1.Effects of polylactic acid-glycolic acid copolymer/lysine-grafted graphene oxide nanoparticle composite scaffolds on osteogenic differentiation of MC3T3 cells
Shuangqi YU ; Fan DING ; Song WAN ; Wei CHEN ; Xuejun ZHANG ; Dong CHEN ; Qiang LI ; Zuoli LIN
Chinese Journal of Tissue Engineering Research 2025;29(4):707-712
BACKGROUND:How to effectively promote bone regeneration and bone reconstruction after bone injury has always been a key issue in clinical bone repair research.The use of biological and degradable materials loaded with bioactive factors to treat bone defects has excellent application prospects in bone repair. OBJECTIVE:To investigate the effect of polylactic acid-glycolic acid copolymer(PLGA)composite scaffold modified by lysine-grafted graphene oxide nanoparticles(LGA-g-GO)on osteogenic differentiation and new bone formation. METHODS:PLGA was dissolved in dichloromethane and PLGA scaffold was prepared by solvent evaporation method.PLGA/GO composite scaffolds were prepared by dispersing graphene oxide uniformly in PLGA solution.LGA-g-GO nanoparticles were prepared by chemical grafting method,and the PLGA/LGA-g-GO composite scaffolds were constructed by blending LGA-g-GO nanoparticles at different mass ratios(1%,2%,and 3%)with PLGA.The micromorphology,hydrophilicity,and protein adsorption capacity of scaffolds of five groups were characterized.MC3T3 cells were inoculated on the surface of scaffolds of five groups to detect cell proliferation and osteogenic differentiation. RESULTS AND CONCLUSION:(1)The surface of PLGA scaffolds was smooth and flat under scanning electron microscope,while the surface of the other four scaffolds was rough.The surface roughness of the composite scaffolds increased with the increase of the addition of LGA-g-GO nanoparticles.The water contact angle of PLGA/LGA-g-GO(3%)composite scaffolds was lower than that of the other four groups(P<0.05).The protein adsorption capacity of PLGA/LGA-g-GO(1%,2%,and 3%)composite scaffolds was stronger than PLGA and PLGA/GO scaffolds(P<0.05).(2)CCK-8 assay showed that PLGA/LGA-g-GO(2%,3%)composite scaffold could promote the proliferation of MC3T3 cells.Alkaline phosphatase staining and alizarin red staining showed that the cell alkaline phosphatase activity in PLGA/LGA-g-GO(2%,3%)group was higher than that in the other three groups(P<0.05).The calcium deposition in the PLGA/GO and PLGA/LGA-g-GO(1%,2%,and 3%)groups was higher than that in the PLGA group(P<0.05).(3)In summary,PLGA/LGA-g-GO composite scaffold can promote the proliferation and osteogenic differentiation of osteoblasts,and is conducive to bone regeneration and bone reconstruction after bone injury.
3.Preparation of soluble microneedles of Aconitum brachypodum alkaloids
Yao CHEN ; Bi-Li DENG ; Jing WAN ; Na-Na DONG ; Xiao-Lan CHEN ; Yong-Ping ZHANG
Chinese Traditional Patent Medicine 2024;46(3):740-747
AIM To prepare the soluble microneedles of Aconitum brachypodum Diels alkaloids.METHODS Centrifugal molding method was adopted in the preparation of soluble microneedles.With chondroitin sulfate consumption,PVP K120 consumption and 40%ethanol consumption as influencing factors,piercing rate as an evaluation index,the formulation was optimized by Box-Behnken response surface method,after which the morphology,piercing performance,drug content and in vitro transdermal performance were investigated.RESULTS The optimal formulation was determined to be 123 mg for chondroitin sulfate consumption,298 mg for PVP K120 consumption,and 2.4 mL for 40%ethanol consumption,the piercing rate was 98.3%.The soluble microneedles were yellow and square patch with conoid needle,which could pierce aluminum foil and rat skin,along with the drug content of(0.94±0.025)mg.The soluble microneedle group demonstrated the accumulative permeability rate of 91.4%within 24 h,which was higher than that in the gel ointment group,and the permeability accorded with Higuchi equation.CONCLUSION The soluble microneedles of A.brachypodum alkaloids exhibit good mechanical strength,which can achieve effective transdermal delivery of drugs.
