1.Research progress of nano drug delivery system based on metal-polyphenol network for the diagnosis and treatment of inflammatory diseases
Meng-jie ZHAO ; Xia-li ZHU ; Yi-jing LI ; Zi-ang WANG ; Yun-long ZHAO ; Gao-jian WEI ; Yu CHEN ; Sheng-nan HUANG
Acta Pharmaceutica Sinica 2025;60(2):323-336
Inflammatory diseases (IDs) are a general term of diseases characterized by chronic inflammation as the primary pathogenetic mechanism, which seriously affect the quality of patient′s life and cause significant social and medical burden. Current drugs for IDs include nonsteroidal anti-inflammatory drugs, corticosteroids, immunomodulators, biologics, and antioxidants, but these drugs may cause gastrointestinal side effects, induce or worsen infections, and cause non-response or intolerance. Given the outstanding performance of metal polyphenol network (MPN) in the fields of drug delivery, biomedical imaging, and catalytic therapy, its application in the diagnosis and treatment of IDs has attracted much attention and significant progress has been made. In this paper, we first provide an overview of the types of IDs and their generating mechanisms, then sort out and summarize the different forms of MPN in recent years, and finally discuss in detail the characteristics of MPN and their latest research progress in the diagnosis and treatment of IDs. This research may provide useful references for scientific research and clinical practice in the related fields.
2.Hypoxia Exercise Mediates The miR-27/PPARγ Pathway to Improve Lipid Metabolism in Obese Rats at Target Genes and Protein Levels
Wei KONG ; Jie SHAO ; Teng ZHAI ; Qian CHENG ; Fang-Zheng HAN ; Yi QU ; Lei ZHU
Progress in Biochemistry and Biophysics 2025;52(6):1386-1400
ObjectiveTo explore the sequential effects of hypoxic exercising on miR-27/PPARγ and lipid metabolism target gene and protein expression levels in the obesity rats’ liver. Methods13-week-old male diet-induced obesity rats were randomly divided into three groups (n=10): normal oxygen concentration quiet group (N), hypoxia quiet group (H), hypoxic exercise group (HE). Exercise training on the horizontal animal treadmill for 1 h/d, 5 d/week for a total of 4 week, and the intensity of horizontal treadmill training was 20 m/min (hypoxic concentration was 13.6%). Comparison of the weights of perirenal fat and epididymal fat in rats across different groups and calculation of Lee’s index based on body weight and body length of rats in each group were done. And the serum concentrations of total cholesterol (TC), triglyceride (TG), low density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C) levels were detected. RT-PCR and Western Blot were used to detect the levels of miR-27, PPARγ, CYP7A1 and CD36. ResultsHypoxic exercise decreased the expression levels of miR-27 in the obese rats’ liver, however, the expression level of PPARγ was gradually increased. The expression levels of miR-27 in HE group were significantly lower than N group (P<0.05). The expression levels of PPARγ mRNA in N group were significantly lower than H group (P<0.05), especially lower than HE group (P<0.01). The protein expression of PPARγ protein in N group was significantly lower than that other groups (P<0.01). The expression of lipid metabolism-related genes and proteins increased in the obese rats’ liver. The expression of CYP7A1 mRNA in N group was significantly lower than H group (P<0.05), especially lower than HE group (P<0.01). The expression of CYP7A1 protein in the obese rats’ liver in N group was extremely lower than H group and HE group (P<0.01). The protein expression of CD36 in N group was significantly lower than that in HE group (P<0.05). Hypoxia exercise improved the related physiological and biochemical indexes of lipid metabolism disorder. The perirenal fat weight of obese rats in HE group was extremely lower than N group and H group (P<0.01), and the perirenal fat weight in N group was significantly higher than H group (P<0.05). The epididymal fat weight in N group was significantly higher than H group (P<0.05), and extremely higher than HE group (P<0.01). The Lee’s index in HE group was extremely lower than N group and H group (P<0.01). The serum concentration of TC in obese rats in HE group was extremely lower than N group and H group (P<0.01). The serum concentration of TG in HE group was extremely lower than N group and H group (P<0.01). The serum concentration of LDL-C in N group was extremely higher than HE group (P<0.01). The serum concentration of HDL-C in N group was extremely lower than H group (P<0.01). ConclusionHypoxia and hypoxia exercise may negatively regulate the levels of PPARγ by inhibiting miR-27 in the obese rats’ liver, thereby affecting the expression of downstream target genes CYP7A1 and CD36, and promoting cholesterol, fatty acid oxidation and HDL-C transport in the liver, and ultimately the lipid levels in obese rats were improved. The effect of hypoxia exercise on improving blood lipid is better than simple hypoxia intervention.
