1.Application of Nice knot technique in wound closure of Gustilo type ⅢA and ⅢB open tibial fractures.
Zhipeng YAO ; Minxing WANG ; Wenxiong ZHU ; Shanyi WANG ; Hongxuan HUANG ; Zequn CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):46-50
		                        		
		                        			OBJECTIVE:
		                        			To explore the effectiveness of Nice knot technique for wound closure in Gustilo type ⅢA and ⅢB open tibial fractures.
		                        		
		                        			METHODS:
		                        			A retrospective study was performed on 22 patients with Gustilo type ⅢA and ⅢB open tibial fractures, who underwent wound closure using the Nice knot technique and were admitted between June 2021 and June 2022. There were 15 males and 7 females. The age ranged from 18 to 67 years, with an average of 41.9 years. The causes of injury included traffic accident in 11 cases, falling from height in 7 cases, and heavy object injuries in 4 cases. Fractures were located on the left side in 9 cases and on the right side in 13 cases. And 9 cases were type ⅢA fractures and 13 were type ⅢB fractures according to Gustilo classification. All patients had extensive soft tissue injuries, and no vascular or neurological damage was observed. The time from injury to debridement was 3-8 hours (mean, 6.5 hours). The sizes of wounds before operation and at 2 weeks after operation were measured and wound healing rate at 2 weeks after operation were calculated. The wound healing time and wound healing grading were recorded. The Vancouver Scar Scale (VSS) score was used to assess the wound scar after wound healed and the excellent and good rate was calculated.
		                        		
		                        			RESULTS:
		                        			The wound area was 21.0-180.0 cm 2 (mean, 57.82 cm 2) before operation, and it was 1.2-27.0 cm 2 (mean, 6.57 cm 2) at 2 weeks after operation. The wound healing rate at 2 weeks after operation was 76%-98% (mean, 88.6%). After operation, 2 cases needed to adjust Nice knot due to skin cutting and 1 case occurred soft tissue infection on the wound. The other patient's wounds healed. The average wound healing time was 27.8 days (range, 18-44 days). And the wound healing were grade A in 13 cases and grade B in 9 cases. VSS score was 2-9, with an average of 4.1; 10 cases were rated as excellent, 10 as good, and 2 as poor, with an excellent and good rate of 90.9%. All patients were followed up 9-24 months (mean, 14.6 months). During follow-up, no deep infection or osteomyelitis occurred. Two cases experienced fracture non-union, and were treated with compression fixation and bone grafting. The fractures of the other patients all healed, with a healing time of 85-190 days (mean, 148.2 days).
		                        		
		                        			CONCLUSION
		                        			Nice knot technique can be used in wound closure of Gustilo type ⅢA and ⅢB open tibial fractures effectively, which is easy to operate.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Adolescent
		                        			;
		                        		
		                        			Young Adult
		                        			;
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Cicatrix
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Wound Healing
		                        			;
		                        		
		                        			Fracture Fixation, Internal/methods*
		                        			;
		                        		
		                        			Fractures, Open/surgery*
		                        			
		                        		
		                        	
2.Research progress on biomechanics for internal fixation in tibial plateau fracture.
Jialun LIU ; Yingze ZHANG ; Zhanle ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):113-118
		                        		
		                        			OBJECTIVE:
		                        			To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.
		                        		
		                        			METHODS:
		                        			The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.
		                        		
		                        			RESULTS:
		                        			Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.
		                        		
		                        			CONCLUSION
		                        			Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Biomechanical Phenomena
		                        			;
		                        		
		                        			Bone Plates
		                        			;
		                        		
		                        			Fracture Fixation, Internal
		                        			;
		                        		
		                        			Fracture Fixation, Intramedullary
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Tibial Plateau Fractures
		                        			
		                        		
		                        	
3.Osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in treatment of tibial plateau fractures involving posterolateral column collapse.
Xuan PEI ; Guodong WANG ; Shenglong QIAN ; Yipeng CHENG ; Zhixun FANG ; Xi KE ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):410-416
		                        		
		                        			OBJECTIVE:
		                        			To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.
		                        		
		                        			METHODS:
		                        			A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.
		                        		
		                        			RESULTS:
		                        			All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).
		                        		
		                        			CONCLUSION
		                        			For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Blood Loss, Surgical
		                        			;
		                        		
		                        			Tibial Plateau Fractures
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Bone Plates
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Knee Joint
		                        			;
		                        		
		                        			Fracture Fixation, Internal
		                        			;
		                        		
		                        			Osteotomy
		                        			;
		                        		
		                        			Weight-Bearing
		                        			
		                        		
		                        	
4.A comparative study of absorbable screw fixation and absorbable screw combined with suture anchor fixation in treatment of avulsion fracture of posterior cruciate ligament at tibial insertion of knee joint.
Shuang WU ; Kaibo ZHANG ; Weili FU ; Jian LI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):572-577
		                        		
		                        			OBJECTIVE:
		                        			To compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation.
		                        		
