of distal radius.
Jun QIAN ; Kai-Ming JIANG ; Kun-Zhi SU ; Jun-Hong LIN ; Mei-Yuan FANG
China Journal of Orthopaedics and Traumatology 2023;36(8):782-785
OBJECTIVE:
To explore clinical efficacy of dorsal plate assisted fixation of dorsal lunate fossa fracture block of distal radius.
METHODS:
From January 2019 to January 2022, 30 patients were treated with dorsal plate assisted fixation of dorsal lunate fossa fracture of distal radius, including 13 males and 17 females, aged from 42 to 68 years old with an average of (48.7±5.6) years old;According to Doi fracture classification, 24 patients were type 3 blocks and 6 patients were type 4 blocks. The degree of palmar angle of anterior and posterior distal radius was fixed by dorsal steel plate during operation. Fracture healing and functional recovery of wrist were observed after operation. Functional evaluation was performed by Gartland and Werley scoring system at 12 months after operation.
RESULTS:
All patients were followed up from 12 to 13 months with an average of (11.3±0.9) months. All fractures healed for 4 to 5 months with an average of(4.7±0.8) months. Median palpal inclination of anterior and posterior distal radius fixed by dorsal plate was 5.30°(4.85°, 6.03°), 12.45°(11.98°, 13.43°) respectively, and had statistical difference( P<0.01). Gartland and Werley scores was (1.1±0.4) at 12 months afteropertaion, and 27 patients got excellent result and 3 good.
CONCLUSION
Dorsal plate assisted fixation of dorsal lunate fossa fractures is beneficial to reduction and stabilization of displaced dorsal fractures and restoration of palmar inclination.
Female
;
Male
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Radius/surgery*
;
Lunate Bone/surgery*
;
Upper Extremity
;
Wrist Joint
;
Wrist
;
Fractures, Bone
2.Analysis of the causes of soft tissue complications after volar locking plate for the treatment of dorsal displaced distal radius fractures.
Jin-Gu TAI ; Zhi-Yong DING ; Liang SUN ; Yun-Ping CAO ; Guo-Bao YE ; Peng HAO ; Wei LI
China Journal of Orthopaedics and Traumatology 2023;36(9):839-845
OBJECTIVE:
To investigate the causes of soft tissue complications in patients with dorsal displacement distal radius fractures (DRF) after volar locking plate surgery.
METHODS:
From July 2016 to May 2021, 112 patients with dorsal displacement DRF were treated with volar locking plate surgery, including 45 males and 67 females. The average age was (46.24±10.08) years old, ranging from 18 to 85 years old. According to whether there were soft tissue complications after operation, they were divided into complication group (40 cases) and non complication group (72 cases). Compared with preoperation, the radial metacarpal inclination and ulnar deflection angle, wrist flexion activity and dorsal extension activity, and grip strength of patients after operation were significantly improved (P<0.05). Compared with the non complication group, the proportion of patients in the complication group whose age was>60 years, body mass index (BMI) more than 30 kg·m-2, smoking, diabetes, fracture type C, open fracture and operation time more than 90 min was higher (P<0.05). The age, BMI, smoking, diabetes, fracture AO classification, fracture type and operation time were analyzed by multifactor Logistic regression to determine the independent risk factors affecting the occurrence of postoperative soft tissue complications of patients, establish a nomogram prediction model, and evaluate the model.
RESULTS:
At the latest follow-up, the excellent and good rate of wrist joint function recovery was 83.93% (94/112), and the excellent and good rate of fracture reduction was 84.82% (95/112). Multivariate Logistic regression analysis showed that age more than 60 years old, diabetes, fracture type C, open fracture and operation time more than 90 min were independent risk factors for postoperative soft tissue complications (P<0.05). The receiver operating characteristic (ROC), calibration curve and clinical decision curve of the nomogram prediction model showed discrimination, accuracy and validity were good.
CONCLUSION
Age more than 60 years, diabetes mellitus, fracture type C, open fracture, and operation time more than 90 min are all independent risk factors for soft tissue complications after DRF volar plate fixation. In clinical treatment, perioperative soft tissue management should be done in such patients to prevent complications.
Female
;
Male
;
Humans
;
Adult
;
Middle Aged
;
Adolescent
;
Young Adult
;
Aged
;
Aged, 80 and over
;
Wrist Fractures
;
Fractures, Open
;
Risk Factors
;
Wrist Joint/surgery*
;
Metacarpal Bones
4.Effect of Wrist-Ankle Acupuncture on Postoperative Analgesia after Total Knee Arthroplasty.
