1.Roles of A- and C-weighted kurtosis adjustment for equivalent sound level in evaluating occupational hearing loss
Haiying LIU ; Linjie WU ; Yang LI ; Jinzhe LI ; Jiarui XIN ; Hua ZOU ; Wei QIU ; Tong SHEN ; Meibian ZHANG
Journal of Environmental and Occupational Medicine 2025;42(7):793-799
Background Temporal kurtosis (without frequency weighting, i.e., Z-weighted kurtosis) can evaluate noise-induced hearing loss (NIHL). However, few studies have considered the function of frequency weighting (A- or C-weighted) kurtosis on NIHL. Objective To study the significance of A- and C-weighted kurtosis adjustment for equivalent sound level (L'EX,8 h) in evaluating occupational hearing loss. Methods A cross-sectional survey was used to select 973 noise-exposed workers in seven industries as the subjects. The noise exposure of all workers was assessed by distributions of A-, C-, and Z-weighted kurtosis (e.g., KA, KC, and KZ) and respective adjusted equivalent sound level (e.g., L'EX,8 h-KA, L'EX,8 h-KC, and L'EX,8 h-KZ). The significance of A- and C-weighted kurtosis in evaluating NIHL was evaluated by correlations between three types of L'EX,8 h and NIHL, and improvement of noise-induced permanent threshold shift (NIPTS) underestimation predicted by the ISO prediction model (Acoustics—Estimation of noise-induced hearing loss, ISO 1999-2013). Results The median KA, KC, and KZ were 68.33, 28.22, and 19.82, respectively. The binary logistic regression showed that LEX, 8 h-KA, LEX, 8 h-KC, and L'EX, 8 h-KZ were risk factors for NIHL (OR>1, P<0.001). The receiver operating characteristic (ROC) curve showed that when the outcome variable was noise-induced hearing impairment (NIHI), the areas under the curves corresponding to L'EX,8 h-KA, L'EX,8 h-KC, and L'EX,8 h-KZ were 0.625, 0.628, and 0.625, respectively. When the outcome variable was high-frequency noise-induced hearing loss (HFNIHL), the areas under the curves corresponding to L'EX,8 h-KA, L'EX, 8 h-KC, and L'EX,8 h-KZ were 0.624, 0.623, and 0.622, respectively (P<0.05). The order of underestimation improvement values predicted by L'EX,8 h for NIPTS1234 was: L'EX,8 h-KA (4.68 dB HL)>L'EX,8 h-KC (4.38 dB HL)>L'EX,8 h-KZ (4.28 dB HL) (P<0.001). The order of underestimation improvement values predicted by L'EX,8 h-K for NIPTS346 was: L'EX,8 h-KA (7.20 dB HL)>L'EX,8 h-KC (6.83 dB HL)>L'EX,8 h-KZ (6.71 dB HL) (P<0.001). Conclusion The adjustment of A- and C-weighted kurtosis to equivalent sound level LEX,8 h can effectively improve the accuracy of the ISO 1999 prediction model in NIPTS prediction, and compared with the C-weighted, the A-weighted kurtosis can improve the result of the ISO 1999 prediction model in terms of underestimating NIPTS.
2.A novel TNKS/USP25 inhibitor blocks the Wnt pathway to overcome multi-drug resistance in TNKS-overexpressing colorectal cancer.
Hongrui ZHU ; Yamin GAO ; Liyun LIU ; Mengyu TAO ; Xiao LIN ; Yijia CHENG ; Yaoyao SHEN ; Haitao XUE ; Li GUAN ; Huimin ZHAO ; Li LIU ; Shuping WANG ; Fan YANG ; Yongjun ZHOU ; Hongze LIAO ; Fan SUN ; Houwen LIN
Acta Pharmaceutica Sinica B 2024;14(1):207-222
Modulating Tankyrases (TNKS), interactions with USP25 to promote TNKS degradation, rather than inhibiting their enzymatic activities, is emerging as an alternative/specific approach to inhibit the Wnt/β-catenin pathway. Here, we identified UAT-B, a novel neoantimycin analog isolated from Streptomyces conglobatus, as a small-molecule inhibitor of TNKS-USP25 protein-protein interaction (PPI) to overcome multi-drug resistance in colorectal cancer (CRC). The disruption of TNKS-USP25 complex formation by UAT-B led to a significant decrease in TNKS levels, triggering cell apoptosis through modulation of the Wnt/β-catenin pathway. Importantly, UAT-B successfully inhibited the CRC cells growth that harbored high TNKS levels, as demonstrated in various in vitro and in vivo studies utilizing cell line-based and patient-derived xenografts, as well as APCmin/+ spontaneous CRC models. Collectively, these findings suggest that targeting the TNKS-USP25 PPI using a small-molecule inhibitor represents a compelling therapeutic strategy for CRC treatment, and UAT-B emerges as a promising candidate for further preclinical and clinical investigations.
3.Direct Determination of 23 Kinds of Per-and Polyfluoroalkyl Substances in Crude Plant Extracts by Liquid Chromatography-Tandem Mass Spectrometry Coupled with Online Solid Phase Extraction
Nan SHEN ; Tong-Zhu HAN ; Can-Can SHENG ; Xiu-Ping HE ; Jun-Hui CHEN ; Chen-Guang LIU ; Xian-Guo LI
Chinese Journal of Analytical Chemistry 2024;52(2):286-295,后插1-后插5
A new method for simultaneous determination of 23 kinds of per-and polyfluoroalkyl substances(PFASs)(13 kinds of perfluoro carboxylic acids,4 kinds of perfluoro sulfonic acids,and 6 kinds of new substitutes)in plant leaf tissue by ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)using automatic online solid phase extraction(SPE)to remove the matrix interference components in plant crude extracts was developed.The plant leaf samples were extracted twice with 1%formic acid-methanol solution,then evaporated to dry,redissolved with 70%methanol solution,and directly injected for analysis.After 23 kinds of target PFASs were purified automatically by online SPE with a WAX column,the six-way valve was switched to rinse PFASs onto an alkaline mobile phase system-compatible C18 analytical column.Then,the 23 kinds of target PFASs were separated within 16 min by gradient elution using a binary mobile phase system of methanol/water(Containing 0.4%ammonium hydroxide).Tandem mass spectrometry was performed in multiple reaction monitoring(MRM)mode for online detection of various PFASs,and quantification was carried out by internal standard method.The results of the method validation showed that satisfactory average recoveries of 23 kinds of PFASs in plant leaf samples(64.2%-125.5%),precision(relative standard deviations(RSDs)of 0.7%-12.8%),linearity(R2>0.990),and sensitivity(the detection limits(S/N=3)were in the range of 0.02-0.50 μg/kg)were achieved.Finally,this method was used to detect PFASs in the marine green tide algae(Enteromorpha prolifera)and several tree leaves,and a total of 6 kinds of PFASs were detected,in which PFBA was the main contaminant.Compared with the reported offline SPE methods,the proposed online SPE technique significantly simplified the sample pretreatment process and provided an automatic,simple,and environment-friendly method for the routine monitoring of legacy and emerging PFASs in plant tissues.
4.RAS-selective lethal small molecule 3 inhibits the fibrosis of pathological scar fibroblasts
Jiangyong SHEN ; Xi HE ; Yuting TANG ; Jianjun WANG ; Jinyi LIU ; Yuanyuan CHEN ; Xinyi WANG ; Tong LIU ; Haoyuan SUN
Chinese Journal of Tissue Engineering Research 2024;28(8):1168-1173
BACKGROUND:Abnormal extracellular matrix accumulation and excessive proliferation of fibroblasts are the main manifestations of pathological scars.Excessive proliferation of fibroblasts leads to the production of large amounts of collagen-based extracellular matrix.Therefore,to investigate the role of fibroblast fibrosis in the formation of pathological scar will provide a new idea for revealing the mechanism of pathological scar and biological therapy. OBJECTIVE:To investigate the effect of RAS-selective lethal small molecule 3(RSL3)on the fibrosis of human pathological scar fibroblasts. METHODS:Then cases of pathological scar tissue and normal skin tissue samples from the same individuals,provided by the Department of Burn Plastic Surgery,General Hospital of Ningxia Medical University,were collected.Fibroblasts of human pathological scar and human normal skin were extracted and used in the following experiments.The general condition of the pathological scar tissue and the normal skin tissue was detected by hematoxylin-eosin staining.The appearance of fibroblasts from pathological scar and normal skin were observed by inverted microscope.The fibroblasts were verified by immunofluorescence assay.The cells were treated with different concentrations of RSL3(1,3,5,7,9,11,13 μmol/L).The inhibitory concentration of RSL3 on fibroblasts was detected by cell counting kit-8.Control group(without treatment)and RSL3 intervention group(treated with 7 μmol/L RSL3 for 24 hours)were set up.The mRNA and protein expressions of glutathione peroxidase 4,type Ⅰ collagen,type Ⅲ collagen and α-smooth muscle actin were detected by Qrt-PCR and western blot,respectively.Level of malondialdehyde in cells was detected.The residual scratch area was measured by cell scratch test after 24 hours to calculate the percentage of residual scratch area. RESULTS AND CONCLUSION:The expression of glutathione peroxidase 4 in the pathological scar group was higher than that in the normal skin group(Mrna:t=3.252,P<0.01;protein:t=5.075,P<0.01).The expression of glutathione peroxidase 4 in the pathological scar fibroblast group was higher than that in the normal skin fibroblast group(Mrna:t=10.32,P<0.01;protein:t=26.22,P<0.01).Compared with the control group,the expression of glutathione peroxidase 4 was decreased(Mrna:t=2.798,P<0.05;protein:t=4.643,P<0.01),the content of malondialdehyde was increased(t=2.917,P<0.05),the expression of type Ⅰ collagen(Mrna:t=15.84,P<0.01;protein:t=4.610,P<0.01),type Ⅲ collagen(Mrna:t=28.86,P<0.01;protein:t=7.713,P<0.01)and α-smooth muscle actin(Mrna:t=2.671,P<0.05;protein:t=7.417,P<0.01)were decreased in the RSL3 intervention group.Compared with the control group,the migration ability was weakened in the RSL3 intervention group(t=14.06,P<0.01).To conclude,RSL3 can inhibit the expression of glutathione peroxidase 4 and then inhibit the ability of fibrosis and migration of pathological scar fibroblasts.
5.Endo-beta-N-acetylglucosaminidase: Possible Functions and Mechanisms
Xin-Rong LU ; Yong-Liang TONG ; Wei-Li KONG ; Lin ZOU ; Dan-Feng SHEN ; Shao-Xian LÜ ; Rui-Jie LIU ; Shao-Xing ZHANG ; Yu-Xin ZHANG ; Lin-Lin HOU ; Gui-Qin SUN ; Li CHEN
Progress in Biochemistry and Biophysics 2024;51(5):985-999
Endo-beta-N-acetylglucosaminidase (ENGase) is widely distributed in various organisms. The first reported ENGase activity was detected in Diplococcus pneumoniae in 1971. The protein (Endo D) was purified and its peptide sequence was determined in 1974. Three ENGases (Endo F1-F3) were discovered in Flavobacterium meningosepticum from 1982 to 1993. After that, the activity was detected from different species of bacteria, yeast, fungal, plant, mice, human, etc. Multiple ENGases were detected in some species, such as Arabidopsis thaliana and Trichoderma atroviride. The first preliminary crystallographic analysis of ENGase was conducted in 1994. But to date, only a few ENGases structures have been obtained, and the structure of human ENGase is still missing. The currently identified ENGases were distributed in the GH18 or GH85 families in Carbohydrate-Active enZyme (CAZy) database. GH18 ENGase only has hydrolytic activity, but GH85 ENGase has both hydrolytic and transglycosylation activity. Although ENGases of the two families have similar (β/α)8-TIM barrel structures, the active sites are slightly different. ENGase is an effective tool for glycan detection andglycan