4.Bioequivalence test of metronidazole tablets in healthy human in China
Xiu-Qing PENG ; Cai-Hui GUO ; Ya-Li LIU ; Na ZHAO ; Hao-Jing SONG ; Wan-Jun BAI ; Zhan-Jun DONG
The Chinese Journal of Clinical Pharmacology 2024;40(13):1943-1947
Objective To evaluate the bioequivalence of metronidazole tablet and reference formulation in Chinese healthy subjects.Methods A single-dose,two-cycle,randomized,open,self-crossover trial was designed with 48 healthy subjects randomly assigned to fasting or postprandial group.For each group,a single oral dose of metronidazole tablet(200 mg)or a reference preparation(200 mg)per cycle were enrolled.The concentration of metronidazole in plasma was measured by high performance liquid chromatography tandem mass spectrometry(HPLC-MS/MS).The non-compartmental model was applied to calculate the pharmacokinetic parameters for bioequivalence analysis via SAS 9.3 software.Results The main pharmacokinetic parameters of test and reference metronidazole tablets in the fasting group were as follows,the Cmax were(4 855.00±1 383.97)and(4 799.13±1 195.32)ng·h·mL-1;the AUC0-t were(54 834.68±12 697.88)and(55 931.35±11 935.28)ng·h·mL-1;the AUC0-∞ were(56 778.09±13 937.76)and(57 922.83±13 260.54)ng·h·mL-1;the Tmax were respectively 1.17 and 1.00 h;t1/2 were(8.99±1.76)and(9.11±1.73)h,respectively.The ratio of the geometric mean and its 90%confidence intervals(CI)of Cmax,AUC0-t and AUC0-∞ were all within the equivalent interval of 80.00%-125.00%.As for postprandial conditions,the main pharmacokinetic parameters of test and reference metronidazole tablets were as follows,the Cmax were(4 057.08±655.08)and(4 044.17±773.98)ng·h·mL-1;the AUC0-t were(55 956.42±12 228.12)and(55 121.04±11 784.55)ng·h·mL-1;the AUC0-∞ were(58 212.83±13 820.00)and(57 350.38±13 229.46)ng·h·mL-1;the Tmax were 2.50 and 2.25 h;the t1/2 were(9.37±1.68)and(9.37±1.79)h,respectively.The ratio of the geometric mean and 90%CI of Cmax,AUC0-t and AUC0-∞ were all within the equivalent interval of 80.00%-125.00%.Conclusion The two preparations were bioequivalent to Chinese healthy adult volunteers under both fasting and fed conditions.
5.Clinical trial of sodium hyaluronate combined with recombinant human epidermal growth factor in the treatment of patients with dry eye after cataract operation
Jing-Sen QIU ; Xin-Hua WANG ; Wen-Chao DONG ; Wan-Li DIAO ; Xue-Jun XU
The Chinese Journal of Clinical Pharmacology 2024;40(18):2621-2625
Objective To evaluate the effect of sodium hyaluronate combined with recombinant human epidermal growth factor(rhEGF)in the treatment of dry eye after cataract surgery.Methods Patients with dry eye after cataract surgery were divided into treatment group and control group.The control group was treated with sodium hyaluronate eye drops via dropping into the conjunctival sac,a drop per dose,tid,for 4 weeks.On this basis,the treatment group was treated with rhEGF eye drops via dropping into the conjunctival sac,1-2 drops per dose,tid,for 4 weeks.The two groups were compared on overall clinical efficacy,dry eye symptoms before treatment and after 4 weeks of treatment.Tear-film breakup time(BUT),basic tear secretion test(schirmer Ⅰ test,SⅠT),corneal fluorescein staining(CFS)score,meibomian gland yield secretion score(MGYSS),and the levels of tear inflammatory factors were compared between two groups before treatment and after 4 weeks of treatment.The safety was evaluated.Results Finally,41 cases and 39 cases were included in the treatment group and the control group,respectively.After treatment,the total effective rates in the treatment group and the control group were 95.12%and 79.49%,with statistically significant difference(P<0.05).After 4 weeks of treatment,dry eye symptom scores of the treatment group and control group were 1.42±0.18 and 2.31±0.26;BUT were(11.89±1.26)and(10.46±1.27)s;SⅠT were(10.12±1.35)and(8.45±0.87)mm;CFS scores were 0.83±0.11 and 1.94±0.25;MGYSS scores were 10.85±1.17 and 12.43±1.56;interleukin-1β levels in tears were(35.26±3.53)and(74.12±7.55)ng·L-1;interleukin-6 levels were(8.35±0.86)and(12.41±12.56)pg·mL-1.Compared with the control group,the above indexes in the treatment group were statistically significant(all P<0.05).The incidence rates of adverse drug reactions in the treatment group and the control group were 12.20%and 10.26%,without statistically significant difference between the groups(P>0.05).Conclusion Sodium hyaluronate combined with rhEGF can significantly improve dry eye symptoms after cataract surgery,enhance the stability of tear film,reduce tear inflammatory factors,and protect the integrity of meibomian gland.
