1.Analysis of The Characteristics of Brain Functional Activity in Gross Motor Tasks in Children With Autism Based on Functional Near-infrared Spectroscopy Technology
Wen-Hao ZONG ; Qi LIANG ; Shi-Yu YANG ; Feng-Jiao WANG ; Meng-Zhao WEI ; Hong LEI ; Gui-Jun DONG ; Ke-Feng LI
Progress in Biochemistry and Biophysics 2025;52(8):2146-2162
ObjectiveBased on functional near-infrared spectroscopy (fNIRS), we investigated the brain activity characteristics of gross motor tasks in children with autism spectrum disorder (ASD) and motor dysfunctions (MDs) to provide a theoretical basis for further understanding the mechanism of MDs in children with ASD and designing targeted intervention programs from a central perspective. MethodsAccording to the inclusion and exclusion criteria, 48 children with ASD accompanied by MDs were recruited into the ASD group and 40 children with typically developing (TD) into the TD group. The fNIRS device was used to collect the information of blood oxygen changes in the cortical motor-related brain regions during single-handed bag throwing and tiptoe walking, and the differences in brain activation and functional connectivity between the two groups of children were analyzed from the perspective of brain activation and functional connectivity. ResultsCompared to the TD group, in the object manipulative motor task (one-handed bag throwing), the ASD group showed significantly reduced activation in both left sensorimotor cortex (SMC) and right secondary visual cortex (V2) (P<0.05), whereas the right pre-motor and supplementary motor cortex (PMC&SMA) had significantly higher activation (P<0.01) and showed bilateral brain region activity; in terms of brain functional integration, there was a significant decrease in the strength of brain functional connectivity (P<0.05) and was mainly associated with dorsolateral prefrontal cortex (DLPFC) and V2. In the body stability motor task (tiptoe walking), the ASD group had significantly higher activation in motor-related brain regions such as the DLPFC, SMC, and PMC&SMA (P<0.05) and showed bilateral brain region activity; in terms of brain functional integration, the ASD group had lower strength of brain functional connectivity (P<0.05) and was mainly associated with PMC&SMA and V2. ConclusionChildren with ASD exhibit abnormal brain functional activity characteristics specific to different gross motor tasks in object manipulative and body stability, reflecting insufficient or excessive compensatory activation of local brain regions and impaired cross-regions integration, which may be a potential reason for the poorer gross motor performance of children with ASD, and meanwhile provides data support for further unraveling the mechanisms underlying the occurrence of MDs in the context of ASD and designing targeted intervention programs from a central perspective.
2.Protective value of radiation protection safety education for patients with differentiated thyroid carcinoma treated with iodine-131
Wen WANG ; Aomei ZHAO ; Hongmei LIANG ; Jie BAI ; Qi WANG ; Yiqian LIANG ; Jianjun XUE
China Occupational Medicine 2025;52(3):313-317
Objective To evaluate the protective effect of radiation protection safety education (RPSE) on patients with differentiated thyroid carcinoma (DTC) undergoing iodine-131 (131I) treatment. Methods The DTC patients who undergo 131I treatment were divided into the control group and the RPSE group using the convenience sampling method, with 142 patients in each group. Patients in the control group received routine health education, while the RPSE group received routine health education combined with RPSE. Dose equivalent rate (DER) on pillows, bed sheets, quilt covers, and household waste of patients were compared between the two groups upon discharge. Results The median (M) DERs of patients' pillows, bed sheets, quilt covers and household waste were 3.86, 3.63, 3.91 and 56.59 times higher in the control group compared with the environmental background level, respectively. The M DERs of patients' pillows, bed sheets, quilt covers were 2.23, 2.18, and 2.55 times higher in the RPSE group compared with the environmental background level, while the M DER of household waste was equivalent to the environmental background level. The DERs of patients' pillows, bed sheets, quilt covers, and household waste in the RPSE group were significantly lower than those in the control group (all P<0.001). The DERs of the above four items were lower in both male and female patients in RPSE group compared with same-gender patients in the control group (all P<0.001). The patients' DERs of the above indicators had no significant difference among different gender in both control group and RPSE group (all P>0.05), except for higher DER of household waste in female patients than that of male patients in the control group (P<0.05). There were no significant differences in the DERs of pillows, bed sheets, quilt covers, and household waste across subgroups, where patients received different treatment doses, of both the control group and the RPSE group (all P>0.05). Conclusion RPSE for DTC patients treated with 131I, reduces the DERs of pillows, bed sheets, quilt covers, and particularly household waste.
3.Contamination risk and drug resistance analysis of Klebsiella pneumoniae in a medical institution in Minghang District, Shanghai, 2021‒2023
Sijia ZHANG ; Xing ZHANG ; Liang TIAN ; Yibin ZHOU ; Xiaosa WEN ; Jing WANG ; Zhiyin XU ; Min WU
Shanghai Journal of Preventive Medicine 2025;37(4):289-295
ObjectiveTo investigate the contamination status, transmission risk and drug resistance of Klebsiella pneumoniae (KP) on the object surfaces in the surrounding environment of hospitalized patients infected with carbapenem-resistant Klebsiella pneumoniae (CRKP) , so as to provide a scientific guidance for the prevention and control of healthcare-associated infection. MethodsSamples from the surfaces of objects in the surrounding environment of CRKP infected patients living in the intensive care unit (ICU) and hand specimens from healthcare workers were collected for KP isolation and identification, as well as drug susceptible test in a medical institution located in Minhang District, Shanghai from 2021 to 2023. Additionally, both univariate and multivariate logistic regression analyses were used to identify the influencing factors associated with KP contamination in the hospital environment. ResultsA total of 546 surface samples were collected from the surrounding environment objects of 15 patients infected with CRKP, with a KP detection rate of 6.59% (36/546).The KP detection rate in the ICU of general ward (10.22%) was higher than that in the ICU of emergency department (2.94%) (χ2=12.142, P<0.001). Moreover, the KP detection rate on the surfaces of patient-contacted items (15.66%) was higher than that on shared-use items (6.25%), cleaning items (10.00%), and medical supplies (3.30%) (χ2=17.943, P<0.001). Besides, the detection rate of KP in items sent out of hospital for disinfection (15.38%) was higher than that in those self-disinfected (4.20%) (χ2=19.996, P<0.001).The highest detection rate of KP was observed in high-temperature washing (15.13%, 18/119) (χ2=21.219, P<0.001), while the lowest detection rate was observed in antibacterial hand sanitizer with trichlorohydroxydiphenyl ether sanitizing factor (0, 0/60) ( χ2=21.219, P<0.001).The detection rate of KP in samples taken more than 24 hours after the last disinfection (23.08%) was higher than that in those taken at 4 to24 hours (12.90%) and less than 4 hours (4.22%) (χ2=23.398,P<0.001).ICU of general ward (OR=4.045, 95%CI: 2.206‒7.416), patient-contacted items (OR=3.113, 95%CI: 1.191‒8.141), and self-disinfection ( OR=0.241, 95%CI:0.144‒0.402) were influencing factors for KP contamination in environmental surface. From 2021 to 2023, the drug resistance rates of hospital environmental KP isolates showed an upward trend (P<0.001) to antibiotics such as ceftazidime and gentamicin. Furthermore, high drug resistance rates of KP (>90%) were observed to ciprofloxacin, levofloxacin, cefotaxime, ceftriaxone, and cefepime. ConclusionCRKP can be transmitted outward through the surfaces of objects in the patients’ surroundings, and the drug resistance situation is severe. In clinical settings, it is necessary to implement isolation measures for CRKP infection patients, to increase the frequency of disinfection for objects in their surroundings, to strengthen hand hygiene practices, and to use antibiotics appropriately.
