1.Assessment of fetal superior mesenteric artery and vein by three-dimensional power Doppler sonography.
Xianpeng TANG ; Ruoling TAO ; Xinghao ZHANG ; Qiuzi JIN ; Wei HE
Journal of Zhejiang University. Medical sciences 2019;48(4):453-458
OBJECTIVE:
To analyze the application of three-dimensional power Doppler sonography (3-DPDS) in evaluation of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in second-trimester fetus.
METHODS:
Three-dimensional volume probe was used to collect the 3-DPDS blood flow images in 50 normal fetuses of 22-24 weeks and 50 fetuses of 30-32 weeks, respectively. The characteristics of three-dimensional ultrasound were analyzed. The clinical and imaging data of 4 fetuses of 26-32 weeks with midgut volvulus were analyzed retrospectively.
RESULTS:
The display rates of SMA and SMV were 93%in normal group by 3-DPDS and those in volvulus group were 4/4 and 3/4, respectively. The SMV trunk was parallel to and on the right side of the SMA in the normal group, while 3 cases in volvulus group showed the characteristic relationship of SMV swirling around SMA.
CONCLUSIONS
3-DPDS can be used to observe the spatial relationship of SMA and SMV visually in fetus during the second trimester and is of value to diagnose and predict the outcome of midgut volvulus.
Digestive System Abnormalities
;
diagnostic imaging
;
Female
;
Fetus
;
Humans
;
Intestinal Volvulus
;
diagnostic imaging
;
Mesenteric Artery, Superior
;
diagnostic imaging
;
Pregnancy
;
Pregnancy Trimester, Second
;
Retrospective Studies
;
Ultrasonography, Doppler
;
standards
2.Establishment of Reference Ranges for Prostate Volume and Annual Prostate Volume Change Rate in Korean Adult Men: Analyses of a Nationwide Screening Population.
Jinsung PARK ; Dong Gi LEE ; Beomseok SUH ; Sung Yong CHO ; In Ho CHANG ; Sung Hyun PAICK ; Hyung Lae LEE
Journal of Korean Medical Science 2015;30(8):1136-1142
We aimed to determine normal reference ranges for prostate volume (PV) and annual PV change rate in a Korean nationwide screening population. Data from men who underwent a routine health check-up were collected from 13 university hospitals. The cohort comprised men aged > or =40 yr who had undergone 2 or more serial transrectal ultrasonographies. Men with initial PV>100 mL; serum PSA level>10 ng/mL; PV reduction>20% compared with initial PV, or who had history of prostate cancer or prostate surgery, were excluded. Linear regression and mixed effects regression analyses were used to predict mean PV and longitudinal change in PV over time. A total of 2,967 men formed the study cohort. Age, body mass index (BMI), and serum prostate-specific antigen (PSA) level were found to be significant predictors of PV. A predicted PV table, with a 95% confidence interval (CIs), was developed after adjusting for these 3 variables. Annual PV change rate was 0.51 mL/year (95% CI, 0.47-0.55). Annual PV change rate according to age was 0.68 mL/year, 0.84 mL/year, 1.09 mL/year, and 0.50 mL/year for subjects in their 40s, 50s, 60s, and > or =70 yr, respectively. Predicted annual PV change rate differed depending on age, BMI, serum PSA level and baseline PV. From a nationwide screening database, we established age-, PSA-, and BMI-specific reference ranges for PV and annual PV change rate in Korean men. Our newly established reference ranges for PV and annual PV change rate will be valuable in interpreting PV data in Korean men.
Adult
;
Aged
;
Aged, 80 and over
;
Aging/*pathology
;
Humans
;
Male
;
Mass Screening/*standards
;
Middle Aged
;
Organ Size
;
Prostate/*anatomy & histology/ultrasonography
;
Reference Values
;
Reproducibility of Results
;
Republic of Korea
;
Sensitivity and Specificity
;
Ultrasonography/*standards
;
Urology/*standards
3.Reference interval for thyrotropin in a ultrasonography screened Korean population.