6.Salidroside Ameliorates Lung Injury Induced by PM2.5 by Regulating SIRT1-PGC-1α in Mice
Hong Xiao LI ; Mei Yu LIU ; Hui SHAN ; Feng Jin TAN ; Jian ZHOU ; Jin Yuan SONG ; Qi Si LI ; Chen LIU ; Qun Dong XU ; Li YU ; Wei Wan LI
Biomedical and Environmental Sciences 2024;37(4):367-376
Objective This study aimed to clarify the intervention effect of salidroside(SAL)on lung injury caused by PM2.5 in mice and illuminate the function of SIRT1-PGC-1ɑ axis. Methods Specific pathogen-free(SPF)grade male C57BL/6 mice were randomly assigned to the following groups:control group,SAL group,PM2.5 group,SAL+PM2.5 group.On the first day,SAL was given by gavage,and on the second day,PM2.5 suspension was given by intratracheal instillation.The whole experiment consist of a total of 10 cycles,lasting 20 days.At the end of treatment,blood samples and lung tissues were collected and analyzed.Observation of pathological changes in lung tissue using inverted microscopy and transmission electron microscopy.The expression of inflammatory,antioxidants,apoptosis,and SIRT1-PGC-1ɑ proteins were detected by Western blotting. Results Exposure to PM2.5 leads to obvious morphological and pathologica changes in the lung of mice.PM2.5 caused a decline in levels of antioxidant-related enzymes and protein expressions of HO-1,Nrf2,SOD2,SIRT1 and PGC-1ɑ,and an increase in the protein expressions of IL-6,IL-1β,Bax,caspase-9 and cleaved caspase-3.However,SAL reversed the aforementioned changes caused by PM2.5 by activating the SIRT1-PGC-1α pathway. Conclusion SAL can activate SIRT1-PGC-1ɑ to ameliorate PM2.5-induced lung injury.
7.Characterization and phylogenetic analysis of the complete chloroplast genome of Salvia apiana Jepson
Zhen-xi FANG ; Qian JI ; Jia-dong HU ; Wan-sheng CHEN ; Qing LI
Acta Pharmaceutica Sinica 2024;59(5):1484-1493
italic>Salvia apiana Jepson, commonly known as white sage, is a perennial sub-shrub of the
8.Determination of 19 components in Microctis Folium from different production areas based on UPLC-MS/MS
Min-you HE ; Li-wei WANG ; Lin LIU ; Po-yu ZHANG ; Jin-quan LAN ; Xin-ya WAN ; Zhen-yu LI ; Xiang-dong CHEN ; Dong-mei SUN
Acta Pharmaceutica Sinica 2024;59(5):1374-1381
The paper is to establish an UPLC-MS/MS method for the simultaneous determination of 19 components in Microctis Folium from different production areas. The 50% methanol was used as extraction solvent. The Agilent ZORBAX SB C18 (150 mm × 2.1 mm, 1.8 μm) column was used; mobile phase was acetonitrile - 0.1% acetic acid with gradient elution, flow rate was 0.3 mL·min-1, colume temperature was 30 ℃, and the injection volume was 2 μL; electrospray ionizaton source was used and detected in negative ion mode. The results showed that the established UPLC-MS/MS method could well separate the 19 components, and the methodological investigation results of 19 components were good. By means of orthogonal partial least squares discriminant analysis (OPLS-DA), 28 batches of Microctis Folium samples from different production areas can be divided into three categories, Guangdong, Guangxi and Hainan are each classified into one category, and 10 signature compounds which affecting the quality differences of different production areas were screened out. The established method is accurate, reliable, sensitive and reproducible. It can provide a basis for the establishment of the quality standard of Microctis Folium, as well as for safety and quality research.
