1.Textual Research and Analysis of Historic Origin and Ancient and Modern Application of Classic Formula Shengjiangsan
Lyuyuan LIANG ; Jialei CAO ; Xinghang LYU ; Weixiao LI ; Wenxi WEI ; Bingqi WEI ; Zhe WANG ; Yiping WANG ; Bingxiang MA ; Wenli SHI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):219-227
Shengjiangsan is a classic formula for treating warm diseases with wide clinical application and accurate efficacy. There are different opinions on the origin of this formula and lacks key information research on this formula. Therefore, in this study, we conducted systematic research into the historic origin, composition, and other key information of this Shengjiangsan. Results showed that Shengjiangsan has different versions, with "Neixian Fufang", "Jiawei Jianghuangwan", "Peizhensan", and "Taijiwan" being the same formula with different names. Shengjiangsan was first recorded as "Neixian Fufang" in Wanbing Huichun written by GONG Tingxian from the Ming dynasty, inherited and developed by YANG Lishan from Qing dynasty, and has been passed down to modern times. Pills and powder are two main forms of Shengjiangsan, and powder has become more popular nowadays. According to the measurement system of Ming and Qing dynasties, the recommended dosage and usage of Shengjiangsan are as follows. For the pill version of Shengjiangsan, Bombyx Batryticatus of 74.6 g, Curcumae Longae Rhizoma of 9.325 g, Cicadae Periostracum of 9.325 g, and Rhei Radix et Rhizoma of 149.2 g were processed into pills for preparation. Single dosage is Bombyx Batryticatus of 1.15 g, Curcumae Longae Rhizoma of 0.14 g, Cicadae Periostracum of 0.14 g, and Rhei Radix et Rhizoma of 2.3 g, with halved dosage applied for children. For the powder version of Shengjiangsan, the dosage varied in accordance with the severity of the disease. Bombyx Batryticatus of 1.84 g, Curcumae Longae Rhizoma of 0.28 g, Cicadae Periostracum of 0.92 g, and Rhei Radix et Rhizoma of 3.68 g were processed into powder for patients with mild symptoms. Bombyx Batryticatus of 2.48 g, Curcumae Longae Rhizoma of 0.37 g, Cicadae Periostracum of 1.23 g, and Rhei Radix et Rhizoma of 4.91 g were processed into powder for patients with severe symptoms. Bombyx Batryticatus of 3.68 g, Curcumae Longae Rhizoma of 1.84 g, Cicadae Periostracum of 0.55 g, and Rhei Radix et Rhizoma of 7.36 g were processed into powder for patients with critical conditions. In this formula, four herbs were ground to fine powder. For patients with mild symptoms, the whole formula was divided into four dosages, and each dosage weighed 6.71 g. The 200 mL yellow rice wine and 18.65 g honey were added, and the solution was stirred and taken cold till full recovery. For patients with severe symptoms, the whole formula was divided into three dosages, and each weighed 8.95 g. 300 mL yellow rice wine and 27.98 g honey were added, and the solution was stirred and taken cold. For patients with critical conditions, the whole formula was divided into two dosages, and each weighed 13.43 g. 400 mL yellow rice wine and 37.3 g honey were added, and the solution was stirred and taken cold. Shengjiangsan has the effect of ascending lucidity and descending turbidity, dissipating wind, and clearing heat. It is specialized in treating severe heat in exterior, interior, and triple energizers in warm diseases and has a wide modern clinical application. In this study, the historic evolution and key information of Shengjiangsan were reviewed and analyzed, and the key information table of Shengjiangsan was attached, serving as a reference for scholars' research and a theoretical basis for its market transformation.
2.Analysis of Ancient and Modern Literature of Xiaoyaosan and Examination of Its Key Information
Zhe WANG ; Jialei CAO ; Lyuyuan LIANG ; Yiping WANG ; Chen CHEN ; Weixiao LI ; Bingqi WEI ; Yinli LI ; Yongbin YAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(15):227-237
First recorded in an official medical book from the Northern Song Dynasty called Taiping Huimin Heji Ju Fang (Prescriptions of the Bureau of Taiping People's Welfare Pharmacy), Xiaoyaosan has been developed and refined over generations and is preserved to this day. It specializes in soothing the liver,resolving stagnation,fortifying the spleen,and nourishing blood. In this study,ancient traditional Chinese medicine (TCM) books and contemporary studies were reviewed to obtain information on Xiaoyaosan using bibliometrics,including its historical development,dosage,origin,processing methods,decoction dosage,and ancient and modern indications. Furthermore,a question regarding the presence of Zingiberis Rhizoma Recens and Menthae Haplocalycis Herba in Xiaoyaosan was investigated,and a table of key information on Xiaoyaosan was compiled,providing references for developing Xiaoyaosan preparations. According to the weight and measurement system of the Song dynasty,the contemporary equivalent formulation of the decocted Xiaoyaosan consists of 20.65 g of Glycyrrhizae Radix et Rhizoma and 41.3 g of Angelica Sinensis Radix,Poria,Paeoniae Radix Alba,Atractylodis Macrocephalae Rhizoma,and Bupleuri Radix. The formulation is processed to obtain a mixed powder with a particle size of 10 mesh. For each dose,8.25 g of the mixed powder is combined with 1 g of unprocessed Zingiberis Rhizoma Recens and 0.62 g of Menthae Haplocalycis Herba in 300 mL of water. The mixture is decocted until the volume reaches 210 mL,and the residue is then removed,with no specific timing required for administration. After the processing,each dose consists of approximately 0.75 g of Glycyrrhizae Radix et Rhizoma and 1.50 g of Radix Angelica Sinensis,Poria,Paeoniae Radix Alba,Atractylodis Macrocephalae Rhizoma,and Bupleuri Radix. Ancient medical literature shows that Xiaoyaosan primarily treats blood deficiency and overstrain,specifically for symptoms including heat caused by blood deficiency and fatigue,irregular menstruation,headache,eye soreness,pain in the ribs and limbs,and emaciation and bone steaming. In the Qing Dynasty,ZHANG Lu clearly proposed the pathogenesis of liver depression,and since then,the use of Xiaoyaosan in treating various syndromes associated with liver depression has been highly praised by physicians in the Qing dynasty and modern times. Xiaoyaosan has a wide application in modern clinical practices,involving digestive diseases,gynecological diseases,psychological diseases,nervous system diseases,and otorhinolaryngologic diseases. Moreover,it is most commonly used to treat depression and other diseases complicated with depression,hyperplasia of the mammary gland,etc. The key information on Xiaoyaosan and its clinical applications in ancient and modern times investigated in the study could serve as a scientific reference for in-depth research and extended clinical applications of the prescription.
3.Expert Consensus on Clinical Diseases Responding Specifically to Traditional Chinese Medicine: Threatened Abortion
Xinchun YANG ; Shuyu WANG ; Huilan DU ; Songping LUO ; Zhe JIN ; Rong LI ; Xiangyan RUAN ; Qin ZHANG ; Xiaoling FENG ; Shicai CHEN ; Fengjie HE ; Shaobin WEI ; Qun LU ; Yanqin WANG ; Yang LIU ; Qingwei MENG ; Zengping HAO ; Ying LI ; Mei MO ; Xiaoxiao ZHANG ; Ruihua ZHAO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):241-246
Threatened abortion is a common disease of obstetrics and gynecology and one of the diseases responding specifically to traditional Chinese medicine (TCM). The China Association of Chinese Medicine organized experts in TCM obstetrics and gynecology, Western medicine obstetrics and gynecology, and pharmacology to deeply discuss the advantages of TCM and integrated Chinese and Western medicine treatment as well as the medication plans for threatened abortion. After discussion, the experts concluded that chromosome, endocrine, and immune abnormalities were the key factors for the occurrence of threatened abortion, and the Qi and blood disorders in thoroughfare and conception vessels were the core pathogenesis. In the treatment of threatened abortion, TCM has advantages in preventing miscarriages, alleviating clinical symptoms and TCM syndromes, relieving anxiety, regulating reproductive endocrine and immune abnormalities, personalized and diversified treatment, enhancing efficiency and reducing toxicity, and preventing the disease before occurrence. The difficulty in diagnosis and treatment of threatened abortion with traditional Chinese and Western medicine lies in identifying the predictors of abortion caused by maternal factors and the treatment of thrombophilia. Recurrent abortion is the breakthrough point of treatment with integrated traditional Chinese and Western medicine. It is urgent to carry out high-quality evidence-based medicine research in the future to improve the modern diagnosis and treatment of threatened abortion with TCM.
4.Analysis of ocular biometric parameters in Tibetan patients with age-related cataract
Huali ZHU ; Tingting XU ; Ling WEI ; Zhe XU ; Jie LI ; Pei LIU ; Sicen LIU ; Haomei WANG
International Eye Science 2024;24(5):816-820
AIM:To compare the differences of ocular biometric parameters of age-related cataract between Tibetan and Han ethnic groups, and to analyze the distribution characteristics of ocular biometric parameters in Tibetan cataract patients.METHODS:Retrospective cohort study. A total of 661 patients(1 030 eyes)with age-related cataract confirmed in the hospital between January 2019 and December 2020 were enrolled. The parameters of axial length, anterior chamber depth, keratometry, corneal astigmatism and astigmatic axis were measured by IOL Master 500 in 483 cases(739 eyes)of Tibetan age-related cataract patients and 178 cases(291 eyes)of Han patients.RESULTS:The axial length, anterior chamber depth and corneal astigmatism of the Tibetan patients with age-related cataract were 23.33(22.81, 23.86)mm, 3.04(2.79, 3.30)mm and 0.73(0.47, 1.07)D. The mean keratometry was 43.89±1.35 D. The results indicated that Tibetan cataract patients had shorter axial lengths and smaller keratometry compared to Han patients(all P<0.05). Age in Tibetan patients was negatively correlated with axial length and anterior chamber depth, and positively correlated with keratometry(all P<0.05). Tibetan male patients had longer axial lengths, deeper anterior chambers, and flatter corneas compared to female patients(all P<0.05).CONCLUSION:There were differences in ocular biometric parameters between age-related cataract patients of Tibetan and Han ethnicities. The distribution of ocular biometric parameters in Tibetan cataract patients varied across different age groups and gender groups.
