1.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
6.Diagnostic and predictive value of CT perfusion imaging in patient with traumatic brain injury
Anming XIE ; Liuxian WANG ; Wenfeng WEI ; Jing ZHA ; Huagang FAN ; Ming LIAO
Journal of Practical Radiology 2024;40(3):356-360
		                        		
		                        			
		                        			Objective To investigate the application value of CT perfusion imaging in patient with traumatic brain injury(TBI).Methods Thirty-seven patients with TBI were included retrospectively and divided into mild,moderate,and severe groups according to Glasgow coma scale(GCS)score.Perfusion parameters of the cerebral hemispheres on the injured side and the contralateral side of the level of basal ganglia were compared.After three months,the correlations between perfusion parameters and GCS score at baseline and Glasgow outcome scale-extended(GOSE)score at follow-up were further analyzed,respectively.Results The injured side of TBI patients showed hypo-perfusion compared with that of the contralateral side.The abnormal perfusion volumes of time to maximum of the residual function(Tmax)>10 s was significantly negatively correlated with GOSE score(ρ=-0.55,P=0.01),and could distinguish the good prognosis group from the poor prognosis group with GOSE score[area under the curve(AUC)=0.82,P= 0.01].In the group of patients undergoing decompressive craniectomy,the abnormal perfusion volumes of Tmax>4 s and Tmax>6 s were significantly associated with GCS score(ρ=0.61,P=0.01;ρ=0.53,P=0.03).Conclusion CT perfusion imaging may be useful in assessing the hemodynamics and severity of TBI,and in predicting the clinical prognosis.
		                        		
		                        		
		                        		
		                        	
7.Application of brain-computer interface technology based on electroencephalogram in upper limb motor function rehabilitation of stroke patients
Ming ZHANG ; Bin WANG ; Fan JIA ; Jie CHEN ; Wei TANG
Chinese Journal of Tissue Engineering Research 2024;28(4):581-586
		                        		
		                        			
		                        			BACKGROUND:Current rehabilitation programs are effective in treating post-stroke sequelae,but the treatment cycle is long and the labor cost is high.Brain-computer interface technology can be used for the treatment of post-stroke patients by extracting signals from the brain's neural activity through special equipment and converting this signal into commands that can be recognized by a computer. OBJECTIVE:To analyze and summarize the application of brain-computer interface technology in the upper limb motor function rehabilitation of stroke patients in recent years and to explore the clinical value of brain-computer interface technology in the upper limb function rehabilitation of stroke patients. METHODS:CNKI and PubMed were retrieved for relevant literature published from 2000 to 2022.The keywords were"stroke,electroencephalogram,brain-computer interface,upper limb,virtual reality technology,functional electrical stimulation,exoskeleton"in Chinese and"stroke,brain-computer interface,computer assistance,upper limb,virtual reality technology,functional electrical stimulation,exoskeleton"in English. RESULTS AND CONCLUSION:The brain-computer interface has shown promise for the restoration of upper limb motor function in stroke patients and has been shown to produce results that are unattainable with conventional treatments,and is well worth further research and promotion,but the mechanisms have not been fully elucidated.Also the ability to accurately decode all degrees of freedom of upper limb movements to provide flexible and natural control remains a challenge from the perspective of brain-computer interface systems that capture electroencephalogram signals from patients.Future research should focus on clarifying the specific neural mechanisms by which brain-computer interface technology facilitates upper limb motor recovery after stroke and identifying rehabilitation options such as brain-computer interfaces combined with external devices to facilitate upper limb motor function recovery in stroke patients.
		                        		
		                        		
		                        		
		                        	
8.Longitudinal extrauterine growth restriction in extremely preterm infants: current status and prediction model
Xiaofang HUANG ; Qi FENG ; Shuaijun LI ; Xiuying TIAN ; Yong JI ; Ying ZHOU ; Bo TIAN ; Yuemei LI ; Wei GUO ; Shufen ZHAI ; Haiying HE ; Xia LIU ; Rongxiu ZHENG ; Shasha FAN ; Li MA ; Hongyun WANG ; Xiaoying WANG ; Shanyamei HUANG ; Jinyu LI ; Hua XIE ; Xiaoxiang LI ; Pingping ZHANG ; Hua MEI ; Yanju HU ; Ming YANG ; Lu CHEN ; Yajing LI ; Xiaohong GU ; Shengshun QUE ; Xiaoxian YAN ; Haijuan WANG ; Lixia SUN ; Liang ZHANG ; Jiuye GUO
Chinese Journal of Neonatology 2024;39(3):136-144
		                        		
		                        			
		                        			Objective:To study the current status of longitudinal extrauterine growth restriction (EUGR) in extremely preterm infants (EPIs) and to develop a prediction model based on clinical data from multiple NICUs.Methods:From January 2017 to December 2018, EPIs admitted to 32 NICUs in North China were retrospectively studied. Their general conditions, nutritional support, complications during hospitalization and weight changes were reviewed. Weight loss between birth and discharge > 1SD was defined as longitudinal EUGR. The EPIs were assigned into longitudinal EUGR group and non-EUGR group and their nutritional support and weight changes were compared. The EPIs were randomly assigned into the training dataset and the validation dataset with a ratio of 7∶3. Univariate Cox regression analysis and multiple regression analysis were used in the training dataset to select the independent predictive factors. The best-fitting Nomogram model predicting longitudinal EUGR was established based on Akaike Information Criterion. The model was evaluated for discrimination efficacy, calibration and clinical decision curve analysis.Results:A total of 436 EPIs were included in this study, with a mean gestational age of (26.9±0.9) weeks and a birth weight of (989±171) g. The incidence of longitudinal EUGR was 82.3%(359/436). Seven variables (birth weight Z-score, weight loss, weight growth velocity, the proportion of breast milk ≥75% within 3 d before discharge, invasive mechanical ventilation ≥7 d, maternal antenatal corticosteroids use and bronchopulmonary dysplasia) were selected to establish the prediction model. The area under the receiver operating characteristic curve of the training dataset and the validation dataset were 0.870 (95% CI 0.820-0.920) and 0.879 (95% CI 0.815-0.942), suggesting good discrimination efficacy. The calibration curve indicated a good fit of the model ( P>0.05). The decision curve analysis showed positive net benefits at all thresholds. Conclusions:Currently, EPIs have a high incidence of longitudinal EUGR. The prediction model is helpful for early identification and intervention for EPIs with higher risks of longitudinal EUGR. It is necessary to expand the sample size and conduct prospective studies to optimize and validate the prediction model in the future.
		                        		
		                        		
		                        		
		                        	
9.A Biomechanical Comparison of 2 Different Topping-off Devices and Their Influence on the Sacroiliac Joint Following Lumbosacral Fusion Surgery
Wei FAN ; Song YANG ; Jie CHEN ; Li-Xin GUO ; Ming ZHANG
Neurospine 2024;21(1):244-252
		                        		
		                        			 Objective:
		                        			Interspinous spacer (ISS)-based and pedicle screw-rod dynamic fixator (PDF)-based topping-off devices have been applied in lumbar/lumbosacral fusion surgeries for preventing the development of proximal adjacent segment degeneration. However, little attention has been paid to sacroiliac joint (SIJ), which belongs to the adjacent joints. Accordingly, the objective of this study was to compare how these 2 topping-off devices affect the SIJ biomechanics. 
		                        		
		                        			Methods:
		                        			A validated, normal finite-element lumbopelvic model (L3–pelvis) was initially adjusted to simulate interbody fusion with rigid fixation at the L5–S1 level, and then the DIAM or BioFlex system was instrumented at the L4–5 level to establish the ISS-based or PDF-based topping-off model, respectively. All the developed models were loaded with moments of 4 physiological motions using hybrid loading protocol. 
		                        		
		                        			Results:
		                        			Compared with the rigid fusion model (without topping-off devices), range of motion and von-Mises stress at the SIJs were increased by 23.1%–64.1% and 23.6%–62.8%, respectively, for the ISS-based model and by 51.2%–126.7% and 50.4%–108.7%, respectively, for the PDF-based model. 
		                        		
		                        			Conclusion
		                        			The obtained results suggest that the PDF-based topping-off device leads to higher increments in SIJ motion and stress than ISS-based topping-off device following lumbosacral fusion, implying topping-off technique could be linked to an increased risk of SIJ degeneration, especially when using PDF-based device. 
		                        		
		                        		
		                        		
		                        	
10.A Biomechanical Comparison of 2 Different Topping-off Devices and Their Influence on the Sacroiliac Joint Following Lumbosacral Fusion Surgery
Wei FAN ; Song YANG ; Jie CHEN ; Li-Xin GUO ; Ming ZHANG
Neurospine 2024;21(1):244-252
		                        		
		                        			 Objective:
		                        			Interspinous spacer (ISS)-based and pedicle screw-rod dynamic fixator (PDF)-based topping-off devices have been applied in lumbar/lumbosacral fusion surgeries for preventing the development of proximal adjacent segment degeneration. However, little attention has been paid to sacroiliac joint (SIJ), which belongs to the adjacent joints. Accordingly, the objective of this study was to compare how these 2 topping-off devices affect the SIJ biomechanics. 
		                        		
		                        			Methods:
		                        			A validated, normal finite-element lumbopelvic model (L3–pelvis) was initially adjusted to simulate interbody fusion with rigid fixation at the L5–S1 level, and then the DIAM or BioFlex system was instrumented at the L4–5 level to establish the ISS-based or PDF-based topping-off model, respectively. All the developed models were loaded with moments of 4 physiological motions using hybrid loading protocol. 
		                        		
		                        			Results:
		                        			Compared with the rigid fusion model (without topping-off devices), range of motion and von-Mises stress at the SIJs were increased by 23.1%–64.1% and 23.6%–62.8%, respectively, for the ISS-based model and by 51.2%–126.7% and 50.4%–108.7%, respectively, for the PDF-based model. 
		                        		
		                        			Conclusion
		                        			The obtained results suggest that the PDF-based topping-off device leads to higher increments in SIJ motion and stress than ISS-based topping-off device following lumbosacral fusion, implying topping-off technique could be linked to an increased risk of SIJ degeneration, especially when using PDF-based device. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print