1.Five new triterpenoid saponins from the kernels of Momordica cochinchinensis
Ru DING ; Jia-qi WANG ; Yi-yang LUO ; Yong-long HAN ; Xiao-bo LI ; Meng-yue WANG
Acta Pharmaceutica Sinica 2025;60(2):442-448
Five saponins were isolated from the kernels of
2.Biomechanical analysis on Vancouver BI periprosthetic femoral fractures fixed by a customized anatomical plate system
Jiaqi WANG ; Xiaozhong LUO ; Yi TONG ; Xiaobo LU ; Weixiang SHI ; Xin ZHOU ; Gang WU ; Yong DING ; Caidong ZHANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3807-3813
BACKGROUND:At present,the use of a locking bone plate combined with steel wire or steel cable for the treatment of periprosthetic femoral fracture often adopts monocortical fixation,which is not stable and the proximal end of the bone cannot be achieved anatomically fitted by plate.The customized anatomical plate system can effectively solve this problem. OBJECTIVE:To explore the biomechanical strength of a customized anatomical plate system in fixation of Vancouver BI periprosthetic femoral fracture. METHODS:CT thin layer scanning data of normal femurs of 1 006 cases were selected and input into the MIMICS 21.0 software to establish the three-dimensional reconstruction model of the femur,which was set as the three-dimensional reconstruction group.56 complete human femoral specimens were selected as the femoral specimen group.The measured results of the two groups for femoral anatomical appearance were compared.If there was no significant difference between the two groups,the approximate appearance of a customized anatomical plate system was designed based on the measurement results in MIMICS 21.0 software and NX11.0 software.The customized anatomical plate system was designed and prepared according to the above measurement results.Eight pairs of frozen human femurs were selected to make Vancouver BI periprosthetic femoral fracture,which of the left were thin layer scanned by dual-source CT to obtain data.The data were transferred to determine the customized anatomical plate system model by the above design software.Eight sets of customized anatomical plate systems were ultimately produced,relying on the instrument company.The eight pairs of models were numbered 1-8.The left side was fixed with the customized anatomical plate system(customized anatomical plate system group);the right side was fixed with a metal locking plate system-large locking plate(claw plate group).L1-L4 and R1-R4 were subjected to vertical short-cycle loading test and vertical loading test.L5-L8 and R5-R8 were subjected to horizontal short-cycle loading test and four-point bending test.The vertical loading test and four-point bending test were used to collect bending load,bending displacement,and bending strain.Two short cycle loading tests were used to collect strain displacement to compare the maximum load,maximum displacement,bending stiffness,and short-period displacement resistance of the two kinds of bone plates. RESULTS AND CONCLUSION:(1)There were no significant differences in all indexes between the three-dimensional reconstruction group and the femoral specimen group(P>0.05).Individual customized anatomical plate system was designed based on the measurement results combined with digital software.(2)In the vertical loading test,the maximum load was higher(P=0.015),the maximum bending displacement was smaller(P=0.014),and the bending stiffness was higher(P=0.005)in the customized anatomical plate system group compared with the claw plate group.(3)In the four-point bending test,the maximum load was higher(P=0.023),the bending stiffness was higher(P=0.005),and the maximum bending displacement was not significant(P=0.216>0.05)in the customized anatomical plate system group compared with the claw plate group.(4)In the vertical short-cycle loading test,the average level of bending displacement in the customized anatomical plate system group(0.23±0.10 mm)was significantly lower than that in the claw plate group(0.44±0.02 mm)(P<0.05).(5)There was no significant difference in the average level of bending displacement between the two groups in the horizontal short cycle loading test(P>0.05).(6)It is concluded that the customized anatomical plate system has personalized anatomical characteristics,and the fixation of Vancouver BI periprosthetic femoral fracture is more stable,which has certain significance for clinical treatment.