4.Recent advances in lamellar liquid crystal emulsification methods encapsulating natural active substances for functional cosmetics
Yi ZHANG ; Wei CHEN ; Yan-qi HAN ; Qian-wen SUN ; Yue GAO ; Jun YE ; Hong-liang WANG ; Li-li GAO ; Yu-ling LIU ; Yan-fang YANG
Acta Pharmaceutica Sinica 2024;59(2):350-358
Due to the high similarity with the lipid layer between human skin keratinocytes, functional cosmetics with layered liquid crystal structure prepared by liquid crystal emulsification technology encapsulating natural active substances have become a hot research topic in recent years. This type of functional cosmetic often has a fresh and natural skin feel, excellent skin barrier repair function and efficient moisturizing effect, etc., showing great potential in cosmetic application. However, the present research on the application of liquid crystal emulsification technology to functional cosmetics is still in the initial stage, and there are fewer relevant reports with reference values. Based on the mentioned above, this review provides a comprehensive summary of functional cosmetics with layered liquid crystal structures prepared by liquid crystal emulsification technology from the following aspects: the structure of human skin, the composition of lamellar liquid crystal, the advantages of liquid crystal emulsification technology containing natural active substances used in the field of functional cosmetics, the preparation process, main components, influencing factors during the preparation and the market functional cosmetics with lamellar liquid crystal structure. Finally, the prospect of the application of liquid crystal emulsification technology in functional cosmetics is presented, to provide useful references for those engaged in the research of liquid crystal emulsification technology-related functional cosmetics.
5.Preliminary evaluation of chin symmetry with three dimentional soft tissue spatial angle wireframe template
Liang LYU ; Mingjin ZHANG ; Aonan WEN ; Yijiao ZHAO ; Yong WANG ; Jing LI ; Gengchen YANG ; Dawei LIU
Journal of Peking University(Health Sciences) 2024;56(1):106-110
Objective:To develop an efficient and robust method based on three dimensional facial landmarks for evaluating chin region asymmetry at the soft tissue level and to compare it with the tradi-tional mirror-overlap analysis method in order to test its availability.Methods:Standard symmetrical face was used for mental tubercle coordinate transformation so as to filter soft tissue three dimensional spatial angle and construct corresponding three dimensional spatial angle wireframe template.Ten patients aged 12-32 years with clinical chin region asymmetry diagnosis at the Department of Orthodontics of Peking University Hospital of Stomatology from November 2020 to November 2021 were randomly selected.Three dimensional soft tissue face scan data of the patients were collected by three dimensional face scanner and the landmark points were automatically determined by the Meshmonk non-rigid registration algorithm pro-gram,and in this way,the asymmetric three dimensional spatial angle wireframe template and corre-sponding spatial angle parameters were generated.Mirror-overlap analysis of face scan data was also per-formed in Geomagic Studio 2015 software and deviation color maps were generated.This study took mirror-overlap analysis as the gold standard method,the response rate of chin region asymmetry was eva-luated by the outcomes of the mirror-overlap analysis and three dimensional spatial angle wireframe tem-plate analysis.Results:Nine three dimensional spatial angle indicators were selected through coordinate transformation,and the response rate was calculated using mirror-overlap analysis as the gold standard method.Among these ten selected patients,the response rate of the total chin region asymmetry was 90%(9/10).Using the deviation value of mirror-overlap analysis as a reference,the response rate of chin region asymmetry in the X dimension was 86%,the response rate of chin region asymmetry in the Y dimension was 89%,and the response rate of chin region asymmetry in the Z dimension was 100%.Conclusion:The three dimensional soft tissue spatial angle wireframe template proposed in this study has some feasibility in evaluating chin region asymmetry at the soft tissue level,and its ability to recognize asymmetry separately in the three dimensional direction is better than the mirror-overlap analysis method,and the indicators recognition rate still needs to be further improved.
6.Research progress on the mechanism of metachronous gastric cancer after endoscopic submucosal dissection and Helicobacter pylori eradication in early gastric cancer
Xin-Yue HU ; Bin WANG ; Tao WANG ; Kai-Jun LIU ; Liang-Zhi WEN ; Dong-Feng CHEN
Medical Journal of Chinese People's Liberation Army 2024;49(1):108-114
Helicobacter pylori(HP)infection is a Class Ⅰ carcinogen in gastric cancer,closely related to the occurrence of gastric cancer.Many studies have shown that HP eradication has a preventive effect on gastric cancer.However,2.7%-6.1%of patients with early gastric cancer who have been eradicated after endoscopic submucosal dissection(ESD)can still develop metachronous gastric cancer(MGC),and the mechanism of its occurrence is still unclear.In this review,the atrophy of gastric mucosa and intestinal metaplasia cannot be completely reversed after HP eradication,the excessive proliferation of gastric mucosa epithelial cells,the accumulation of genetic abnormalities,the homeostasis imbalance of the epigenetic group,changes in immune microenvironment,the abnormality of stem cells in gastric mucosa,chromatin accessibility,and changes in chromosome remodeling were discussed in the mechanism of carcinogenesis caused by the above molecular changes after ESD and HP eradication in early gastric cancer.
7.Superior vena cava syndrome and pulmonary artery stenosis in a patient with lung metastases of bladder cancer
Jian-Ke LI ; Ya-Nan GU ; Jun-Hao LI ; Liang-Wen WANG ; Ning-Zi TIAN ; Wei CHEN ; Xiao-Lin WANG ; Yi CHEN
Fudan University Journal of Medical Sciences 2024;51(2):277-279,284
Superior vena cava syndrome(SVCS)is a group of clinical syndromes caused by obstruction of the superior vena cava and its major branches from various causes.Pulmonary artery stenosis(PS)is a complication of lung cancer or mediastinal tumours.SVCS combined with PS due to pulmonary metastases from bladder cancer is extremely rare and has not been reported in the literature.Here we reported an old male patient with pulmonary metastases from bladder cancer presenting with swelling of the head,neck and both upper limbs.SVCS combined with PS was clarified by pulmonary artery computed tomography angiography(CTA)and digital subtraction angiography(DSA).Endovascular stenting was used to treat SVCS.Angiography also showed that PS had not caused pulmonary hypertension and did not need to be treated.The swelling of the patient's head,neck and upper limbs was gradually reduced after the procedure.
8.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
9.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
10.Ethylene oxide residue detection method based on multi-component medical devices
Ruo-Jin LIU ; Zi-Meng WANG ; Hui LI ; Wen-Liang SHAO ; Bao-Yu LIU ; Yi FENG
Chinese Medical Equipment Journal 2024;45(1):56-61
Objective To establish a stable and reliable method for the determination of ethylene oxide residue,and to analyze ethylene oxide residue in multi components made of different materials involved in some medical devices,so as to provide references for sample selection and ethylene oxide residue detection of multi-component medical device kits.Methods A method for the determination of ethylene oxide residue of multi-component medical devices was developed using headspace-gas chromatography and DB-WAX column under the conditions of headspace extraction with equilibration at 80℃ for 20 min,and the weighing mass,linearity,limit of detection,limit of quantification,precision and recovery of the method were determined.Trials of the method were carried out on the items undergoing ethylene oxide sterilization,including disposable perineal care kit,disposable gynecological examination kit,disposable suture dressing kit,disposable debridement kit and the components contacting human body in the disposable dialysis kit,and the abilities of different materials of the components were analyzed in absorbing,retaining and releasing ethylene oxide.Results The method showed high linearity(r=0.999 8)in the range of ethylene oxide mass concentration from 0.4 to 16.0 μg/mL with a weighing mass of 1.00 g,which had the limit of detection being 0.11 μg/mL,the limit of quantification being 0.37 μg/mL and the relative standard deviations(RSDs)for the precision from 0.35%to 1.52%.The average recoveries of different spiked amounts of ethylene oxide in the three blank matrices ranged from 92.68%to 101.42%with the relative standard deviations(RSDs)from 2.46%to 7.59%,which all satisfied the detection requirements.The components made of rubber and acrylonitrile-butadiene-styrene copolymer(ABS)in multi-component medical device kits had the highest ethylene oxide residues,followed by the components made of wood,degreased cotton,polypropylene and polystyrene.Conclusion The method proposed gains advantages in easy operation and high specificity,quantification and reproducibility,which can be used for the determination of ethylene oxide residue in the multi-component medical device kit undergoing ethylene oxide sterilization.References are provided for sample selection of multi-component medical devices.[Chinese Medical Equipment Journal,2024,45(1):56-61]

Result Analysis
Print
Save
E-mail