3.The Genetic Polymorphism and Structural Analysis of 47 Microhaplotypes in a Jiangsu Changshu Chinese Han Population
Kun-Peng PAN ; Yao-Sen FENG ; Wen-Shuai YU ; Zong-Wei LIU ; Yi-Ren YAO ; Jie ZHAO ; Ke-Lai KANG ; Chi ZHANG ; Le WANG ; Jian WU
Progress in Biochemistry and Biophysics 2024;51(2):423-434
ObjectiveTo investigate the genetic polymorphism and structure of 47 autosomal microhaplotypes in the Han population in Changshu City, Jiangsu Province, and to evaluate the forensic efficiencies and forensic parameters. MethodsThe DNA library of unrelated individual samples was prepared according to MHSeqTyper47 kit manual and sequenced on the MiSeq FGx platform. Microhaplotype genotyping and sequencing depth statistics were processed using MHTyper. The genetic information of samples was then evaluated. The fixation index and genetic distance between the Jiangsu Changshu population and the reference populations in the 1000 Genomes Project phase 3 (1KG) were calculated, and forensic parameters were evaluated. ResultsThe fixation index and genetic distance between the Han population in Changshu, Jiangsu, and the CHB (Han Chinese in Beijing, China) reference population in 1KG were the lowest. The effective allele number (Ae) of each locus is also the closest between the two populations. The combined matching probability (CMP) of the Changshu Han population is close to the 5 populations of the East Asian reference super-population in 1KG, which is 1.25×10-36, and the combined probability of exclusion reached 0.999 999 999 964 1. ConclusionThis study reported the genetic polymorphism and allele frequency of 47 microhaplotypes in a Han population in Changshu City, Jiangsu Province. This information provides a data basis for 47 microhaplotypes in forensic applications. In addition, the polymorphism differences between the 1KG reference population and the Han population in Changshu, Jiangsu were compared, and the genetic structure of 47 microhaplotypes in the Han population in Changshu, Jiangsu was revealed. In general, the reference data of the East Asian super-population in 1KG is more in line with the genetic characteristics of Han population in Changshu, Jiangsu.
4.Study on the catalytic mechanism of triterpene C-29 carboxylases from Tripterygium wilfordii based on directed evolution
Pan-ting LIU ; Yi-feng ZHANG ; Yuan LIU ; Jie GAO ; Lin MA ; Xiao-yi WU ; Ya-ting HU ; Ping SU ; Shi-jun YUAN ; Xia-nan ZHANG ; Wei GAO
Acta Pharmaceutica Sinica 2024;59(6):1883-1893
Celastrol and wilforlide A are the main active triterpenoids of the traditional Chinese medicine Lei Gong Teng, which have anti-tumour, anti-inflammatory and immunosuppressive activities, and are the material basis for the clinical efficacy of Lei Gong Teng-related Chinese medicinal preparations. By analysing the biosynthetic pathway of active ingredients, optimizing genetic elements and utilizing "cell factory" to produce triterpenoids heterologously will be an effective way to obtain from
5.Construction of nursing quality evaluation index system for pediatric orthopedics
Nan WANG ; Wei JIN ; Yanzhen HU ; Jie HUANG ; Dan ZHAO ; Juan XING ; Changhong LI ; Yanan HU ; Yi LIU ; Xuemei LU ; Zheng YANG
Chinese Journal of Practical Nursing 2024;40(9):655-664
Objective:To construct a representative index system for evaluating pediatric orthopedic nursing quality, providing a basis for hospital pediatric orthopedic nursing quality assessment and monitoring.Methods:From April to July 2023, using the "structure-process-outcome" three-dimensional quality structure model as the theoretical framework, a literature review was conducted, and an item pool was formulated. Through two rounds of Delphi method expert consultations, the hierarchical analysis method was finally employed to determine the indicators and their weights at each level.Results:The effective recovery rates of the questionnaire of the two rounds of expert consultations were 100% (20/20), the authority coefficients of experts were 0.87 and 0.88, the coefficients of variation were 0.00 to 0.27 and 0.00 to 0.24. The Kendell harmony coefficients of the second and third indicators in the two rounds of inquiry were 0.140, 0.166 and 0.192, 0.161(all P<0.05). The final pediatric orthopedic nursing quality evaluation index system included 3 primary indicators, 21 secondary indicators and 83 tertiary indicators. Among the primary indicators, the weight of process quality was the highest at 0.493 4, followed by outcome quality at 0.310 8, and the lowest was structural quality at 0.195 8. In the secondary indicators, "assessment criteria of limb blood circulation" had the highest weight at 0.099 8. Conclusions:The constructed pediatric orthopedic nursing quality evaluation index system covers key aspects and is more operationally feasible. It provides better guidance for nursing interventions and quality control.
