1.A prospective study of super-thin anterolateral thigh flap harvesting assisted by high-frequency color Doppler ultrasound in detecting perforators in deep adipose layers.
Qianyuan LIU ; Jiandong ZHOU ; Wencheng WANG ; Xueming CHEN ; Yajun XU ; Hai HUANG ; Jingyi MI
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):62-68
OBJECTIVE:
To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF).
METHODS:
Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m 2, with an average of 23.62 kg/m 2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured.
RESULTS:
A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory.
CONCLUSION
Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.
Male
;
Female
;
Humans
;
Thigh/surgery*
;
Plastic Surgery Procedures
;
Prospective Studies
;
Skin Transplantation
;
Free Tissue Flaps
;
Burns
;
Soft Tissue Injuries/surgery*
;
Ultrasonography, Doppler, Color
;
Crush Injuries/surgery*
;
Perforator Flap
;
Treatment Outcome
2.Immediate postoperative color Doppler ultrasonography on the diagnosis of hemorrhagic complications of liver biopsy and its directed compression hemostasis.
Guo Quan ZHANG ; Ling Yun ZHANG ; Guo Qing HAN ; Yu Hua ZHU ; Ai Min ZHENG
Chinese Journal of Hepatology 2022;30(3):285-289
Objective: To study the diagnostic value of immediate color Doppler ultrasonography on traumatic hepatic hemorrhage after tissue sampling with ultrasound-guided liver biopsy and the clinical effect of its-directed local compression hemostasis at puncture-site. Methods: 132 hospitalized patients with various liver diseases underwent ultrasound-guided hepatic puncture-biopsies, including 61 cases with diffuse parenchymal and 71 cases with focal liver lesions. Immediate postoperative color Doppler ultrasonography was performed following liver biopsy. Abnormal blood flow signal was observed at hepatic puncture biopsy site, and if there were hemorrhagic signals, ultrasound-directed local compression hemostasis was performed until the bleeding signal disappeared. F-test and Chi-square test were used for statistical analysis. Results: Immediate color Doppler ultrasonography showed traumatic hemorrhage in 36.1% (22/61) and 40.8% (29/71) cases of diffuse liver disease and focal liver disease group, respectively. All hemorrhagic signals were eventually disappeared after ultrasound-directed local compression hemostasis. The median hemostasis time was 2 min in both groups, and there was no statistically significant difference in bleeding rate and hemostasis time between the two groups (P>0.05). There were no serious complications and deaths. Conclusion: Traumatic hepatic hemorrhage along the needle puncture tract is a common accompanying condition during liver biopsy. Immediate postoperative color Doppler ultrasonography can trace bleeding signals in timely manner and direct effective compression hemostasis, so it should be used routinely to help avoid occurrence of severe hemorrhagic complications.
Biopsy
;
Hemorrhage/etiology*
;
Hemostasis/physiology*
;
Humans
;
Liver/pathology*
;
Liver Diseases/pathology*
;
Ultrasonography
;
Ultrasonography, Doppler, Color/adverse effects*
3.A rare case of first-trimester placenta increta in an unscarred uterus: Diagnostic and management strategies
Stephanie F. Locsin ; Carmencita B. Tongco
Philippine Journal of Obstetrics and Gynecology 2021;45(2):82-86
Placenta accreta syndrome (PAS) is rare in first-trimester abortions with an unscarred uterus. It is this rarity that makes diagnosis and management difficult and challenging. This is a case report of a multigravid with an early incomplete abortion complicated by PAS (placenta increta) manifesting as an ill-defined hypervascular uterine cavity mass on transvaginal ultrasound, with decreasing trends of serum beta-human chorionic gonadotropin. PAS was successfully diagnosed preoperatively, and an uneventful hysterectomy was performed. A curettage that could potentially lead to catastrophic hemorrhage was prevented. This case highlights the diagnostic dilemma in early trimester PAS, the importance of early accurate diagnosis, and a good correlation with ancillary diagnostics to provide prompt and appropriate management.
