1.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
2.Comparison on Performance of Quantitative Ultrasound and Dual-Energy X-ray Absorptiometry in Evaluating Bone Health of Adults Aged 18-40 Years.
Yu-Xian KUANG ; Hong CHENG ; Yi-Ying ZHENG ; Wei-Ye CHEN ; Zhen-Xin MA ; Gao-Yong ZOU ; Ding ZENG ; Jie MI ; Li LIU
Acta Academiae Medicinae Sinicae 2023;45(5):737-742
Objective To compare the consistency of quantitative ultrasound(QUS)and dual-energy X-ray absorptiometry(DXA)in measuring bone mineral density(BMD)of adults aged 18-40 years in Guangzhou and evaluate the diagnostic value of QUS for identifying low bone mass.Methods DXA was employed to measure the BMD and QUS to measure the speed of sound(SOS)in 731 participants.The Bland-Altman analysis was performed to evaluate the consistency of Z scores between SOS and BMD.With the BMD Z ≤-2.00 as the diagnostic criterion for low bone mass,the receiver operating characteristics curve of QUS was established,and the area under the curve(AUC)and the sensitivity,specificity,and correct diagnostic index for the optimal cut-off of SOS Z score were calculated.Results The results of Bland-Altman analysis showed that the mean differences in the Z scores of SOS and BMD in males and females were 1.27(-0.94 to 3.47)and 0.93(-1.33 to 3.18),respectively.The AUC of SOS Z score in the diagnosis of low bone mass in males and females was 0.734(95%CI=0.380-0.788)and 0.679(95%CI=0.625-0.732),respectively.In males,the optimal cut-off of SOS Z score for low bone mass was -0.35,with the sensitivity,specificity,and correct diagnostic index of 64.1%,68.6%,and 0.327,respectively.In females,the optimal cut-off value of SOS Z scores for low bone mass was -1.14,with the sensitivity,specificity,and correct index of 73.9%,54.8%,and 0.285,respectively.Conclusion QUS and DXA show poor consistency in the diagnosis of BMD in the adults aged 18-40 years in Guangzhou,while QUS demonstrates an acceptable value in identifying low bone mass.
Male
;
Female
;
Adult
;
Humans
;
Absorptiometry, Photon/methods*
;
Bone Density
;
Ultrasonography
;
Bone and Bones
;
ROC Curve
;
Sensitivity and Specificity
3.Effect of Calcification on the Ultrasound-Guided Radiofrequency Ablation of Papillary Thyroid Carcinoma.
Yi-Ming LI ; Lin YAN ; Jing XIAO ; Ming-Bo ZHANG ; Yu-Kun LUO
Acta Academiae Medicinae Sinicae 2023;45(5):803-808
Objective To investigate the effect of calcification on the ultrasound-guided radiofrequency ablation(RFA)of papillary thyroid carcinoma(PTC).Methods We retrospectively analyzed the preoperative and follow-up data of 164 patients(182 nodules)with PTC treated by percutaneous ultrasound-guided RFA in the First Medical Center of Chinese PLA General Hospital from January 1,2018 to December 31,2021.The tumor status 12 months after RFA was taken as the endpoint event.The univariate Logistic regression analysis was employed to predict the influencing factors of incomplete ablation.The factors were then included in the multivariate Logistic regression analysis for prediction of the independent risk factors of incomplete ablation.Results The maximum nodule diameter(OR=1.16,95%CI=1.04-1.29,P=0.009)and calcification ratio >2/3(OR=19.27,95%CI=4.02-92.28,P<0.001)were the factors influencing the disappearance of lesion 12 months after RFA.Conclusions PTC with calcification can be treated with ultrasound-guided RFA.In the case of calcification ratio ≤ 2/3,this therapy demonstrates the effect equivalent to that of no calcification.
Humans
;
Thyroid Cancer, Papillary/surgery*
;
Retrospective Studies
;
Neoplasm Recurrence, Local
;
Radiofrequency Ablation/methods*
;
Calcinosis
;
Thyroid Neoplasms/pathology*
;
Ultrasonography, Interventional
4.Research Progress in the Application of Ultrasound-Guided Robot in Minimally Invasive Surgery.
