1.HerbRNomes: ushering in the post-genome era of modernizing traditional Chinese medicine research
Yu TIAN ; Hai SHANG ; Gui-bo SUN ; Wei-dong ZHANG
Acta Pharmaceutica Sinica 2025;60(2):300-313
With the completion of the "Human Genome Project" and the smooth progress of the "Herbal Genome Project", the research wave of RNAomics is gradually advancing, opening the research gateway for the modernization of traditional Chinese medicine (TCM) and initiating the post-genome era of medicinal plant RNA research. Therefore, this article proposes for the first time the concept of HerbRNomes, which involves constructing databases of medicinal plant, medicinal fungus, and medicinal animal RNA at different stages, from different origins, and in different organs. This research aims to explore the role of HerbRNA in self-genetic information transmission, functional regulation, as well as cross-species regulation functional mechanisms and key technologies. It also investigates application scenarios, providing a theoretical basis and research ideas for the resistance of TCM or medicinal plants to adversity and stress, molecular assistant breeding, and the development of small nucleic acid drugs. This article reviews recent research progress in elucidating the molecular mechanisms of the transmission and expression of genetic information, self-regulation and cross-species regulation of herbs at the RNA level, along with key technologies. It proposes a development strategy for small nucleic acid drugs based on HerbRNomes, providing theoretical support and guidance for the modernization of TCM based on HerbRNomes research.
2.Xiaozhong Zhitong Mixture(消肿止痛合剂)Combined with Antibiotic Bone Cement in the Treatment of Diabetic Foot Ulcers with Damp-Heat Obstructing Syndrome:A Randomized Controlled Trial of 35 Patients
Xiaotao WEI ; Zhijun HE ; Tao LIU ; Zhenxing JIANG ; Fei LI ; Yan LI ; Jinpeng LI ; Wen CHEN ; Bihui BAI ; Xuan DONG ; Bo SUN
Journal of Traditional Chinese Medicine 2025;66(7):704-709
ObjectiveTo observe the clinical effectiveness and safety of Xiaozhong Zhitong Mixture (消肿止痛合剂) combined with antibiotic bone cement in the treatment of diabetic foot ulcer (DFU) with damp-heat obstructing syndrome. MethodsA total of 72 DFU patients with damp-heat obstructing syndrome were randomly assigned to treatment group (36 cases) and the control group (36 cases). Both groups received standard treatment and topical antibiotic bone cement for ulcer wounds, while the treatment group received oral Xiaozhong Zhitong Mixture (50 ml per time, three times daily) in additionally. Both groups underwent daily wound dressing changes for 21 consecutive days. Ulcer healing rate, serum levels of tumor necrosis factor-alpha (TNF-α), interleukin-1 beta (IL-1β), malondialdehyde (MDA), superoxide dismutase (SOD), C-reactive protein (CRP), and white blood cell (WBC) count were observed before and after treatment, and visual analog scale (VAS) scores for wound pain, traditional Chinese medicine (TCM) syndrome scores, and the DFU Healing Scale (DMIST scale) were also compared. Liver and kidney function were evaluated before and after treatment, and adverse events such as allergic reactions, worsening ulcer pain were recorded. ResultsTotally 35 patients in the treatment group and 33 in the control group were included in the final analysis. The ulcer healing rate in the treatment group was (87.93±9.34)%, significantly higher than (81.82±12.02)% in the control group (P = 0.035). Compared to pre-treatment levels, both groups showed significant reductions in serum CRP, WBC, MDA, IL-1β, and TNF-α levels, with an increase in SOD level (P<0.05). TCM syndrome scores, VAS, and DMIST scores also significantly decreased in both groups (P<0.05), with greater improvements in the treatment group (P<0.05). No significant adverse reactions were observed in either group during treatment. ConclusionXiaozhong Zhitong Mixture combined with antibiotic bone cement has significant advantages in promoting DFU healing, reducing inflammatory response, and alleviating oxidative stress in DFU patients with damp-heat obstructing syndrome, with good safety for DFU patients with damp-heat obstructing syndrome.
