1.Associations between indoor volatile organic compounds and nocturnal heart rate variability of young female adults: A panel study.
Xue Zhao JI ; Shan LIU ; Wan Zhou WANG ; Ye Tong ZHAO ; Lu Yi LI ; Wen Lou ZHANG ; Guo Feng SHEN ; Fu Rong DENG ; Xin Biao GUO
Journal of Peking University(Health Sciences) 2023;55(3):488-494
OBJECTIVE:
To investigate the association between short-term exposure to indoor total volatile organic compounds (TVOC) and nocturnal heart rate variability (HRV) among young female adults.
METHODS:
This panel study recruited 50 young females from one university in Beijing, China from December 2021 to April 2022. All the participants underwent two sequential visits. During each visit, real time indoor TVOC concentration was monitored using an indoor air quality detector. The real time levels of indoor temperature, relative humidity, noise, carbon dioxide and fine particulate matter were monitored using a temperature and humidity meter, a noise meter, a carbon dioxide meter and a particulate counter, respectively. HRV parameters were measured using a 12-lead Holter. Mixed-effects models were used to evaluate the association between the TVOC and HRV parameters and establish the exposure-response relationships, and two-pollutant models were applied to examine the robustness of the results.
RESULTS:
The mean age of the 50 female subjects was (22.5±2.3) years, and the mean body mass index was (20.4±1.9) kg/m2. During this study, the median (interquartile range) of indoor TVOC concentrations was 0.069 (0.046) mg/m3, the median (interquartile range) of indoor temperature, relative humidity, carbon dioxide concentration, noise level and fine particulate matter concentration were 24.3 (2.7) ℃, 38.5% (15.0%), 0.1% (0.1%), 52.7 (5.8) dB(A) and 10.3 (21.5) μg/m3, respectively. Short-term exposure to indoor TVOC was associated with significant changes in time-domain and frequency-domain HRV parameters, and the exposure metric for most HRV parameters with the most significant changes was 1 h-moving average. Along with a 0.01 mg/m3 increment in 1 h-moving average concentration of indoor TVOC, this study observed decreases of 1.89% (95%CI: -2.28%, -1.50%) in standard deviation of all normal to normal intervals (SDNN), 1.92% (95%CI: -2.32%, -1.51%) in standard deviation of average normal to normal intervals (SDANN), 0.64% (95%CI: -1.13%, -0.14%) in percentage of adjacent NN intervals differing by more than 50 ms (pNN50), 3.52% (95%CI: -4.30%, -2.74%) in total power (TP), 5.01% (95%CI: -6.21%, -3.79%) in very low frequency (VLF) power, and 4.36% (95%CI: -5.16%, -3.55%) in low frequency (LF) power. The exposure-response curves showed that indoor TVOC was negatively correlated with SDNN, SDANN, TP, and VLF when the concentration exceeded 0.1 mg/m3. The two-pollutant models indicated that the results were generally robust after controlling indoor noise and fine particulate matter.
CONCLUSION
Short-term exposure to indoor TVOC was associated with significant negative changes in nocturnal HRV of young women. This study provides an important scientific basis for relevant prevention and control measures.
Humans
;
Female
;
Adult
;
Young Adult
;
Air Pollutants/analysis*
;
Heart Rate/physiology*
;
Volatile Organic Compounds/analysis*
;
Carbon Dioxide
;
Particulate Matter/adverse effects*
;
Environmental Pollutants
2.Establishment of a fast discriminant model with electronic nose for Polygonati Rhizoma mildew based on odor variation.
Shu-Lin YU ; Jian-Ting GONG ; Li LI ; Jia-Li GUAN ; En-Ai ZHAI ; Shao-Qin OUYANG ; Hui-Qin ZOU ; Yong-Hong YAN
China Journal of Chinese Materia Medica 2023;48(7):1833-1839
The odor fingerprint of Pollygonati Rhizoma samples with different mildewing degrees was analyzed and the relationship between the odor variation and the mildewing degree was explored. A fast discriminant model was established according to the response intensity of electronic nose. The α-FOX3000 electronic nose was applied to analyze the odor fingerprint of Pollygonati Rhizoma samples with different mildewing degrees and the radar map was used to analyze the main contributors among the volatile organic compounds. The feature data were processed and analyzed by partial least squares discriminant analysis(PLS-DA), K-nearest neighbor(KNN), sequential minimal optimization(SMO), random forest(RF) and naive Bayes(NB), respectively. According to the radar map of the electronic nose, the response values of three sensors, namely T70/2, T30/1, and P10/2, increased with the mildewing, indicating that the Pollygonati Rhizoma produced alkanes and aromatic compounds after the mildewing. According to PLS-DA model, Pollygonati Rhizoma samples of three mildewing degrees could be well distinguished in three areas. Afterwards, the variable importance analysis of the sensors was carried out and then five sensors that contributed a lot to the classification were screened out: T70/2, T30/1, PA/2, P10/1 and P40/1. The classification accuracy of all the four models(KNN, SMO, RF, and NB) was above 90%, and KNN was most accurate(accuracy: 97.2%). Different volatile organic compounds were produced after the mildewing of Pollygonati Rhizoma, and they could be detected by electronic nose, which laid a foundation for the establishment of a rapid discrimination model for mildewed Pollygonati Rhizoma. This paper shed lights on further research on change pattern and quick detection of volatile organic compounds in moldy Chinese herbal medicines.
Electronic Nose
;
Odorants/analysis*
;
Volatile Organic Compounds/analysis*
;
Bayes Theorem
;
Drugs, Chinese Herbal/analysis*
;
Discriminant Analysis
3.Analysis of volatile organic compounds in exhaled breath after radiotherapy.
Dianlong GE ; Xue ZOU ; Yajing CHU ; Jijuan ZHOU ; Wei XU ; Yue LIU ; Qiangling ZHANG ; Yan LU ; Lei XIA ; Aiyue LI ; Chaoqun HUANG ; Pei WANG ; Chengyin SHEN ; Yannan CHU
Journal of Zhejiang University. Science. B 2022;23(2):153-157
Radiotherapy uses high-energy X-rays or other particles to destroy cancer cells and medical practitioners have used this approach extensively for cancer treatment (Hachadorian et al., 2020). However, it is accompanied by risks because it seriously harms normal cells while killing cancer cells. The side effects can lower cancer patients' quality of life and are very unpredictable due to individual differences (Bentzen, 2006). Therefore, it is essential to assess a patient's body damage after radiotherapy to formulate an individualized recovery treatment plan. Exhaled volatile organic compounds (VOCs) can be changed by radiotherapy and thus used for medical diagnosis (Vaks et al., 2012). During treatment, high-energy X-rays can induce apoptosis; meanwhile, cell membranes are damaged due to lipid peroxidation, converting unsaturated fatty acids into volatile metabolites (Losada-Barreiro and Bravo-Díaz, 2017). At the same time, radiotherapy oxidizes water, resulting in reactive oxygen species (ROS) that can increase the epithelial permeability of pulmonary alveoli, enabling the respiratory system to exhale volatile metabolites (Davidovich et al., 2013; Popa et al., 2020). These exhaled VOCs can be used to monitor body damage caused by radiotherapy.
Breath Tests/methods*
;
Exhalation
;
Humans
;
Quality of Life
;
Respiratory System/chemistry*
;
Volatile Organic Compounds/analysis*
4.Effects of different field processing methods on volatile components of Chuanxiong Rhizoma: an exploration based on headspace gas chromatography-mass spectrometry.
Yi-Na TANG ; Jun-Xia GUO ; Qing-Miao LI ; Jin-Hai YI
China Journal of Chinese Materia Medica 2022;47(3):676-683
The volatile oil of Chuanxiong Rhizoma(CX) is known as an effective fraction. In order to seek a suitable method for processing CX and its decoction pieces, this study selected 16 volatile components as indices to investigate how different processing methods such as washing/without washing, sun-drying, baking, oven-drying and far-infrared drying at different temperatures affected the quality of CX and its decoction pieces(fresh CX was partially dried, cut into pieces, and then dried) by headspace gas chromatography-mass spectrometry(GC-MS), cluster analysis, principal component analysis and comprehensive weighted scoring. The results showed that the rapid washing before processing did not deteriorate the volatile components of CX. Considering the practical condition of production area, oven-drying was believed to be more suitable than sun-drying, baking, and far-infrared drying. The CX decoction pieces with a thickness of 0.3-0.4 cm were recommended to be oven-dried at 50 ℃. The integrated processing(partial drying, cutting into pieces, and drying) did not cause a significant loss of volatile components. For the fresh CX, the oven-drying at 60 ℃ is preferred. The temperature should not exceed 60 ℃, and drying below 60 ℃ will prolong the processing time, which will produce an unfavorable effect on volatile components. This study has provided the scientific evidence for field processing of CX, which is conducive to realizing the normalization and standardization of CX processing in the production area and stabilizing the quality of CX and its decoction pieces.
