1.Improving the Certainty of Evidence in Animal Experiment Systematic Review/Meta-Analysis: An Empirical Study of the GRADE Method
Tengfei LI ; Qingyong ZHENG ; Jianguo XU ; Yiyi LI ; Yongjia ZHOU ; Caihua XU ; Mingyue ZHANG ; Jiexiang TIAN ; Gang WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2025;45(1):101-111
Animal experiments are essential tools in biomedical research, serving as a bridge between basic research and clinical trials. Systematic reviews and meta-analyses (SRs/MAs) of animal experiments are crucial methods for integrating evidence from animal experiment, which can facilitate the translation of findings into clinical research, reduce translational risks, and promote resource integration in basic research. With the continuous development of the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology, its application in SRs/MAs of animal experiments has gained increasing attention. This article first outlines the principles and specific applications of the GRADE methodology in SRs/MAs of animal experiments, including qualitative descriptive systematic reviews, meta-analyses, and network meta-analyses. It then deeply analyzes the misuse of the GRADE methodology in practice, including incorrect evidence grading, improper classification of evidence, misapplication in qualitative systematic reviews, inconsistencies between the documentation of the upgrading and downgrading process and results, and inappropriate use for making recommendations. Furthermore, this article comprehensively discusses the factors influencing the grading of evidence certainty in SRs/MAs of animal experiments, including the impact of bias risk, indirectness, inconsistency, imprecision, and publication bias on evidence downgrading, as well as the role of large effect sizes and cross-species consistency in evidence upgrading. Finally, in response to the issues discussed, improvement strategies are proposed, including further research and optimization of the GRADE methodology for SRs/MAs of animal experiments, the development of reporting guidelines tailored to the characteristics of SRs/MAs in animal experiment research, and enhanced professional training for researchers in the GRADE methodology. This article aims to improve the quality of evidence in SRs/MAs of animal experiments, strengthen their reliability in clinical decision-making, and promote the more efficient translation of findings from animal experiment research into clinical practice.
2.Determination of biological activity of teduglutide by a homogeneous time-resolved fluorescence method
Xiao-ming ZHANG ; Ran MA ; Li-jing LÜ ; Lü-yin WANG ; Ping LÜ ; Cheng-gang LIANG ; Jing LI
Acta Pharmaceutica Sinica 2025;60(1):211-217
In this study, we constructed a GLP-2R-HEK293 cell line and established a method for the determination of the
3.Cross lag analysis of cumulative ecological risk and future orientation with health risk behaviors among higher vocational college students
ZENG Zhi, FU Gang, LI Ke, WANG Meifeng, WU Lian, ZHANG Tiancheng, ZHANG Fulan
Chinese Journal of School Health 2025;46(3):348-352
Objective:
To explore the causal link of cumulative ecological risk and future orientation with health risk behaviors among higher vocational college students, so as to provide reference for reducing and preventing health risk behaviors among higher vocational college students.
Methods:
A longitudinal follow up study was conducted on 612 students using convenience sampling from 2 vocational colleges in Hunan Province. The Cumulative Ecological Risk Scale, Future Orientation Scale, and Health Risk Behavior Scale were used during three follow up visits (T1: September 2022, T2: June 2023, T3: March 2024), and a cross lagged panel model was constructed to examine the longitudinal causal relationship of cumulative ecological risk, future orientation and health risk behaviors. Analysis of longitudinal intermediary effect between variables by Bootstrap.
Results:
The cumulative ecological risk scores of T1, T2 and T3 among higher vocational college students were (2.94±1.44,2.99±1.63,3.02±1.54), future orientation scores (40.49±4.71,41.51±5.72,41.06±4.35) and health risk behavior scores (3.73±2.01,3.49±2.00,3.23±2.00). The results of repeated measures ANOVA showed that the future orientation score of T2 was higher than that of T1, and the main effect of measurement time was statistically significant ( F=5.09,P<0.01,η 2=0.02). The health risk behavior score of T1 was higher than that of T2, and the health risk behavior score of T2 was higher than that of T3, and the main effect of measurement time was statistically significant ( F=10.12,P<0.01,η 2=0.03).The cross lagged model showed good adaptability, with χ 2/df =7.20 ( P <0.01), relative fitting indicators GFI=0.98, CFI=0.99, TLI=0.96, IFI=0.99, NFI =0.99, and absolute fitting indicator RMSEA =0.06. Among them, the T1, T2 cumulative ecological risk showed negatively predictive effects on T2, T3 future orientation ( β =-0.24, -0.47 ), and T1, T2 cumulative ecological risk positively predicted T2, T3 health risk behavior ( β =0.20, 0.24), while T1, T2 future orientation negatively predicted T2, T3 health risk behavior ( β =-0.25, -0.18) ( P <0.01). Bootstrap test analysis found that T2 future orientation had a longitudinal mediating effect ( β=0.04, P <0.01) on the T1 cumulative ecological risk and T3 health risk behavior.
Conclusions
The accumulation of ecological risk among higher vocational college students can positively predict health risk behaviors, while future orientation can negatively predict healthrisk behaviors. Moreover, future orientation plays a longitudinal mediating role between accumulated ecological risks and health risk behaviors.
4.Construction of evaluation index system of infectious disease prevention and control ability in colleges and universities
Chinese Journal of School Health 2025;46(3):438-442
Objective:
To construct a scientific and perfect evaluation index system of infectious disease prevention and control ability in colleges and universities, so as to provide reference tools for colleges and universities to effectively respond to infectious disease.
Methods:
The initial framework of the evaluation index system of infectious disease prevention and control ability in colleges and universities was constructed by using literature analysis method. Experts familiar with infectious disease prevention and control or school health work were selected to conduct two rounds( n =16,18) of Delphi expert consultation for determining the evaluation index system. Analytical hierarchy process was used to calculate the index weights and combined weights. About 198 prevention and control personnel were conveniently selected from 3 universities in Inner Mongolia Autonomous Region to comprehensively evaluate the evaluation indicators by using fuzzy comprehensive evaluation method.
Results:
After two rounds of Delphi consultation questionnaire, the effective recovery rates were 80.0% and 90.0%, the expert authority levels were 0.89 and 0.86, the expert harmony coefficients for Kendall W were 0.166 and 0.310, and the variation coefficient of each index was <0.25. Finally, the evaluation index system of infectious disease prevention and control ability of colleges and universities included 4 first level indicators, 14 second level indicators and 75 third level indicators. The weights of prevention and monitoring and early warning, organizational system guarantee, emergency management, rehabilitation and summary were 0.176, 0.476, 0.268 and 0.080, respectively. The top 3 weights of the secondary indexes were 0.623 for infectious disease surveillance and early warning, 0.595 for loss assessment and 0.370 for emergency response. The score of fuzzy comprehensive evaluation of the index system of infectious disease prevention and control ability in colleges and universities was 79.148, suggesting a high level.
Conclusion
The established evaluation index system of infectious disease prevention and control ability in colleges and universities is scientific and reasonable, which is conducive to provide tool reference for the evaluation of infectious disease prevention and control ability in colleges and universities.
5.Bufei Tongbi Decoction Inhibits Pulmonary Fibrosis in Diabetic Rats via TGF-β1/p-Smad3 Signaling Pathway
Gang WANG ; Rensong YUE ; Qiyue YANG ; Dan ZHANG ; Xin CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):176-184
ObjectiveTo study the effect of Bufei Tongbi decoction on pulmonary fibrosis in diabetic rats via the transforming growth factor-β1 (TGF-β1)/phosphorylated Smad family member 3 (p-Smad3) signaling pathway. MethodsStreptozotocin (60 mg·kg-1) and bleomycin (24.80 U·kg-1) were used to prepare the rat model of diabetes with pulmonary fibrosis by intratracheal injection. Sixty rats were randomly assigned into blank, model, low-, medium-, and high-dose (3.98, 7.95, and 15.90 g·kg-1, respectively) Bufei Tongbi decoction, and pirfenidone (0.36 mg·kg-1) groups (n=10). The successfully modeled rats in each group were administrated with corresponding agents once per day for four consecutive weeks. After drug administration, fasting blood glucose and lung function indicators were measured. Chemical immunoassay was employed to determine the serum levels of hydroxyproline (Hyp), hyaluronic acid (HA), and laminin (LN). The lung index was determined by the wet and dry methods. The pathological changes in the lung tissue were observed by hematoxylin-eosin (HE) staining, and the degree of fibrosis was detected by Masson staining. The mRNA and protein levels of TGF-β1, p-Smad3, Smad3, α-smooth muscle actin (α-SMA), collagen type Ⅰ alpha 1 (Col1A1), and fibronectin were determined by PCR and Western blotting, respectively. ResultsCompared with the blank group, the model group showed alveolar septa thickening, obvious thickening of the basement membrane of pulmonary blood vessels, severe destruction of the alveolar structure, structural disarrangement of the lung parenchyma, and an increase in the proportion of inflammatory cell infiltration in the lung tissue, together with a large amount of blue collagen deposition and a large amount of collagen fibroplasia in the bronchial wall, vessel wall, interstitium, and alveolar wall, which indicated severe fibrosis. Bufei Tongbi decoction groups and the pirfenidone group showed lower fasting blood glucose level (P<0.05) and higher forced vital capacity (FVC), cytoplasmic dynein (Cydn), FEV0.3/FEV ratio, and lung index (P<0.05) than the model group. Moreover, these groups demonstrated alleviated lung fibrosis, elevated Hyp, HA, and LN levels, down-regulated mRNA levels of α-SMA, Col1A1, and fibronectin, and down-regulated protein levels of TGF-β1, Smad3, p-Smad3, α-SMA, Col1A1, and fibronectin (P<0.05). ConclusionBufei Tongbi decoction can inhibit pulmonary fibrosis in diabetic rats by inhibiting the TGF-β1/p-Smad3 signaling pathway.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.


Result Analysis
Print
Save
E-mail