1.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
2.Application of single-sperm sequencing in resolving the carrier status of preimplantation genetic testing for chromosomal structural rearrangements in Robertsonian translocations
Bao-Qiong LIAO ; Li-Dan LAI ; Ru-Tian LIU ; Qi ZHANG ; Wen-Chang LIAN ; Wu-Ming XIE
National Journal of Andrology 2024;30(6):499-506
Objective:To investigate the application value of single-sperm sequencing in resolving the carrier status of preim-plantation genetic testing(PGT)for chromosomal structural rearrangements in Robertsonian translocations.Methods:Haplotypes were constructed by single-sperm isolation combined with single-sperm sequencing for a patient with 45,XY,der(13;14)(q10;q10).Twenty single-sperm samples were isolated by mechanical braking and subjected to whole-genome amplification(WGA),and then the Asian Screening Array(ASA)gene chip was used to detect the 183 708 single nucleotide polymorphisms(SNP)of the WGA products.The single sperm associated with the translocation that could be used as haplotype inference was detected by copy number variation(CNV)sequencing,and the chromosomal haplotypes with normal and Robertsonian translocations were inferred.Three biopsy samples of embryonic trophoblast cells were used as the objects.After whole-genome amplification,high-throughput sequencing was employed to determine the status of the translocation chromosome carried by the embryos.The available blastocysts were selected for transfer,and the amniotic fluid samples were taken at 18 weeks of gestation to confirm whether the fetus carried the pathogenic muta-tion.Results:A total of 6 037 SNP sites were screened by single-sperm sequencing,and 30 sites selected to distinguish normal and translocation haplotypes.Preimplantation haplotype analysis showed that all the three embryos were euploids without Robertsonian translocation chromosome.Genetic testing of amniotic fluid in the second trimester confirmed that the karyotype of the fetus was 46,XN,carrying no Robertsonian translocation chromosome.Conclusion:For male carriers of Robertsonian translocation,single sperm sequencing can be used to screen SNP sites to construct haplotypes for distinguishing normal and Robertsonian translocation em-bryos,and to provide a basis for embryo selection by preimplantation chromosomal structural genetic testing.
3.Failures and successes learned from 160 years of echinococcosis control and countermeasures in China
Chuan-Chuan WU ; Zhuang-Zhi ZHANG ; Jun LI ; Wen-Jing QI ; Jian-Ping CAO ; Can-Jun ZHENG ; Wen-Bao ZHANG
Chinese Journal of Zoonoses 2024;40(5):464-470
The transmission cycle of echinococcosis was established in 1853.More than 160 years have elapsed since Iceland initiated control measures to break the transmission cycle of echinococcosis in 1863.Control plans have been implemented in more than a dozen countries/territories,and lessons have been learned from failures as well as successes.In this review,we fo-cus on the failure experiences,which have also promoted successes in the control of cystic echinococcosis(caused by the para-site Echinococcus granulosus)in regions including Iceland,New Zealand,Uruguay,Wales(England),Turkana(Kenya),and Sardinia(Italy).The causes of the failures were analyzed,and the effects of health education,dog deworming,and con-trol measures for infected animal slaughter on echinococcosis control are comprehensively summarized.However,no suc-cessful experience has been reported in the control of alveolar echinococcosis(caused by the parasite Echinococcus multilocu-laris).On the basis of the biological characteristics of E.mul-tilocularis parasitization in dogs for a duration of 30 days and larvae parasitization in rodents,the fundamental measure for controlling alveolar echinococcosis is administration of monthly deworming treatments to dogs in high prevalence areas.
4.Expression of CRKL in intrahepatic cholangiocarcinoma and its effect on the proliferation and invasion of cholangiocarci-noma cells
Wen-Lei KUO ; Xin-Yue BAO ; Jing-Bo CHANG ; Qi SUN ; Li-Min WEI
Chinese Journal of Current Advances in General Surgery 2024;27(9):684-688
Objective:To investigate the expression of kinase-like gene CT10 regulatory fac-tor(CRKL)in intrahepatic cholangiocarcinoma(ICC)and its effect on the proliferation and invasion of intrahepatic cholangiocarcinoma cells.Methods:qRT-PCR detected CRKL transcription in ICC pa-tient tissues and adjacent tissues.Immunohistochemistry assessed CRKL expression in ICC tissues and adjacent tissues,and analyzed its relationship with clinicopathological features.For the inhibition of CRKL expression in QBC939 cells by siRNA technology,the effect of CRKL silencing on AKT and ERK signaling pathway was measured by Western blot.CRKL's influence on QBC939 cell prolifera-tion and invasion was analyzed by MTT,clonogenesis,and Transwell assays.Results:The expres-sion of CRKL in ICC tissues was up-regulated,and there were statistically significant differences in CRKL expression in ICC with different clinicopathological features such as tumor size,lymph node metastasis and TNM stage.Cellular experiments showed a significant decrease in the phosphoryla-tion of AKT and ERK upon inhibition of CRKL,and the proliferation and invasion ability of ICC cells was significantly diminished(P<0.05).Conclusion:CRKL promotes ICC cell proliferation and invasion through AKT and ERK pathways,offering new molecular targets and directions for targeted therapy.