Acta Academiae Medicinae Sinicae 2023;45(5):853-858
With the continuous advances in modern medical technology and equipment,minimally invasive surgery (MIS) is widely applied in clinical practice.Ultrasound (US) as a real-time,portable,and radiation-free medical imaging method can be used for the intraoperative guidance in MIS to ensure safe and effective surgery.However,the physical characteristics of conventional US fail to display some tissue structures of the human body due to the existence of gas and bone.US-based navigation can make up for the deficiencies by advanced imaging technologies including spatial orientation,image reconstruction,and multi-modality image fusion,being real-time,accurate,and radiation-free.Therefore,US-guided robots can achieve safe,effective,and minimally invasive operation in MIS.This paper reviews the studies of US-guided robots in MIS and prospects the development of this field.
Humans
;
Robotics/methods*
;
Minimally Invasive Surgical Procedures/methods*
;
Ultrasonography
;
Spinal Fusion/methods*
;
Ultrasonography, Interventional/methods*
5.Diagnostic Value of American Thyroid Association Guidelines,American College of Radiology Thyroid Imaging Reporting and Data System,and Chinese Thyroid Imaging Reporting and Data System Alone and Combined With BRAFV600E Mutation in Atypia of Undetermined Significance/Follicular Lesion of Undetermined Significance.
Yu LIN ; Yu-Kun LUO ; Jie LI ; Xiu-Yun REN ; Hong-Wei WANG
Acta Academiae Medicinae Sinicae 2023;45(6):921-928
Objective To explore the diagnostic efficacy of American Thyroid Association(ATA)guidelines,American College of Radiology Thyroid Imaging Report and Data System(ACR-TIRADS),and Chinese Thyroid Imaging Reporting and Data System(C-TIRADS)alone and combined with BRAFV600E mutation in atypia of undetermined significance/follicular lesion of undetermined significance(AUS/FLUS).Methods A total of 138 patients who underwent ultrasound-guided fine needle aspiration(FNA)in the Chinese PLA General Hospital from January 2020 to May 2023 were selected.The clinicopathological and ultrasound characteristics were retrospectively analyzed for each nodule.Each nodule underwent preoperative BRAFV600E mutation testing and was diagnosed according to the ATA guidelines,ACR-TIRADS,and C-TIRADS.The diagnostic efficacy of ATA guidelines,ACR-TIRADS,and C-TIRADS alone and combined with BRAFV600E mutation was assessed based on the results of histopathological diagnosis.Results The 138 AUS/FLUS thyroid nodules included 45(32.6%)benign ones and 93(67.4%)malignant ones.The patient age(t=1.444,P=0.151),gender(χ2=0.259,P=0.611),and location of nodules(χ2=2.055,P=0.358)had no statistical significance for the differentiation between benign and malignant nodules,while nodule size(Z=2.500,P=0.012),echo(χ2=14.693,P<0.001),composition(χ2=17.075,P<0.001),aspect ratio ≥1(χ2=9.477,P=0.002),and microcalcification(χ2=6.892,P=0.009)were of significance for the differentiation.When applied alone,BRAFV600E mutation showed high specificity(95.56%)and positive predictive value(95.65%).Among the three ultrasound grading systems,ACR-TIRADS had the highest sensitivity(χ2=37.923,P<0.001;χ2=40.462,P<0.001)and accuracy(χ2=81.595,P<0.001;χ2=76.912,P<0.001),while C-TIRADS had the highest specificity(χ2=11.746,P<0.001;χ2=21.235,P<0.001).However,the three systems showed no statistically significant difference in the diagnostic efficiency when applied alone(Z=1.177,P=0.239;Z=0.213,P=0.831;Z=1.016,P=0.310).The combination of BRAFV600E mutation with ACR-TIRADS or C-TIRADS improved the diagnostic efficacy of BRAFV600E mutation in distinguishing the benign and malignant AUS/FLUS nodules(Z=2.107,P=0.035;Z=2.752,P=0.006).The combination of ATA guidelines with BRAFV600E mutation increased the diagnostic accuracy of BRAFV600E mutation(χ2=20.679,P<0.001),while it had no statistically significant difference in distinguishing the benign and malignant AUS/FLUS nodules(Z=1.321,P=0.186).The combination of ATA guidelines,ACR-TIRADS,or C-TIRADS with BRAFV600E mutation improved the diagnostic efficacy of ultrasound grading systems for AUS/FLUS nodules(Z=2.770,P=0.006;Z=2.770,P=0.006;Z=2.890,P=0.004).Specifically,ACR-TIRADS combined with BRAFV600E mutation showed the highest sensitivity(χ2=4.712,P=0.030;χ2=4.712,P=0.030),while C-TIRADS combined with BRAFV600E mutation showed the highest accuracy(χ2=77.627,P<0.001;χ2=85.827,P<0.001).However,there were no statistically significant differences in diagnostic performance between the combinations(Z=1.276,P=0.202;Z=0.808,P=0.419;Z=1.615,P=0.106).Conclusion ATA guidelines,ACR-TIRADS,and C-TIRADS combined with BRAFV600E mutation can improve the diagnostic efficacy of BRAFV600E mutation or ultrasound grading system alone in AUS/FLUS nodules,which can facilitate the further management and treatment of such patients.