6.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.
7.Application of bio-inks for 3D printing in tissue repair and regenerative medicine
Jie YANG ; Haolei HU ; Shuo LI ; Wei YUE ; Tao XU ; Yi LI
Chinese Journal of Tissue Engineering Research 2024;28(3):445-451
BACKGROUND:With the right bio-inks,3D printing can be used to create replacements for human tissues and organs that work inside the body.In recent years,3D printing technology has developed rapidly and has great application potential in regenerative medicine. OBJECTIVE:To introduce the types of bio-inks for 3D printing,and review the classification,application,advantages and disadvantages of bio-inks,as well as the future vision. METHODS:With"3D printing,biological ink,tissue engineering,hydrogel,synthetic material,cytoactive factor"as search terms,relevant articles published on PubMed and CNKI databases from 2000 to 2022 were searched by computer and finally 83 articles were included for review. RESULTS AND CONCLUSION:3D bioprinting technology has developed rapidly over the past few decades and has received great attention in various fields,including tissue engineering and biomedicine.Compared with the limitations of traditional biological scaffold manufacturing methods in terms of function and structure,3D printing can better simulate the complex structure of biological tissues and has appropriate mechanical,rheological and biological characteristics.Bio-ink is an essential part of 3D printing.Bioscaffolds produced by printing bio-ink prepared by biological materials have great scientific potential and clinical significance in tissue repair and regenerative medicine.The research of the materials itself is also getting more and more attention from experts.Bio-inks for 3D printing come in a variety of materials,from natural to synthetic,to aggregations of cells that do not require any additional biomaterials,and their usefulness in practical use varies.In the future,more and more bio-inks will be developed for tissue engineering.It is necessary to analyze the printability of bio-inks through sufficient experimental simulation and equipment testing to meet the actual medical needs.
8.Diagnostic value of ultra-wide field swept-source optical coherence tomo-graphy angiography combined with ultra-wide field scanning laser ophthal-moscopy in diabetic retinopathy
Mingzhu MAO ; Mengyu LI ; Dingyang WEI ; Li CHEN ; Yi LIU ; Jie LI ; Jie ZHONG
Recent Advances in Ophthalmology 2024;44(4):291-296
Objective To investigate the detection rate and grading diagnostic value of ultra-wide field swept-source optical coherence tomography angiography(UWF SS-OCTA)combined with ultra-wide field scanning laser ophthalmoscopy(UWF SLO)in diabetic retinopathy(DR)lesions.Methods In this cross-sectional study,diabetic patients attending the Ophthalmology Department of Sichuan Provincial Peoples Hospital were recruited.All participants underwent UWF SS-OC-TA,UWF SLO and fundus fluorescein angiography to detect DR lesions,including microaneurysms(MA),intraretinal hem-orrhages(IRH),nonperfusion areas(NPAs),intraretinal microvascular abnormalities(IRMAs),venous beading(VB),neovascularization elsewhere(NVE),neovascularization of the optic disc(NVD),and vitreous hemorrhage(VH).The re-sults of the combination of three imaging examinations(triple imaging)were used as the standards,evaluating the detec-tion rate and severity grading consistency in DR lesions of pairwise combinations of different imaging modalities.Results A total of 101 patients(175 eyes)were included.Compared with the triple imaging results,the detection rates of UWF SS-OCTA combined with UWF SLO for MA,IRH,NPAs,IRMAs,NVE,NVD and VH were 91%,83%,77%,69%,27%,10%and 12%,respectively,with Kappa values of 0.812,1.000,1.000,1.000,0.986,0.970 and 1.000.Compared with the triple imaging results,the combination of UWF SS-OCTA and UWF SLO demonstrated excellent consistency in grading the severity of DR(Kappa=0.943).Conclusion UWF SS-OCTA combined with UWF SLO can accurately identify MA,IRH,NPAs,IRMAs,NVE,NVD and VH,demonstrating high accuracy in DR screening and grading diagnosis,making it suitable for large-scale screening and management of DR in clinical practice.