		                        			METHODS:
		                        			The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups ( P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function.
		                        		
		                        			RESULTS:
		                        			There was no significant difference in operation time between the two groups ( P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference ( t=-0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values ( P<0.05). However, there was no significant difference in the improvement value between the two groups ( P>0.05).
		                        		
		                        			CONCLUSION
		                        			For PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Posterior Cruciate Ligament/injuries*
		                        			;
		                        		
		                        			Suture Anchors
		                        			;
		                        		
		                        			Fractures, Avulsion/surgery*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Arthroscopy/methods*
		                        			;
		                        		
		                        			Fracture Fixation, Internal/methods*
		                        			;
		                        		
		                        			Knee Joint/surgery*
		                        			;
		                        		
		                        			Bone Screws
		                        			;
		                        		
		                        			Suture Techniques
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
5.Effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament tibial insertion fracture in adults.
Botao ZHU ; Peilong DONG ; Xiaobo TANG ; Zhiyun LI ; Youhua WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):658-662
		                        		
		                        			OBJECTIVE:
		                        			To explore the effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament (PCL) tibial insertion fractures in adults.
		                        		
		                        			METHODS:
		                        			Between October 2019 and October 2021, 16 patients with PCL tibial insertion fractures were treated with arthroscopic binding fixation using suture through single bone tunnel. There were 11 males and 5 females with an average age of 41.1 years (range, 26-58 years). The fractures were caused by traffic accident in 12 cases and sports in 4 cases. The time from injury to operation ranged from 2 to 10 days with an average of 6.0 days. The fractures were classified as Meyers-McKeever type Ⅱ in 4 cases and type Ⅲ in 9 cases, and Zaricznyi type Ⅳ in 3 cases. There were 2 cases of grade Ⅰ, 7 cases of grade Ⅱ, and 7 cases of grade Ⅲ in the posterior drawer test. There were 3 cases combined with lateral collateral ligament injury and 2 cases with meniscus injury. The visual analogue scale (VAS) score, Lysholm score, International Knee Documentation Committee (IKDC) score, and knee range of motion were used to evaluate knee joint function. The posterior drawer test and knee stability tester (Kneelax 3) were used to evaluate knee joint stability. The X-ray films were used to evaluate fracture reduction and healing.
		                        		
		                        			RESULTS:
		                        			All incisions healed by first intention after operation. There was no incision infection, popliteal neurovascular injury, or deep venous thrombosis of lower limbs. All patients were followed up 6-12 months, with an average of 10 months. X-ray films at 6 months after operation showed the fractures obtained bone union. There were 11 cases of grade 0, 4 cases of gradeⅠ, and 1 case of grade Ⅱin posterior drawer test, showing significant difference when compared with preoperative results ( Z=23.167, P<0.001). The VAS score, Lysholm score, IKDC score, knee range of motion, and the results of Kneelax3 examination all significantly improved when compared with preoperative results ( P<0.05).
		                        		
		                        			CONCLUSION
		                        			For adult patients with PCL tibial insertion fractures, the arthroscopic binding fixation using suture through single bone tunnel has the advantages of minimal trauma, good fracture reduction, reliable fixation, and fewer complications. The patient's knee joint function recovers well.
		                        		
		                        		
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Anterior Cruciate Ligament Injuries/surgery*
		                        			;
		                        		
		                        			Arthroscopy/methods*
		                        			;
		                        		
		                        			Knee Joint/surgery*
		                        			;
		                        		
		                        			Posterior Cruciate Ligament/injuries*
		                        			;
		                        		
		                        			Suture Techniques
		                        			;
		                        		
		                        			Sutures
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Middle Aged
		                        			
		                        		
		                        	
6.Treatment analysis of complex Schatzker type Ⅳ tibial plateau fractures.
Xiao-Bin CHEN ; Meng LU ; Ben XIAO ; Dao-Jing QIU ; Yuan-Ming HE ; Xue-Jun LI
China Journal of Orthopaedics and Traumatology 2023;36(4):308-312
		                        		
		                        			OBJECTIVE:
		                        			To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.
		                        		
		                        			METHODS:
		                        			Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.
		                        		
		                        			RESULTS:
		                        			Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.
		                        		
		                        			CONCLUSION
		                        			Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Young Adult
		                        			;
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Adolescent
		                        			;
		                        		
		                        			Tibial Plateau Fractures
		                        			;
		                        		
		                        			Bone Plates
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Knee Joint/surgery*
		                        			;
		                        		
		                        			Fracture Fixation, Internal/methods*
		                        			;
		                        		
		                        			Retrospective Studies
		                        			
		                        		
		                        	
7.Development and clinical application of a new reduction device for the treatment of tibial plateau fracture under arthroscopic monitoring.
Xing-Rui HUANG ; Yuan-Bin JIANG ; Chong-Shan YANG ; Hao XU ; Shu-Chen FANG ; Xiao-Wei CHEN ; Cheng CHEN ; Hao LI
China Journal of Orthopaedics and Traumatology 2023;36(6):570-573
		                        		
		                        			OBJECTIVE:
		                        			To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.
		                        		
		                        			METHODS:
		                        			From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).
		                        		
		                        			RESULTS:
		                        			All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).
		                        		
		                        			CONCLUSION
		                        			The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Adolescent
		                        			;
		                        		
		                        			Young Adult
		                        			;
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Tibial Plateau Fractures
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Fracture Fixation, Internal/methods*
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Bone Plates
		                        			;
		                        		
		                        			Retrospective Studies
		                        			
		                        		
		                        	
8.Establishment and evaluation of rabbit model of closed tibial fracture.
Wei ZHANG ; Huan LIANG ; Zhi-Chao HUANG ; Rui-Feng ZHAO ; Hong-Gang ZHONG ; Wei-Heng CHEN ; Yu-Feng MA
China Journal of Orthopaedics and Traumatology 2023;36(7):662-668
		                        		
		                        			OBJECTIVE:
		                        			To explore the effect of a modified three-point bending fracture device for establishing a rabbit model of closed tibial fracture.
		                        		
		                        			METHODS:
		                        			The model of closed tibial fracture was established in 40 6-month-old male New Zealand white rabbits with a body weight of 2.5 to 3.0 kg, and the model was verified at 6 weeks after operation. Five rabbits underwent pre modeling without temporary external fixation before modeling, and then were fractured with a modified three-point bending fracture device;35 rabbits underwent formal modeling. Before modeling, needles were inserted, and splints were fixed externally, and then the fracture was performed with a modified three-point bending fracture device. The fracture model and healing process were evaluated by imaging and histopathology at 2 hours, 4 weeks, and 6 weeks after operation.
		                        		
		                        			RESULTS:
		                        			Two hours after modeling, the prefabricated module showed oblique fracture in varying degrees and the broken end shifted significantly;Except for 1 comminuted fracture, 2 curved butterfly fractures and 2 without obvious fracture line, the rest were simple transverse and oblique fractures without obvious displacement in formal modeling group. According to the judgment criteria, the success rate of the model was 85.71%. Four weeks after modeling, the fixed needle and splint of the experimental rabbits were in good position, the fracture alignment was good, the fracture line was blurred, many continuous callus growths could be seen around the fracture end, and the callus density was high. Six weeks after modeling, many thick new bone trabeculae at the fracture, marginal osteoblasts attached, and a small number of macrophages were seen under the microscope. The intramembrane osteogenesis area was in the preparation bone stage, the medullary cavity at the fracture had been partially reopened, the callus was in the absorption plastic stage, and many osteoclasts were visible. The X-ray showed that the fracture line almost disappeared, part of the medullary cavity had been opened, the external callus was reduced around, the callus was in the plastic stage, and the bone cortex was continuous. It suggests that the fracture model showed secondary healing.
		                        		
		                        			CONCLUSION
		                        			The improved three-point bending fracture device can establish a stable rabbit model of closed tibial fracture, and the operation is simple, which meets the requirements of closed fracture model in basic research related to fracture healing.
		                        		
		                        		
		                        		
		                        			Rabbits
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Bony Callus
		                        			;
		                        		
		                        			Fracture Healing
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Osteogenesis
		                        			;
		                        		
		                        			Radiography
		                        			
		                        		
		                        	
9.Arthroscopic fixation of chronic bicruciate tibial avulsion fractures: A case report.
Glen PURNOMO ; Aditya Fuad Robby TRIANGGA ; Satrio Nugroho MAGETSARI ; Jansen LEE ; Jeffry ANDRIANUS
Chinese Journal of Traumatology 2023;26(2):106-110
		                        		
		                        			
		                        			A cruciate ligament avulsion is a much less common form of injury than a cruciate ligament tear. Simultaneous tibial avulsion fractures of both cruciate ligaments occur even more rarely. Over the last decades, many studies have described arthroscopic fixation of acute cruciate tibial avulsion fractures, but arthroscopic treatment in a late presenting patient has not been reported in the literature. This case report presents a 32-year-old female with a chronic tibial avulsion fracture of both anterior cruciate ligament and posterior cruciate ligament. Simultaneous fixation of both fractures was performed arthroscopically at week four post-injury. At one year of follow-up, the patient had demonstrated full knee range of motion and stable knee with no complaints, and achieved excellent clinical outcomes. Radiographs showed union of both fractures, and the patient had resumed high-impact exercises.
		                        		