Humans
;
United States
;
Infant
;
Thyroid Neoplasms/genetics*
;
Proto-Oncogene Proteins B-raf/genetics*
;
Adenocarcinoma, Follicular/pathology*
;
Retrospective Studies
;
Data Systems
;
Thyroid Nodule/genetics*
;
Ultrasonography/methods*
;
Mutation
;
China
;
Radiology
6.Influencing Factors of Bethesda Ⅲ Results in Fine-Needle Aspiration Biopsy of Thyroid Nodules.
Jian LIU ; Shang-Hong XIE ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(6):929-933
Objective To investigate the influencing factors of Bethesda Ⅲ results in fine-needle aspiration biopsy of thyroid nodules.Methods A total of 300 thyroid nodules with cytological diagnosis results were analyzed retrospectively,including 100 Bethesda Ⅲ nodules and 50 nodules of Bethesda Ⅱ,Ⅳ,Ⅴ,and Ⅵ categories,respectively.Univariate analysis and Logistic regression analysis were performed on the clinical data of patients and the ultrasound signs of thyroid nodules to clarify the factors influencing the diagnosis of Bethesda Ⅲ nodules.Results Univariate analysis showed that Bethesda Ⅲ nodules were mostly adjacent to the capsule(P<0.001),with no blood flow in the color Doppler assessment(P=0.011)and lack of blood supply(P=0.033)and maximum diameter ≤0.9 cm(P=0.038)as revealed by the contrast-enhanced ultrasound.Logistic regression showed that the position close to the capsule(OR=5.110,95%CI=2.153-12.130,P<0.001)and color Doppler without blood flow signal(OR=3.015,95%CI=1.094-8.311,P=0.033)were independent risk factors for the diagnosis of Bethesda Ⅲ nodules.Conclusions The puncture difficulty caused by the dangerous position of thyroid nodules close to the capsule and the aspiration difficulty caused by the absence of blood flow signal in color Doppler are the main factors influencing the diagnosis of Bethesda Ⅲ nodules.Therefore,corresponding avoidance measures should be taken during the aspiration process to reduce the diagnosis results of Bethesda Ⅲ nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Thyroid Neoplasms/diagnosis*
;
Biopsy, Fine-Needle/methods*
;
Retrospective Studies
;
Ultrasonography/methods*
7.Review on ultrasonographic diagnosis of thyroid diseases based on deep learning.
Fengyuan QI ; Min QIU ; Guohui WEI
Journal of Biomedical Engineering 2023;40(5):1027-1032
In recent years, the incidence of thyroid diseases has increased significantly and ultrasound examination is the first choice for the diagnosis of thyroid diseases. At the same time, the level of medical image analysis based on deep learning has been rapidly improved. Ultrasonic image analysis has made a series of milestone breakthroughs, and deep learning algorithms have shown strong performance in the field of medical image segmentation and classification. This article first elaborates on the application of deep learning algorithms in thyroid ultrasound image segmentation, feature extraction, and classification differentiation. Secondly, it summarizes the algorithms for deep learning processing multimodal ultrasound images. Finally, it points out the problems in thyroid ultrasound image diagnosis at the current stage and looks forward to future development directions. This study can promote the application of deep learning in clinical ultrasound image diagnosis of thyroid, and provide reference for doctors to diagnose thyroid disease.
Humans
;
Algorithms
;
Deep Learning
;
Image Processing, Computer-Assisted/methods*
;
Thyroid Diseases/diagnostic imaging*
;
Ultrasonography
8.Experimental study on high-frequency subharmonic scattering characteristics of ultrasound contrast agent microbubbles under low ambient pressure.