3.Body Composition Profiles and Associated Factors in Adolescents UndergoingLong-term Regular Exercise
Yutong WANG ; Xiaoyuan GUO ; Hanze DU ; Hui PAN ; Wei WANG ; Mei ZHANG ; Bo BAN ; Ping LI ; Xinran ZHANG ; Qiuping ZHANG ; Hongshuang SUN ; Rong LI ; Shi CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(3):591-597
To investigate body composition and associated factors in adolescents undergoing long-term regular sports training. This prospective longitudinal cohort study employed convenience sampling to recruit adolescents receiving structured athletic training at Jining Sports Training Center in June 2023. Baseline measurements included height, weight, body mass index (BMI), blood pressure, heart rate, waist circumference, and hip circumference. Questionnaires assessed sleep duration, screen time, and household income. Follow-up measurements in June 2024 repeated these assessments while adding bioelectrical impedance analysis for body composition (lean mass, skeletal muscle mass, fat mass, and body fat percentage). Linear regression models examined associations between training type (direct-contact vs. non-contact sports) and follow-up body fat percentage, BMI, and waist circumference as dependent variables, adjusting for covariates. The study included 110 adolescents (39 female, 71 male) with median age 13.21 years (IQR: 12.46-14.33). Participants comprised 65 direct-contact and 45 non-contact athletes. Baseline prevalence rates were 27.27% for overweight/obesity, 24.55% for elevated waist circumference, and 16.36% for elevated blood pressure. At follow-up, corresponding rates were 24.55%, 26.36%, and 13.64% respectively. The elevated blood pressure subgroup showed significantly higher waist circumference ( Despite regular athletic training, substantial proportions of adolescents exhibited overweight/obesity, abdominal obesity, and elevated blood pressure, warranting clinical attention. Training modality appears to influence body composition changes, with direct-contact sports associated with more favorable adiposity-related outcomes.
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Clinical Characteristics and Use of Traditional Chinese Medicine Therapy in 222 Malignant Tumor Cases with COVID-19: A Retrospective Study
Yingtian WANG ; Hong SUN ; Man LI ; Na SONG ; Jiao GOU ; Wenfang LUO ; Jun LIU ; Rong MA ; Wei WANG ; Zhandong LI ; Bo MENG ; Xiaoyan YAO
Journal of Traditional Chinese Medicine 2024;65(7):716-721
ObjectiveTo analyze the clinical characteristics and the use of traditional Chinese medicine (TCM) therapy in cancer patients with COVID-19, and to provide reference for making TCM prevention and treatment strategies and determining diagnosis and treatment priorities for patients with malignant tumors in the COVID-19 epidemic. MethodsThe medical records of 225 malignant tumor cases with COVID-19 who were admitted to 7 national research centers from January 1st to 20th, 2023 were retrospectively collected, and the main symptoms and duration after infection, nucleic acid negative conversion time, use of TCM therapy, and changes in adverse reactions after resuming anti-tumor treatment were analyzed. ResultsA total of 222 malignant tumor patients with COVID-19 were included in the analysis, involving 205 mild cases and 17 moderate cases. The top four most frequently reported clinical symptoms were fever (165 cases), expectoration or dry cough (99 cases), decreased appetite (95 cases) and fatigue (85 cases), of which 40 expectoration or dry cough cases , 37 fatigue cases and 29 decreased appetite cases lasted for more than 14 days. One hundred and five patients with nucleic acid detection report had a median negative conversion time of 14 days. The nucleic acid negative conversion time was significantly longer in patients with lung cancer compared to those with digestive system malignant tumors, and in those with myelosuppression than those without (P<0.01). During the infection period, 47.30% (105/222) of the patients used Chinese patent medicine, and 21.17% (47/222) were treated with herbal decoctions. The use of TCM in patients during the prevention and rehabilitation period, was 1.80%(4/222) and 7.21%(16/222), respectively. Fifty-five patients resumed anti-tumor treatment after nucleic acid negative conversion, and received TCM simultaneously. Observed adverse reactions, including gastrointestinal reactions, bone marrow suppression, and neurotoxicity, were all grade 1 to 2, and no new adverse events occurred during follow-up. ConclusionCertain malignant tumor patients with COVID-19 had prolonged symptoms and nucleic acid negative conversion time Rational use of TCM can help to promote the rehabilitation of the patients and ensure the smooth process of anti-tumor treatment after infection.