Pregnancy
;
Placenta Accreta
;
Ultrasonography, Doppler, Color
4.Ultrasonographic Demonstration of the Tissue Microvasculature in Children: Microvascular Ultrasonography Versus Conventional Color Doppler Ultrasonography
Joonghyun YOO ; Bo Kyung JE ; Ji Yung CHOO
Korean Journal of Radiology 2020;21(2):146-158
Doppler ultrasound technique. It uses an advanced clutter filter that can remove clutter artifacts and preserve the low-velocity microvascular flow signal. The potential advantages of microvascular ultrasonography are its superiority in detection and visualization of the small blood vessels in tissues, providing radiologists with more information on the vascular structures. Therefore, it has shown particular value in the clinical fields. The aim of this study was to provide microvascular ultrasonographic images for the tissue microvasculature, including the brain, thyroid gland, kidney, urinary bladder, small bowel, ovary, testis, lymph node, and hemangiomas in children, focusing on the comparison with conventional color Doppler ultrasonographic images.]]>
Artifacts
;
Blood Vessels
;
Brain
;
Child
;
Female
;
Hemangioma
;
Humans
;
Kidney
;
Lymph Nodes
;
Microvessels
;
Ovary
;
Testis
;
Thyroid Gland
;
Ultrasonography
;
Ultrasonography, Doppler, Color
;
Urinary Bladder
5.Subinguinal microsurgical varicocelectomy is safe and effective in a solitary testicle.
Piotr DOBRONSKI ; Karolina DOBRONSKA ; Lukasz KUPIS ; Piotr RADZISZEWSKI
Asian Journal of Andrology 2020;22(1):120-121
Adult
;
Asthenozoospermia/complications*
;
Azoospermia/surgery*
;
Humans
;
Male
;
Microsurgery/methods*
;
Oligospermia/complications*
;
Orchiectomy
;
Seminoma/surgery*
;
Testicular Neoplasms/surgery*
;
Ultrasonography, Doppler, Color/methods*
;
Urologic Surgical Procedures, Male/methods*
;
Varicocele/surgery*
6.Value of Doppler evaluation of physically abnormal fistula: hemodynamic guidelines and access outcomes.
Seong CHO ; Yu Ji LEE ; Sung Rok KIM
The Korean Journal of Internal Medicine 2019;34(1):137-145
BACKGROUND/AIMS: The strategy of access care at out center involves the use of ultrasound (USG) in case of physical examination (PE) abnormality. USG determines the need of angiography. This study investigated the possible association between the need for percutaneous transluminal angioplasty (PTA) and hemodynamic parameters of USG. The study also assessed the effects of this monitoring strategy on outcomes in comparison with a historical control. METHODS: A retrospective study of the medical records of 127 patients (65 PTA, 62 non-PTA) was conducted. Data were analyzed using logistic regression analysis and receiver operating characteristic curve. Fistula outcomes and intervention rates were calculated and compared with 100 historic controls. RESULTS: Logistic regression analysis showed that brachial artery flow volume (FV) < 612.9 mL/min or brachial artery resistance index (RI) > 0.63 was independently associated with the need for PTA. This monitoring strategy showed an a reduction in thromboses (0.02 ± 0.11 events/arteriovenous fistula [AVF]-year vs. 0.07 ± 0.23 events/AVF-year, p = 0.046), reduction in central venous catheter placement (0.01 ± 0.05 events/AVF-year vs. 0.06 ± 0.22 events/AVF-year, p = 0.010), reduction in access loss (0.02 ± 0.13 events/AVF-year vs. 0.19 ± 0.34 events/AVF-year, p = 0.015), and increase in access selective repair (0.49 ± 0.66 events/AVF-year vs. 0.21 ± 0.69 events/AVF-year, p = 0.003), compared to historic control. CONCLUSIONS: There was significant stenosis if brachial artery FV was < 612.9 mL/min or RI was > 0.63 for PE abnormality. These parameters should be used as markers for assessing PTA risk in hemodialysis patients. Addition of USG to determine the need of angiography after detection of PE abnormality leads to decreases in access thrombosis, catheter placement, and access loss despite increasing access intervention rates compared to clinical monitoring.
Angiography
;
Angioplasty
;
Brachial Artery
;
Catheters
;
Central Venous Catheters
;
Constriction, Pathologic
;
Fistula*
;
Hemodynamics*
;
Humans
;
Logistic Models
;
Medical Records
;
Physical Examination
;
Renal Dialysis
;
Retrospective Studies
;
ROC Curve
;
Thrombosis
;
Ultrasonography
;
Ultrasonography, Doppler, Color
7.Abdominal ultrasonography with color Doppler analysis in the assessment of ileal Crohn's disease: comparison with magnetic resonance enterography
Antonio Carlos DA SILVA MORAES ; Glycia DE FREITAS MORAES ; Antonio Luis Eiras DE ARAÚJO ; Ronir Raggio LUIZ ; Celeste ELIA ; Antonio Jose CARNEIRO ; Heitor Siffert Pereira DE SOUZA
Intestinal Research 2019;17(2):227-236
BACKGROUND/AIMS: Consistently defining disease activity remains a critical challenge in the follow-up of patients with Crohn's disease (CD). We investigated the potential applicability of abdominal ultrasonography with color Doppler (USCD) analysis for the detection of morphological alterations and inflammatory activity in CD. METHODS: Forty-three patients with CD ileitis/ileocolitis were evaluated using USCD analysis with measurements obtained on the terminal ileum and right colon. Sonographic parameters included wall thickening, stricture, hyperemia, presence of intra-abdominal mass, and fistulas. Patients were evaluated for the clinical activity (Harvey-Bradshaw Index [HBI]), fecal calprotectin (FC) and C-reactive protein (CRP). The USCD performance was assessed using magnetic resonance enterography (MRE) as a criterion standard. RESULTS: Most measurements obtained with USCD matched the data generated with MRE; however, the agreement improved in clinically active patients where sensitivity, positive predictive value, and accuracy were >80%, considering wall thickening and hyperemia. Complications such as intestinal wall thickening, stricture formation, and hyperemia, were detected in the USCD analysis with moderate agreement with MRE. The best agreement with the USCD analysis was obtained in regard to FC, where the sensitivity, positive predictive value, and accuracy were >70%. The overall performance of USCD was superior to that of HBI, FC and CRP levels, particularly when considering thickening, stricture, and hyperemia parameters. CONCLUSIONS: USCD represents a practical noninvasive and low-cost tool for evaluating patients with ileal or ileocolonic disease, particularly in clinically active CD. Therefore, USCD might become a useful asset in the follow-up of patients with CD.
C-Reactive Protein
;
Colon
;
Constriction, Pathologic
;
Crohn Disease
;
Fistula
;
Follow-Up Studies
;
Humans
;
Hyperemia
;
Ileitis
;
Ileum
;
Leukocyte L1 Antigen Complex
;
Magnetic Resonance Imaging
;
Ultrasonography
;
Ultrasonography, Doppler, Color
8.Dynamic infusion cavernosometry and cavernosography for classifying venous erectile dysfunction and its significance for individual treatment.
Qing-Qiang GAO ; Jian-Huai CHEN ; Yun CHEN ; Tao SONG ; Yu-Tian DAI
Chinese Medical Journal 2019;132(4):405-410
BACKGROUND:
The precise pathophysiology of venous erectile dysfunction (VED) was still unclear. Dynamic infusion cavernosometry and cavernosography (DICC) was the gold standard approach for the diagnoses of VED. However, a standard operative procedure of DICC was needed and it was unclear whether DICC could show promise in accurate assessment and treatment of VED. The aim of this study was to establish an optimized operation process of DICC and evaluate the efficacy of DICC in the diagnoses and therapy of VED.
METHODS:
One hundred and forty-seven VED patients identified by the color doppler duplex ultrasonography (CDDU) were included. Then the method of DICC was adopted to assess the severity of VED and all patients were divided into 4 groups, including (1) non-VED; (2) mild VED; (3) moderate VED and (4) severe VED. All patients received the treatment of psychotherapy. Drug therapy, the intervention embolism of corpus cavernosum and the implantation of penile prosthesis were applied if psychotherapy was ineffective for patients. The international index of erectile function (IIEF-5) scores of patients were collected and compared before and after treatment.
RESULTS:
IIEF-5 score of non-VED group after psychotherapy (19.35 ± 3.59) and drug therapy (23.31 ± 0.75) was higher than that before psychotherapy (15.30 ± 2.72, t = -4.31, P < 0.01) and drug therapy (16.62 ± 1.50, t = -19.13, P < 0.01). IIEF-5 scores of mild VED (18.25 ± 2.60) and moderate VED group (14.83 ± 4.17) after treatment was improved significantly by intervention embolism of corpus cavernosum when compared with those before treatment (mild: 15.50 ± 2.14, t = -2.31, P < 0.05; moderate: 11.83 ± 2.86, t = -1.45, P < 0.05). However, drug therapy and intervention embolism (IE) of corpus cavernosum showed poor effects on patients with moderate and severe VED patients (P > 0.05). IIEF-5 score of severe VED group was increased under the treatment of implantation of penile prosthesis (23.25 ± 0.71) compared with that before treatment (8.00 ± 0.39, t = -53.25, P < 0.05).
CONCLUSION
DICC was a valid diagnostic tool that could identify patients with VED. And DICC had great effect on the diagnosis and individual therapy for patients with VED in varying degrees. Moreover, the manipulation of DICC needed uniform standards.
Adult
;
Embolization, Therapeutic
;
Humans
;
Impotence, Vasculogenic
;
diagnosis
;
therapy
;
Male
;
Middle Aged
;
Penis
;
blood supply
;
diagnostic imaging
;
Ultrasonography, Doppler, Color
;
Veins
9.Correlation of grayscale combined with color doppler sonography from histopathology in predicting retained products of conception
Jeptah Komiya-Padilla ; Leilani Go-Suva
Philippine Journal of Obstetrics and Gynecology 2019;43(3):22-30
Background:
Retained products of conception can be troublesome complications following miscarriages. Ultrasound has a significant impact in their diagnosis and with the advent of color doppler sonography can improve the assessment.
Objective:
The goal of this study was to evaluate the use of grayscale combined with color Doppler ultrasound findings and correlate with histopathology in predicting retained products of conception in a maternity hospital.
Methods:
This was a cross sectional prospective study of 109 patients who underwent transvaginal grayscale ultrasound with color Doppler to evaluate the presence of retained products of conception. Resistance index(RI) is measured in Pulsed doppler to assess the impedance of blood flow. The standard criterion was the histopathologic reports obtained during completion curettage.
Results:
Histopathologic results validated the presence of immature placental tissues in 93 (85%) patients and decidua in 16 (15%). Endometrial mass was greater with positive histopath results (p<0.05). Endometrial mass had a sensitivity of 83.9% in detecting retained products of conception. Thickened endometrium was detected in 71.4 % of women with positive histopath results, but only in 28.6% with negative histopath results. Color flow was confirmed in 85% with positive histopathology results.
Conclusion
The combination of an endometrial mass with vascular pattern had the highest positive predictive value in determining retained products of conception.
Abortion, Spontaneous
;
Decidua
;
Ultrasonography, Doppler, Color
10.Color Doppler Ultrasonography Is a Useful Tool for Diagnosis of Peripheral Artery Disease in Type 2 Diabetes Mellitus Patients with Ankle-Brachial Index 0.91 to 1.40
Kyu Yeon HUR ; Ji Eun JUN ; Young Ju CHOI ; Yong ho LEE ; Dae Jung KIM ; Seok Won PARK ; Byung Wook HUH ; Eun Jig LEE ; Sun Ha JEE ; Kap Bum HUH ; Sung Hee CHOI
Diabetes & Metabolism Journal 2018;42(1):63-73
BACKGROUND: The clinical utility of ankle-brachial index (ABI) is not clear in subjects with less severe or calcified vessel. Therefore, we investigated the usefulness of color Doppler ultrasonography for diagnosing peripheral artery disease (PAD) in type 2 diabetes mellitus (T2DM) subjects. METHODS: We analyzed 324 T2DM patients who concurrently underwent ABI and carotid intima-media thickness (CIMT) measurements and color Doppler ultrasonography from 2003 to 2006. The degree of stenosis in patients with PAD was determined according to Jager's criteria, and PAD was defined as grade III (50% to 99% stenosis) or IV stenosis (100% stenosis) by color Doppler ultrasonography. Logistic regression analysis and receiver operating characteristic curve analysis were performed to evaluate the risk factors for PAD in patients with ABI 0.91 to 1.40. RESULTS: Among the 324 patients, 77 (23.8%) had ABI 0.91 to 1.40 but were diagnosed with PAD. Color Doppler ultrasonography demonstrated that suprapopliteal arterial stenosis, bilateral lesions, and multivessel involvement were less common in PAD patients with ABI 0.91 to 1.40 than in those with ABI ≤0.90. A multivariate logistic regression analysis demonstrated that older age, current smoking status, presence of leg symptoms, and high CIMT were significantly associated with the presence of PAD in patients with ABI 0.91 to 1.40 after adjusting for conventional risk factors. CIMT showed significant power in predicting the presence of PAD in patients with ABI 0.91 to 1.40. CONCLUSION: Color Doppler ultrasonography is a useful tool for the detection of PAD in T2DM patients with ABI 0.91 to 1.40 but a high CIMT.
Ankle Brachial Index
;
Carotid Intima-Media Thickness
;
Constriction, Pathologic
;
Diabetes Mellitus, Type 2
;
Diagnosis
;
Humans
;
Leg
;
Logistic Models
;
Peripheral Arterial Disease
;
Risk Factors
;
ROC Curve
;
Smoke
;
Smoking
;
Ultrasonography, Doppler, Color


Result Analysis
Print
Save
E-mail