1.Body Composition Profiles and Associated Factors in Adolescents UndergoingLong-term Regular Exercise
Yutong WANG ; Xiaoyuan GUO ; Hanze DU ; Hui PAN ; Wei WANG ; Mei ZHANG ; Bo BAN ; Ping LI ; Xinran ZHANG ; Qiuping ZHANG ; Hongshuang SUN ; Rong LI ; Shi CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(3):591-597
To investigate body composition and associated factors in adolescents undergoing long-term regular sports training. This prospective longitudinal cohort study employed convenience sampling to recruit adolescents receiving structured athletic training at Jining Sports Training Center in June 2023. Baseline measurements included height, weight, body mass index (BMI), blood pressure, heart rate, waist circumference, and hip circumference. Questionnaires assessed sleep duration, screen time, and household income. Follow-up measurements in June 2024 repeated these assessments while adding bioelectrical impedance analysis for body composition (lean mass, skeletal muscle mass, fat mass, and body fat percentage). Linear regression models examined associations between training type (direct-contact vs. non-contact sports) and follow-up body fat percentage, BMI, and waist circumference as dependent variables, adjusting for covariates. The study included 110 adolescents (39 female, 71 male) with median age 13.21 years (IQR: 12.46-14.33). Participants comprised 65 direct-contact and 45 non-contact athletes. Baseline prevalence rates were 27.27% for overweight/obesity, 24.55% for elevated waist circumference, and 16.36% for elevated blood pressure. At follow-up, corresponding rates were 24.55%, 26.36%, and 13.64% respectively. The elevated blood pressure subgroup showed significantly higher waist circumference ( Despite regular athletic training, substantial proportions of adolescents exhibited overweight/obesity, abdominal obesity, and elevated blood pressure, warranting clinical attention. Training modality appears to influence body composition changes, with direct-contact sports associated with more favorable adiposity-related outcomes.
2. Establishment and genotype identification of hepatic stellate cell-specific Grk2 gene knockout mouse model
Yu-Han WANG ; Ya-Ping XU ; Nan LI ; Ting-Ting CHEN ; Ling LI ; Ping-Ping GAO ; Wei WEI ; Wu-Yi SUN ; Hua WANG
Chinese Pharmacological Bulletin 2024;40(1):189-194
Aim To establish a stable hepatic stellate cell ( HSC ) -specific G protein-coupled receptor kinase 2 ( GRK2 ) knockout mice and provide the important animal model for further studying the biological function of GRK2 in HSC. Methods The loxP-labeled Grk2 gene mouse (Grk2
3. The molecular mechanism of spleen-strengthening and moisture-nourishing liver prescription in treatment of acute-on-chronic liver failure based on network pharmacology and experimental verification
Qi HUANG ; Wen-Feng MA ; Zhi-Yi HAN ; Jia-Ling SUN ; Wei ZHANG ; Xin-Feng SUN ; Jian -Ping CHEN ; Xiao-Zhou ZHOU ; Qi HUANG ; Wen-Feng MA ; Zhi-Yi HAN ; Jia-Ling SUN ; Wei ZHANG ; Xin-Feng SUN ; Xiao-Zhou ZHOU ; Jing LI ; Xiao-Zhou ZHOU ; Jian -Ping CHEN
Chinese Pharmacological Bulletin 2024;40(3):557-564
To explore the mechanism of spleen- were obtained for the treatment of acute-on-chronic livstrengthening and moisture-nourishing liver prescription er failure, and 244 intersecting target genes and 7 core (JPLSYGF) in the treatment of acute-on-chronic liver target genes were screened. Molecular docking showed failure using network pharmacology and the molecular that the core target genes AKT1, SRC, VEGFA, docking. Methods Relying on TCMSP and Gene- STAT3 , EGFR, MAPK3 , HRAS had good affinity with Cards and other databases, the relevant targets of JPL- quercetin, the main active component in the JPLSYGF in the treatment of acute-on-chronic liver failure SYGF, and had strong binding activity. In addition, in were obtained. String and Cytoscape were used to con- vivo tests verified that the JPLSYGF could reduce the struct PPI networks of targets, core targets were expression of HRAS, EGFR, STAT3 , SRC, and VEGscreened out, and DAVID was used for GO function FA, to delay the progression of acute-on-chronic liver annotation and KEGG pathway enrichment analysis. failure. Conclusions JPLSYGF may act on core tar- The main active ingredients of the traditional Chinese gets such as HRAS, EGFR, STAT3, SRC, VEGFA medicine compound formula for JPLSYGF were select- and so on, to achieve the effect of treating acute-oned with a bioavailability OB value of =Э 30% and a chronic liver failure. drug-like DL^O. 18 as the screening conditions, and.