editing. Biochemically, ENGase can specifically hydrolyze β‑1,4 glycosidic bond between the twoN-acetylglucosamines (GlcNAc) on core pentasaccharide presented on glycopeptides and/or glycoproteins. Different ENGases may have different substrate specificity. The hydrolysis products are oligosaccharide chains and a GlcNAc or glycopeptides or glycoproteins with a GlcNAc. Conditionally, it can use the two products to produce a new glycopeptides or glycoprotein. Although ENGase is a common presentation in cell, its biological function remains unclear. Accumulated evidences demonstrated that ENGase is a none essential gene for living and a key regulator for differentiation. No ENGase gene was detected in the genomes of Saccharomyces cerevisiae and three other yeast species. Its expression was extremely low in lung. As glycoproteins are not produced by prokaryotic cells, a role for nutrition and/or microbial-host interaction was predicted for bacterium produced enzymes. In the embryonic lethality phenotype of the Ngly1-deficient mice can be partially rescued by Engase knockout, suggesting down regulation of Engase might be a solution for stress induced adaptation. Potential impacts of ENGase regulation on health and disease were presented. Rabeprazole, a drug used for stomach pain as a proton inhibitor, was identified as an inhibitor for ENGase. ENGases have been applied in vitro to produce antibodies with a designated glycan. The two step reactions were achieved by a pair of ENGase dominated for hydrolysis of substrate glycoprotein and synthesis of new glycoprotein with a free glycan of designed structure, respectively. In addition, ENGase was also been used in cell surface glycan editing. New application scenarios and new detection methods for glycobiological engineering are quickly opened up by the two functions of ENGase, especially in antibody remodeling and antibody drug conjugates. The discovery, distribution, structure property, enzymatic characteristics and recent researches in topical model organisms of ENGase were reviewed in this paper. Possible biological functions and mechanisms of ENGase, including differentiation, digestion of glycoproteins for nutrition and stress responding were hypothesised. In addition, the role of ENGase in glycan editing and synthetic biology was discussed. We hope this paper may provide insights for ENGase research and lay a solid foundation for applied and translational glycomics.
6.Evaluation of chemiluminescence immunoassay kit for detection of hepatitis D virus IgG antibody
Rongchen YUAN ; Fangming CHENG ; Kuanhui XIANG ; Yongcong LI ; Tianxun HUANG ; Zhenchao TIAN ; Xiongwei LIU ; Xiaozhong WANG ; Zhuanguo WANG ; Yahong MA ; Jing ZHOU ; Erhei DAI ; Chungen QIAN ; Tong LI ; Tao SHEN ; Bangning CHENG
Chinese Journal of Laboratory Medicine 2024;47(3):234-238
Objective:This study evaluates the performance of chemiluminescence assay, which is designed to detect Hepatitis D Virus (HDV) Immunoglobulin G (IgG) antibodies.Methods:A comparative analysis was conducted among chemiluminescence anti-HDV IgG reagent, the magnetic particle-based domestic reagent A and domestic reagent B, and the Robo Gene HDV RNA kit, using 1909 HBsAg-positive plasma samples. This comparison aimed to delineate clinical specificity and detection accuracy. The anti-HDV IgG reagent precision was assessed at three different concentration levels following the Clinical Laboratory Standards Institute EP5-A2 guidelines. The specificity of the assay was validated using 200 HAV IgM positive, 545 HBsAg-positive but anti-HDV IgG-negative, 350 anti HCV positive plasma samples and 200 healthy human blood samples. Additionally, a concordance study was conducted with 545 HBsAg-positive and 37 anti-HDV IgG-positive plasma samples, comparing the anti-HDV IgG reagent against reagent A.Results:1 909 HBsAg-positive plasma samples were tested using 3 anti HDV IgG reagent and 1 HDV RNA reagent, 19 samples were identified as anti-HDV IgG-positive. The anti-HDV IgG demonstrated superior accuracy and specificity. The assay exhibited excellent precision, with intra-assay coefficient of variation (CV) values ranging from 1.57% to 4.30%, and inter-assay CV values between 1.71% and 4.67% for detecting samples at high, medium, and low concentration levels. Concordance with Reagent A showed consistent results in both positive and negative detections.Conclusion:In this study, the anti-HDV IgG reagent (chemiluminescence method) displayed outstanding specificity in detecting clinical samples and exhibited a high conformity rate with commercialized reagents, making it potentially suitable for screening anti-HDV IgG in HBsAg-positive samples.
7.Assessment and preliminary clinical application of a domestic nucleic acid detection reagent for hepatitis D virus
Yongcong LI ; Rongchen YUAN ; Kuanhui XIANG ; Guomin OU ; Tianxun HUANG ; Fangming CHENG ; Zhenchao TIAN ; Xiongwei LIU ; Xiaozhong WANG ; Feng GUO ; Yahong MA ; Jing ZHOU ; Erhei DAI ; Bangning CHENG ; Tong LI ; Tao SHEN ; Chungen QIAN
Chinese Journal of Laboratory Medicine 2024;47(3):239-244
Objective:This study aims to evaluate the quality and explore the preliminary clinical applications of a domestically developed hepatitis D virus nucleic acid quantification reagent (abbreviated as"domestic HDV RNA reagent").Methods:The sensitivity and accuracy of the reagent were evaluated in accordance with the WHO HDV RNA international standard, employing the Bio-Rad CFX Opus 96 real-time fluorescence quantitative PCR analysis system. Serial dilutions of pseudo-viruses or cell culture-derived virus were used to determine the linear range of the domestic HDV RNA reagent. Specificity was assessed using positive samples of HAV, HBV, HCV infection, and HEV national reference materials. Precision was evaluated with samples at both high and low concentrations. In a comparative analysis, 30 HDV IgG positive samples were tested using both the domestic HDV RNA reagent and the RoboGene HDV RNA kit based on the ABI 7500 FAST DX system. The Pearson correlation coefficient (r) was used to examine the correlation between the two reagents.Results:The domestic HDV RNA reagent demonstrated a high sensitivity of up to 6 IU/ml, consistent with that of the comparator reagent. The calibration curve for WHO HDV RNA standards had a slope of -3.286, with an amplification efficiency of 101.6%. The linear detection range spanned from 10 to 10 8 IU/ml for eight HDV genotypes. The domestic HDV RNA reagent exhibited exceptional specificity, without cross-reactivity observed with HAV, HBV, HCV, or HEV. Accuracy assessments at five concentration levels met the required standards, with intra-assay precision coefficient of variation ( CV) ranging from 1.20% to 4.20%, and inter-assay precision CV from 1.20% to 7.90%. The detection results for HDV IgG positive samples were highly correlated with the comparator reagent ( r=0.984, P<0.001), achieving a diagnostic accuracy of 100% compared to sequencing results. Conclusion:In this study, the domestic HDV RNA reagent possesses excellent specificity, accuracy, precision, and a broad linear range, attaining a sensitivity level on par with international reagents of the same type.
8.Diagnostic and intervention value of implantable cardiac monitor in patients over 60 years of age with unexplained syncope
Rui WANG ; Yanfei ZHANG ; Hongchao ZHANG ; Jia WANG ; Shuhui SHEN ; Jiabin TONG ; Junpeng LIU ; You LYU ; Jia CHONG ; Zhilei WANG ; Xin JIN ; Lin SUN ; Xu GAO ; Yan DAI ; Jing LIANG ; Haitao LI ; Tong ZOU ; Jiefu YANG
Chinese Journal of Cardiology 2024;52(7):784-790
Objective:To investigate the value of implantable cardiac monitor (ICM) in the diagnosis and treatment of patients over 60 years old with unexplained syncope.Methods:This was a multi-center, prospective cohort study. Between June 2018 and April 2021, patients over the age of 60 with unexplained syncope at Beijing Hospital, Fuwai Hospital, Beijing Anzhen Hospital and Puren Hospital were enrolled. Patients were divided into 2 groups based on their decision to receive ICM implantation (implantation group and conventional follow-up group). The endpoint was the recurrence of syncope and cardiogenic syncope as determined by positive cardiac arrhythmia events recorded at the ICM or diagnosed during routine follow-up. Kaplan‐Meier survival analysis was used to compare the differences of cumulative diagnostic rate between the 2 groups. A multivariate Cox regression analysis was performed to determine independent predictors of diagnosis of cardiogenic syncope in patients with unexplained syncope.Results:A total of 198 patients with unexplained syncope, aged (72.9±8.25) years, were followed for 558.0 (296.0,877.0) d, including 98 males (49.5%). There were 100 (50.5%) patients in the implantation group and 98 (49.5%) in the conventional follow-up group. Compared with conventional follow-up group, patients in the implantation group were older, more likely to have comorbidities, had a higher proportion of first degree atrioventricular block indicated by baseline electrocardiogram, and had a lower body mass index (all P<0.05). During the follow-up period, positive cardiac arrhythmia events were recorded in 58 (58.0%) patients in the ICM group. The diagnosis rate (42.0% (42/100) vs. 4.1% (4/98), P<0.001) and the intervention rate (37.0% (37/100) vs. 2.0% (2/98), P<0.001) of cardiogenic syncope in the implantation group were higher than those in the conventional follow-up group (all P<0.001). Kaplan-Meier survival analysis showed that the cumulative diagnostic rate of cardiogenic syncope was significantly higher in the implantation group than in the traditional follow-up group ( HR=11.66, 95% CI 6.49-20.98, log-rank P<0.001). Multivariate analysis indicated that ICM implantation, previous atrial fibrillation, diabetes mellitus or first degree atrioventricular block in baseline electrocardiogram were independent predictors for cardiogenic syncope (all P<0.05). Conclusions:ICM implantation improves the diagnosis and intervention rates in patients with unexplained syncope, and increases diagnostic efficiency in patients with unexplained syncope.
9.Research progress on epidemiology of inguinal hernia
Yingmo SHEN ; Xiaoli LIU ; Ruotong ZHENG ; Deyu TONG ; Qiuyue MA
Chinese Journal of Digestive Surgery 2024;23(9):1168-1172
Inguinal hernia is one of the most common surgical diseases, mainly in men and elderly people, and its occurrence and development are related to many risk factors. At present, inguinal hernia can only be cured with surgery, which requires the selection of surgical methods based on patients′ conditions, medical resources and surgeons′ skills. With the aging of the popula-tion, it is expected that the number of inguinal hernia patients will continue to increase. The authors review the epidemiology, risk factors and characteristics of surgical treatment mode of inguinal hernia based on the epidemiological studies of inguinal hernia in recent years.
10.Review of TiRobot orthopedic surgery robot applied in traumatic orthopaedics
Shen LIU ; Tong-Hao LEI ; Feng GU ; Xiang-Dang LIANG ; Xing WEI ; Yong-Hui LIANG
Chinese Medical Equipment Journal 2024;45(5):104-110
The composition and characteristics of TiRobot orthopaedic surgery robot were introduced,and its application in treating traumas was reviewed such as pelvic fracture,acetabular fracture,femoral neck fracture,intertrochanteric fracture,Achilles fracture and navicular fracture.The advantages and disadvantages of TiRobot orthopaedic surgery robot were analyzed when used in the field of traumatic orthopaedics.It's pointed out TiRobot orthopaedic surgery robot be optimized in terms of the existing technical shortcomings and application cost to promote its wide application in the field of traumatic orthopaedics.[Chinese Medical Equipment Journal,2024,45(5):104-110]

Result Analysis
Print
Save
E-mail