9.Research on Electrochemical Chemical Oxygen Demand Sensor
Shan YUN ; Lei WANG ; Li-Guo WAN ; Zhen-Yu PENG ; Hong-Chang WANG ; Jun-Feng ZHAI ; Shao-Jun DONG
Chinese Journal of Analytical Chemistry 2024;52(9):1298-1306
An electrochemical chemical oxygen demand(COD)sensor was proposed based on a FTO/TiO2/PbO2 electrode and a thin-layer electrochemical cell.The FTO/TiO2/PbO2 electrode was characterized by X-ray photoelectronic spectroscopy(XPS),X-ray diffraction(XRD)spectroscopy and electrochemical technique,and the results indicated that the rapid decrease in the output signals of the electrochemical COD sensor could be attributed to oxidation of PbSO4 occurring on the surface of FTO/TiO2/PbO2 electrode.The PbO2 deposition time and concentration of Na2SO4 were further optimized and then the electrochemical COD sensor was challenged by real samples including laker water sample,river water sample and wastewater sample.The evolution trend of signals of the electrochemical COD sensor in response to lake and river water samples was identical with that obtained with the standard method(HJ/T399-2007,Water quality-determination of the chemical oxygen demand-fast digestion-spectrophotometric method).The electrochemical COD sensor exhibited significant increase in the signal intensity after the samples were switched from lake water to wastewater sample,and a mean value of 32.5 mg/L with relative standard deviation(RSD)of 6.8%were obtained after measuring 45 times the wastewater with COD value of 30 mg/L under a sampling interval of 400 s.The as-prepared electrochemical COD sensor possessed good promise in regular monitoring of COD,discharge of wastewater and industrial process control,with advantages such as a small sampling interval,mild reaction conditions and no requirement of toxic and harmful chemical reagents.
10.Meta-analysis of the diagnostic value of ultrasound, new ultrasound techniques, or CT alone or in combination for lymph node metastasis in thyroid cancer
Wei WEI ; Guanghan LI ; Jingfang DONG ; Yuxiang WAN ; Xiangzhu WANG ; Bo ZHANG
Chinese Journal of Ultrasonography 2024;33(6):525-537
Objective:To evaluate the practical value of ultrasound, ultrasound new technologies (ultrasound elastography, contrast enhanced ultrasound) and computed tomography (CT) examination alone or the combination of both of the four in the clinical diagnosis of lymph node metastasis of thyroid cancer by meta-analysis system.Methods:This study screened relevant literature on ultrasound, new ultrasound technologies, and CT in the diagnosis of lymph node metastasis of thyroid cancer by searching Chinese and English databases from January 2006 to August 2023. Two scholars independently assessed the quality of the literatures and scored them using the QUADAS scale. Then, the diagnostic ratio of single and combined examinations was analyzed by Meta-Disc software, and the heterogeneity test and meta-analysis were performed to calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic ratio, accuracy, and area under curve (AUC). Finally, the diagnostic efficacies of different diagnostic techniques and their combination in identifying lymph node metastasis of thyroid cancer were assessed by calculating OR and P values by two-by-two comparisons. Results:Sixty-nine diagnostic studies totaling 30, 666 lesions were finally included. The meta-analysis study showed that contrast enhanced ultrasound had the highest sensitivity[0.83(0.77-0.87)], ultrasound specificity was the highest [0.84(0.79-0.88)], the highest AUC was for contrast enhanced ultrasound (0.90), and contrast enhanced ultrasound and ultrasound elastography had high accuracies (0.81, 0.80, respectively) both of them were higher than those of ultrasound (0.77) and CT (0.69). Contrast enhanced ultrasound and ultrasound elastography were both more sensitive than CT, with statistically significant differences between them ( P<0.01); contrast enhanced ultrasound + ultrasound elastography had the highest accuracy, while ultrasound + contrast enhanced ultrasound and contrast enhanced ultrasound + ultrasound elastography were both more sensitive, with no statistically significant differences between them ( P>0.05), but the latter had the highest specificity [0.90(0.88-0.92)], which were statistically significantly different from each other ( P<0.05), ultrasound+ contrast enhanced ultrasound and contrast enhanced ultrasound+ ultrasound elastography had higher sensitivities than ultrasound+ CT, which were statistically different from each other ( P<0.05), and ultrasound+ CT had the lowest specificity [0.76(0.70-0.81)]. Conclusions:The diagnostic efficacy of thyroid cancer lymph node metastasis is highest with contrast enhanced ultrasound. The new ultrasound technique for diagnosing thyroid cancer lymph node metastasis has a higher diagnostic value than CT, and it can be used as a complementary examination to conventional ultrasound.When the two techniques are used in combination, contrast enhanced ultrasound + ultrasound elastography has the highest accuracy, contrast enhanced ultrasound + ultrasound elastography and ultrasound + contrast enhanced ultrasound both have high sensitivity and specificity, and the diagnostic performance of both is higher than that of ultrasound + ultrasound elastography and ultrasound + CT, and in actual clinical practice when ultrasound elastography combined with contrast enhanced ultrasound is limited in the examination, ultrasound combined with contrast enhanced ultrasound can effectively serve as an alternative means to provide a good diagnostic support.

Result Analysis
Print
Save
E-mail