4.Research progress of natural product evodiamine-based antitumor drug design strategies
Zhe-wei XIA ; Yu-hang SUN ; Tian-le HUANG ; Hua SUN ; Yu-ping CHEN ; Chun-quan SHENG ; Shan-chao WU
Acta Pharmaceutica Sinica 2024;59(3):532-542
Natural products are important sources for the discovery of anti-tumor drugs. Evodiamine is the main alkaloid component of the traditional Chinese herb Wu-Chu-Yu, and it has weak antitumor activity. In recent years, a number of highly active antitumor candidates have been discovered with a significant progress. This article reviews the research progress of evodiamine-based antitumor drug design strategies, in order to provide reference for the development of new drugs with natural products as leads.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Construction and preliminary application of a training program of operating room nurses for returning to work after delivery based on work adaptation theory
Ping BAI ; Yongting WEI ; Zhichao SUN ; Xiaofan DONG ; Jianhua WANG ; Feng WANG ; Qi YAO
Chinese Journal of Nursing 2024;59(1):77-84
Objective To construct a training program for retuming to work after delivery based on Morrison's job adaptation theory in operating room nurses and to explore its application effect.Methods On the basis of literature research and Delphi expert consultation method,a training program of postpartum return of operating room nurses was constructed.From August 2021 to December 2022,the preliminary application of this research program was carried out,with 6 cases in an experimental group and 5 cases in a control group.The differences between the 2 groups were compared by Job Adaptation Scale,Psychological Resilience Scale and satisfaction evaluation,and the application effect was evaluated.Results After 2 rounds of correspondence,a training program for postpartum return of operating room nurses was formed,which included 4 first-level indicators(role adaptation,task adaptation,environment adaptation and cultural adaptation),and 32 second-level indicators.The authority coefficients of the 2 rounds of correspondence consultation were 0.908 and 0.917,and the Kendall W coefficients were 0.224 and 0.206,respectively(both P<0.001).The preliminary application results showed that there were statistically significant differences in job adaptation and satisfaction evaluation between the 2 groups(both P<0.05).There was no significant difference in psychological resilience score between groups(P>0.05).Conclusion The postpartum retum training program for operating room nurses established in this study is scientific and practical to a certain extent.In the future,samples can be expanded and multi-center studies can be carried out to further test the practicability and effectiveness of the program.