Huimin LU ; Yun WANG ; Laixin HUANG ; Gang XU ; Juan ZHOU ; Wenkui YU ; Fei LI
Journal of Biomedical Engineering 2023;40(6):1209-1216
Correlation between nonlinear subharmonic scattering of ultrasound contrast agent microbubbles and ambient pressure is expected to be used for local brain tissue pressure monitoring. Although high-frequency ultrasound has achieved high-resolution imaging of intracranial microvessels, the research on high-frequency subharmonic scattering characteristics of microbubbles is insufficient at present, which restricts the research progress of estimating local brain tissue pressure based on high-frequency subharmonic scattering of microbubbles. Therefore, under the excitation of 10 MHz high-frequency ultrasound, the effects of different acoustic pressures and ambient pressures on the high-frequency subharmonic scattering characteristics of three different ultrasound contrast agents including SonoVue, Sonazoid and Huashengxian were investigated in this in vitro study. Results showed that the subharmonic scattering amplitudes of the three microbubbles increased with the increase of ambient pressure at the peak negative acoustic pressures of 696, 766 and 817 kPa, and there was a favorable linear correlation between subharmonic amplitude and ambient pressure. Under the above three acoustic pressures, the highest correlation coefficient of SonoVue was 0.948 ( P = 0.03), the highest sensitivity of pressure measurement was 0.248 dB/mm Hg and the minimum root mean square error (RMSE) was 2.64 mm Hg. Sonazoid's highest correlation coefficient was 0.982 ( P < 0.01), the highest sensitivity of pressure measurement was 0.052 dB/mm Hg and the minimum RMSE was 1.51 mm Hg. The highest correlation coefficient of Huashengxian was 0.969 ( P = 0.02), the highest sensitivity of pressure measurement was 0.098 dB/mm Hg and the minimum RMSE was 2.00 mm Hg. The above in vitro experimental results indicate that by selecting ultrasound contrast agent microbubbles and optimizing acoustic pressure, the correlation between high-frequency subharmonic scattering of microbubbles and ambient pressure can be improved, the sensitivity of pressure measurement can be upgraded, and the measurement error can be reduced to meet the clinical demand for local brain tissue pressure measurement, which provided an important experimental basis for subsequent research in vivo.
Contrast Media
;
Microbubbles
;
Ultrasonography/methods*
9.Differentiation Between Amyotrophic Lateral Sclerosis and Mimics Using Quantitative Analysis of Fsciculation with Muscle Ultrasound.
Jing FAN ; Yi LI ; Jing-Wen NIU ; Nan HU ; Yu-Zhou GUAN ; Li-Ying CUI ; Ming-Sheng LIU
Chinese Medical Sciences Journal 2023;38(4):265-272
Objective To determine the diagnostic accuracy of the intensity of fasciculation evaluated by muscle ultrasound in the differential diagnosis of amyotrophic lateral sclerosis (ALS). Methods We prospectively recruited patients who had ALS and neuropathy-radiculopathy attending Peking Union Medical College Hospital from 2017 to 2020. Healthy adults from a community were recruited as healthy controls. Muscle strength was assessed using the Medical Research Council (MRC) scale. At the first visit to the hospital, patients were assessed for maximal grade of fasciculations, total fasciculation score, and fasciculation grade in 16 muscle groups of bilateral upper and lower limbs using ultrasonography. The sensitivity and specificity of maximal grade of fasciculations, total fasciculation score, and fasciculation grade for the diagnosis of ALS were assessed by receiver operating characteristic analyses. Results The percentage of limb muscles with a maximal fasciculation grade higher than grade 2 in ALS patients and neuropathy-radiculopathy patients was 84.9% and 9.8%, respectively (χ2 = 172.436, P < 0.01). Of the 16 limb muscles detected, the total fasciculation score [median (interquartile range)] was 29 (15, 41) in ALS patients and 3 (0, 8) in neuropathy-radiculopathy patients (Z = 9.642, P < 0.001). Remarkable fasciculations were seen in ALS patients whose muscles with a MRC score ranging from 2 to 4, followed by patients with MRC score 5, and then in those with MRC score 0 and 1. The sensitivity and specificity of total fasciculation score for diagnosis of ALS were 80.6% and 93.4%, respectively (cut-off value 14). In patients with ALS, for muscles with MRC score 4 and 5, the percentage of muscles with fasciculation grades ≥ 3 was 42.3% and 24.1% respectively, while in neuropathy-radiculopathy patients, the percentage for muscles with MRC score 4 and 5 was only 1.7% and 0, respectively. Conclusion A combined analysis of fasciculation intensity and MRC score of the limb muscles may be helpful for differential diagnosis of ALS.