Mijin KIM ; Tae Yong KIM ; Soo Han KIM ; Yunkyoung LEE ; Su Yeon PARK ; Hyung Don KIM ; Hyemi KWON ; Yun Mi CHOI ; Eun Kyung JANG ; Min Ji JEON ; Won Gu KIM ; Young Kee SHONG ; Won Bae KIM
The Korean Journal of Internal Medicine 2015;30(3):335-344
BACKGROUND/AIMS: The diagnostic accuracy of thyroid dysfunctions is primarily affected by the validity of the reference interval for serum thyroid-stimulating hormone (TSH). Thus, the present study aimed to establish a reference interval for TSH using a normal Korean population. METHODS: This study included 19,465 subjects who were recruited after undergoing routine health check-ups. Subjects with overt thyroid disease, a prior history of thyroid disease, or a family history of thyroid cancer were excluded from the present analyses. The reference range for serum TSH was evaluated in a normal Korean reference population which was defined according to criteria based on the guidelines of the National Academy of Clinical Biochemistry, ultrasound (US) findings, and smoking status. Sex and age were also taken into consideration when evaluating the distribution of serum TSH levels in different groups. RESULTS: In the presence of positive anti-thyroid peroxidase antibodies or abnormal US findings, the central 95 percentile interval of the serum TSH levels was widened. Additionally, the distribution of serum TSH levels shifted toward lower values in the current smokers group. The reference interval for TSH obtained using a normal Korean reference population was 0.73 to 7.06 mIU/L. The serum TSH levels were higher in females than in males in all groups, and there were no age-dependent shifts. CONCLUSIONS: The present findings demonstrate that the serum TSH reference interval in a normal Korean reference population was higher than that in other countries. This result suggests that the upper and lower limits of the TSH reference interval, which was previously defined by studies from Western countries, should be raised for Korean populations.
Adult
;
Age Factors
;
Aged
;
Biomarkers/blood
;
Case-Control Studies
;
Cross-Sectional Studies
;
Female
;
Humans
;
Male
;
Middle Aged
;
Predictive Value of Tests
;
Reference Values
;
Republic of Korea
;
Sex Factors
;
Smoking/blood
;
Thyroid Diseases/blood/*diagnosis/ultrasonography
;
Thyroid Function Tests/*standards
;
Thyroid Gland/*metabolism/*ultrasonography
;
Thyrotropin/*blood
;
Time Factors
;
Young Adult
4.Retrieval Rate and Accuracy of Ultrasound-Guided 14-G Semi-Automated Core Needle Biopsy of Breast Microcalcifications.
Jisook YI ; Eun Hye LEE ; Jeong Ja KWAK ; Jang Gyu CHA ; Sun Hye JUNG
Korean Journal of Radiology 2014;15(1):12-19
OBJECTIVE: To evaluate the retrieval rate and accuracy of ultrasound (US)-guided 14-G semi-automated core needle biopsy (CNB) for microcalcifications in the breast. MATERIALS AND METHODS: US-guided 14-G semi-automated CNB procedures and specimen radiography were performed for 33 cases of suspicious microcalcifications apparent on sonography. The accuracy of 14-G semi-automated CNB and radiology-pathology concordance were analyzed and the microcalcification characteristics between groups with successful and failed retrieval were compared. RESULTS: Thirty lesions were successfully retrieved and the microcalcification retrieval rate was 90.9% (30/33). Thirty lesions were successfully retrieved. Twenty five were finally diagnosed as malignant (10 invasive ductal carcinoma, 15 ductal carcinoma in situ [DCIS]) and five as benign. After surgery and mammographic follow-up, the 25 malignant lesions comprised 12 invasive ductal carcinoma and 13 DCIS. Three lesions in the failed retrieval group (one DCIS and two benign) were finally diagnosed as two DCIS and one benign after surgery. The accuracy of 14-G semi-automated CNB was 90.9% (30/33) because of two DCIS underestimates and one false-negative diagnosis. The discordance rate was significantly higher in the failed retrieval group than in the successful retrieval group (66.7% vs. 6.7%; p < 0.05). Punctate calcifications were significantly more common in the failed retrieval group than in the successful retrieval group (66.7% vs. 3.7%; p < 0.05). CONCLUSION: US-guided 14-G semi-automated CNB could be a useful procedure for suspicious microcalcifications in the breast those are apparent on sonography.
Adult
;
Aged
;
Biopsy, Large-Core Needle/*methods/standards
;
Breast/*pathology
;
Breast Diseases/pathology/radiography
;
Breast Neoplasms/*pathology/surgery/ultrasonography
;
Calcinosis/*pathology/ultrasonography
;
Carcinoma, Ductal, Breast/*pathology/ultrasonography
;
Carcinoma, Intraductal, Noninfiltrating/*pathology/radiography
;
Female
;
Humans
;
Middle Aged
;
*Ultrasonography, Interventional/standards
;
Young Adult
5.Accuracy of sonographic diagnosis of pneumoperitoneum using the enhanced peritoneal stripe sign in beagle dogs.
