1.O-arm navigation versus C-arm navigation for guiding percutaneous long sacroiliac screws placement in treatment of Denis type Ⅱ sacral fractures.
Wei ZHOU ; Guodong WANG ; Xuan PEI ; Zhixun FANG ; Yu CHEN ; Suyaolatu BAO ; Jianan CHEN ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):28-34
OBJECTIVE:
To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.
METHODS:
A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.
RESULTS:
All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).
CONCLUSION
Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.
Humans
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
;
Imaging, Three-Dimensional
;
Bone Screws
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Spinal Fractures/surgery*
;
Fractures, Bone/surgery*
;
Pelvic Bones/injuries*
;
Postoperative Complications
;
Neck Injuries
2.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
3.Effect of arteriosclerotic intracranial arterial vessel wall enhancement on downstream collateral flow.
Liqun YAN ; Jin YAN ; Zhenchang WANG ; Guoshi WANG ; Zhenzhong LI ; Yaping HOU ; Boyuan HUANG ; Qianbo DONG ; Xiaodan MU ; Wei CAO ; Pengfei ZHAO
Chinese Medical Journal 2023;136(18):2221-2228
BACKGROUND:
The effect of arteriosclerotic intracranial arterial vessel wall enhancement (IAVWE) on downstream collateral flow found in vessel wall imaging (VWI) is not clear. Regardless of the mechanism underlying IAVWE on VWI, damage to the patient's nervous system caused by IAVWE is likely achieved by affecting downstream cerebral blood flow. The present study aimed to investigate the effect of arteriosclerotic IAVWE on downstream collateral flow.
METHODS:
The present study recruited 63 consecutive patients at the Second Hospital of Hebei Medical University from January 2021 to November 2021 with underlying atherosclerotic diseases and unilateral middle cerebral artery (MCA) M1-segment stenosis who underwent an magnetic resonance scan within 3 days of symptom onset. The patients were divided into 4 groups according to IAVWE and the stenosis ratio (Group 1, n = 17; Group 2, n = 19; Group 3, n = 13; Group 4, n = 14), and downstream collateral flow was analyzed using three-dimensional pseudocontinuous arterial spin labeling (3D-pCASL) and RAPID software. The National Institutes of Health Stroke Scale (NIHSS) scores of the patients were also recorded. Two-factor multivariate analysis of variance using Pillai's trace was used as the main statistical method.
RESULTS:
No statistically significant difference was found in baseline demographic characteristics among the groups. IAVWE, but not the stenosis ratio, had a statistically significant significance on the late-arriving retrograde flow proportion (LARFP), hypoperfusion intensity ratio (HIR), and NIHSS scores ( F = 20.941, P <0.001, Pillai's trace statistic = 0.567). The between-subject effects test showed that IAVWE had a significant effect on the three dependent variables: LARFP ( R2 = 0.088, F = 10.899, P = 0.002), HIR ( R2 = 0.234, F = 29.354, P <0.001), and NIHSS ( R2 = 114.339, F = 33.338, P <0.001).
CONCLUSIONS:
Arteriosclerotic IAVWE significantly reduced downstream collateral flow and affected relevant neurological deficits. It was an independent factor affecting downstream collateral flow and NIHSS scores, which should be a focus of future studies.
TRIAL REGISTRATION
ChiCTR.org.cn, ChiCTR2100053661.
Humans
;
Constriction, Pathologic/pathology*
;
Magnetic Resonance Imaging/methods*
;
Middle Cerebral Artery/pathology*
;
Tomography, X-Ray Computed
4.Model construction and software design of computed tomography radiation system based on visualization.
Ying LIU ; Ting MENG ; Haowei ZHANG ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):989-995
The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.
Radiation Dosage
;
Software Design
;
Tomography, X-Ray Computed/methods*
;
Software
;
Algorithms
;
Phantoms, Imaging
;
Monte Carlo Method
5.A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications.
Haowei ZHANG ; Shuhan LI ; Ying LIU ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):1012-1018
In recent years, photon-counting computed tomography (PCD-CT) based on photon-counting detectors (PCDs) has become increasingly utilized in clinical practice. Compared with conventional CT, PCD-CT has the potential to achieve micron-level spatial resolution, lower radiation dose, negligible electronic noise, multi-energy imaging, and material identification, etc. This advancement facilitates the promotion of ultra-low dose scans in clinical scenarios, potentially detecting minimal and hidden lesions, thus significantly improving image quality. However, the current state of the art is limited and issues such as charge sharing, pulse pileup, K-escape and count rate drift remain unresolved. These issues could lead to a decrease in image resolution and energy resolution, while an increasing in image noise and ring artifact and so on. This article systematically reviewed the physical principles of PCD-CT, and outlined the structural differences between PCDs and energy integration detectors (EIDs), and the current challenges in the development of PCD-CT. In addition, the advantages and disadvantages of three detector materials were analysed. Then, the clinical benefits of PCD-CT were presented through the clinical application of PCD-CT in the three diseases with the highest mortality rate in China (cardiovascular disease, tumour and respiratory disease). The overall aim of the article is to comprehensively assist medical professionals in understanding the technological innovations and current technical limitations of PCD-CT, while highlighting the urgent problems that PCD-CT needs to address in the coming years.