5.Research on the differential diagnosis of phlegm and blood stasis pattern and qi deficiency and blood stasis pattern in stable angina pectoris based on coronary artery CT angiography radiomics
Dongsheng WEI ; Jiajie QI ; Xiaosheng LIU ; Luzhen LI ; Han LI ; Yuting LIU ; Chengkang DENG ; Xu DAI ; Baoying ZHAO ; Zhe ZHANG
Journal of Beijing University of Traditional Chinese Medicine 2024;47(4):545-554
Objective To establish a differential model of phlegm and blood stasis pattern and qi deficiency and blood stasis pattern in stable angina pectoris using radiomics.Methods A total of 91 patients with stable angina pectoris who underwent coronary artery CT angiography in Affiliated Hospital of Liaoning University of Traditional Chinese Medicine from January 2021 to January 2022 were collected,including 47 cases of phlegm and blood stasis pattern and 44 cases of qi deficiency and blood stasis pattern.The patients were divided into train set(64 cases)and test set(27 cases)according to the ratio of 7∶3 by stratified random sampling method.3D-slicer software was used to extract the radiomics features of pericoronary adipose tissue(PCAT)images.Principal component analysis was used to visualize the distribution of radiomics features of pattern of phlegm and blood stasis and pattern of qi deficiency and blood stasis.The least absolute shrinkage and selection operator regression analysis and support vector machine decreasing feature elimination were used for feature selection.The multinomial logistics regression was used for model construction.The receiver operating characteristic(ROC)curve was used to verify the model in the train set and the test set to evaluate the effectiveness of the radiomics features in differentiating phlegm and blood stasis pattern and qi deficiency and blood stasis pattern.Finally,Spearman coefficient was used to analyze the correlation between the differential features and clinical physicochemical data.Results A total of 837 radiomics features were extracted from PCAT images by 3D-slicer software.In the principal component analysis,PC1 and PC2 explained 77.9%and 8.1%of the total variance,respectively,and there was a relatively obvious separation trend between the two pattern groups.After feature screening,7 radiomics features were used to construct the differential model of phlegm and blood stasis pattern and qi deficiency and blood stasis pattern.The area under the ROC curve(AUC)of the differential model was 0.844 in the train set and 0.834 in the test set.Spearman correlation analysis showed that the differential features were significantly correlated with cTnI,neutrophil,triglyceride,total cholesterol,and leukocyte.Conclusion The CT radiomics model based on PCAT has a high discrimination efficiency for stable angina pectoris with phlegm and blood stasis pattern and qi deficiency and blood stasis pattern.
6.Raman Spectroscopy Analysis of The Temporal Heterogeneity in Lung Cell Carcinogenesis Induced by Benzo(a)pyrene
Hai-Tao ZHOU ; Wei YAO ; Cao-Zhe CUI ; Xiao-Tong ZHOU ; Xi-Long LIANG ; Cheng-Bing QIN ; Lian-Tuan XIAO ; Zhi-Fang WU ; Si-Jin LI
Progress in Biochemistry and Biophysics 2024;51(6):1458-1470
ObjectiveTemporal heterogeneity in lung cancer presents as fluctuations in the biological characteristics, genomic mutations, proliferation rates, and chemotherapeutic responses of tumor cells over time, posing a significant barrier to effective treatment. The complexity of this temporal variance, coupled with the spatial diversity of lung cancer, presents formidable challenges for research. This article will pave the way for new avenues in lung cancer research, aiding in a deeper understanding of the temporal heterogeneity of lung cancer, thereby enhancing the cure rate for lung cancer. MethodsRaman spectroscopy emerges as a powerful tool for real-time surveillance of biomolecular composition changes in lung cancer at the cellular scale, thus shedding light on the disease’s temporal heterogeneity. In our investigation, we harnessed Raman spectroscopic microscopy alongside multivariate statistical analysis to scrutinize the biomolecular alterations in human lung epithelial cells across various timeframes after benzo(a)pyrene exposure. ResultsOur findings indicated a temporal reduction in nucleic acids, lipids, proteins, and carotenoids, coinciding with a rise in glucose concentration. These patterns suggest that benzo(a)pyrene induces structural damage to the genetic material, accelerates lipid peroxidation, disrupts protein metabolism, curtails carotenoid production, and alters glucose metabolic pathways. Employing Raman spectroscopy enabled us to monitor the biomolecular dynamics within lung cancer cells in a real-time, non-invasive, and non-destructive manner, facilitating the elucidation of pivotal molecular features. ConclusionThis research enhances the comprehension of lung cancer progression and supports the development of personalized therapeutic approaches, which may improve the clinical outcomes for patients.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail