1.Integration strategy for chronic disease screening indicators in occupational medical examinations
Tianyang SHEN ; Jiming ZHANG ; Tengxiao SHAN ; Zhijun ZHOU
China Occupational Medicine 2025;52(3):336-340
As the prevalence of chronic diseases increases among occupational populations in China, the focus of occupational health management has shifted from ″occupational disease prevention and control″ to ″occupational disease and chronic disease prevention and control″. At present, occupational medical examinations (OME) are mainly focused on occupational disease prevention and control, and generally lack of chronic disease indicators such as blood lipids and blood glucose, limiting the role of OME in life-cycle health management of workers. To address this gap, it is necessary to incorporate chronic disease screening indicators into OME. Integrating OME and chronic disease screening faces bottlenecks, including concerns about increased operating costs in small- and medium-sized enterprises, and the risk of employment discrimination caused by the leakage of employee health privacy. A tiered strategy is recommended. Incorporating low-cost indicators such as blood lipids, waist circumference into routine examinations, and customizing advanced screening for elder or high-risk position workers. The prioritization of screening indicators can be determined by expert consultation and employer-employee discussions. Meanwhile, the results of chronic disease screening indicators should not be included in occupational health surveillance records to protect workers′ privacy. In summary, expanding OME to cover more chronic disease indicators provides valuable economic and social benefits. In the long run, common chronic disease screening indicators should be included in the regular medical examination indicators of OME, thereby reducing the burden of chronic diseases on occupational populations and promoting the health management of occupational populations.
2.A study on correlation between triglycerides glucose index,remnant cholesterol and diabetic nephropathy
Tianyang GUO ; Hui ZHOU ; Yingying CHENG
Chinese Journal of Clinical Laboratory Science 2024;42(4):256-260
Objective To explore the relationship between the triglyceride-glucose(TyG)index,residual cholesterol(RC)and dia-betic nephropathy(T2DM).Methods A total of 410 patients with T2DM were consecutively selected from the Endocrinology Depart-ment of Jiangsu Provincial Traditional Chinese Medicine Hospital from March 2022 to March 2023.The patients were stratified into three groups based on their morning urinary albumin-to-creatinine ratio(UACR):269 patients were in simple diabetes mellitus(SDM)group,80 in early diabetic nephropathy(EDN)group and 61 in clinical diabetic nephropathy(CDN)group.Comparative an-alyses were conducted on the three groups in terms of gender,age,past medical history,body mass index(BMI),systolic blood pres-sure(SBP),diastolic blood pressure(DBP),fasting blood glucose(FBG),Urea,creatinine(Cr),urinary albumin(UA)total cholesterol(TC),triglycerides(TG),high-density lipoprotein cholesterol(HDL-C),and low-density lipoprotein cholesterol(LDL-C).Additionally,TyG index and RC were calculated.Spearman analysis was employed to evaluate the correlation between UACR and these various parameters.Binary Logistic regression was utilized to identify independent risk factors for diabetic nephropathy(DN).The diagnostic performances of Urea,Cr,TyG index and RC for type 2 diabetic nephropathy were assessed using receiver operating charac-teristic(ROC)curve analyses.Results Compared with SDM group,diabetes duration,SBP,Urea,UA,TG,TC,TyG index and RC showed significant increases in EDN group with statistically significant differences(P<0.05),and diabetes duration,SBP,DBP,Urea,Cr,UA,TG,TC,LDL-C,TyG index and RC in CDN group also exhibited significant increases,with statistically significant differences(P<0.05).Spearman rank correlation analysis revealed a positive correlation between RC and UACR(r=0.278,P<0.001),a positive correlation between TyG index and UACR(r=0.239,P<0.001)and a positive correlation between RC and TyG in-dex(r=0.562,P<0.001).Binary logistic regression analysis showed that diabetes duration,SBP,Urea,Cr,TyG index(OR=2.815,95%CI:1.481-5.349,P=0.002),and RC(OR=2.179,95%CI:1.038-4.574,P=0.04)were independent risk factors for DN.The area under the ROC curve(AUCROC)for RC predicting DN occurrence was 0.670(95%CI:0.616-0.725),while the AUCROC for the TyG index was 0.620(95%CI:0.564-0.676).Conclusion TyG index and RC were significantly correlated with the development of DN in the patients with T2DM,which may early facilitate clinical identification and management for the patients in the risk ofr diabetic kidney disease.
3.A non-contact continuous blood pressure measurement method based on video stream.
