1.Low-Cost Phantom Model for Simulation Training in Ultrasound-Guided Ethanol Ablation of a Cystic Thyroid Nodule.
Darryl Young S DUGUIL ; Raphael S ROJAS ; Maria Karen A CAPUZ
Philippine Journal of Otolaryngology Head and Neck Surgery 2025;40(1):37-41
Objective:To describe a low-cost, reproducible phantom model for training medical practitioners in ultrasound-guided ethanol ablation (EA) of a cystic thyroid nodule.
Methods:The model of cyst contents was created using a mixture of coffee powder, cornstarch and water to mimic colloidal contents. This was injected into the finger of a cut surgical glove secured with transparent tape to serve as an inflatable capsule and placed inside a chicken breast. This setup allows practitioners to perform key ultrasound-guided ethanol ablation techniques including spinal needle insertion, cyst aspiration, saline flushing, re-aspiration and ethanol injection.
Results:The phantom model was assembled for PhP 150.30 per unit and took approximately 5 minutes to construct. This model was demonstrated to be a cost-effective and simple method for enabling specialists to practice and enhance their skills in ultrasound-guided ethanol ablation of a cystic thyroid nodule.
Conclusion:The described phantom model provides an accessible and practical training tool for healthcare providers to gain proficiency in ultrasound-guided ethanol ablation of a cystic thyroid nodule in a safe and controlled setting prior to actual patient handling.
Medical Education ; Otorhinolaryngology ; Radiology ; Ultrasonography
2.A prospective study of super-thin anterolateral thigh flap harvesting assisted by high-frequency color Doppler ultrasound in detecting perforators in deep adipose layers.
Qianyuan LIU ; Jiandong ZHOU ; Wencheng WANG ; Xueming CHEN ; Yajun XU ; Hai HUANG ; Jingyi MI
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):62-68
OBJECTIVE:
To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF).
METHODS:
Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m 2, with an average of 23.62 kg/m 2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured.
RESULTS:
A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory.
CONCLUSION
Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.
Male
;
Female
;
Humans
;
Thigh/surgery*
;
Plastic Surgery Procedures
;
Prospective Studies
;
Skin Transplantation
;
Free Tissue Flaps
;
Burns
;
Soft Tissue Injuries/surgery*
;
Ultrasonography, Doppler, Color
;
Crush Injuries/surgery*
;
Perforator Flap
;
Treatment Outcome
3.Noninvasive Diagnostic Technique for Nonalcoholic Fatty Liver Disease Based on Features of Tongue Images.
Rong-Rui WANG ; Jia-Liang CHEN ; Shao-Jie DUAN ; Ying-Xi LU ; Ping CHEN ; Yuan-Chen ZHOU ; Shu-Kun YAO
Chinese journal of integrative medicine 2024;30(3):203-212
OBJECTIVE:
To investigate a new noninvasive diagnostic model for nonalcoholic fatty liver disease (NAFLD) based on features of tongue images.
METHODS:
Healthy controls and volunteers confirmed to have NAFLD by liver ultrasound were recruited from China-Japan Friendship Hospital between September 2018 and May 2019, then the anthropometric indexes and sampled tongue images were measured. The tongue images were labeled by features, based on a brief protocol, without knowing any other clinical data, after a series of corrections and data cleaning. The algorithm was trained on images using labels and several anthropometric indexes for inputs, utilizing machine learning technology. Finally, a logistic regression algorithm and a decision tree model were constructed as 2 diagnostic models for NAFLD.
RESULTS:
A total of 720 subjects were enrolled in this study, including 432 patients with NAFLD and 288 healthy volunteers. Of them, 482 were randomly allocated into the training set and 238 into the validation set. The diagnostic model based on logistic regression exhibited excellent performance: in validation set, it achieved an accuracy of 86.98%, sensitivity of 91.43%, and specificity of 80.61%; with an area under the curve (AUC) of 0.93 [95% confidence interval (CI) 0.68-0.98]. The decision tree model achieved an accuracy of 81.09%, sensitivity of 91.43%, and specificity of 66.33%; with an AUC of 0.89 (95% CI 0.66-0.92) in validation set.
CONCLUSIONS
The features of tongue images were associated with NAFLD. Both the 2 diagnostic models, which would be convenient, noninvasive, lightweight, rapid, and inexpensive technical references for early screening, can accurately distinguish NAFLD and are worth further study.
Humans
;
Non-alcoholic Fatty Liver Disease/diagnostic imaging*
;
Ultrasonography
;
Anthropometry
;
Algorithms
;
China
4.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
8.Comparison on Performance of Quantitative Ultrasound and Dual-Energy X-ray Absorptiometry in Evaluating Bone Health of Adults Aged 18-40 Years.