9.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.
10.Expert consensus on digital intraoral scanning technology
Jie YOU ; Wenjuan YAN ; Liting LIN ; Wen-Zhen GU ; Yarong HOU ; Wei XIAO ; Hui YAO ; Yaner LI ; Lihui MA ; Ruini ZHAO ; Junqi QIU ; Jianzhang LIU ; Yi ZHOU
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(8):569-577
Digital intraoral scanning is a hot topic in the field of oral digital technology.In recent years,digital intra-oral scanning has gradually become the mainstream technology in orthodontics,prosthodontics,and implant dentistry.The precision of digital intraoral scanning and the accuracy and stitching of data collection are the keys to the success of the impression.However,the operators are less familiar with the intraoral scanning characteristics,imaging process-ing,operator scanning method,oral tissue specificity of the scanned object,and restoration design.Thus far,no unified standard and consensus on digital intraoral scanning technology has been achieved at home or abroad.To deal with the problems encountered in oral scanning and improve the quality of digital scanning,we collected common expert opin-ions and sought to expound the causes of scanning errors and countermeasures by summarizing the existing evidence.We also describe the scanning strategies under different oral impression requirements.The expert consensus is that due to various factors affecting the accuracy of digital intraoral scanning and the reproducibility of scanned images,adopting the correct scanning trajectory can shorten clinical operation time and improve scanning accuracy.The scanning trajec-tories mainly include the E-shaped,segmented,and S-shaped methods.When performing fixed denture restoration,it is recommended to first scan the abutment and adjacent teeth.When performing fixed denture restoration,it is recommend-ed to scan the abutment and adjacent teeth first.Then the cavity in the abutment area is excavated.Lastly,the cavity gap was scanned after completing the abutment preparation.This method not only meets clinical needs but also achieves the most reliable accuracy.When performing full denture restoration in edentulous jaws,setting markers on the mucosal tissue at the bottom of the alveolar ridge,simultaneously capturing images of the vestibular area,using different types of scanning paths such as Z-shaped,S-shaped,buccal-palatal and palatal-buccal pathways,segmented scanning of dental arches,and other strategies can reduce scanning errors and improve image stitching and overlap.For implant restora-tion,when a single crown restoration is supported by implants and a small span upper structure restoration,it is recom-mended to first pre-scan the required dental arch.Then the cavity in the abutment area is excavated.Lastly,scanning the cavity gap after installing the implant scanning rod.When repairing a bone level implant crown,an improved indi-rect scanning method can be used.The scanning process includes three steps:First,the temporary restoration,adjacent teeth,and gingival tissue in the mouth are scanned;second,the entire dental arch is scanned after installing a standard scanning rod on the implant;and third,the temporary restoration outside the mouth is scanned to obtain the three-di-mensional shape of the gingival contour of the implant neck,thereby increasing the stability of soft tissue scanning around the implant and improving scanning restoration.For dental implant fixed bridge repair with missing teeth,the mobility of the mucosa increases the difficulty of scanning,making it difficult for scanners to distinguish scanning rods of the same shape and size,which can easily cause image stacking errors.Higher accuracy of digital implant impres-sions can be achieved by changing the geometric shape of the scanning rods to change the optical curvature radius.The consensus confirms that as the range of scanned dental arches and the number of data concatenations increases,the scanning accuracy decreases accordingly,especially when performing full mouth implant restoration impressions.The difficulty of image stitching processing can easily be increased by the presence of unstable and uneven mucosal mor-phology inside the mouth and the lack of relatively obvious and fixed reference objects,which results in insufficient ac-curacy.When designing restorations of this type,it is advisable to carefully choose digital intraoral scanning methods to obtain model data.It is not recommended to use digital impressions when there are more than five missing teeth.


Result Analysis
Print
Save
E-mail