Desiccation
;
Gas Chromatography-Mass Spectrometry/methods*
;
Oils, Volatile
;
Principal Component Analysis
;
Rhizome/chemistry*
;
Volatile Organic Compounds/analysis*
5.Comparison of odor and quality of Galli Gigerii Endothelium Corneum derived from domestic chickens and broilers.
Wei HUANG ; Lu-Meng CHEN ; Hao-Zhou HUANG ; Ya-Nan HE ; Xiao-Ming BAO ; Jing YANG ; Jun-Zhi LIN ; Peng TAN ; Li HAN ; Run-Chun XU ; Ding-Kun ZHANG
China Journal of Chinese Materia Medica 2022;47(20):5434-5442
Galli Gigerii Endothelium Corneum(GGEC) is commonly used for the clinical treatment of indigestion, vomiting, diarrhea, and infantile malnutrition with accumulation. In recent decades, omnivorous domestic chickens, the original source of GGEC, has been replaced by broilers, which may lead to significant changes in the quality of the yielding GGEC. Through subjective and objective sensory evaluation, biological evaluation, and chemical analysis, this study compared the odor and quality between GGEC derived from domestic chickens and that from broilers. The odor intensity between them was compared by odor profile analysis and it was found that the fishy odor of GGEC derived from domestic chickens was significantly weaker than that of GGEC from broilers. Headspace-solid phase microextraction-gas chromatography-triple quadrupole tandem mass spectrometry(HS-SPME/GC-QQQ-MS/MS) suggested that the overall odor-causing chemicals were consistent with the fishy odor-causing chemicals. According to the odor activity va-lue and the orthogonal partial least squares discriminant analysis(OPLS-DA) result, dimethyl trisulfide, 2-methoxy-3-isobutylpyrazine, and 2-methylisoborneol were responsible for the fishy odor(OAV≥1) and the content of fishy odor-causing chemicals in GGEC derived from broilers was 1.12-2.13 folds that in GGEC from domestic chickens. The average pepsin potency in GGEC derived from broilers was 15.679 U·mg~(-1), and the corresponding figure for the medicinal from domestic chickens was 26.529 U·mg~(-1). The results of pre-column derivatization reverse-phase high-performance liquid chromatography(RP-HPLC) assay showed that the content of total amino acids and digestion-promoting amino acids in domestic chickens-derived GGEC was 1.12 times and 1.15 times that in GGEC from broilers, and the bitter amino acid content was 1.21 times folds that of the latter. In conclusion, GGEC derived from domestic chickens had weaker fishy odor, stronger enzyme activity, higher content of digestion-promoting amino acids, and stronger bitter taste than GGEC from broilers. This study lays a scientific basis for studying the quality variation of GGEC and provides a method for identifying high-quality GGEC. Therefore, it is of great significance for the development and cultivation of GGEC as both food and medicine and breeding of corresponding varieties.
Animals
;
Odorants/analysis*
;
Chickens
;
Gas Chromatography-Mass Spectrometry/methods*
;
Tandem Mass Spectrometry
;
Solid Phase Microextraction
;
Amino Acids
;
Endothelium/chemistry*
;
Volatile Organic Compounds/analysis*
6.Rapid determination of 30 volatile organic compounds in workplace air by gas chromatography.