Hai-Tao CAO ; Wan ZHANG ; Cheng LUO ; Hong-Bo ZHAO ; Jian-Ming LIU
Chinese journal of integrative medicine 2023;29(3):253-257
OBJECTIVE:
To evaluate the effect of wrist-ankle acupuncture (WAA) in pain and functional recovery after total knee arthroplasty (TKA).
METHODS:
From June to September 2020, 94 participants were included from the Second Hospital of Tangshan and randomly assigned to the WAA group (47 cases) and the sham WAA group (47 cases) by a random number table, receiving real or sham WAA treatment, respectively. The primary outcome measure involved the visual analogue scale (VAS) scores at rest and in motion. The secondary outcomes involved the range of motion (ROM) of the knee joints, straight-leg raising time, postoperative weight-bearing time, sufentanil consumption within 48 h of patient-controlled analgesia (PCA) pump, length of hospital stay, and postoperative complications.
RESULTS:
The VAS scores on the 3rd, 5th, and 7th postoperative days at rest and in motion was significantly lower in the WAA group than that of the sham WAA group (P<0.01). The ROM on the 1st, 2nd, and 3rd PODs was significantly higher in the WAA group than that of the sham WAA group (P<0.01). In comparison to the sham WAA group, the sufentanil consumption within 48 h of PCA pump was significantly less in the WAA group (156.3 ± 12.2 µg vs. 128.8 ± 9.8 µg, P<0.01). There was no significant difference in active straight-leg raising time, postoperative weight-bearing time, length of hospital stay, and postoperative complications between the two groups (P>0.05).
CONCLUSIONS
WAA could alleviate post-TKA pain, improve knee joint function, and reduce the sufentanil consumption within 48 h of PCA pump. WAA is a safe and effective treatment in the perioperative analgesic management for TKA.
Humans
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Ankle
;
Wrist
;
Sufentanil
;
Pain, Postoperative/therapy*
;
Acupuncture Therapy/adverse effects*
;
Analgesia
;
Knee Joint
5.Analysis of the effectiveness of sequential plate internal fixation in correction of Madelung deformity after ulnar osteotomy and shortening.
Wei WANG ; Xiaowen DENG ; Wenbo LI ; Miaomiao YANG ; Yaqiang ZHANG ; Peisheng SHI ; Weiwei SHEN ; Rui LIU ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):810-814
OBJECTIVE:
To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.
METHODS:
The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.
RESULTS:
After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.
CONCLUSION
Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.
Male
;
Female
;
Humans
;
Adolescent
;
Retrospective Studies
;
Ulna/surgery*
;
Osteochondrodysplasias
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Osteotomy
;
Range of Motion, Articular
;
Treatment Outcome
6.Clinical analysis of distal radius core decompression for chronic wrist pain.
Jixin WU ; Jiayu SUN ; Xin LIU ; Jie SONG ; Shaonan HU ; Liang CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):815-820
OBJECTIVE:
To investigate the effectiveness of distal radius core decompression in the treatment of chronic wrist pain caused by various etiologies.
METHODS:
A retrospective analysis was performed for the clinical data of 10 patients with chronic wrist pain treated with distal radial core decompression between January 2018 and December 2021. There were 6 males and 4 females with an average age of 37.4 years (range, 21-55 years). The disease duration ranged from 7 to 72 months, with an average of 26.5 months. Preoperative MRI examination showed that 10 cases had bone marrow edema at the distal radius on the affected side, and 8 cases had bone marrow edema in the carpal bones such as scaphoid and lunate bone. Among them, 3 patients had a history of wrist fracture, and 2 patients had Kienböck diseases (1 case each in stage ⅡB and stage ⅢA). Three cases were combined with triangular fibrocartilage complex (TFCC) type 1A injury. Two cases were combined with osteoarthritis, 1 of them was complicated with severe traumatic arthritis, the wrist arthroscopy showed that the TFCC was completely lost and could not be repaired, and the cartilage of the lunate bone and the ulnar head were severely worn.Visual analogue scale (VAS) score was used to evaluate the relief of wrist pain before operation, at 6 months after operation, and at last follow-up, and the range of motion of the affected wrist in dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was measured. The degree of bone marrow edema was evaluated according to T1WI, T2WI, and STIR sequences of MRI.
RESULTS:
All the patients were followed up 12-22 months, with an average of 16.4 months. Except for 1 patient who experienced persistent wrist joint pain and limited mobility after operation, the remaining 9 patients showed significant improvement in pain symptoms and wrist joint mobility. The VAS score and range of motion of wrist dorsiflexion, palmar flexion, ulnar deviation, and radial deviation at 6 months after operation and at last follow-up were significantly improved when compared with those before operation, the VAS score and the range of motion of wrist ulnar deviation and radial deviation at last follow-up were further improved when compared with those at 6 months after operation, all showing significant differences ( P<0.05). There was no significant difference in wrist dorsiflexion and palmar flexion between at 6 months after operation and at last follow-up ( P>0.05). Bone marrow edema was improved in 6 patients on MRI at 6 months after operation, and was also improved in other patients at last follow-up.
CONCLUSION
For chronic wrist pain caused by a variety of causes, distal radius core decompression can directly reduce the pressure of the medullary cavity of the distal radius, improve the blood supply of the corresponding distal structure, significantly alleviate chronic wrist pain, and provide an option for clinical treatment.
Male
;
Female
;
Humans
;
Adult
;
Radius/surgery*
;
Wrist
;
Retrospective Studies
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Scaphoid Bone/surgery*
;
Pain
;
Arthralgia/complications*
;
Arthroscopy
;
Decompression
;
Range of Motion, Articular
;
Treatment Outcome
7.Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis.
Bin WANG ; Xingbo CAI ; Yue ZHANG ; Bihuan ZHANG ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):821-826
OBJECTIVE:
To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.
METHODS:
One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.
RESULTS:
The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.
CONCLUSION
The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.
Humans
;
Lunate Bone/surgery*
;
Finite Element Analysis
;
Titanium
;
Wrist Joint/surgery*
;
Artificial Limbs
;
Range of Motion, Articular
;
Biomechanical Phenomena
8.Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach.
Hai-Bo XIA ; Jun LAN ; Li-Qing JIANG ; Hua-Fei YANG ; Xiao-Hui NIU
China Journal of Orthopaedics and Traumatology 2023;36(4):376-380
OBJECTIVE:
To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.
METHODS:
From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.
RESULTS:
All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.
CONCLUSION
Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.
Adult
;
Aged
;
Animals
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
Radius/surgery*
;
Radius Fractures/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Wrist Joint
9.The analysis of the therapeutic effect for 10 cases of type C extreme distal radial fracture in micro needle plate internal fixation.
Bing LIU ; Xiang-Yu MA ; Chao YANG ; Da-Peng ZHOU
China Journal of Orthopaedics and Traumatology 2023;36(6):574-578
OBJECTIVE:
To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.
METHODS:
This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.
RESULTS:
The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.
CONCLUSION
Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Retrospective Studies
;
Reproducibility of Results
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Wrist Fractures
;
Wrist Joint
;
Bone Plates
;
Range of Motion, Articular
10.Three-dimensional analysis of the gap space under forearm casts.
Roman WIRTZ ; Silvia PIANIGIANI ; Bernardo INNOCENTI ; Frédéric SCHUIND
Chinese Journal of Traumatology 2022;25(2):77-82
PURPOSE:
Secondary displacement represents a frequent complication of conservative treatment of fractures, particularly of the distal radius. The gap space between skin and cast may lead to a certain degree movements and this increased mobility might favor redisplacement. The aim of this study was to develop a new 3D method, to measure the gap space in all 3 geometrical planes, and to validate this new technique in a clinical setting of distal radius fractures.
METHODS:
This study applies 3D imaging to measure the space between plaster and skin as a potential factor of secondary displacement and therefore the failure of conservative treatment. We developed and validated a new methodology to analyze and compare different forearm casts made of plaster of Paris and fiberglass. An unpaired t-test was performed to document differences between the investigated parameters between plaster of Paris and fiberglass casts. The significance level was set at p < 0.05.
RESULTS:
In a series of 15 cases, we found the width of the gap space to average 4 mm, being slightly inferior on the radial side. Comparing the two different casting materials, plaster of Paris and fiberglass, we found a significantly larger variance of space under casts made of the first material (p=0.39). A roughness analysis showed also a markedly significantly higher irregularity of the undersurface of plaster of Paris as compared with fiberglass.
CONCLUSION
This study allows for a better understanding of the nature of the "gap space" between cast and skin and will contribute to develop and improve new immobilization techniques and materials.
Casts, Surgical
;
Forearm
;
Humans
;
Radius
;
Radius Fractures/therapy*
;
Wrist Joint

Result Analysis
Print
Save
E-mail