1.Near-infrared fluorescence imaging for intraoperative neuroimaging:current applications and future development
Wenping GAO ; Zhihua ZHANG ; Fei HAN ; Weiguo HAO
Chinese Journal of Tissue Engineering Research 2024;28(32):5225-5230
BACKGROUND:Existing neuroimaging techniques,including magnetic resonance imaging,computed tomography,and high-resolution ultrasound,lack the capability to provide real-time intraoperative positioning images to surgeons.However,the clinical implementation of near-infrared fluorescence imaging technology has made it possible to directly visualize surgical target areas,offering a novel solution for real-time nerve identification during surgery. OBJECTIVE:To provide a summary and overview of the research progress in near-infrared fluorescence imaging technology for intraoperative neuroimaging. METHODS:The first author used the computer to search for the documents published from January 2010 to July 2023 in WanFang,CNKI,and PubMed with the key words of"near-infrared fluorescence imaging,optical imaging,nerve imaging"in Chinese and English.A few classic old documents were also included.Initial screening was performed by reading the titles and abstracts;duplicate,low-quality,and irrelevant content documents were excluded.A total of 69 articles were finally included for review. RESULTS AND CONCLUSION:Near-infrared fluorescence imaging guided by indocyanine green has been clinically used to identify and locate tubular organs such as blood vessels,ureters,and bile ducts,as well as various tumors during surgery.This technique is currently considered a well-established imaging method in precision surgery.In the field of intraoperative neurofluorescence imaging,indocyanine green is currently the only near-infrared fluorescent dye used in clinical research.The ideal neuroimaging agent should possess certain characteristics,including easy administration in the perioperative period,logD between 0.5 and 3 at pH=7.4,molecular mass below 500 Da,excitation and emission wavelengths within the near-infrared window,long-term retention in nerve tissue,high signal-to-background ratio,and high safety.In the future,the development of near-infrared neurofluorescence imaging agents should focus on synthesizing complexes of indocyanine green and neural-specific targets.This technology not only enables intraoperative neurofluorescence imaging,but also holds promising prospects for in-situ monitoring of nerve regeneration and diagnosis of neurological diseases.
2.Preliminary study on predicting hepatic artery thrombosis formation and evaluating treatment efficacy with ultrasound hemodynamic parameters in transplanted liver
Yuchen YANG ; Yuli ZHU ; Wen SHEN ; Wenping WANG ; Huixiong XU ; Hong HAN
Chinese Journal of Ultrasonography 2024;33(2):106-111
Objective:To clarify the changes of intrahepatic ultrasound hemodynamics before and after hepatic artery thrombosis (HAT) after liver transplantation (LT), providing early warning and anticoagulation guidance to clinicians.Methods:The clinical data of patients who underwent liver transplantation at Zhongshan Hospital of Fudan University between June 2006 and October 2022 were retrospectively analyzed, 47 patients with a diagnosis of HAT confirmed by DSA (digital subtraction angiography) were included in the HAT group, and 71 patients without vascular complications were included in the non-HAT group. Differences in peak flow velocity (PSV), resistance index (RI), and portal vein velocity (PVV) were compared between the two groups. Logistic regression analysis was used to determine the relationship between postoperative PSV decline and HAT occurrence, while ROC curve were used to determine the critical value and evaluate the diagnostic efficacy. Patients with HAT were divided into well-treatment group and poor-treatment group according to whether the blood flow was restored after multiple surgeries or thrombolytic treatments. The changes of early intrahepatic hemodynamics after surgical or thrombolytic therapy were compared between the two groups.Results:①A decrease in PSV of the transplanted hepatic artery was measured 1 d before HAT, and PSV<0.39 m/s predicted thrombus formation with a sensitivity of 0.70, specificity of 0.86, and the AUC was 0.83. ②After treatment, PSV in the HAT group increased immediately, approaching the normal level on the 2nd day. In the well-treatment group, PSV and PVV reached normal levels on the first day after treatment, which were significantly higher than the corresponding values in the poor-treatment group ( P=0.030, 0.021). Conclusions:In the early stage after liver transplantation, a PSV<0.39 m/s is related to the occurrence of HAT thrombosis 1 d later. A significant increase in PSV on the first day after treatment indicates a good treatment response, and there is no need for further DSA re-examination or increasing the number of thrombolysis.
3.The best evidence summary for prevention and rehabilitation nursing of pregnancy-induced diastasis recti abdominis
Min LI ; Wenping HAN ; Limin HAO ; Peishan CHAI ; Qiao SUN ; Yanxing CAO ; Jiaxin SONG
Chinese Journal of Nursing 2024;59(18):2261-2268
Objective To retrieve,evaluate and summarize the best evidence summary for prevention and nursing care of pregnancy-induced diastasis recti abdominis and to provide references for clinical practice.Methods We systematically searched computer decision support systems,guideline websites,association official websites and databases for evidence on prevention and nursing care of pregnancy-induced diastasis recti abdominis,including guidelines,expert consensuses,clinical decision-making,systematic reviews and randomized controlled trials.The retrieval period was from the inception of databases to January 2024.There were 4 researchers who evaluated the quality of the included literature independently,extracted and summarized the evidence according to the subject.Results A total of 18 articles were included,including 2 clinical decisions,4 guidelines,5 expert consensuses,3 systematic reviews,and 4 randomized controlled trials.24 pieces of best evidence were summarized from 5 aspects,including the antenatal prevention,team building,nursing assessment,intervention strategies,and effecti-veness evaluation.Conclusion This study summarizes the best evidence summary for prevention and nursing care of pregnancy-induced diastasis recti abdominis,which can provide a reference basis for nurses to manage diastasis recti abdominis and improve the life quality of maternal woman.
4.BLOC1S1 promotes proliferation of goat spermatogonial stem cells.
Shicheng WAN ; Mengfei ZHANG ; Wenbo CHEN ; Miao HAN ; Donghui YANG ; Congliang WANG ; Wenping WU ; Yuqi WANG ; Na LI ; Haijing ZHU ; Arisha AHMED HAMED ; Jinlian HUA
Chinese Journal of Biotechnology 2023;39(12):4901-4914
With the rapid development of gene editing technology, the study of spermatogonial stem cells (SSCs) holds great significance in understanding spermatogenesis and its regulatory mechanism, developing transgenic animals, gene therapy, infertility treatment and protecting rare species. Biogenesis of lysosome-related organelles complex 1 subunit 1 (BLOC1S1) is believed to have anti-brucella potential. Exploring the impack of BLOC1S1 on goat SSCs not only helps investigate the ability of BLOC1S1 to promote SSCs proliferation, but also provides a cytological basis for disease-resistant breeding research. In this study, a BLOC1S1 overexpression vector was constructed by homologous recombination. The BLOC1S1 overexpression cell line of goat spermatogonial stem cells was successfully constructed by lentivirus packaging, transfection and puromycin screening. The overexpression efficiency of BLOC1S1 was found to be 18 times higher using real time quantitative PCR (RT-qPCR). Furthermore, the results from cell growth curve analysis, flow cytometry for cell cycle detection, and 5-ethynyl-2'-deoxyuridine (EdU) staining showed that BLOC1S1 significantly increased the proliferation activity of goat SSCs. The results of RT-qPCR, immunofluorescence staining and Western blotting analyses revealed up-regulation of proliferation-related genes (PCNA, CDK2, CCND1), and EIF2S3Y, a key gene regulating the proliferation of spermatogonial stem cells. These findings strongly suggest that the proliferative ability of goat SSCs can be enhanced through the EIF2S3Y/ERK pathway. In summary, this study successfully created a goat spermatogonial stem cell BLOC1S1 overexpression cell line, which exhibited improved proliferation ability. This research laid the groundwork for exploring the regulatory role of BLOC1S1 in goat spermatogonia and provided a cell platform for further study into the biological function of BLOC1S1. These findings also establish a foundation for breeding BLOC1S1 overexpressing goats.
Animals
;
Male
;
Goats
;
Stem Cells
;
Spermatogonia/metabolism*
;
Cell Proliferation
;
Flow Cytometry
;
Testis/metabolism*
5.Learning curve in laparoscopic left lateral hepatic sectionectomy
Sijia BAI ; Ting BI ; Fengyang CHEN ; Chunhui WANG ; Lei HAN ; Yufu TANG ; Jianqiao YE ; Shaojie JIANG ; Wenping ZHOU ; Xiaodong FENG ; Wei ZHANG
Chinese Journal of Hepatobiliary Surgery 2023;29(3):170-175
Objective:To study the learning curve in laparoscopic left lateral hepatic sectionectomy.Methods:The clinical data of 62 consecutive patients who underwent left lateral hepatic sectionectomy by a single operator from February 2015 to May 2022 in General Hospital of Northern Theater Command were retrospectively analyzed. There were 22 males and 40 females, with mean ±s.d. of (50.7±11.7) years. The learning curve was depicted and evaluated by using the cumulative summation test. The general information, operation and postoperative indicators of the growth level group and the master level group were compared.Results:The average operation time of the 62 consecutive subjects was (172.9±70.1) minutes. Intraoperative blood loss was 100 (50, 200) ml. Two patients were converted to open hepatectomy. Clavien-Dindo grade I postoperative complications occurred in 20 patients (32.3%), with grade Ⅱ in 1 patient (1.6%) and grade Ⅲb in another patient (1.6%). The learning curve reached its highest point on the 20th patient by using the cumulative summation test. The study subjects were then assigned into the growth level group (patient 1-20) and the master level group (patient 21-62). The master level group had a significantly wider spread of patient age [(52.9±11.0) years vs (46.1±11.9) years], decreased operation time [(146.8±55.6) min vs (227.9±66.7) min], shortened drainage tube removal time [4(3, 5) d vs 6(4, 7) d] and decreased postoperative hospital stay [5(5, 7) d vs 6.5(4, 9) d] (all P<0.05) when compared with the growth level group. Conclusion:Left lateral hepatic sectionectomy was safe and feasible, and a single operator went through a learning curve of 20 patients before he/she could master the operation more proficiently.
6.Experimental study of shear wave dispersion imaging in evaluating inflammatory reaction zone after ablation in normal rabbit liver
Hong HAN ; Yunjie JIN ; Rong LIU ; Zhengbiao JI ; Min PU ; Wenping WANG
Chinese Journal of Ultrasonography 2021;30(5):441-445
Objective:To evaluate the value of shear wave dispersion imaging in identifying inflammatory reaction zone after liver ablation in rabbits.Methods:The animal model was made by laser ablation of rabbit liver, and then shear wave dispersion imaging and strain elastography imaging were performed on the ablation area at 3 d, 7 d, and 14 d after ablation. The shear wave dispersion values, elastic value and strain ratio measured by shear wave elastography, shear wave dispersion and strain elastography in different regions such as central necrotic tissue, surrounding inflammatory reaction zone and normal liver tissue after ablation were analyzed.Results:The shear wave dispersion values of inflammatory reaction zone around ablation site, necrotic tissue in the center of ablation site and normal liver tissue in rabbits were (26.07±4.55)m·s -1·kHz -1, (21.97±10.53)m·s -1·kHz -1and (15.45±3.94)m·s -1·kHz -1, respectively, the differences were statistically significant (all P<0.05). Compared with the three time points of 3 d, 7 d and 14 d after ablation, the shear wave dispersion value of the inflammatory zone was the highest on the 7th day after ablation ( P<0.05), while the elastic value and strain ratio in this region did not change significantly among these three time points ( P>0.05). Conclusions:Shear wave dispersion imaging can simultaneously measure tissue elasticity and viscosity, which has certain application value in identifying the inflammatory reaction zone around the ablation site in rabbit liver.
7.Feasibility of the quantitative assessment of blood perfusion in hepatocellular carcinoma by using three-dimensional contrast-enhanced ultrasound
Lijuan MAO ; Jiaying CAO ; Minjie YANG ; Cuixian LI ; Hong HAN ; Yi DONG ; Wenping WANG
Chinese Journal of Ultrasonography 2021;30(11):932-937
Objective:To investigate the clinical feasibility of three-dimensional contrast-enhanced ultrasound (3D-CEUS) in the quantitative assessment of blood perfusion of hepatocellular carcinoma (HCC).Methods:Between January 2020 and August 2021, 36 HCC patients (39 lesions in total) confirmed by pathology and clinical diagnosis without any treatment from Zhongshan Hospital, Fudan University were enrolled and underwent both 2D-CEUS and 3D-CEUS examinations. Each examination last for 150 s and all images were recorded, and then the data were analyzed. A region of interest was manually drawn along the margin of the whole tumor and then the time-intensity curve (TIC) generated. The following perfusion parameters were extracted: peak intensity (PI), peak time (TTP), ascending slope (AS), mean transit time (MTT) and area under the curve (AUC). After calculating the quality of fit (QOF) of the curve, the intraobserver agreement of the 3D-CEUS quantitative parameters obtained by the same doctor between two times were assessed, and the consistency of the 3D-CEUS and 2D-CEUS quantitative parameters was evaluated when QOF>75%. The differences of the quantitative parameters between different groups (divided by depth of 8 cm and necrosis rate of 50%, respectively) in 3D-CEUS were compared.Results:There were 38 lesions (97.4%, 38/39) with QOF>75% in 3D-CEUS. The intraobserver agreement was excellent, the intraclass correlation efficient(ICC) values was 0.85-0.99. The consistency of the time quantitative parameters (TTP and MTT) were high (the ICC values of 0.87 and 0.91), and the correlation of intensity quantitative parameters were substantial, the rs values were 0.71, 0.72 and 0.71. The differences in 3D-CEUS quantitative parameters of the two groups of lesions with different depths were statistically significant (all P<0.05); but there were no significant differences in quantitative parameters between the two groups with different necrosis rate (all P>0.05). Conclusions:Quantitative 3D-CEUS is an useful and creditable tool in evaluating the blood perfusion of HCC, especially when the depth of lesion was less than 8 cm.
8.The value of combination of micro-flow imaging and color Doppler flow imaging in the detection of vascular in hepatic tumors
Hong HAN ; Zhengbiao JI ; Hong DING ; Weibin ZHANG ; Luxia JING ; Longhui ZHANG ; Zheng ZHU ; Wenping WANG
Chinese Journal of Ultrasonography 2019;28(2):114-117
Objective To evaluate the value in the diagnosis of focal nodular hyperplasia( FNH) by combining micro-flow imaging ( MFI) and color Doppler flow imaging ( CDFI) . Methods A total of 32 patients with 32 FNH lesions were enrolled in this study . Each patient underwent CDFI ,MFI ,and contrast-enhanced ultrasonography ( CEUS ) examinations . The differences in the grade and characteristic distribution of blood flow in FNH were compared between CDFI and MFI . The results were further compared with CEUS . Results There was a significant difference between MFI and CDFI in detecting the blood flow in FNH . Twenty-six cases (81 .3% ) were detected with blood flow of grade Ⅱ and Ⅲ by MFI , however , 18 cases ( 56 .3% ) were detected of grade Ⅱ and Ⅲ by CDFI ( P = 0 .000) . A total of 12 (37 .5% ) lesions were correctly showed spoke-wheel arterial flow peculiar by CDFI ,whereas the number increased to 23(71 .9% ) in combination with MFI( P = 0 .013) . Conclusions In combination with MFI , CDFI can reveal more blood flow and detect more sensitively in FNH ,which helps to diagnose FNH . To a certain degree ,it can be applied to reduce the use of CEUS .
9.Research on gait kinematics parameters of unilateral transtibial amputees after wearing prostheses
Xidong LIU ; Zhi YAN ; Linlin HAN ; Dong LIU ; Zeliang SHAN ; Wenping WANG ; Wei FANG ; Ruisong LIAO ; Chao YU
Chinese Journal of Physical Medicine and Rehabilitation 2018;40(9):662-665
Objective To analyze the gait kinematics parameters of patients with unilateral leg amputation after wearing prosthesis using the computer assisted rehabilitation environment (CAREN) gait assessment system,and the reasons for the differences.Methods Nine patients with unilateral mid-leg amputation were selected as the prosthesis group,and 11 healthy subjects were selected as the standard group.The gait kinematics parameters of the two groups were collected,processed and analyzed by using the CAREN gait evaluation system.Results The gait phase index of the prosthetic limb group was (0.88±0.04).Significant differences were observed between the prosthetic and healthy limbs in terms of step length,stance phase percentage,maximum hip extension angle and maximum knee flexion angle,maximum dorsiflexion and plantar flexion angle of the ankle joint during the stance phase,as well as the dorsiflexion angle of ankle joint during heel strike to the ground (P<0.05).Moreover,there were significant differences between the affected limbs of the prosthetic limb group and limbs of the standard group in terms of the walking speed,gait cycle,stride length,percentage of stance phase,hip flexion angle,knee flexion and ankle dorsiflexion during heel strike,maximum hip extension and flexion angle,maximum dorsi-and plantar-flexion of ankle joint during stance phase (P<0.05).Conclusion The relative symmetry of the gait of the unilateral leg amputee is (0.88±0.04),with their kinematics parameters of the prosthetic limb significantly weaker than those of the contralateral side and the healthy controls.
10.The primary application of S-Detect technique in the diagnosis of thyroid tumors
Hong HAN ; Qing YU ; Lei ZHAO ; Longhui ZHANG ; Wenping WANG ; Chaolun LI ; Cong LI
Chinese Journal of Ultrasonography 2018;27(1):28-30
Objective To evaluate the value of S-Detect technology of ultrasonography in the diagnosis of thyroid tumors. Methods Ninety-three thyroid tumors in 93 patients were enrolled in the group.A varied image features of the thyroid masses in gray-scale ultrasonography were analyzed by S-Detect technology and experienced doctor separately.The results were compared and the diagnostic ability were also compared between the two methods. Results There were 44 malignant tumors and 49 benign tumors in these thyroid nodules.The sensitivity of S-Detect technology in the diagnosis of thyroid malignant tumors was higher,up to 88.7%. In the five image features of the thyroid tumors in gray-scale ultrasonography,the result of composition of the mass obtained by S-Detect was the most consistent with that of the doctors and Kappa value was 0.89.Conclusions S-Detect is a kind of computer-aided diagnosis system,which is suitable for the ultrasound beginners in the diagnosis of thyroid tumors.

Result Analysis
Print
Save