8.Longitudinal extrauterine growth restriction in extremely preterm infants: current status and prediction model
Xiaofang HUANG ; Qi FENG ; Shuaijun LI ; Xiuying TIAN ; Yong JI ; Ying ZHOU ; Bo TIAN ; Yuemei LI ; Wei GUO ; Shufen ZHAI ; Haiying HE ; Xia LIU ; Rongxiu ZHENG ; Shasha FAN ; Li MA ; Hongyun WANG ; Xiaoying WANG ; Shanyamei HUANG ; Jinyu LI ; Hua XIE ; Xiaoxiang LI ; Pingping ZHANG ; Hua MEI ; Yanju HU ; Ming YANG ; Lu CHEN ; Yajing LI ; Xiaohong GU ; Shengshun QUE ; Xiaoxian YAN ; Haijuan WANG ; Lixia SUN ; Liang ZHANG ; Jiuye GUO
Chinese Journal of Neonatology 2024;39(3):136-144
Objective:To study the current status of longitudinal extrauterine growth restriction (EUGR) in extremely preterm infants (EPIs) and to develop a prediction model based on clinical data from multiple NICUs.Methods:From January 2017 to December 2018, EPIs admitted to 32 NICUs in North China were retrospectively studied. Their general conditions, nutritional support, complications during hospitalization and weight changes were reviewed. Weight loss between birth and discharge > 1SD was defined as longitudinal EUGR. The EPIs were assigned into longitudinal EUGR group and non-EUGR group and their nutritional support and weight changes were compared. The EPIs were randomly assigned into the training dataset and the validation dataset with a ratio of 7∶3. Univariate Cox regression analysis and multiple regression analysis were used in the training dataset to select the independent predictive factors. The best-fitting Nomogram model predicting longitudinal EUGR was established based on Akaike Information Criterion. The model was evaluated for discrimination efficacy, calibration and clinical decision curve analysis.Results:A total of 436 EPIs were included in this study, with a mean gestational age of (26.9±0.9) weeks and a birth weight of (989±171) g. The incidence of longitudinal EUGR was 82.3%(359/436). Seven variables (birth weight Z-score, weight loss, weight growth velocity, the proportion of breast milk ≥75% within 3 d before discharge, invasive mechanical ventilation ≥7 d, maternal antenatal corticosteroids use and bronchopulmonary dysplasia) were selected to establish the prediction model. The area under the receiver operating characteristic curve of the training dataset and the validation dataset were 0.870 (95% CI 0.820-0.920) and 0.879 (95% CI 0.815-0.942), suggesting good discrimination efficacy. The calibration curve indicated a good fit of the model ( P>0.05). The decision curve analysis showed positive net benefits at all thresholds. Conclusions:Currently, EPIs have a high incidence of longitudinal EUGR. The prediction model is helpful for early identification and intervention for EPIs with higher risks of longitudinal EUGR. It is necessary to expand the sample size and conduct prospective studies to optimize and validate the prediction model in the future.
