1.Randomized Controlled Trial of Traditional Chinese Medicine Sequential Syndrome Differentiation Protocol for Reducing Relapse Rate of Frequently Relapsing/Steroid-dependent Nephrotic Syndrome in Children
Zhuiyue WANG ; Xianqing REN ; Wenqing PAN ; Tingting XU ; Xia ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(18):126-134
ObjectiveTo assess the relapse rate, clinical efficacy, and safety of a traditional Chinese medicine (TCM) sequential syndrome differentiation protocol for frequently relapsing/steroid-dependent nephrotic syndrome (FRNS/SDNS) in children. MethodsA total of 151 children with FRNS/SDNS treated in the First Affiliated Hospital of Henan University of Chinese Medicine from December 2020 to June 2024 were randomized into an observation group (77 cases) and a control group (74 cases). Both groups received Western medicine (prednisone tablets and tacrolimus capsules). In addition, the observation group additionally underwent TCM sequential syndrome differentiation and the control group received 1/10 of the TCM dose. The 6-month intervention was followed by a 12-month follow-up, totaling 18 months of observation across seven time points (before treatment and after 1, 2, 4, 24, 52, 76 weeks of treatment). The evaluation was carried out based on the following indicators. ① The relapse rates were mainly recorded after 24, 52, 76 weeks of treatment. ② The efficacy was evaluated based on the clinical remission rates after 1, 2, 4 weeks of treatment, the time to proteinuria clearance, the levels of 24-hour urine total protein (24-h UTP), serum total protein (TP), serum albumin (ALB), cholesterol (CHO), and triglycerides (TG) and the TCM symptom scores before treatment and after 24 weeks of treatment. ③ The treatment safety was evaluated based on blood routine and levels of liver enzymes, renal function indicators and blood glucose (Glu) before treatment and after 24 weeks of treatment. Results① Relapse rate: After 24 weeks of treatment, no significant difference in relapse rate was found between the two groups. The observation group showed lower relapse rates than the control group after 52 weeks of treatment [24.2% (16/66) vs. 52.5% (31/59), χ2=10.634, P<0.01] and 76 weeks of treatment [42.4% (28/66) vs. 74.6% (44/59), χ2=13.186, P<0.01] than the control group. ② Efficacy indicators: The two groups showed no significant difference in remission rate after 1 week of treatment. The observation group demonstrated higher remission rates after 2 weeks of treatment [88.2% (67/76) vs. 74.0% (54/73), Z=-1.999, P<0.05] and 4 weeks of treatment [94.7% (72/76) vs. 82.2% (60/73), Z=-2.3589, P<0.05). In addition, the observation group had shorter time to proteinuria clearance (P<0.01). After treatment, both groups showed declined 24 h-UTP, CHO, TG, and TCM symptom scores and elevated TP and ALB levels (P<0.01), and the observation group had lower CHO, TG, and TCM symptom scores and higher TP and ALB than the control group (P<0.05). ③ Safety indicators: After treatment, both groups showed declined white blood cell count (WBC), red blood cell count (RBC), hemoglobin (HB), and alanine aminotransferase (ALT) (P<0.05, P<0.01) and elevated Glu (P<0.01) and blood urea nitrogen (BUN) (P<0.05). After 24 weeks of treatment, none of WBC, RBC, HB, PLT, ALT, AST, BUN, Cr or Glu had significant differences between groups. Moreover, the incidence of adverse reactions showed no significant difference between the two groups. ConclusionThe TCM sequential syndrome differentiation protocol effectively reduces the relapse rate, improves the remission rate, shortens the time to proteinuria clearance, raised serum protein levels, lowers blood lipid levels, and alleviates symptoms, demonstrating good clinical safety in children with FRNS/SDNS.