8.The value of CEA, CYFRA21-1 and CA125 tests in opportunistic screening for non-small cell lung cancer: a meta-analysis
Honghai HE ; Huihui ZHANG ; Hua WU ; Hongli WANG ; Wei ZHAO ; Ping SUN ; Peng WANG
Chinese Journal of Health Management 2024;18(4):254-262
Objective:To evaluate the value of CEA, CYFRA21-1 and CA125 tests in opportunistic screening of non-small cell lung cancer (NSCLC) based on meta-analysis.Methods:The original research literatures on the diagnostic value of CEA, CYFRA21-1 and CA125 in Chinese NSCLC patients were searched from databases of PubMed, Embase, The Cochrane Library, CNKI, VIP, Database and Wanfang database from establishment to June 2023. The literature screening, data extraction and quality evaluation were carried out independently by two researchers. The quality evaluation tool of diagnostic accuracy studies was used to evaluate the quality of the literature. A summary receiver operating characteristic (SROC) curve was used to assess the overall effectiveness of the tests. The outcome stability and publication bias were detected by using sensitivity analysis and Deeks′ test.Results:A total of 23 studies met the inclusion and exclusion criteria were included. The results of meta-analysis showed that the overall sensitivity of CEA, CYFRA21-1 and CA125 alone in the diagnosis of NSCLC was relatively low, it was 0.49(95% CI: 0.43-0.55), 0.56(95% CI: 0.49-0.63) and 0.41(95% CI: 0.33-0.49), respectively. The overall sensitivity of the combined detection of the three markers for the diagnosis of NSCLC increased to 0.83(95% CI: 0.69-0.91), but the overall specificity decreased to 0.76(95% CI: 0.69-0.83). Conclusions:The single detection of CEA, CYFRA21-1 and CA125 is not recommended for screening NSCLC in population receiving physical examination. Although the sensitivity of the combined detection of CEA, CYFRA21-1 and CA125 for screening NSCLC is improved, but the specificity is decreased, the misdiagnosis rate is increased, so the screening effect is limited.
9.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
10.Implementation of surveillance,prevention and control of healthcare-asso-ciated infection in maternal and child healthcare institutions:A nation-wide investigation report
Shuo LI ; Xi YAO ; Hui-Xue JIA ; Wei-Guang LI ; Xun HUANG ; Shu-Mei SUN ; Xi CHENG ; Qing-Lan MENG ; Xiang ZHANG ; Jing-Ping ZHANG ; Ya-Wei XING ; Qing-Qing JIANG ; Lian-Xuan WU ; Bing-Li ZHANG ; Xiao-Jing LIU ; Liu-Yi LI
Chinese Journal of Infection Control 2024;23(3):323-329
Objective To investigate the implementation of surveillance,prevention and control measures for healthcare-associated infection(HAI)in maternal and child healthcare(MCH)institutions,and provide policy evi-dence for optimizing HAI prevention and control in MCH institutions.Methods Stratified sampling was conducted among the MCH institutions at provincial,municipal and county levels in 8 provinces/autonomous regions.A uni-fied questionnaire was designed and the online survey was conducted through"Questionnaire Star".Results The data from 123 MCH institutions were included in the analysis.90.24%of the MCH institutions carried out compre-hensive surveillance on HAI.The ratios of MCH institutions which implemented targeted surveillance on HAI in neonatal intensive care unit(NICU),surgical site infection,multidrug-resistant organisms(MDROs)and HAI in intensive care units(non-NICU excluded)were 89.66%,85.96%,80.77%,and 74.19%,respectively.51.22%MCH institutions adopted information surveillance system on HAI cases.94.31%MCH institutions carried out surveillance on hand hygiene compliance.Over 90%MCH institutions carried out surveillance on environment hy-giene in high-risk departments.71.54%MCH institutions conducted centralized cleaning,disinfection,sterilization and supply for reusable medical instruments in the central sterile supply department(CSSD).Over 90%MCH insti-tutions established three-level pre-examination triage systems.86.18%set up transitional wards.MCH institutions generally adopted a management model with established effective communication,full appointment visits,and sepa-rate visits for special medical groups,such as registered pregnant women,high-risk newborns,healthcare groups,and long-term rehabilitation patients.However,the ratio of institutions conducting on-line follow-up visits was less than 50%.Conclusion MCH institutions have generally carried out comprehensive and targeted surveillance on HAI.Information surveillance need to be facilitated.Hand hygiene and environmental hygiene surveillance has been popularized to a certain extent at all levels of MCH institutions.The cleaning,disinfection,sterilization,and supply processes of reusable medical devices in a few MCH institutions are not standardized.Special medical populations get effective management.On-line healthcare is to be further promoted.

Result Analysis
Print
Save
E-mail