1.Arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.
Yong LI ; Yongbin FU ; Mingming MA ; Siwei MEI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1386-1389
OBJECTIVE:
To explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.
METHODS:
The clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation ( t=12.851, P<0.001; t=-14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair.
CONCLUSION
Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.
Male
;
Humans
;
Female
;
Adult
;
Fractures, Bone/surgery*
;
Bone Wires
;
Scaphoid Bone/injuries*
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Fractures, Ununited/surgery*
;
Wrist Injuries/surgery*
;
Bone Screws
;
Hand Injuries
;
Treatment Outcome
2.Dorsal plate assisted fixation of dorsal lunate fossa fracture of distal radius.
Jun QIAN ; Kai-Ming JIANG ; Kun-Zhi SU ; Jun-Hong LIN ; Mei-Yuan FANG
China Journal of Orthopaedics and Traumatology 2023;36(8):782-785
OBJECTIVE:
To explore clinical efficacy of dorsal plate assisted fixation of dorsal lunate fossa fracture block of distal radius.
METHODS:
From January 2019 to January 2022, 30 patients were treated with dorsal plate assisted fixation of dorsal lunate fossa fracture of distal radius, including 13 males and 17 females, aged from 42 to 68 years old with an average of (48.7±5.6) years old;According to Doi fracture classification, 24 patients were type 3 blocks and 6 patients were type 4 blocks. The degree of palmar angle of anterior and posterior distal radius was fixed by dorsal steel plate during operation. Fracture healing and functional recovery of wrist were observed after operation. Functional evaluation was performed by Gartland and Werley scoring system at 12 months after operation.
RESULTS:
All patients were followed up from 12 to 13 months with an average of (11.3±0.9) months. All fractures healed for 4 to 5 months with an average of(4.7±0.8) months. Median palpal inclination of anterior and posterior distal radius fixed by dorsal plate was 5.30°(4.85°, 6.03°), 12.45°(11.98°, 13.43°) respectively, and had statistical difference( P<0.01). Gartland and Werley scores was (1.1±0.4) at 12 months afteropertaion, and 27 patients got excellent result and 3 good.
CONCLUSION
Dorsal plate assisted fixation of dorsal lunate fossa fractures is beneficial to reduction and stabilization of displaced dorsal fractures and restoration of palmar inclination.
Female
;
Male
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Radius/surgery*
;
Lunate Bone/surgery*
;
Upper Extremity
;
Wrist Joint
;
Wrist
;
Fractures, Bone
3.Analysis of the causes of soft tissue complications after volar locking plate for the treatment of dorsal displaced distal radius fractures.
Jin-Gu TAI ; Zhi-Yong DING ; Liang SUN ; Yun-Ping CAO ; Guo-Bao YE ; Peng HAO ; Wei LI
China Journal of Orthopaedics and Traumatology 2023;36(9):839-845
OBJECTIVE:
To investigate the causes of soft tissue complications in patients with dorsal displacement distal radius fractures (DRF) after volar locking plate surgery.
METHODS:
From July 2016 to May 2021, 112 patients with dorsal displacement DRF were treated with volar locking plate surgery, including 45 males and 67 females. The average age was (46.24±10.08) years old, ranging from 18 to 85 years old. According to whether there were soft tissue complications after operation, they were divided into complication group (40 cases) and non complication group (72 cases). Compared with preoperation, the radial metacarpal inclination and ulnar deflection angle, wrist flexion activity and dorsal extension activity, and grip strength of patients after operation were significantly improved (P<0.05). Compared with the non complication group, the proportion of patients in the complication group whose age was>60 years, body mass index (BMI) more than 30 kg·m-2, smoking, diabetes, fracture type C, open fracture and operation time more than 90 min was higher (P<0.05). The age, BMI, smoking, diabetes, fracture AO classification, fracture type and operation time were analyzed by multifactor Logistic regression to determine the independent risk factors affecting the occurrence of postoperative soft tissue complications of patients, establish a nomogram prediction model, and evaluate the model.
RESULTS:
At the latest follow-up, the excellent and good rate of wrist joint function recovery was 83.93% (94/112), and the excellent and good rate of fracture reduction was 84.82% (95/112). Multivariate Logistic regression analysis showed that age more than 60 years old, diabetes, fracture type C, open fracture and operation time more than 90 min were independent risk factors for postoperative soft tissue complications (P<0.05). The receiver operating characteristic (ROC), calibration curve and clinical decision curve of the nomogram prediction model showed discrimination, accuracy and validity were good.
CONCLUSION
Age more than 60 years, diabetes mellitus, fracture type C, open fracture, and operation time more than 90 min are all independent risk factors for soft tissue complications after DRF volar plate fixation. In clinical treatment, perioperative soft tissue management should be done in such patients to prevent complications.
Female
;
Male
;
Humans
;
Adult
;
Middle Aged
;
Adolescent
;
Young Adult
;
Aged
;
Aged, 80 and over
;
Wrist Fractures
;
Fractures, Open
;
Risk Factors
;
Wrist Joint/surgery*
;
Metacarpal Bones
6.Clinical application of special fluoroscopy method in the treatment of distal radius fractures with volar locking plate.
Rong ZHANG ; He-Ming NIU ; Tao GUO ; Ping-Feng XIE ; Jia-Ming WU ; Jia-Bing XIE ; Lin WANG
China Journal of Orthopaedics and Traumatology 2023;36(2):128-132
OBJECTIVE:
The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.
METHODS:
From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.
RESULTS:
All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.
CONCLUSION
The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Wrist Fractures
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Fluoroscopy/methods*
;
Bone Plates
;
Postoperative Complications
7.Treatment of acute non-displaced scaphoid fracture of wrist with syringe needle-guided percutaneous cannulated headless hollow compression screw internal fixation.
China Journal of Orthopaedics and Traumatology 2023;36(2):161-164
OBJECTIVE:
To investigate the clinical efficacy of needle-guided percutaneous cannulated compression screw fixation in the treatment of acute non-displaced scaphoid fracture of wrist.
METHODS:
The clinic data of twenty-eight patients with acute non-displaced scaphoid fracture from January 2014 to January 2019 were analyzed retrospectively. According to the intraoperative method of placement of cannulated screw, they were divided into Guide group(16 patients)and Conventional group(12 patients). There were 13 males and 3 females in Guide group, aged from 20 to 60 years old with an average of(31.42±9.71)years old;5 patients were classified as type A2, 3 patients were classified as type B1 and 8 patients were classified as type B2 according to Herbert classification;they were treated with percutaneous cannulated compression screw fixation under the guidance of needle. There were 11 males and 1 female in Conventional group, aged from 23 to 61 years old with an average of(30.51±7.52)years old;5 patients were classified as type A2, 2 patients were classified as type B1 and 5 patients were classified as type B2 according to Herbert classification;they were treated with conventional percutaneous cannulated compression screw fixation. The operation time, screw angle relative to the longitudinal axis of the scaphoid and wrist function score were assessed and compared between the two groups.
RESULTS:
A total of 28 patients were followed up from 20 to 45 months with an average of (33.00±8.72) months. None of patients had intraoperative complication and incision infection. These patients returned to work gradually 2 weeks after operation, and all fractures healed within 12 weeks. The operation time in the Guide group was significantly less than that in the Conventinal group(P<0.05). Screw angle relative to the longitudinal axis of the scaphoid in the Guide group was significantly smaller than that in the Conventional group(P<0.05). There was no significant difference in Mayo wrist function scores at the last follow-up between the two groups(P>0.05). During the follow-up period, none of the 28 patients showed internal fixation displacement, arthritis, scaphoid necrosis and other complications.
CONCLUSION
In the treatment of acute non-displaced scaphoid fractures, the operation time of needle-guided percutaneous cannulated headless compression screw fixation is significantly shorter than that of conventional percutaneous screw fixation, and the screw axis is easier to be parallel to the longitudinal axis of the scaphoid.
Male
;
Humans
;
Female
;
Young Adult
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Scaphoid Bone/surgery*
;
Wrist
;
Retrospective Studies
;
Syringes
;
Wrist Injuries/surgery*
;
Fracture Fixation, Internal/methods*
;
Bone Screws
;
Treatment Outcome
8.Analysis of the effectiveness of sequential plate internal fixation in correction of Madelung deformity after ulnar osteotomy and shortening.