2.Characteristics of anterior segment structure in first-degree relatives of patients with primary angle-closure glaucoma
Wenqing LI ; Guizhen PAN ; Ping SUN ; Xu ZHANG ; Lu YANG
International Eye Science 2024;24(1):111-116
AIM: To investigate the characteristics of anterior segment structure in first-degree relatives of patients with primary angle-closure glaucoma(PACG).METHODS: A total of 48 first-degree relatives of PACG patients aged 40-60 who were treated in the Affiliated Eye Hospital of Nanchang University from September 2020 to October 2022 were selected as the observation group. Additionally, 40 cases(40 eyes)of healthy individuals without glaucoma and family history of glaucoma at the same age group were collected as the control group. They were divided into younger group(40-49 years old)and elder group(50-60 years old). All subjects were examined with ultrasound biomicroscopy(UBM)and were measured using camera measure software. The parameters mainly included anterior chamber depth(ACD), anterior chamber area(ACA), anterior chamber width(ACW), anterior segment depth(ASD), angle open distance(AOD500), trabecular iris angle(TIA), trabecular iris area(TISA500), lens vault(LV), iris curve(IC), iris thickness(IT500), scleral ciliary process angle(SCPA), and iris ciliary process distance(ICPD).RESULTS: ACD, ACA, AOD500, TISA500 and TIA in the observation group were lower than those of the control group, and LV and IC were higher than those of the control group(all P<0.05). ACD, ACA, AOD500, TISA500, and TIA of the elder group were lower than those in the age-matched control group, while LV and IC were larger than those of the age-matched control group(all P<0.05). ACD, AOD500, TISA500, and TIA of the younger observation group were smaller than those of the age-matched control group, but LV and IC were significantly larger than those of the age-matched control group(all P<0.05). ACD, ACA, AOD500, TISA500 and TIA of the elder observation group were significantly lower than those of the younger observation group, and LV and IC were significantly larger than those of the younger observation group(all P<0.05). There was a difference in the distribution of ACD between the observation group and the control group(P<0.05), and the proportion of moderate to severe shallow anterior chambers was 10 times that of the control group. Correlation analysis showed that TISA500 was positively correlated with ACD and ACA, and negatively correlated with LV and IC, and TISA500 was mainly influenced by LV. IC had a positive correlation with LV and a negative correlation with ACD and ACA.CONCLUSION: First-degree relatives of PACG with normal axial length have a high risk of angle closure. The anterior segment structures of first-degree relatives of PACG are more crowded than normal individuals, and the lens forward shift may be the initial influencing factor for narrow angle.
3.Study on the predictive value of the CT pulmonary angiography parameters from the 2022 ESC/ERS guidelines for chronic thromboembolic pulmonary hypertension
Wenqing XU ; Haoyu YANG ; Anqi LIU ; Mei DENG ; Linfeng XI ; Qiang HUANG ; Wanmu XIE ; Min LIU
Journal of Practical Radiology 2024;40(7):1056-1061
Objective To assess the predictive value of computed tomography pulmonary angiography(CTPA)cardiovascular parame-ters for chronic thromboembolic pulmonary hypertension(CTEPH)under the 2022 European Society of Cardiology/European Respiratory Society(ESC/ERS)guidelines,and to compare with the 2021 Chinese guidelines.Methods A total of 201 suspected CTEPH patients were retrospectively selected.All patients underwent right heart catheterization(RHC)and CTPA evaluation.According to the Euro-pean guidelines,they were divided into three groups:mean pulmonary artery pressure(mPAP)≤20 mmHg control group(63 cases)(1 mmHg=0.133 kPa),mPAP>20 mmHg CTEPH group(138 cases),and mPAP≥25 mmHg CTEPH group(123 cases).Inter-group comparison of CTPA cardiovascular parameters was performed,and receiver operating characteristic(ROC)curve analysis was performed for each parameter.Results Under the 2022 European guidelines,the diagnostic efficacy of the diameter of the main pulmonary artery trunk(MPAd)was the highest[area under the curne(AUC)was 0.933].The binary logistic regression analysis revealed that the MP Ad,right ventricular free wall thickness(RVWT),and interventricular septal angle(IVSA)were inde-pendent risk factors for the diagnosis of CTEPH(P<0.05).Under both the Chinese and European guidelines,the MPAd,the transverse diameter and area of the right atrium,the transverse diameter and area of the bi-ventricle,the RVWT,and the IVSA showed significant statistical differences in CTEPH and control groups(P<0.05).Conclusion Under both the Chinese and European guidelines,the MP Ad measured by CTPA has the highest diagnostic efficacy for CTEPH,while the IVSA has the strongest correlation with clinical prognostic indicators.The right atrium structure also has evaluation value.
4.A machine learning model for diagnosing acute pulmonary embolism and comparison with Wells score, revised Geneva score, and Years algorithm
Linfeng XI ; Han KANG ; Mei DENG ; Wenqing XU ; Feiya XU ; Qian GAO ; Wanmu XIE ; Rongguo ZHANG ; Min LIU ; Zhenguo ZHAI ; Chen WANG
Chinese Medical Journal 2024;137(6):676-682
Background::Acute pulmonary embolism (APE) is a fatal cardiovascular disease, yet missed diagnosis and misdiagnosis often occur due to non-specific symptoms and signs. A simple, objective technique will help clinicians make a quick and precise diagnosis. In population studies, machine learning (ML) plays a critical role in characterizing cardiovascular risks, predicting outcomes, and identifying biomarkers. This work sought to develop an ML model for helping APE diagnosis and compare it against current clinical probability assessment models.Methods::This is a single-center retrospective study. Patients with suspected APE were continuously enrolled and randomly divided into two groups including training and testing sets. A total of 8 ML models, including random forest (RF), Na?ve Bayes, decision tree, K-nearest neighbors, logistic regression, multi-layer perceptron, support vector machine, and gradient boosting decision tree were developed based on the training set to diagnose APE. Thereafter, the model with the best diagnostic performance was selected and evaluated against the current clinical assessment strategies, including the Wells score, revised Geneva score, and Years algorithm. Eventually, the ML model was internally validated to assess the diagnostic performance using receiver operating characteristic (ROC) analysis.Results::The ML models were constructed using eight clinical features, including D-dimer, cardiac troponin T (cTNT), arterial oxygen saturation, heart rate, chest pain, lower limb pain, hemoptysis, and chronic heart failure. Among eight ML models, the RF model achieved the best performance with the highest area under the curve (AUC) (AUC = 0.774). Compared to the current clinical assessment strategies, the RF model outperformed the Wells score ( P = 0.030) and was not inferior to any other clinical probability assessment strategy. The AUC of the RF model for diagnosing APE onset in internal validation set was 0.726. Conclusions::Based on RF algorithm, a novel prediction model was finally constructed for APE diagnosis. When compared to the current clinical assessment strategies, the RF model achieved better diagnostic efficacy and accuracy. Therefore, the ML algorithm can be a useful tool in assisting with the diagnosis of APE.
5.Effects of body mass index on nocturnal hypertension in patients with hypertension: a cross-sectional study
Wenqing WANG ; Zhihua LI ; Jing XUE ; Qian CUI ; Miaomiao SHANG ; Ping YIN ; Meijuan WANG ; Li GUO ; Dongmei SONG ; Guomei XU ; Dandan SUN ; Yuchuan DAI
Chinese Journal of Modern Nursing 2024;30(8):1090-1095
Objective:To explore the effects of body mass index (BMI) on the incidence of nocturnal hypertension in patients with hypertension.Methods:Totally 341 hospitalized hypertensive patients treated at the Affiliated Hospital of Jining Medical University from February to May 2023 were selected by convenience sampling. Patients' general information, clinical data, and 24-hour ambulatory blood pressure results were collected. A binomial Logistic regression analysis was conducted to investigate the factors affecting the occurrence of nocturnal hypertension in these patients. The relationship between BMI and the incidence of nocturnal hypertension was examined using threshold effect tests and smooth curve fitting.Results:The binomial Logistic regression analysis indicated that blood phosphate level was a factor influencing the occurrence of nocturnal hypertension in hypertensive patients ( P<0.05). Smooth curve fitting and threshold effect test results showed that the relationship between BMI and the incidence of nocturnal hypertension was curve-correlated, with a turning point at 24.61 kg/m 2. To the left of the turning point, there was no correlation ( P=0.130) ; to the right, there was a correlation ( P=0.016) . Conclusions:When the BMI of hypertensive patients exceeds 24.61 kg/m 2, the likelihood of nocturnal hypertension increases with rising BMI, providing a precise intervention target for weight management-based patient care in hypertension.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
9.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
10.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.

Result Analysis
Print
Save
E-mail