3.Pharmacokinetics of single-dose of Etripamil nasal spray in healthy adult Chinese subjects
Wei LIU ; Guo-Ying CAO ; Shu-Yan YU ; Yue-Wen XI ; Jing-Hui LUO ; Bo LIU ; Yu HE ; Tong-Yong FANG ; Xiao-Wen CHEN ; Yuan LI ; Jing ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(13):1948-1952
Objective To evaluate the pharmacokinetics characteristics of single-dose of Etripamil nasal spray 70 mg in healthy adult Chinese subjects.Methods This was a single-center,randomized,double-blind,placebo-controlled study.Twelve healthy adult Chinese subjects were randomized to receive single-dose of Etripamil nasal spray 70 mg(n=10)or placebo nasal spray(n=2).Blood and urine samples were collected prior and post dose.Etripamil in plasma and urine were analyzed by liquid chromatography-tandem mass spectrometry.The pharmacokinetic parameters were calculated by WinNonlin non-compartmental model.Results Following the single-dose of Etripamil nasal spray 70 mg in healthy adult Chinese subjects,the peak concentration of Etripamil in plasma was quickly attained,with a Cmax of(66.76±56.61)ng·mL-1 and a median(range)tmax of 4.00(3.00-5.00)min.The plasma concentrations of Etripamil had fallen approximately 65%from peak value at 25 min after dosing,and close to 80%within 50 min.The AUC0-last and AUC0-∞ were(3 104.16±2 654.46)and(4 048.77±2 682.38)ng·min·mL-1,respectively.The urine excretion percentage of Etripamil during 24 h was(0.01±0.01)%.Among the 12 subjects who were treated with Etripamil or placebo,10 subjects reported a total of 29 treatment-emergent adverse events(TEAEs).All of the TEAEs were mild in severity.The most common TEAEs were rhinorrhoea and lacrimation increased.Conclusion Etripamil was quickly absorbed after intranasal administration,followed by rapid distribution and elimination(not primarily excreted by renal);Etripamil 70 mg was safe and well tolerated by the healthy Chinese adult subjects.
4.Microscopic electric rotary grinding combined with graft repairing in patients with Peyronie's disease:a report of 21 cases
Dachun JIN ; Yong LUO ; Peng WANG ; Yong ZHANG ; Gang BI ; Dali TONG ; Yihe WANG ; Wanyi ZHOU ; Yanfeng LI
Journal of Army Medical University 2024;46(11):1291-1297
Objective To explore the surgical techniques and experiences in the treatment of Peyronie's disease using electric rotary grinding of tunica albuginea plaques followed by graft repair with tunica vaginalis or bovine pericardium under a microscope.Methods A retrospective cohort study was performed on 21 patients with severe penile curvature due to Peyronie's disease admitted in our department from January 2021 and May 2023.All of them underwent microscopic electric rotary grinding of tunica albuginea plaques followed by graft repair surgery.Short-term and mid-term outcomes were observed.Results For the 21 enrolled patients,12(57.1%)underwent repair using unilateral tunica vaginalis,3(14.3%)underwent repair using bilateral tunica vaginalis,and 6(28.6%)underwent repair using bovine pericardium.The operation time was 170~385(average 272±69)min,and the average postoperative follow-up duration was3~24(average 12.1±7.2)months.Seventeen patients(81.0%)had their penis fully extended,while 4 patients(19.0%)had slight dorsal curvature,which was less than 10°.All patients were satisfied with the shape of their penis during erection.The change in penile length was+(1.1±0.5)cm,and 9 patients(42.9%)reported early postoperative penile head numbness,which spontaneously resolved after an average duration of 3.2±1.9 months.All patients were able to successfully engage in sexual activity,with an average penile erection hardness score of 3.8.The overall satisfaction rate was 90.5%post operatively.Conclusion Meticulous dissection of Buck's fascia under a microscope is advantageous in reliably preserving dorsal neurovascular structures.Application of an electric grinding drill for plaque ablation allows for more precise release of the tunica.Graft repair of tunica albuginea defects with testicular tunica vaginalis or bovine pericardium for Peyronie's disease yields overall favorable clinical outcomes and obtains high satisfaction.It is worthy of promotion in clinical practice.
5.Effects of virtual reality in phase I cardiac rehabilitation training for elderly coronary heart disease patients after percutaneous coronary intervention.
Ying WANG ; Sheng-Lan YANG ; Su-Xin LUO ; Hua TONG ; Qin FANG ; Yong-Zheng GUO
Acta Physiologica Sinica 2023;75(6):953-961
The study aimed to examine the effects of virtual reality (VR) technology-based phase I cardiac rehabilitation (CR) program in elderly coronary heart disease (CHD) patients after percutaneous coronary intervention (PCI). Thirty-six cases of elderly CHD patients who underwent PCI in the First Affiliated Hospital of Chongqing Medical University from June 2022 to April 2023 were recruited by convenience sampling method. The patients were randomly assigned by means of random digital table method to two study groups: control group (n = 18), which received conventional nursing intervention after PCI, and experimental group (n = 18), which received a combined program of conventional nursing intervention together with CR program based on VR technology. The 6 min walk test (6MWT), Simple Physical Performance Battery (SPPB), SF-36 scale, Hospital Anxiety and Depression Scale (HADS) and Impact of Events Scale-Revised (IES-R) were tested before and after rehabilitation. Moreover, the incidence of major adverse cardiovascular events (MACE) was recorded at 3 months after PCI. After VR-based CR, the 6MWT distance and SPPB scores of patients in the experimental group were higher than those in control group (P < 0.05). The HADS scores and IES-R scores of the patients in the experimental group were lower than those in control group (P < 0.01), and the difference in SF-36 scale scores was not statistically significant between two groups (P > 0.05). The incidence of MACE was not significantly different at 3 months after PCI (P > 0.05). These results suggest that VR-based phase I CR program mitigates the degree of PCI postoperative stress, anxiety, and depression in elderly CHD patients, however, enhances the resistance to fatigue and does not increase the risk of adverse cardiac events, suggesting it is a safe intervention.
Aged
;
Humans
;
Anxiety
;
Cardiac Rehabilitation/methods*
;
Coronary Disease/surgery*
;
Percutaneous Coronary Intervention/adverse effects*
;
Virtual Reality
6.Quick guideline for diagnosis and treatment of novel coronavirus Omicron variant infection
Guang CHEN ; Tao CHEN ; Sainan SHU ; Xiaojing WANG ; Ke MA ; Di WU ; Hongwu WANG ; Yan LIU ; Wei GUO ; Meifang HAN ; Jianxin SONG ; Tonglin LIU ; Shusheng LI ; Jianping ZHAO ; Yuancheng HUANG ; Yong XIONG ; Zuojiong GONG ; Qiaoxia TONG ; Jiazhi LIAO ; Feng FANG ; Xiaoping LUO ; Qin NING
Chinese Journal of Clinical Infectious Diseases 2023;16(1):26-32
Novel coronavirus Omicron variant infection can cause severe illness and even death in certain populations. Omicron variant infection may lead to systemic inflammatory response, coagulation disorder, multi-organ dysfunction and other pathophysiological changes, which are different from other Novel coronavirus variants to a certain extent, so therapeutic strategies should not be the same. The National Medical Center for Major Public Health Events invited experts in fields of infectious diseases, respiratory medicine, intensive care, pediatrics and fever clinic to develop this quick guideline based on the current best evidence and extensive clinical practices. This quick guideline aims to standardize the diagnosis and treatment of novel coronavirus Omicron infection, and to improve the disease management abilities of clinicians.
7.Clinical and molecular biological characterization of patients with accelerated chronic lymphocytic leukemia.
Zi Yuan ZHOU ; Luo Meng Jia DAI ; Ye Qin SHA ; Tong Lu QIU ; Shu Chao QIN ; Yi MIAO ; Yi XIA ; Wei WU ; Han Ning TANG ; Wei XU ; Jian Yong LI ; Hua Yuan ZHU
Chinese Journal of Hematology 2023;44(11):917-923
Objective: To investigate the clinical and molecular biological characteristics of patients with accelerated chronic lymphocytic leukemia (aCLL) . Methods: From January 2020 to October 2022, the data of 13 patients diagnosed with aCLL at The First Affiliated Hospital of Nanjing Medical University were retrospectively analyzed to explore the clinical and molecular biological characteristics of aCLL. Results: The median age of the patients was 54 (35-72) years. Prior to aCLL, five patients received no treatment for CLL/small lymphocytic lymphoma (SLL), while the other patients received treatment, predominantly with BTK inhibitors. The patients were diagnosed with aCLL through pathological confirmation upon disease progression. Six patients exhibited bulky disease (lesions with a maximum diameter ≥5 cm). Positron emission tomography (PET) -computed tomography (CT) images revealed metabolic heterogeneity, both between and within lesions, and the median maximum standardized uptake value (SUVmax) of the lesion with the most elevated metabolic activity was 6.96 (2.51-11.90). Patients with unmutated IGHV CLL accounted for 76.9% (10/13), and the most frequent genetic and molecular aberrations included +12 [3/7 (42.9% ) ], ATM mutation [6/12 (50% ) ], and NOTCH1 mutation [6/12 (50% ) ]. Twelve patients received subsequent treatment. The overall response rate was 91.7%, and the complete response rate was 58.3%. Five patients experienced disease progression, among which two patients developed Richter transformation. Patients with aCLL with KRAS mutation had worse progression-free survival (7.0 month vs 26.3 months, P=0.015) . Conclusion: Patients with aCLL exhibited a clinically aggressive course, often accompanied by unfavorable prognostic factors, including unmutated IGHV, +12, ATM mutation, and NOTCH1 mutation. Patients with CLL/SLL with clinical suspicion of disease progression, especially those with bulky disease and PET-CT SUVmax ≥5, should undergo biopsy at the site of highest metabolic uptake to establish a definitive pathological diagnosis.
Humans
;
Middle Aged
;
Aged
;
Leukemia, Lymphocytic, Chronic, B-Cell/genetics*
;
Positron Emission Tomography Computed Tomography
;
Retrospective Studies
;
Biopsy
;
Disease Progression
8.Water migration and kinetics of Arecae Semen during moistening process.
Feng-Mei QI ; Xiao-Yong RAO ; Tong-Tong HAN ; Ling-Yun ZHONG ; Xiao-Jian LUO ; Yan HE ; Rui-Lin SHEN
China Journal of Chinese Materia Medica 2022;47(7):1871-1880
In this study, low-field nuclear magnetic resonance(LF-NMR) and magnetic resonance imaging(MRI) were employed to analyze the water distribution, status, and migration in the moistening process of Arecae Semen. Peleg model was adopted to study the water absorption kinetics of Arecae Semen moistened at different water temperatures(10, 30, and 50 ℃). The Arecae Semen samples soaked at different water temperatures all contained four water states: binding water T_(21), non-flowing water T_(22), free water T_(23), and unbound water T_(24). Non-flowing water had the largest increase in peak area during the moistening process, followed by free water. The peak areas of non-flowing water, free water, and total water were correlated with the water content(P<0.01). Therefore, LF-NMR can quickly and non-destructively predict the water content of Arecae Semen during moistening. The peak area of non-flowing water and the content of free water were correlated with the content of arecoline in the soaking solution(P<0.01), which indicated that the faster flow of non-flowing water and more free water corresponded to more arecoline dissolved. The MRI images showed that the water migration pathway varied at different soaking temperatures, and the moistening degree obtained by this means was consistent with that obtained based on traditional experience. The rate constant K_1 fitted by Peleg model decreased with the increase in water temperature, while the capacity constant K_2 showed an opposite trend. The Arrhenius equation fitting of K_1 with temperature showed that the activation energy of Arecae Semen in the moistening process was 32.98 kJ·mol~(-1). LF-NMR/MRI can be used to analyze the water status and content and determine the end moisturing point of Arecae Semen. Peleg model can accurately describe the water absorption properties of Arecae Semen in the moistening process. The findings of this study can guide the moistening optimization and mechanism research of other seed Chinese medicinal materials.
Areca
;
Arecoline/analysis*
;
Drugs, Chinese Herbal/analysis*
;
Kinetics
;
Seeds/chemistry*
;
Water/analysis*
9.Advances in regenerative medicine applications of tetrahedral framework nucleic acid-based nanomaterials: an expert consensus recommendation.
Yunfeng LIN ; Qian LI ; Lihua WANG ; Quanyi GUO ; Shuyun LIU ; Shihui ZHU ; Yu SUN ; Yujiang FAN ; Yong SUN ; Haihang LI ; Xudong TIAN ; Delun LUO ; Sirong SHI
International Journal of Oral Science 2022;14(1):51-51
With the emergence of DNA nanotechnology in the 1980s, self-assembled DNA nanostructures have attracted considerable attention worldwide due to their inherent biocompatibility, unsurpassed programmability, and versatile functions. Especially promising nanostructures are tetrahedral framework nucleic acids (tFNAs), first proposed by Turberfield with the use of a one-step annealing approach. Benefiting from their various merits, such as simple synthesis, high reproducibility, structural stability, cellular internalization, tissue permeability, and editable functionality, tFNAs have been widely applied in the biomedical field as three-dimensional DNA nanomaterials. Surprisingly, tFNAs exhibit positive effects on cellular biological behaviors and tissue regeneration, which may be used to treat inflammatory and degenerative diseases. According to their intended application and carrying capacity, tFNAs could carry functional nucleic acids or therapeutic molecules through extended sequences, sticky-end hybridization, intercalation, and encapsulation based on the Watson and Crick principle. Additionally, dynamic tFNAs also have potential applications in controlled and targeted therapies. This review summarized the latest progress in pure/modified/dynamic tFNAs and demonstrated their regenerative medicine applications. These applications include promoting the regeneration of the bone, cartilage, nerve, skin, vasculature, or muscle and treating diseases such as bone defects, neurological disorders, joint-related inflammatory diseases, periodontitis, and immune diseases.
Nucleic Acids/chemistry*
;
Regenerative Medicine
;
Consensus
;
Reproducibility of Results
;
DNA/chemistry*
10.Endovascular abdominal aortic aneurysm repair with a new stent graft:early results from a multicenter study.
Hong Peng ZHANG ; Xi Wei ZHANG ; Xiang Chen DAI ; Min TIAN ; Bin YANG ; Zhi Wei WANG ; Xiao Jun SHU ; Yu Hong CHEN ; Jian Jun JIANG ; Jian Hua HUANG ; Chang SHU ; Xiao QIN ; Xin Wu LU ; Hong Kun ZHANG ; Wei BI ; Yong LIU ; Bing CHEN ; Zhi Peng HU ; Jian ZUO ; Ping Fan GUO ; Jun LUO ; Xini Yuan TONG ; Wei GUO
Chinese Journal of Surgery 2022;60(12):1049-1056
Objective: To examine the safety and effectiveness of a new stent graft system for endovascular repair of abdominal aortic aneurysm(AAA). Methods: This is a prospective,multi-center,single-arm clinical trial. The patients with AAA treated with a new stent graft system were enrolled at 21 centers from September 2018 to September 2019 in China. Follow-up was performed before discharge, and at 30, 180, 360 days after operation, respectively. The primary safety endpoint was the incidence of major adverse events(MAE) within 30 days. The primary efficacy endpoint was the success rate of AAA treatment at 360 days. Secondary safety endpoints were the incidence of perioperative access complications and acute lower limb ischemia,all-cause mortality, AAA related mortality and incidence of serious adverse events (SAE) at 180 and 360 days. Secondary efficacy endpoints were the incidence of type Ⅰ or Ⅲ endoleak,stent displacement,and conversion to open surgery or re-intervention at 180 and 360 days. Results: One hundred and fifty-six patients were enrolled,including 137 males and 19 females. The age was (68.9±6.9) years (range:48.2 to 84.6 years).Maximum aneurysm diameter was (50.8±11.2) mm (range:25.0 to 85.0 mm),diameter of proximal landing zone was (21.2±2.5) mm (range:17.0 to 29.5 mm),and length of proximal landing zone was (31.4±13.0) mm (range:11.0 to 75.0 mm).The incidence of MAE was 1.3% (2/156) at 30 days,both were all-cause death cases. The success rate of AAA treatment was 88.5% (138/156) at 360 days. No perioperative access complication and acute lower limb ischemia occurred. All-cause mortality was 2.0% (3/154) at 180 days and 2.6% (4/153) at 360 days,and there was no AAA related death. The incidence of SAE was 23.0%(35/152) at 180 days and 30.5%(46/151) at 360 days, and no device-related SAE occurred. The incidence of type Ⅰor Ⅲ endoleak was 3.4% (5/147) at 180 days and 3.5% (5/144) at 360 days. Conclusion: The new stent graft system is easy to operate,and early-term safety and effectiveness results are expected.
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Prospective Studies
;
China
;
Ischemia
;
Aortic Aneurysm, Abdominal/surgery*

Result Analysis
Print
Save
E-mail