1.Mechanism of Modified Shaofu Zhuyutang in Antagonising Ectopic Endometrial Tissue Fibrosis Based on Cellular Pyroptosis Mediated by TRL4/NF-κB/NLPR3 Signaling Pathway
Zuoliang ZHANG ; Jiaxing WANG ; Wanrun WANG ; Xiangyu LIN ; Bin YUE ; Zhirui ZHANG ; Yinan WANG ; Yaling YANG ; Dongqing WEI ; Cancan HUANG ; Quansheng WU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(4):19-28
		                        		
		                        			
		                        			ObjectiveTo investigate the mechanism of action of modified Shaofu Zhuyutang in antagonizing cellular pyroptosis and fibrosis in ectopic endometrial tissues of endometriosis through the Toll-like receptor 4/nuclear factor-κB/NOD-like receptor protein 3 (TRL4/NF-κB/NLPR3) signaling pathway. MethodsSeventy-two SPF-grade female SD rats were randomly divided into a sham-operated group (n = 12) and a modeling group (n = 60). The rats in the sham-operated group underwent a caesarean section, while the rats in the modeling group were used to establish an endometriosis model through the auto-transplantation method. After successful modeling, the animals were randomly divided into the model group, progesterone group (0.25 mg·kg-1), and modified Shaofu Zhuyutang low-, medium-, and high-dose groups (7.5, 15, 30 g·kg-1), with 12 animals in each group. After 4 weeks of drug administration, voluntary activity and heat pain latency were observed. The rats were sacrificed for tissue collection, and Masson staining were used to observe histopathological changes in the endometrial tissues. Enzyme-linked immunosorbent assay (ELISA) was used to measure serum levels of interleukin-18 (IL-18), interleukin-1β (IL-1β), tumor necrosis factor-α (TNF-α), and transforming growth factor-β (TGF-β). Immunohistochemistry (IHC) was used to detect the protein expression area of tumor necrosis factor-related factor 6 (TRAF6) and NLPR3 in the endometrial tissues. Immunofluorescence (IF) was used to detect the relative fluorescence intensity of Caspase-1 and gasdermin D (GSDMD) in the endometrial tissues. Western blot was employed to measure the relative expression of TRL4, myeloid differentiation factor 88 (MyD88), TRAF6, NF-κB p65, phosphorylated NF-κB p65 (p-NF-κB p65), and NLPR3 proteins in endometrial tissues. Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) was used to detect the mRNA expression of TRL4, MyD88, TRAF6, NF-κB, and NLPR3 in the endometrial tissues. ResultsCompared with the sham-operated group, rats in the model group showed reduced voluntary activity and shorter heat pain latency. Serum levels of IL-18, IL-1β, TNF-α, and TGF-β were elevated. The relative expression areas of TRAF6 and NLPR3 proteins were increased, and the relative fluorescence intensity of Caspase-1 and GSDMD was enhanced. The relative expression of TRL4, MyD88, TRAF6, NF-κB p65, p-NF-κB p65, and NLPR3 proteins, along with the expression of TRL4, MyD88, TRAF6, NF-κB, and NLPR3 mRNA, were significantly increased (P<0.01). Compared with the model group, rats in the progesterone group and the modified Shaofu Zhuyutang medium- and high-dose groups exhibited improved voluntary activity, longer heat pain latency, the fibrosis of endometrial tissue is alleviated. Serum levels of IL-18, IL-1β, TNF-α, and TGF-β were decreased. The relative expression areas of TRAF6 and NLPR3 proteins decreased, and the relative fluorescence intensity of Caspase-1 and GSDMD weakened. The relative expression of TRL4, MyD88, TRAF6, p-NF-κB p65, NLPR3 proteins, and TRL4, MyD88, TRAF6, NF-κB, and NLPR3 mRNA expression were reduced (P<0.05, P<0.01). ConclusionModified Shaofu Zhuyutang may play a therapeutic role in endometriosis by interfering with key proteins in the TRL4/NF-κB/NLPR3 signaling pathway, reducing NLRP3 inflammasome-induced cellular pyroptosis, antagonizing the fibrosis process in ectopic endometrial tissues, improving the inflammatory microenvironment in the pelvic cavity, and alleviating pain. 
		                        		
		                        		
		                        		
		                        	
2.Over 20-year Follow-up Result of Total Knee Arthroplasty for Knee Arthropathy: A Single Center Cohort Study
Yiming XU ; Mingwei HU ; Wei ZHU ; Muyang YU ; Jin LIN ; Jin JIN ; Wenwei QIAN ; Bin FENG ; Xisheng WENG
Medical Journal of Peking Union Medical College Hospital 2025;16(1):35-41
		                        		