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
9.Mechanism of bilobalide promoting neuroprotection of macrophages.
Yang-Yang CHEN ; Wen-Yuan JU ; Guo-Guo CHU ; Xiao-Hui LI ; Ru-Heng WEI ; Qing WANG ; Bao-Guo XIAO ; Cun-Gen MA
China Journal of Chinese Materia Medica 2023;48(15):4201-4207
This study aims to explore the neuroprotective effect of bilobalide(BB) and the mechanisms such as inhibiting inflammatory response in macrophage/microglia, promoting neurotrophic factor secretion, and interfering with the activation and differentiation of peripheral CD4~+ T cells. BB of different concentration(12.5, 25, 50, 100 μg·mL~(-1)) was used to treat the RAW264.7 and BV2 cells for 24 h. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT) assay and cell counting kit-8(CCK-8) were employed to detect the cytotoxicity of BB and appropriate concentration was selected for further experiment. Lipopolysaccharide(LPS) was applied to elicit inflammation in RAW264.7 and BV2 cells, mouse bone marrow-derived macrophages(BMDMs), and primary microglia, respectively. The effect of BB on cell proliferation and secretion of inflammatory cytokines and neurotrophic factors was detected by enzyme-linked immunosorbent assay(ELISA). Spleen monocytes of C57BL/6 female mice(7-8 weeks old) were isolated, and CD4~+ T cells were separated by magnetic beads under sterile conditions. Th17 cells were induced by CD3/CD28 and the conditioned medium for eliciting the inflammation in BMDMs. The content of IL-17 cytokines in the supernatant was detected by ELISA to determine the effect on the activation and differentiation of CD4~+ T cells. In addition, PC12 cells were incubated with the conditioned medium for eliciting inflammation in BMDMs and primary microglia and the count and morphology of cells were observed. The cytoto-xicity was determined by lactate dehydrogenase(LDH) assay. The result showed that BB with the concentration of 12.5-100 μg·mL~(-1) had no toxicity to RAW264.7 and BV2 cells, and had no significant effect on the activity of cell model with low inflammation. The 50 μg·mL~(-1) BB was selected for further experiment, and the results indicated that BB inhibited LPS-induced secretion of inflammatory cytokines. The experiment on CD4~+ T cells showed that the conditioned medium for LPS-induced inflammation in BMDMs promoted the activation and differentiation of CD4~+ T cells, while the conditioned medium of the experimental group with BB intervention reduced the activation and differentiation of CD4~+ T cells. In addition, BB also enhanced the release of neurotrophic factors from BMDMs and primary microglia. The conditioned medium after BB intervention can significantly reduce the death of PC12 neurons, inhibit neuronal damage, and protect neurons. To sum up, BB plays a neuroprotective role by inhibiting macrophage and microglia-mediated inflammatory response and promoting neurotrophic factors.
Female
;
Rats
;
Mice
;
Animals
;
Bilobalides/pharmacology*
;
Neuroprotection
;
Lipopolysaccharides/toxicity*
;
Culture Media, Conditioned/pharmacology*
;
Mice, Inbred C57BL
;
Macrophages/metabolism*
;
Microglia
;
Cytokines/metabolism*
;
Nerve Growth Factors/pharmacology*
;
Inflammation/metabolism*
10. Procyanidin B2 protects H
Yi-Wei DONG ; Zhi-Chao YANG ; Wei-Jia JIANG ; Jian-Chun LIU ; Wan-Fang YANG ; Shu-Wen YUAN ; Xiao-Hui LI ; Cun-Gen MA ; Qing WANG ; Bao-Guo XIAO
Chinese Pharmacological Bulletin 2023;39(9):1654-1661
Aim To explore the protective effect of proanthocyanidin B2 (PC-B2) on oxidative damage of PC 12 cells induced by hydrogen peroxide (H

Result Analysis
Print
Save
E-mail