Adult
;
Humans
;
Amyotrophic Lateral Sclerosis/diagnostic imaging*
;
Fasciculation/diagnostic imaging*
;
Radiculopathy
;
Muscle, Skeletal/diagnostic imaging*
;
Ultrasonography/methods*
10.Short-term effectiveness of ultrasound-guided Kirschner wire provocation technique in treatment of Salter-Harris types Ⅰ and Ⅱ periosteal entrapment of distal tibial epiphyseal fractures in children and adolescents.
Hailong MA ; Zhilin ZHOU ; Sicheng ZHANG ; Fang LIU ; Zhongtuo HUA ; Xiwei SUN ; Guoqiang JIA ; Jun SUN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1477-1481
OBJECTIVE:
To investigate the short-term effectiveness of ultrasound-guided closed reduction by Kirschner wire provocation technique in the treatment of Salter-Harris types Ⅰ and Ⅱ periosteal entrapment of distal tibial epiphyseal fractures in children and adolescents.
METHODS:
Between May 2019 and May 2022, 41 patients with Salter Harris types Ⅰ and Ⅱ distal tibial epiphyseal fractures were admitted, all of whom had periosteal entrapment on preoperative MRI, and 38 cases (92.7%) were confirmed to have periosteal entrapment by intraoperative ultrasound. There were 24 males and 14 females, the age ranged from 6.8 to 15.7 years, with an average of 10.7 years; and there were 20 cases of Salter Harris type Ⅰ and 18 cases of type Ⅱ. The time from injury to operation was 22-76 hours, with an average of 28.4 hours. The preoperative imaging examination showed excellent alignment in 4 cases, good in 20 cases, and poor in 14 cases. The ultrasound guided Kirschner wire provocation technique for closed reduction and percutaneous Kirschner wire internal fixation were performed. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Anteroposterior and lateral X-ray films of the affected ankle joint were taken before operation, at 3 months after operation, and at last follow-up to observe the healing of the fracture, and anteroposterior X-ray films of the whole length of both lower limbs were taken to evaluate the alignment of the force lines of the affected limbs. The range of motion (ROM), visual analogue scale (VAS) score, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score were used to evaluate ankle function. The mechanical lateral distal tibia angle (mLDTA) and the anatomic anterior distal tibia angle (aADTA) were measured.
RESULTS:
The operation time ranged from 17 to 52 minutes, with an average of 22.6 minutes, and the intraoperative fluoroscopy frequency ranged from 3 to 11 times, with an average of 4.2 times. X-ray examination during operation and at 2 days after operation showed that anatomical reduction was achieved. All patients were followed up 10-24 months, with an average of 16.4 months. All fractures healed in 6.1-7.2 weeks, with an average of 6.3 weeks; no fracture displacement occurred, and the patients recovered to their pre-injury level of motion at 6 months after operation. Needle tail irritation occurred in 2 cases at 4 weeks after operation, and they recovered after symptomatic treatment. During the follow-up, there was no serious complication such as incision deep infection, bone nonunion, delayed union, and malunion. At last follow-up, the patients' alignment were all excellent, and the difference was significant when compared with preoperative one ( Z=-7.471, P<0.001). The VAS score, AOFAS ankle-hindfoot score, dorsiflexion-plantar flexion ROM, varus-valgus ROM, mLDTA, and aADTA significantly improved at 3 months after operation and last follow-up when compared with preoperative ones ( P<0.05).
CONCLUSION
Ultrasound-guided closed reduction by Kirschner wire provocation technique for treating Salter-Harris types Ⅰ and Ⅱ periosteal entrapment of distal tibial epiphyseal fractures in children and adolescents is minimally invasive and safe.
Male
;
Female
;
Child
;
Humans
;
Adolescent
;
Tibia
;
Bone Wires
;
Treatment Outcome
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
;
Ultrasonography, Interventional
;
Retrospective Studies
;
Tibial Fractures/surgery*

Result Analysis
Print
Save
E-mail