		                        		
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Adult
		                        			;
		                        		
		                        			Fractures, Avulsion/surgery*
		                        			;
		                        		
		                        			Arthroscopy
		                        			;
		                        		
		                        			Knee Joint/surgery*
		                        			;
		                        		
		                        			Tibia/surgery*
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Suture Techniques
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
10.Efficacy and safety of multiple-dose intravenous tranexamic acid for reducing blood loss in complex tibial plateau fractures: A prospective randomized controlled trial.
Weiguo BAO ; Jiangang ZHOU ; Yong WANG ; Jifeng WANG ; Miao CHU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1055-1061
		                        		
		                        			OBJECTIVE:
		                        			To investigate the efficacy and safety of multiple-dose intravenous tranexamic acid (TXA) for reducing blood loss in complex tibial plateau fractures with open reduction internal fixation by a prospective randomized controlled trial.
		                        		
		                        			METHODS:
		                        			A study was conducted on patients with Schatzker type Ⅳ-Ⅵ tibial plateau fractures admitted between August 2020 and December 2022. Among them, 88 patients met the selection criteria and were included in the study. They were randomly allocated into 3 groups, the control group (28 cases), single-dose TXA group (31 cases), and multiple-dose TXA group (29 cases), using a random number table method. There was no significant difference ( P>0.05) in terms of age, gender, body mass index, the Schatzker type and side of fracture, laboratory examinations [hemoglobin (Hb), activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fib), international normalized ratio (INR), D-dimer, and interleukin 6 (IL-6)], and preoperative blood volume. The control group received intravenous infusion of 100 mL saline at 15 minutes before operation and 3, 6, and 24 hours after the first administration. The single-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at 15 minutes before operation, followed by an equal amount of saline at each time point after the first administration. The multiple-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at each time point. The relevant indicators were recorded and compared between groups to evaluate the effectiveness and safety of TXA, including hospital stays, operation time, occurrence of infection; the occurrence of lower extremity deep vein thrombosis, intermuscular vein thrombosis, and pulmonary embolism at 1 week after operation; the lowest postoperative Hb value and Hb reduction rate, the difference (change value) between pre- and post-operative APTT, PT, Fib, and INR; D-dimer and IL-6 at 24 and 72 hours after operation; total blood loss, intraoperative blood loss, hidden blood loss, drainage flow during 48 hours after operation, and postoperative blood transfusion.
		                        		
		                        			RESULTS:
		                        			① TXA efficacy evaluation: the lowest Hb value in the control group was significantly lower than that in the other two groups ( P<0.05), and there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). The Hb reduction rate, total blood loss, intraoperative blood loss, drainage flow during 48 hours after operation, and hidden blood loss showed a gradual decrease trend in the control group, single-dose TXA group, and multiple-dose TXA group. And differences were significant ( P<0.05) in the Hb reduction rate and drainage flow during 48 hours after operation between groups, and the total blood loss and hidden blood loss between control group and other two groups. ② TXA safety evaluation: no lower extremity deep vein thrombosis or pulmonary embolism occurred in the three groups after operation, but 3, 4, and 2 cases of intermuscular vein thrombosis occurred in the control group, single-dose TXA group, and multiple-dose TXA group, respectively, and the differences in the incidences between groups were not significant ( P>0.05). There was no significant difference in the operation time between groups ( P>0.05). But the length of hospital stay was significantly longer in the control group than in the other groups ( P<0.05); there was no significant difference between the single- and multiple-dose TXA groups ( P>0.05). ③ Effect of TXA on blood coagulation and inflammatory response: the incisions of the 3 groups healed by first intention, and no infections occurred. The differences in the changes of APTT, PT, Fib, and INR between groups were not significant ( P>0.05). The D-dimer and IL-6 in the three groups showed a trend of first increasing and then decreasing over time, and there was a significant difference between different time points in the three groups ( P<0.05). At 24 and 72 hours after operation, there was no significant difference in D-dimer between groups ( P>0.05), while there was a significant difference in IL-6 between groups ( P<0.05).
		                        		
		                        			CONCLUSION
		                        			Multiple intravenous applications of TXA can reduce perioperative blood loss and shorten hospital stays in patients undergoing open reduction and internal fixation of complex tibial plateau fractures, provide additional fibrinolysis control and ameliorate postoperative inflammatory response.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Tranexamic Acid/therapeutic use*
		                        			;
		                        		
		                        			Blood Loss, Surgical/prevention & control*
		                        			;
		                        		
		                        			Interleukin-6
		                        			;
		                        		
		                        			Prospective Studies
		                        			;
		                        		
		                        			Tibial Plateau Fractures
		                        			;
		                        		
		                        			Tibial Fractures/surgery*
		                        			;
		                        		
		                        			Thrombosis
		                        			
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail