1.Comparison of the Effectiveness of Three Lumbosacral Orthoses on Early Spine Surgery Patients: A Prospective Cohort Study
Soo Woong JANG ; Hee Seung YANG ; Young Bae KIM ; Joo Chul YANG ; Kyu Bok KANG ; Tae Wan KIM ; Kwan Ho PARK ; Kyung Soo JEON ; Hee Dong SHIN ; Ye Eun KIM ; Han Na CHO ; Yun Kyung LEE ; Young LEE ; Seul Bin Na LEE ; Dong Young AHN ; Woo Sob SIM ; Min JO ; Gyu Jik JO ; Dong Bum PARK ; Gwan Su PARK
Annals of Rehabilitation Medicine 2021;45(1):24-32
Objective:
To compare the convenience and effectiveness of the existing lumbosacral orthoses (LSO) (classic LSO and Cybertech) and a newly developed LSO (V-LSO) by analyzing postoperative data.
Methods:
This prospective cohort study was performed from May 2019 to November 2019 and enrolled and analyzed 88 patients with degenerative lumbar spine disease scheduled for elective lumbar surgery. Three types of LSO that were provided according to the time of patient registration were applied for 6 weeks. Patients were randomized into the classic LSO group (n=31), Cybertech group (n=26), and V-LSO group (n=31). All patients were assessed using the Oswestry Disability Index (ODI) preoperatively and underwent plain lumbar radiography (anteroposterior and lateral views) 10 days postoperatively. Lumbar lordosis (LS angle) and frontal imbalance were measured with and without LSO. At the sixth postoperative week, a follow-up assessment with the ODI and orthosis questionnaire was conducted.
Results:
No significant differences were found among the three groups in terms of the LS angle, frontal imbalance, ODI, and orthosis questionnaire results. When the change in the LS angle and frontal imbalance toward the reference value was defined as a positive change with and without LSO, the rate of positive change was significantly different in the V-LSO group (LS angle: 41.94% vs. 61.54% vs. 83.87%; p=0.003).
Conclusion
The newly developed LSO showed no difference regarding its effectiveness and compliance when compared with the existing LSO, but it was more effective in correcting lumbar lordosis.
2.Evaluating usability of and satisfaction with two types of dental CAD software
Seong Min KIM ; Wan Sun LEE ; Keunbada SON ; Kyu Bok LEE
Journal of Dental Rehabilitation and Applied Science 2019;35(1):11-19
PURPOSE: This study evaluated the usability of and satisfaction with two types of computer-aided design (CAD) software among users who had experience with dental implant CAD software and those who did not. MATERIALS AND METHODS: Dental technicians (n = 20) who had previous experience with dental implant CAD Software and students from the College of Dentistry (n = 12) who had never designed implant custom abutments were asked to evaluate two types of CAD Software, Exocad and Deltanine. In addition, the participants were asked to fill out a structured questionnaire (Section 1: Entering basic information and retrieving files; Section 2: Setting conditions before abutment design; Section 3: Setting abutment design; and Section 4: Overall satisfaction). For the statistical analysis of the collected data, Mann-Whitney U test was used (α = .05). RESULTS: The ease of design and satisfaction with the implant CAD Software, evaluated with respect to 21 statements divided into four Stages, were significantly higher for Exocad in both groups for Secion 1. For Sections 2 and 3, participants with experience evaluated Deltanine to be significantly better. For Section 4, both groups evaluated Exocad Software to be better. CONCLUSION: Overall, the Exocad Software was evaluated as having better usability and offering greater satisfaction. However, in terms of performance in the core of the design process, i.e. Sections 2 and 3, Deltanine was rated higher by the experienced users. Thus, if the user interface design parts are supplemented, Deltanine CAD Software could be put to a wider use in clinics.
Computer-Aided Design
;
Dental Implants
;
Dental Technicians
;
Dentistry
;
Humans
3.Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study
Mei Yang HUANG ; Keunbada SON ; Wan Sun LEE ; Kyu Bok LEE
The Journal of Korean Academy of Prosthodontics 2019;57(2):102-109
PURPOSE: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. MATERIALS AND METHODS: In this study, a single abutment, and a bridge abutment with missing first molar was fabricated and set as the reference model. The reference model was scanned with an industrial three-dimensional scanner and set as reference scan data. The reference model was scanned five times using the three intraoral scanners (CS3600, CS3500, and EZIS PO). This was set as the evaluation scan data. In the three-dimensional analysis (Geomagic control X), the divided abutment region was selected and analyzed to verify the scan accuracy of the abutment. Statistical analysis was performed using SPSS software (α = .05). The accuracy of intraoral scanners was compared using the Kruskal-Wallis test and post-test was performed using the Pairwise test. The accuracy difference between the single abutment model and the bridge abutment model was analyzed by the Mann-Whitney U test. RESULTS: The accuracy according to the intraoral scanner was significantly different (P < .05). The trueness of the single abutment model and the bridge abutment model showed a statistically significant difference and showed better trueness in the single abutment (P < .05). There was no significant difference in the precision (P = .616). CONCLUSION: As a result of comparing the accuracy of single and bridge abutments, the error of abutment scan increased with increasing scan area, and the accuracy of bridge abutment model was clinically acceptable in three types of intraoral scanners.
In Vitro Techniques
;
Molar
4.Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method
Yoo Geum JEONG ; Wan Sun LEE ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2018;10(3):245-251
PURPOSE: To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS: First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS: The RMS value (152±52 µm) of the model manufactured by the milling method was significantly higher than the RMS value (52±9 µm) of the model produced by the 3D printing method. CONCLUSION: The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.
Dental Models
;
Dental Prosthesis
;
Methods
;
Printing, Three-Dimensional
;
Prostheses and Implants
;
Tooth
5.Effect of repeated learning for two dental CAD software programs.
KeunBaDa SON ; Wan Sun LEE ; Kyu Bok LEE
Journal of Dental Rehabilitation and Applied Science 2017;33(2):88-96
PURPOSE: The purpose of this study is to assess the relationship between the time spent designing custom abutments and repeated learning using dental implant computer aided design (CAD) software. MATERIALS AND METHODS: The design of customized abutments was performed four stages using the 3DS CAD software and the EXO CAD software, and measured repeatedly three times by each stage. Learning effect by repetition was presented with the learning curve, and the significance of the reduction in the total time and the time at each stage spent on designing was evaluated using the Friedman test and the Wilcoxon signed rank test. The difference in the design time between groups was analyzed using the repeated measure two-way ANOVA. Statistical analysis was performed using the SPSS statistics software (P < 0.05). RESULTS: Repeated learning of the customized abutment design displayed a significant difference according to the number of repetition and the stage (P < 0.001). The difference in the time spent designing was found to be significant (P < 0.001), and that between the CAD software programs was also significant (P = 0.006). CONCLUSION: Repeated learning of CAD software shortened the time spent designing. While less design time on average was spent with the 3DS CAD than with the EXO CAD, the EXO CAD showed better results in terms of learning rate according to learning effect.
Computer-Aided Design
;
Dental Implants
;
Learning Curve
;
Learning*
6.Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
Wan Sun LEE ; Du Hyeong LEE ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2017;9(4):265-270
PURPOSE: This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS: The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS: The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) µm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) µm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION: The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
Crowns*
;
Dental Prosthesis
;
Methods
;
Printing, Three-Dimensional*
;
Silicon
;
Stainless Steel
7.A standardization model based on image recognition for performance evaluation of an oral scanner.
Sang Wan SEO ; Wan Sun LEE ; Jae Young BYUN ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2017;9(6):409-415
PURPOSE: Accurate information is essential in dentistry. The image information of missing teeth is used in optically based medical equipment in prosthodontic treatment. To evaluate oral scanners, the standardized model was examined from cases of image recognition errors of linear discriminant analysis (LDA), and a model that combines the variables with reference to ISO 12836:2015 was designed. MATERIALS AND METHODS: The basic model was fabricated by applying 4 factors to the tooth profile (chamfer, groove, curve, and square) and the bottom surface. Photo-type and video-type scanners were used to analyze 3D images after image capture. The scans were performed several times according to the prescribed sequence to distinguish the model from the one that did not form, and the results confirmed it to be the best. RESULTS: In the case of the initial basic model, a 3D shape could not be obtained by scanning even if several shots were taken. Subsequently, the recognition rate of the image was improved with every variable factor, and the difference depends on the tooth profile and the pattern of the floor surface. CONCLUSION: Based on the recognition error of the LDA, the recognition rate decreases when the model has a similar pattern. Therefore, to obtain the accurate 3D data, the difference of each class needs to be provided when developing a standardized model.
Dentistry
;
Tooth
8.A comparative study on the user satisfaction between two different piezoelectric engines
Hyun Mi LIM ; Kyu Bok LEE ; Wan Sun LEE ; So Young CHOI
Journal of Dental Rehabilitation and Applied Science 2017;33(4):269-277
PURPOSE: The aim of this study is to compare the performance of two piezoelectric engine systems by surveying satisfaction from dental clinicians. MATERIALS AND METHODS: Two piezoelectric systems were evaluated: TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). For this study, 20 dentists responded to the 11 questionnaires in which 5 point Likert-type scale was used. The two devices were operated for 10 seconds and measured 5 times to compare the maximum noise values. In heat emission test, the handpiece was operated for 3 minutes and heat was measured at three positions each. RESULTS: TRAUS XUS10 had higher satisfaction level on motor noise (P < 0.05). About function key and handpiece heat generation, PIEZOSURGERY touch showed higher satisfaction (P < 0.05) than TRAUS XUS10. The maximum noise level for each of the devices was confirmed to be 56.6 dB for the TRAUS XUS10 and 56.0 dB for PIEZOSURGERY touch. The two piezoelectric engines satisfied the safety standards with an operation temperature below 41℃ after having been operated for 3 minutes. CONCLUSION: Except for the function key and handpiece heat emission, TRAUS XUS10 has comparable performance with PIEZOSURGERY touch.