9.Research progress of large-channel spinal endoscopic posterior lumbar interbody fusion in the treatment of lumbar degenerative diseases
Lin SUN ; Xiaofeng LI ; Zeyu HUANG ; Yingjie WEI ; Ji MA ; Bo SHI ; Lijun LI
International Journal of Surgery 2024;51(7):499-504
Lumbar interbody fusion is a surgical method for treating lumbar degenerative diseases. By establishing the stability of the lumbar segment, it solves the related symptoms caused by lumbar degenerative diseases. Minimally invasive transforaminal lumbar interbody fusion(MIS-TLIF) is a mature technology for treating lumbar degenerative diseases and improving the stability of the lumbar segment. In recent years, the emergence of lumbar interbody fusion under the small-channel working tube has made it have more minimally invasive characteristics compared to MIS-TLIF, with smaller incisions, less bleeding, and shorter recovery time. However, due to its long operation time, low efficiency of endplate treatment, and high complications incidence rate, it has not been widely popularized. At present, the large-channel endoscopic system, because of its larger field of view under the endoscope and more efficient endoscopic operation tools, reduces the operation time, improves the efficiency of endplate treatment, and reduces the postoperative related complications incidence rate. According to the surgical approach, it can be divided into transforaminal approach, posterior approach, oblique anterior approach, etc. According to the channel mode, it can also be divided into uniaxial endoscopy and unilateral dual-channel endoscopy, and each has its own advantages and disadvantages. Nowadays, the safety and effectiveness of spinal endoscopic posterior lumbar interbody fusion(Endo-PLIF) under the large-channel have achieved satisfactory results. This article reviews the research progress of Endo-PLIF under the large-channel, including surgical indications and contraindications, anatomical basis, surgical techniques, the choice of cages, the choice of fixation methods, safety and effectiveness, advantages and disadvantages, and explores its clinical application and prospects.
10.Effects of whole body vibration training combined with blood flow restriction on motor function and com-munity activity in elderly stroke patients with hemiplegia
Liangwen SUN ; Chunxia WEI ; Miao LIU ; Min LU ; Shaojun GAO ; Bo WANG ; Qiang DUAN ; Wei LI ; Xiaoqun HUANG
The Journal of Practical Medicine 2024;40(20):2874-2879
Objective To investigate the impact of whole body vibration training combined with intermittent blood flow restriction on the motor function and community activity in elderly stroke patients with hemiplegia.Methods A total of 80 convalescent hemiplegic patients after stroke who were hospitalized in the Rehabilitation Medicine Department of Yichang Central People's Hospital(Xiling Campus)from October 2021 to December 2023 were included and randomly divided into control group(n=25),vibration group(n=28)and combination group(n=27)using the random number table method.All patients received conventional rehabilitation training,on the basis;the vabration group received whole body vibration training,while the combination group received whole body vibration training combined with intermittent blood flow restriction.Before and after 6 weeks of training,the balance function was evaluated with Berg balance scale(BBS),while the gait function was tested with 6-minute walking test(6MWT)and the Community Balance and Mobility scale(CB&M)was used to assess the community activity ability.The community balance and mobility(CB&M)were evaluated in the first and third month after discharge.Results There was no significant difference in BBS,CB&M scores and 6MWT walking distance between the three groups before training(P>0.05).After 6 weeks of training,the three groups showed significant increases in the BBS,CB&Mscores and the walk distance of 6MWT(P<0.001).Furthermore,compared with the control group,the combination group and the vibration group were significantly beter(P<0.05),and there was no signifi-cant difference between the combination group and the vibration group(P>0.05).At the first and third month of follw-up after discharge,the CB&M scores of the three groups were significantly higher than those of the control group(P<0.05),while there was no significant difference between the CB&M scores of the combination group and the vibration group at the first month of follow-up(P>0.05).But the CB&M scores of the combination group was higher than those of the vibration group at the third month of follow-up,and the difference was statistically signifi-cant(P<0.05).Conclusion On the basis of conventional rehabilitation,whole body vibration training combined with intermittent blood flow restriction can significantly enhance balance function,balance confidence,walking ability and mobility in early stage of community life for elderly stroke patients with hemiplegia,potentially facilitat-ing their return to community life.

Result Analysis
Print
Save
E-mail