		                        			
		                        			 To evaluate long-term survival and clinical outcomes of patients with knee osteo-arthritis undergoing total knee arthroplasty (TKA) through long-term follow-up. This study was based on a previous cohort study that had completed follow-up. We retrospectively collected clinical data of patients with knee arthropathy (including knee osteoarthritis and knee rheumatoid arthritis) who received the first TKA operation in Peking Union Medical College Hospital from 1993 to 2002 and were followed up for more than 20 years, and conducted a unified follow-up on them in November 10, 2024 (the last follow-up). Kaplan-Meier curve was used to evaluate the survival rate. Hospitals for special surgery (HSS) scores and joint range of motion (ROM) were compared before surgery, 10 years after surgery and at the last follow-up to evaluate the clinical efficacy of TKA. Likert scale was used to evaluate patient satisfaction at the last follow-up. A total of 226 patients (246 knees) received their first TKA in Peking Union Medical College Hospital from 1993 to 2002 and were followed up for more than 10 years. Among them, 104 patients (131 knees) were included in the study at the last follow-up, including 21 patients (24 knees) with prosthesis in place, 18 patients (18 knees) who underwent reoperation for various reasons, and 65 patients (89 knees) who died from non-TKA surgical causes. Up to the last follow-up, there were 29 patients (35 knees) with an average follow-up of more than 20 years, and 12 patients (16 knees) completed HSS score, ROM measurement and patient satisfaction evaluation. Kaplan-Meier curve showed that the 10-year, 15-year, 20-year, and 25-year survival rates were 93.6%, 92.4%, 89.8%, and 71.8%, respectively. The HSS score at the last follow-up was lower than that at 10- year postoperative follow-up[(84.69±11.03) scores  TKA treatment for knee arthropathy has high long-term prosthesis survival rate, significant improvement of knee joint function and high patient satisfaction.
		                        		
		                        	
3.Implementing standardized school desks and chairs to promote the healthy development of primary and secondary school students
ZHANG Fengyun, SONG Yi, ZHANG Lin, LUO Chunyan, DU Wei, DONG Bin
Chinese Journal of School Health 2025;46(3):305-309
		                        		
		                        			Abstract
		                        			In order to understand and analyze the current standards and application of school desks and chairs for primary and secondary schools, and to promote the healthy growth of primary and secondary school students. The article conducts a comprehensive review of the functional and dimensional standards for school furniture both domestically and internationally, and objectively analyzes the current utilization and existing issues concerning desks and chairs in schools. It further explores the multifaceted factors that influence the allocation of desks and chairs, and proposes effective countermeasures, so as to provide a reference for the risk factors of common diseases related to desks and chairs, such as myopia and abnormal spinal curvature.
		                        		
		                        		
		                        		
		                        	
4.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
		                        		
		                        			
		                        			ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs. 
		                        		
		                        		
		                        		
		                        	
5.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
6.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
7.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
8.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
9.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
		                        		
		                        			 Purpose:
		                        			Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations. 
		                        		
		                        			Methods:
		                        			PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale. 
		                        		
		                        			Results:
		                        			Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633). 
		                        		
		                        			Conclusion
		                        			Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.  
		                        		
		                        		
		                        		
		                        	
10.Determination of the Contents of Three Lignans in Dendrobium fimbriatum Hook
Ying-Hua HUANG ; Lin ZHANG ; Jin-Yan LI ; Zhi-Bin LI ; Zhi-Yun LIANG ; Li-E YANG ; Gang WEI ; Yue-Chun HUANG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(1):207-212
		                        		
		                        			
		                        			Objective To establish the method for content determination of three lignans of Dendrobium Fimbriatum Hook..Methods The lignans in Dendrobium tasselii were identified by high-performance liquid chromatography/multi-stage mass spectrometry(HPLC-ESI/MSn)coupled with ultraviolet absorption spectrometry(UV)coupled with retention time localization of high-performance liquid chromatography(HPLC).The separation was carried out on a Kromasil 100-5 C18 column(4.6 mm×250 mm,5 μm)using a gradient elution of acetonitrile-0.1%formic acid solution as the mobile phase,the volume flow rate was 0.8 mL·min-1 and the column temperature was 35℃,and the mass spectrometry was performed using an ESI ion source with the data collected in the negative ion mode.The HPLC content was determined on the same column as that of MS analysis,with the mobile phase methanol + acetonitrile(V/V=1∶1)-0.01 mol/L ammonium acetate solution,gradient elution,flow rate of 0.8 mL·min-1,column temperature of 40℃,and detection wavelength of 215 nm.Results Syringaresinol di-O-glucoside and(-)-Syringaresinol 4-O-β-D-glucopyranoside and DL-Syringaresinol were identified from Dendrobium fimbriatum Hook.,and the results of content determination showed that the linear ranges of above three components were respectively 0.1701-3.4020,0.1020-2.0400,0.0403-0.8060 μg(r≥0.9995),the average recoveries were in the range of 97.71%-101.67%,and the relative standard deviations(RSDs)were all less than 3.0%.The contents of Syringaresinol di-O-glucoside and(-)-Syringaresinol 4-O-β-D-glucopyranoside and DL-Syringaresinol in the 10 batches of samples were 0.7779-1.3852,0.0734-0.1966,0.0295-0.1882 mg·g-1.Conclusion This research method can provide a reference basis for the quality evaluation method of Dendrobium fimbriatum Hook..
		                        		
		                        		
		                        		
		                        	
            

Result Analysis
Print
Save
E-mail