Tomography, X-Ray Computed/methods*
;
Photons
;
Noise
;
China
;
Phantoms, Imaging
6.Three-dimensional reconstruction of femur based on Laplace operator and statistical shape model.
Zupei ZHANG ; Xiaogang ZHANG ; Yali ZHANG ; Zhongmin JIN
Journal of Biomedical Engineering 2023;40(6):1168-1174
Reconstructing three-dimensional (3D) models from two-dimensional (2D) images is necessary for preoperative planning and the customization of joint prostheses. However, the traditional statistical modeling reconstruction shows a low accuracy due to limited 3D characteristics and information loss. In this study, we proposed a new method to reconstruct the 3D models of femoral images by combining a statistical shape model with Laplacian surface deformation, which greatly improved the accuracy of the reconstruction. In this method, a Laplace operator was introduced to represent the 3D model derived from the statistical shape model. By coordinate transformations in the Laplacian system, novel skeletal features were established and the model was accurately aligned with its 2D image. Finally, 50 femoral models were utilized to verify the effectiveness of this method. The results indicated that the precision of the method was improved by 16.8%-25.9% compared with the traditional statistical shape model reconstruction. Therefore, the method we proposed allows a more accurate 3D bone reconstruction, which facilitates the development of personalized prosthesis design, precise positioning, and quick biomechanical analysis.
Imaging, Three-Dimensional/methods*
;
Tomography, X-Ray Computed/methods*
;
Femur/surgery*
;
Models, Statistical
;
Lower Extremity
7.Research progress on electrical impedance tomography in pulmonary perfusion.
Linjun SHE ; Rui ZHOU ; Pan PAN ; Zhan LI ; Jihong LIU ; Fei XIE
Journal of Biomedical Engineering 2023;40(6):1249-1254
Electrical impedance tomography (EIT) is an emerging technology for real-time monitoring based on the impedance differences of different tissues and organs in the human body. It has been initially applied in clinical research as well as disease diagnosis and treatment. Lung perfusion refers to the blood flow perfusion function of lung tissue, and the occurrence and development of many diseases are closely related to lung perfusion. Therefore, real-time monitoring of lung perfusion is particularly important. The application and development of EIT further promote the monitoring of lung perfusion, and related research has made great progress. This article reviews the principles of EIT imaging, lung perfusion imaging methods, and their clinical applications in recent years, with the aim of providing assistance to clinical and scientific researchers.
Humans
;
Electric Impedance
;
Lung/physiology*
;
Tomography, X-Ray Computed
;
Perfusion
;
Tomography/methods*
8.Short-term efficacy of digitally-assisted traditional Chinese medicine manual reduction combined with 3D printed splint in the treatment of AO type-A distal radius fractures.
Guo-Liang LI ; Jian-Yong ZHAO ; Xiao-Ming LI ; Tie-Qiang WANG ; Kang CHEN ; Qi-Lin LIU
China Journal of Orthopaedics and Traumatology 2023;36(9):809-814
Objective To explore the short-term efficacy of digitally-assisted traditional Chinese medicine manual reduction combined with 3D printed splint in the treatment of AO type-A distal radius fractures, and explore the quantification of traditional Chinese medicine manual reduction and personalized improvement of splinting. Methods The clinical data of 50 patients with AO type-A distal radius fractures, who received treatment at the outpatient department of Cangzhou Integrated Traditional Chinese and Western Medicine Hospital in Hebei Province, were retrospective analyzed. The patient cohort included 22 females and 28 males, with ages ranging from 25 to 75 years old. Among them, 27 cases presented with distal radius fractures on the left side, and 24 cases on the right side. The patients were categorized into two groups: treatment group (n=25) and control group(n=25). There were 13 males and 12 females in the treatment group, with an average age of (56.2±5.5) years old. Treatment approach for this group involved several steps. Initially, Mimics Research software was used to conduct comprehensive analysis of complete CT data from the affected limb, resulting in the creation of a three-dimensional model. Subsequently, 3D models of the bones and skin contours, stored as STL format files, were imported into the Materialise Magics 23.0 software for model processing and repair. This facilitated the simulation of reduction and recording of displacement data, effectively generating a "digital prescription" to guide and quantify traditional Chinese medicine manipulation procedures. Finally, a personalized 3D printed splint was applied for fixation treatment. There were 15 males and 10 females in the control group, with an average age of (53.32±5.28) years old. These patients were treated with manualreduction combined with traditional splinting. The clinical efficacy of the two groups was assessed in terms of fracture reduction quality, fracture healing time, Gartland-Werley wrist joint score and X-ray parameters (palminclination angle, ulnar deviation angle, radius height) at 6 weeks post-operatively. Results The treatment group exhibited a shorter duration for achieving clinical healing compared to the control group (P<0.05). Six weeks post-operatively, the treatment group demonstrated higher wrist joint function scores, and a higher proportion of excellent and good outcomes than the control group(P<0.05). The treatment group was superior to the control group in terms of imaging parameters 6 weeks post-operatively (P<0.05). Conclusion By quantifying skin contours through digital simulation prescription reduction, a personalized 3D printed splint is developed to effectively stabilize fractures, enhancing localized fixation while ensuring greater adherence, stability, and comfort. This innovative approach offers personalized treatment for AO type-A distal radius fractures and presents a novel, precise treatment strategy for consideration.
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
East Asian People
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Splints
;
Wrist Fractures/therapy*
;
Medicine, Chinese Traditional/methods*
;
Therapy, Computer-Assisted/methods*
;
Manipulation, Orthopedic/methods*
;
Tomography, X-Ray Computed
;
Precision Medicine/methods*
9.Discussion on internal fixation of Hoffa fractures.
China Journal of Orthopaedics and Traumatology 2023;36(12):1207-1210
Hoffa fracture is an unstable intra-articular fracture with significant redisplacement tendency. It is easy to be missed diagnosis when accompanied by distal intercondylar or supracondylar fracture of femur. CT scan is the gold standard for the diagnosis of Hoffa fracture. The treatment principles are anatomic reduction of the articular surface, reliable internal fixation, and early functional activity. At present, the main treatment is arthroscopic screw fixation. During screw fixation, the tail cap of screw should be buried, resulting in non-healing iatrogenic injury of articular cartilage. In the early postoperative functional activity of knee joint, fracture block was repeatedly subjected to backward and upward shear force under the action of the tibial plateau, which is the main reason for the failure of internal fixation. Plate assisted screw fixation could increase local mechanical stability, but it still cannot avoid the defects of iatrogenic cartilage injury. At the same time, plate molding is required during the operation due to the absence of special anatomical plates, resulting in increased surgical trauma and time-consuming surgery. The ideal fixation method for Hoffa fracture should include:(1) Avoid iatrogenic injury of articular surface cartilage. (2) With the rear anti-shear barrier plate function.(3) The internal fixator is closer to the load interface, so as to obtain greater load and better fixed strength.
Humans
;
Hoffa Fracture
;
Femoral Fractures/surgery*
;
Tomography, X-Ray Computed
;
Fracture Fixation, Internal/methods*
;
Bone Plates
;
Iatrogenic Disease
10.Comparison of the predictive value of the Helsinki, Rotterdam, and Stockholm CT scores in predicting 6-month outcomes in patients with blunt traumatic brain injuries.
Nushin Moussavi BIUKI ; Hamid Reza TALARI ; Mohammad Hossein TABATABAEI ; Masoumeh ABEDZADEH-KALAHROUDI ; Hossein AKBARI ; Mahsa Masjedi ESFAHANI ; Reihaneh FAGHIHI
Chinese Journal of Traumatology 2023;26(6):357-362
PURPOSE:
Despite advances in modern medicine, traumatic brain injuries (TBIs) are still a major medical problem. Early diagnosis of TBI is crucial for clinical decision-making and prognosis. This study aims to compare the predictive value of Helsinki, Rotterdam, and Stockholm CT scores in predicting the 6-month outcomes in blunt TBI patients.
METHODS:
This cohort study was conducted on blunt TBI patients of 15 years or older. All of them were admitted to the surgical emergency department of Shahid Beheshti Hospital in Kashan, Iran from 2020 to 2021 and had abnormal trauma-related findings on brain CT images. The patients' demographic data such as age, gender, history of comorbid conditions, mechanism of trauma, Glasgow coma scale, CT images, length of hospital stay, and surgical procedures were recorded. The Helsinki, Rotterdam, and Stockholm CT scores were simultaneously determined according to the existing guidelines. The included patients' 6-month outcome was determined using the Glasgow outcome scale extended. M Data were analyzed by SPSS software version 16.0. Sensitivity, specificity, negative/positive predictive value and the area under the receiver operating characteristic curve were calculated for each test. The Kappa agreement coefficient and Kuder Richardson-20 were used to compare the scoring systems.
RESULTS:
Altogether 171 TBI patients met the inclusion and exclusion criteria, with the mean age of (44.9 ± 20.2) years. Most patients were male (80.7%), had traffic related injuries (83.1%) and mild TBIs (64.3%). Patients with lower Glasgow coma scale had higher Helsinki, Rotterdam, and Stockholm CT scores and lower Glasgow outcome scale extended scores. Among all the scoring systems, the Helsinki and Stockholm scores showed the highest agreement in predicting patients' outcomes (kappa = 0.657, p < 0.001). The Rotterdam scoring system had the highest sensitivity (90.1%) in predicting death of TBI patients, whereas the Helsinki scoring system had the highest sensitivity (89.8%) in predicting the 6-month outcome in TBI patients.
CONCLUSION
The Rotterdam scoring system was superior in predicting death in TBI patients, whereas the Helsinki scoring system was more sensitive in predicting the 6-month outcome.