Dentists
;
Hot Temperature
;
Humans
;
Noise
;
Piezosurgery
9.Forkhead Transcription Factor FOXO1 Inhibits Angiogenesis in Gastric Cancer in Relation to SIRT1.
Sue Youn KIM ; Young San KO ; Jinju PARK ; Yiseul CHOI ; Jong Wan PARK ; Younghoon KIM ; Jung Soo PYO ; Young Bok YOO ; Jae Seon LEE ; Byung Lan LEE
Cancer Research and Treatment 2016;48(1):345-354
PURPOSE: We previously reported that forkhead transcription factors of the O class 1 (FOXO1) expression in gastric cancer (GC) was associated with angiogenesis-related molecules. However, there is little experimental evidence for the direct role of FOXO1 in GC. In the present study, we investigated the effect of FOXO1 on the tumorigenesis and angiogenesis in GC and its relationship with SIRT1. MATERIALS AND METHODS: Stable GC cell lines (SNU-638 and SNU-601) infected with a lentivirus containing FOXO1 shRNA were established for animal studies as well as cell culture experiments. We used xenograft tumors in nude mice to evaluate the effect of FOXO1 silencing on tumor growth and angiogenesis. In addition, we examined the association between FOXO1 and SIRT1 by immunohistochemical tissue array analysis of 471 human GC specimens and Western blot analysis of xenografted tumor tissues. RESULTS: In cell culture, FOXO1 silencing enhanced hypoxia inducible factor-1alpha (HIF-1alpha) expression and GC cell growth under hypoxic conditions, but not under normoxic conditions. The xenograft study showed that FOXO1 downregulation enhanced tumor growth, microvessel areas, HIF-1alpha activation and vascular endothelial growth factor (VEGF) expression. In addition, inactivated FOXO1 expression was associated with SIRT1 expression in human GC tissues and xenograft tumor tissues. CONCLUSION: Our results indicate that FOXO1 inhibits GC growth and angiogenesis under hypoxic conditions via inactivation of the HIF-1alpha-VEGF pathway, possibly in association with SIRT1. Thus, development of treatment modalities aiming at this pathway might be useful for treating GC.
Angiogenesis Modulating Agents
;
Animals
;
Anoxia
;
Blotting, Western
;
Carcinogenesis
;
Cell Culture Techniques
;
Cell Line
;
Down-Regulation
;
Forkhead Transcription Factors
;
Heterografts
;
Humans
;
Lentivirus
;
Mice
;
Mice, Nude
;
Microvessels
;
RNA, Small Interfering
;
Stomach Neoplasms*
;
Tissue Array Analysis
;
Transcription Factors*
;
Vascular Endothelial Growth Factor A
10.Pneumoretroperitoneum, Pneumomediastinum, Subcutaneous Emphysema After a Rectal Endoscopic Mucosal Resection.
Hee Cheul JUNG ; Hyun Jin KIM ; Sung Bok JI ; Jun Hyeong CHO ; Ji Hye KWAK ; Chang Min LEE ; Wan Soo KIM ; Jin Ju KIM ; Jae Min LEE ; Sang Su LEE
Annals of Coloproctology 2016;32(6):234-238
An endoscopic mucosal resection (EMR) is an effective and safe therapeutic technique for treating a patient with a laterally-spreading tumor (LST). Colonoscopic-procedure-related complications are noted to be about 2.8% worldwide, and a perforation is the most common. Most colon perforations cause pneumoperitoneum. However, a perforation within the retroperitoneal portion of the colon (rectum and some of sigmoid colon) may cause an extraperitoneal perforation, and the leaking free air may induce pneumoretroperitoneum, pneumomediastinum, and subcutaneous emphysema, depending on the amount of discharged air. Herein, we present the case of a patient with an extraperitoneal colon microperforation which manifested as pneumoretroperitoneum, pneumomediastinum, and subcutaneous emphysema after an EMR for a sigmoid LST, which was successfully treated with medical treatment and endoscopic clipping.
Colon
;
Colon, Sigmoid
;
Colonoscopy
;
Humans
;
Mediastinal Emphysema*
;
Pneumoperitoneum
;
Retropneumoperitoneum*
;
Subcutaneous Emphysema*

Result Analysis