Yu-Xian KUANG ; Hong CHENG ; Yi-Ying ZHENG ; Wei-Ye CHEN ; Zhen-Xin MA ; Gao-Yong ZOU ; Ding ZENG ; Jie MI ; Li LIU
Acta Academiae Medicinae Sinicae 2023;45(5):737-742
Objective To compare the consistency of quantitative ultrasound(QUS)and dual-energy X-ray absorptiometry(DXA)in measuring bone mineral density(BMD)of adults aged 18-40 years in Guangzhou and evaluate the diagnostic value of QUS for identifying low bone mass.Methods DXA was employed to measure the BMD and QUS to measure the speed of sound(SOS)in 731 participants.The Bland-Altman analysis was performed to evaluate the consistency of Z scores between SOS and BMD.With the BMD Z ≤-2.00 as the diagnostic criterion for low bone mass,the receiver operating characteristics curve of QUS was established,and the area under the curve(AUC)and the sensitivity,specificity,and correct diagnostic index for the optimal cut-off of SOS Z score were calculated.Results The results of Bland-Altman analysis showed that the mean differences in the Z scores of SOS and BMD in males and females were 1.27(-0.94 to 3.47)and 0.93(-1.33 to 3.18),respectively.The AUC of SOS Z score in the diagnosis of low bone mass in males and females was 0.734(95%CI=0.380-0.788)and 0.679(95%CI=0.625-0.732),respectively.In males,the optimal cut-off of SOS Z score for low bone mass was -0.35,with the sensitivity,specificity,and correct diagnostic index of 64.1%,68.6%,and 0.327,respectively.In females,the optimal cut-off value of SOS Z scores for low bone mass was -1.14,with the sensitivity,specificity,and correct index of 73.9%,54.8%,and 0.285,respectively.Conclusion QUS and DXA show poor consistency in the diagnosis of BMD in the adults aged 18-40 years in Guangzhou,while QUS demonstrates an acceptable value in identifying low bone mass.
Male
;
Female
;
Adult
;
Humans
;
Absorptiometry, Photon/methods*
;
Bone Density
;
Ultrasonography
;
Bone and Bones
;
ROC Curve
;
Sensitivity and Specificity
9.Effect of Calcification on the Ultrasound-Guided Radiofrequency Ablation of Papillary Thyroid Carcinoma.
Yi-Ming LI ; Lin YAN ; Jing XIAO ; Ming-Bo ZHANG ; Yu-Kun LUO
Acta Academiae Medicinae Sinicae 2023;45(5):803-808
Objective To investigate the effect of calcification on the ultrasound-guided radiofrequency ablation(RFA)of papillary thyroid carcinoma(PTC).Methods We retrospectively analyzed the preoperative and follow-up data of 164 patients(182 nodules)with PTC treated by percutaneous ultrasound-guided RFA in the First Medical Center of Chinese PLA General Hospital from January 1,2018 to December 31,2021.The tumor status 12 months after RFA was taken as the endpoint event.The univariate Logistic regression analysis was employed to predict the influencing factors of incomplete ablation.The factors were then included in the multivariate Logistic regression analysis for prediction of the independent risk factors of incomplete ablation.Results The maximum nodule diameter(OR=1.16,95%CI=1.04-1.29,P=0.009)and calcification ratio >2/3(OR=19.27,95%CI=4.02-92.28,P<0.001)were the factors influencing the disappearance of lesion 12 months after RFA.Conclusions PTC with calcification can be treated with ultrasound-guided RFA.In the case of calcification ratio ≤ 2/3,this therapy demonstrates the effect equivalent to that of no calcification.
Humans
;
Thyroid Cancer, Papillary/surgery*
;
Retrospective Studies
;
Neoplasm Recurrence, Local
;
Radiofrequency Ablation/methods*
;
Calcinosis
;
Thyroid Neoplasms/pathology*
;
Ultrasonography, Interventional
10.Research Progress in the Application of Ultrasound-Guided Robot in Minimally Invasive Surgery.
Acta Academiae Medicinae Sinicae 2023;45(5):853-858
With the continuous advances in modern medical technology and equipment,minimally invasive surgery (MIS) is widely applied in clinical practice.Ultrasound (US) as a real-time,portable,and radiation-free medical imaging method can be used for the intraoperative guidance in MIS to ensure safe and effective surgery.However,the physical characteristics of conventional US fail to display some tissue structures of the human body due to the existence of gas and bone.US-based navigation can make up for the deficiencies by advanced imaging technologies including spatial orientation,image reconstruction,and multi-modality image fusion,being real-time,accurate,and radiation-free.Therefore,US-guided robots can achieve safe,effective,and minimally invasive operation in MIS.This paper reviews the studies of US-guided robots in MIS and prospects the development of this field.
Humans
;
Robotics/methods*
;
Minimally Invasive Surgical Procedures/methods*
;
Ultrasonography
;
Spinal Fusion/methods*
;
Ultrasonography, Interventional/methods*


Result Analysis
Print
Save
E-mail