Song Yeon KIM ; Ki Tae PARK ; Seong Chan YEON ; Hee Chun LEE
Journal of Veterinary Science 2014;15(2):195-198
The objective of this study was to evaluate the feasibility and accuracy of estimating the smallest amount of abdominal free gas detectible in a large population of beagles by ultrasonography. Healthy dogs were randomly divided into three groups: group A that received 0.1 mL of air injected into the peritoneal cavity, group B that received 0.2 mL of air injected into the peritoneal cavity, and group C that received 0.5 mL of intraperitoneal air. Randomly, some dogs in each group did not receive air injection for the negative control. All ultrasonographic procedures were performed by individuals blinded to group assignments and the presence of intraperitoneal air. The minimum volume of consistently detectable air with good accuracy and reliability was 0.2 mL. Results of the study demonstrated that the enhanced peritoneal stripe sign (EPSS) can verify cases of pneumoperitoneum if more than 0.2 mL of intra-abdominal free gas is present The EPSS is a reliable and specific ultrasonographic characteristic for diagnosing pneumoperitoneum in dogs.
Animals
;
Dog Diseases/*ultrasonography
;
Dogs
;
Female
;
Male
;
Pneumoperitoneum/ultrasonography/*veterinary
;
Reproducibility of Results
;
Species Specificity
;
Ultrasonography/standards/veterinary
6.Echocardiographic assessment of coronary artery flow in normal canines and model dogs with myocardial infarction.
Nohwon PARK ; Jaehwan KIM ; Miyoung LEE ; Soyun LEE ; Sunhye SONG ; Seungjun LEE ; Soyoung KIM ; Yangwoo PARK ; Kidong EOM
Journal of Veterinary Science 2014;15(1):149-155
This study was conducted to evaluate the usefulness of coronary arterial profiles from normal dogs (11 animals) and canines (six dogs) with experimental myocardial infarction (MI) induced by ligation of the left coronary artery (LCA). Blood velocity of the LCA and right coronary artery (RCA) were evaluated following transthoracic pulsed-wave Doppler echocardiography. The LCA was observed as an infundibular shape, located adjacent to the sinus of Valsalva. The RCA appeared as a tubular structure located 12 o'clock relative to the aorta. In normal dogs, the LCA and RCA mean peak diastolic velocities were 20.84 +/- 3.24 and 19.47 +/- 2.67 cm/sec, respectively. The LCA and RCA mean diastolic deceleration times were 0.91 +/- 0.14 sec and 1.13 +/- 0.20 sec, respectively. In dogs with MI, the LCA had significantly (p < 0.01) lower peak velocities (14.82 +/- 1.61 cm/sec) than the RCA (31.61 +/- 2.34 cm/sec). The RCA had a significantly (p < 0.01) rapid diastolic deceleration time (0.71 +/- 0.06 sec) than that found in the LCA (1.02 +/- 0.22 sec) of MI dogs. In conclusion, these profiles may serve as a differential factor for evaluating cardiomyopathy in dogs.
Animals
;
Blood Flow Velocity/*veterinary
;
Coronary Vessels/surgery/*ultrasonography
;
Dog Diseases/*diagnosis
;
Dogs/*physiology
;
Echocardiography, Doppler, Pulsed/standards/*veterinary
;
Female
;
Male
;
Myocardial Infarction/diagnosis/*veterinary
7.Clinical trial requests of indigenous diagnostic imaging ultrasound devices in first-time registration application.
Zhaojun GUO ; Guofang CAO ; Kan TAO
Chinese Journal of Medical Instrumentation 2012;36(6):438-440
This article introduces the clinical requests of indigenous diagnostic imaging ultrasound devices in first-time registration application and the clinical trial requests in Technical Review Guidance of Ultrasound Imaging Diagnostic Devices (category III) Registration and puts forward some questions of the guidance's implementation. It is hoped to help concerned people.
China
;
Clinical Trials as Topic
;
standards
;
Device Approval
;
legislation & jurisprudence
;
standards
;
Guidelines as Topic
;
Ultrasonography
;
instrumentation
8.Diagnostic Performance of Thyroglobulin Value in Indeterminate Range in Fine Needle Aspiration Washout Fluid from Lymph Nodes of Thyroid Cancer.
Yu Mee SOHN ; Min Jung KIM ; Eun Kyung KIM ; Jin Young KWAK
Yonsei Medical Journal 2012;53(1):126-131
PURPOSE: The purpose was to compare the frequency of metastatic and nonmetastatic lymph nodes diagnosed by fine needle aspiration biopsy cytology (FNAC) and thyroglobulin concentration from fine needle aspiration biopsy washout fluid (FNAB-Tg) in an indeterminate range (0.2-100 ng/mL), and to evaluate the most appropriate threshold value of FNAB-Tg in an indeterminate range. MATERIALS AND METHODS: We performed ultrasound-guided FNAB and FNAB-Tg in suspicious metastatic cervical lymph nodes of papillary thyroid carcinoma and performed surgery. Ninety-five lymph nodes with indeterminate values of FNAB-Tg ranging from 0.2-100 ng/mL in ninety-two patients were included in this study. The diagnostic performances in multiple Tg levels (0.7, 1.0, 5.0, 10.0, 20.0, 50.0) were evaluated to compare with FNAB cytology using sensitivity, specificity, and accuracy with area under the curve (AUC) analysis. RESULTS: Forty-two were metastatic lymph nodes and fifty three were nonmetastatic lymph nodes. FNAB-Tg ranged from 0.22 to 90.9 ng/mL in metastatic lymph nodes (mean; 34.3+/-33.3 ng/mL) and 0.20 to 56.7 ng/mL in nonmetastatic lymph nodes (mean; 4.9+/-11.1 ng/mL) (p<0.001). The most excellent diagnostic performance was displayed in 5 ng/mL of FNAB-Tg with AUC of 0.76, sensitivity, specificity, accuracy, 69.0, 83.0, and 76.8, respectively. However, there was no significant difference from 10 ng/mL FNAB. CONCLUSION: We ascertained that 5 ng/mL yielded the most excellent diagnostic performance among FNAB-Tg levels in the present setting with a large series with the indeterminate range (0.2-100 ng/mL) of FNAB-Tg values. These results need additional confirmation under different laboratory conditions.
Biopsy, Fine-Needle/*methods/standards/statistics & numerical data
;
Body Fluids/metabolism
;
Carcinoma, Papillary/*metabolism/*secondary/ultrasonography
;
Humans
;
Lymph Nodes/metabolism/pathology/ultrasonography
;
Lymphatic Metastasis
;
Retrospective Studies
;
Sensitivity and Specificity
;
Thyroglobulin/*metabolism
;
Thyroid Neoplasms/*metabolism/*secondary/ultrasonography
;
Ultrasonography, Interventional
9.Experimental study of non-traumatic ultrasonic testing for pork quality.
Xiaoliang HU ; Baolin LIU ; Guoyan ZHOU
Journal of Biomedical Engineering 2011;28(4):819-822
We carried out experiments with B-scan technology, computer image processing technology and statistical analysis, to extract feature parameters from histogram of different organizations in order to establish prediction methods of the meat quality of pigs. We then Explored and solved the assessment problems of intramuscular fat (IMF) content, to provide reference standards of using ultrasound for the classification of pork.
Adipose Tissue
;
diagnostic imaging
;
Animals
;
Meat
;
analysis
;
standards
;
Muscle, Skeletal
;
chemistry
;
diagnostic imaging
;
Quality Control
;
Swine
;
Ultrasonography
10.The research progress of breast ultrasound CAD with breast imaging and reporting data system.
Jun SHI ; Ruiling WANG ; Shichong ZHOU ; Cai CHANG
Journal of Biomedical Engineering 2010;27(5):1169-1172
Ultrasound imaging is a valuable tool in the detection of breast lesions, and the breast imaging and reporting data system (BI-RADS) guides the ultrasound diagnosis of breast lesion to improve the diagnosis accuracy. The research of breast ultrasound computer-aided diagnosis (CAD) with BI-RADS-US is a hot topic now. In this paper, we reviewed the research progress of breast ultrasound CAD with BI-RADS-US, summarized the present problems, and discussed the future development.
Algorithms
;
Artifacts
;
Breast Neoplasms
;
diagnostic imaging
;
Diagnosis, Computer-Assisted
;
methods
;
Female
;
Humans
;
Information Systems
;
standards
;
Sensitivity and Specificity
;
Ultrasonography, Mammary
;
methods

Result Analysis