Gang LI ; Meng Yue QIAN ; Jie DUAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(3):222-226
Objective: To establish a method for rapid detection of DB-WAX capillary column and determination of the workplace air in 30 kinds of volatile organic pollutants. Methods: In August 2020, N-pentane, n-hexane, methylcyclohexane, octane, Acetone, ethyl acetate, butanone, benzene, 3-pentanone, trichloroethylene, tetrachloroethylene, toluene, butyl acetate, 2-hexanone, Isoamyl acetate, ethylbenzene, p-xylene, m-xylene, amyl acetate, o-xylene, chlorobenzene, styrene, cyclohexanone, P-chlorotoluene, bromobenzene, M-dichlorobenzene, p-dichlorobenzene, O-dichlorobenzene, o-Chlorotoluene, 1, 2 , 4-trichlorobenzene of 30 kinds of substances in air were collected by activated carbon tube. After analysis by carbon disulfide, the analytical solution was analyzed by DB-WAX column and determined by FID detector. Results: The above 30 kinds of volatile organic pollutants had good separation effect, the correlation coefficient of the standard curve was above 0.999, the relative standard deviation was 0.1%-3.2%, the desorption efficiency was 77.0%-117.1% , the lower limit of quantitation was 0.33-5.33 μg/ml, and the lowest quantitation concentration was 0.22-3.55 mg/m(3), the recoveries ranged was 95.4%-104.9%. Conclusion: The method can effectively separate and accurately determine 30 volatile organic compounds in these workplaces, and the method is simple and quick.
Air Pollutants, Occupational/analysis*
;
Benzene/analysis*
;
Chromatography, Gas
;
Volatile Organic Compounds/analysis*
;
Workplace
7.High-speed identification of odor changes and substance basis of Myristicae Semen mildew by electronic nose and HS-GC-MS.
Hui-Xuan TIAN ; Rui-Qi YANG ; Hui-Qin ZOU ; Xing-Yu GUO ; Wei-Feng HONG ; Yue-Bao YAO ; Yong LIU ; Yong-Hong YAN
China Journal of Chinese Materia Medica 2021;46(22):5853-5860
This study adopted headspace-gas chromatography-mass spectrometry(HS-GC-MS) and electronic nose to detect volatile components from Myristicae Semen samples with varying degrees of mildew, aiming at rapidly identifying odor changes and substance basis of Myristicae Semen mildew. The experimental data were analyzed by electronic nose and principal component analysis(PCA). The results showed that Myristicae Semen samples were divided into the following three categories by electronic nose and PCA: mildew-free samples, slightly mildewy samples, and mildewy samples. Myristicae Semen samples with different degrees of mildew greatly varied in volatile components. The volatile components in the samples were qualitatively and quantitatively detected by HS-GC-MS, and 59 compounds were obtained. There were significant differences in the composition and content in Myristicae Semen samples with different degrees of mildew. The PCA results were the same as those by electronic nose. Among them, 3-crene, D-limonene, and other terpenes were important indicators for the identification of mildew. Bicyclo[3.1.0]hexane, 4-methylene-1-(1-methylethyl)-, terpinen-4-ol, and other alcohols were key substances to distinguish the degree of mildew. In the later stage of mildew, Myristicae Semen produced a small amount of hydroxyl and aldehyde compounds such as acetaldehyde, 2-methyl-propionaldehyde, 2-methyl-butyraldehyde, and formic acid, which were deduced as the material basis of the mildew. The results are expected to provide a basis for the rapid identification of Myristicae Semen with different degrees of mildew, odor changes, and the substance basis of mildew.
Electronic Nose
;
Gas Chromatography-Mass Spectrometry
;
Odorants/analysis*
;
Semen/chemistry*
;
Solid Phase Microextraction
;
Volatile Organic Compounds/analysis*
8.Advances on Collection and Analysis of Volatile Organic Compounds in the Diagnosis of Lung Cancer.
Ling GUO ; Hong WU ; Qiang LI ; Chuan XU ; Yuyang LIU
Chinese Journal of Lung Cancer 2021;24(11):796-803
Lung cancer is a leading cause of cancer-related morbidity and mortality globally, which is the biggest menace to the health and life of the population. Screening and early detection of lung cancer are effective in reducing its mortality, and the measurement of volatile organic compounds (VOCs) has become a promising clinical means for early detection, course detection and prognosis management of lung cancer, with advantages of rapid speed, non-invasiveness and convenience. Now, a variety of VOCs collection ways and analysis methods have emerged at home and abroad. This report summarized three aspects, including VOCs collection, multiple methods of analysis and progress in the diagnosis and treatment of lung cancer. At last, we discussed the limitations and prospects of VOCs analysis.
.
Breath Tests
;
Early Detection of Cancer
;
Humans
;
Lung Neoplasms/diagnosis*
;
Volatile Organic Compounds
9.Identification of Volatile Organic Compounds Used to Diagnose and Evaluate Acute Promyelocyte Leukemia.
Hong-Xia TANG ; Zhi-Qiang LIU ; Ji-Fei DAI ; Yan LU ; Hai-Long XIA
Journal of Experimental Hematology 2020;28(6):1848-1852
OBJECTIVE:
To analyze the characteristics of volatile organic compounds (VOCs) in expiratory air components of patients with acute promyelocytic leukemia (APL), and assess the feasibility of VOCs for the diagnosis and prognostic evaluation of APL.
METHODS:
The VOCs exhaled from the patients with APL and healthy volunteers should be analyzed with SPME-GC/MS, and compared between newly-diagnosed group, relapse group, remission group, and healthy group with Wilcoxon/Kruskal-Wallis one-way analysis of variance and Dunn-Bonferroni test.
RESULTS:
Dimethyl sulfide, toluene, and dodecane obtained of newly-diagnosed APL patients were significantly higher, while ethanol, n-hexanal, and benzaldehyde were significantly lower than those of healthy people (P<0.05). Compared with the newly-diagnosed group, dimethylsulfide, toluene, and dodecane of the remission group significantly decreased, while ethanol, n-hexanal, and benzaldehyde significantly increased (P<0.05), which was just opposite from the relapse group.
CONCLUSION
Dimethyl sulfide, toluene, dodecane, ethanol, n-hexanal, and benzaldehyde can be used as biomarkers for the diagnosis and prognosis assessment of APL patients.
Exhalation
;
Gas Chromatography-Mass Spectrometry
;
Granulocyte Precursor Cells
;
Humans
;
Leukemia, Promyelocytic, Acute/diagnosis*
;
Volatile Organic Compounds/analysis*
10.Analysis of volatile organic compounds (VOCs) fingerprint of raw and honey-fried licorice based on headspace-gas-chromatography ion-mobility spectrometry (HS-GC-IMS).
Qian ZHOU ; Yan-Peng DAI ; Wei GUO ; Ping WANG ; Dian-Hua SHI
China Journal of Chinese Materia Medica 2020;45(16):3857-3862
Licorice is one of the most commonly used traditional Chinese medicine. In clinic, raw licorice and honey-fried licorice are used in medicines, with the main effects in clearing away heat and detoxifying, moistening lungs and removing phlegm. Honey-fried licorice has effects in nourishing the spleen and stomach and replenishing Qi and pulse. Because traditional Chinese medicine exerts the effects through multiple components and multiple targets, the index components used in the quality evaluation of licorice are often difficult to reflect their real quality. In addition, most of studies for the quality standards have shown that honey-fried licorice are the same as licorice, with a lack of quality evaluation standards that can demonstrate their processing characteristics. The quality of medicine is directly related to its clinical efficacy, so it is necessary to establish a more effective quality control method. Licorice has a beany smell, which is one of the main quality identification characteristics. In this study, by taking advantage of the odor characteristics, a headspace-gas chromatography-ion migration mass spectrometry technology was used to establish a quality evaluation method. A total of 76 volatile components were identified. Through the dynamic principal component analysis, 7 kinds of volatile substances in raw licorice and 13 kinds of volatile substances in honey-fried licorice were statistically obtained, and could be taken as index components for the quality evaluation of raw and honey-fried licorice, respectively. This study could help realize the combination and unification of modern detection and traditional quality evaluation methods, and make a more realistic evaluation for the quality of licorice.
Gas Chromatography-Mass Spectrometry
;
Glycyrrhiza
;
Honey
;
analysis
;
Ion Mobility Spectrometry
;
Volatile Organic Compounds
;
analysis

Result Analysis
Print
Save