Wei WANG ; Xiaowen DENG ; Wenbo LI ; Miaomiao YANG ; Yaqiang ZHANG ; Peisheng SHI ; Weiwei SHEN ; Rui LIU ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):810-814
OBJECTIVE:
To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.
METHODS:
The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.
RESULTS:
After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.
CONCLUSION
Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.
Male
;
Female
;
Humans
;
Adolescent
;
Retrospective Studies
;
Ulna/surgery*
;
Osteochondrodysplasias
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Osteotomy
;
Range of Motion, Articular
;
Treatment Outcome
9.Clinical analysis of distal radius core decompression for chronic wrist pain.
Jixin WU ; Jiayu SUN ; Xin LIU ; Jie SONG ; Shaonan HU ; Liang CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):815-820
OBJECTIVE:
To investigate the effectiveness of distal radius core decompression in the treatment of chronic wrist pain caused by various etiologies.
METHODS:
A retrospective analysis was performed for the clinical data of 10 patients with chronic wrist pain treated with distal radial core decompression between January 2018 and December 2021. There were 6 males and 4 females with an average age of 37.4 years (range, 21-55 years). The disease duration ranged from 7 to 72 months, with an average of 26.5 months. Preoperative MRI examination showed that 10 cases had bone marrow edema at the distal radius on the affected side, and 8 cases had bone marrow edema in the carpal bones such as scaphoid and lunate bone. Among them, 3 patients had a history of wrist fracture, and 2 patients had Kienböck diseases (1 case each in stage ⅡB and stage ⅢA). Three cases were combined with triangular fibrocartilage complex (TFCC) type 1A injury. Two cases were combined with osteoarthritis, 1 of them was complicated with severe traumatic arthritis, the wrist arthroscopy showed that the TFCC was completely lost and could not be repaired, and the cartilage of the lunate bone and the ulnar head were severely worn.Visual analogue scale (VAS) score was used to evaluate the relief of wrist pain before operation, at 6 months after operation, and at last follow-up, and the range of motion of the affected wrist in dorsiflexion, palmar flexion, ulnar deviation, and radial deviation was measured. The degree of bone marrow edema was evaluated according to T1WI, T2WI, and STIR sequences of MRI.
RESULTS:
All the patients were followed up 12-22 months, with an average of 16.4 months. Except for 1 patient who experienced persistent wrist joint pain and limited mobility after operation, the remaining 9 patients showed significant improvement in pain symptoms and wrist joint mobility. The VAS score and range of motion of wrist dorsiflexion, palmar flexion, ulnar deviation, and radial deviation at 6 months after operation and at last follow-up were significantly improved when compared with those before operation, the VAS score and the range of motion of wrist ulnar deviation and radial deviation at last follow-up were further improved when compared with those at 6 months after operation, all showing significant differences ( P<0.05). There was no significant difference in wrist dorsiflexion and palmar flexion between at 6 months after operation and at last follow-up ( P>0.05). Bone marrow edema was improved in 6 patients on MRI at 6 months after operation, and was also improved in other patients at last follow-up.
CONCLUSION
For chronic wrist pain caused by a variety of causes, distal radius core decompression can directly reduce the pressure of the medullary cavity of the distal radius, improve the blood supply of the corresponding distal structure, significantly alleviate chronic wrist pain, and provide an option for clinical treatment.
Male
;
Female
;
Humans
;
Adult
;
Radius/surgery*
;
Wrist
;
Retrospective Studies
;
Radius Fractures/surgery*
;
Wrist Joint/surgery*
;
Scaphoid Bone/surgery*
;
Pain
;
Arthralgia/complications*
;
Arthroscopy
;
Decompression
;
Range of Motion, Articular
;
Treatment Outcome
10.Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis.
Bin WANG ; Xingbo CAI ; Yue ZHANG ; Bihuan ZHANG ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):821-826
OBJECTIVE:
To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.
METHODS:
One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.
RESULTS:
The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.
CONCLUSION
The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.
Humans
;
Lunate Bone/surgery*
;
Finite Element Analysis
;
Titanium
;
Wrist Joint/surgery*
;
Artificial Limbs
;
Range of Motion, Articular
;
Biomechanical Phenomena

Result Analysis
Print
Save
E-mail