Hao YAN ; Xia LI ; Tianyang ZHU ; Xiuqiang CHEN ; Ning GONG ; Qinwu ZHOU
Journal of Biomedical Engineering 2023;40(2):249-256
Hypertension is the primary disease that endangers human health. A convenient and accurate blood pressure measurement method can help to prevent the hypertension. This paper proposed a continuous blood pressure measurement method based on facial video signal. Firstly, color distortion filtering and independent component analysis were used to extract the video pulse wave of the region of interest in the facial video signal, and the multi-dimensional feature extraction of the pulse wave was preformed based on the time-frequency domain and physiological principles; Secondly, an integrated feature selection method was designed to extract the universal optimal feature subset; After that, we compared the single person blood pressure measurement models established by Elman neural network based on particle swarm optimization, support vector machine (SVM) and deep belief network; Finally, we used SVM algorithm to build a general blood pressure prediction model, which was compared and evaluated with the real blood pressure value. The experimental results showed that the blood pressure measurement results based on facial video were in good agreement with the standard blood pressure values. Comparing the estimated blood pressure from the video with standard blood pressure value, the mean absolute error (MAE) of systolic blood pressure was 4.9 mm Hg with a standard deviation (STD) of 5.9 mm Hg, and the MAE of diastolic blood pressure was 4.6 mm Hg with a STD of 5.0 mm Hg, which met the AAMI standards. The non-contact blood pressure measurement method based on video stream proposed in this paper can be used for blood pressure measurement.
Humans
;
Blood Pressure/physiology*
;
Blood Pressure Determination/methods*
;
Algorithms
;
Hypertension/diagnosis*
;
Sexually Transmitted Diseases
4.Silencing of SMAD family member 3 promotes M2 polarization of macrophages and the expression of SMAD7 in rheumatoid arthritis.
Chenchen FEI ; Xi SHEN ; Lei WAN ; Haixia FAN ; Tianyang LIU ; Ming LI ; Lei LIU ; Yao GE ; Qingqing WANG ; Wenjie FAN ; Qian ZHOU
Chinese Journal of Cellular and Molecular Immunology 2023;39(10):904-909
Objective To investigate the effect of SMAD family member 3(SMAD3) silenced by small interfering RNA (siRNA) on macrophage polarization and transforming growth factor β1 (TGF-β1)/ SMAD family signaling pathway in rheumatoid arthritis (RA). Methods RA macrophages co-cultured with rheumatoid arthritis fibroblast-like synoviocytes (RA-FLS) were used as a cell model. TGF-β1 was used to stimulate macrophages, and SMAD3-specific siRNA (si-SMAD3) and negative control siRNA (si-NC) were transfected into human RA macrophages co-cultured in TranswellTM chamber. The expression of SMAD3 mRNA was detected by real-time fluorescence quantitative PCR, and the expression of TGF-β1, SMAD3 and SMAD7 protein was detected by Western blot analysis. The contents of TGF-β1 and IL-23 in cell culture supernatant were determined by ELISA. Cell proliferation was detected by CCK-8 assay. TranswellTM chamber was used to measure cell migration. Results Compared with the model group and the si-NC group, the expression of TGF-β1, SMAD3 mRNA and protein in RA macrophages decreased significantly after silencing SMAD3. In addition, the secretion of IL-23 decreased significantly, and the cell proliferation activity and cell migration were inhibited, with high expression of SMAD7. Conclusion Knockdown of SMAD3 can promote M2 polarization and SMAD7 expression in RA macrophages.
Humans
;
Arthritis, Rheumatoid/genetics*
;
Interleukin-23
;
Macrophages
;
RNA, Messenger
;
RNA, Small Interfering/genetics*
;
Smad7 Protein/genetics*
;
Transforming Growth Factor beta1/genetics*
;
Smad3 Protein/genetics*
;
Gene Silencing
5.Ocular pharmacokinetics of topical administration of butenafine nanomicelles in rabbit eyes
Ping LU ; Zhen LIANG ; Zhen ZHANG ; Jingjing YANG ; Fei SONG ; Jingguo LI ; Tianyang ZHOU ; Junjie ZHANG
Chinese Journal of Experimental Ophthalmology 2020;38(12):1038-1044
Objective:To study the pharmacokinetics of the broad-spectrum antifungal drug butenafine nanomicelles (BTF-NM) after topical instillation.Methods:The self-assembly method was used to prepare BTF-NM.The particle size, Zeta potential, and polydispersity index (PDI) of BTF-NM were measured by a nano-particle size-Zeta potential analyzer, and the encapsulation efficiency was determined by high-performance liquid chromatography (HPLC). Forty-two healthy New Zealand white rabbits without eye disease were randomly divided into the BTF-NM group and the BTF suspension (BTF-S) group.The corresponding drugs were instilled in the conjunctival sac with a single instillation of 50 μl.The 7.5 mm filter paper was placed in the conjunctival sac of rabbit eye for 1 minute at 5, 15, 30, 60, 120, 180, 240 minutes after the administration.Then the rabbits were sacrificed by intravenous injection of 4% sodium pentobarbital solution through the ears of the rabbits.The aqueous humor was extracted and the corneal tissue was dissected.The drug concentration of BTF in different tissues was measured by HPLC.The study was approved by the Life Science Ethics Review Committee of Henan Eye Hospital (No.HNEECA-2019-01).Results:The particle size and PDI of BTF-NM were (15.65±0.04)nm and 0.11±0.01, respectively, the Zeta potential was (-0.29±0.36)mV, the encapsulation rate was (98.38±0.29)%.The peak time of the drug both in tears and corneal tissues after BTF-NM application was 5 minutes.The peak concentrations of the drug in tears and corneas of the BTF-NM group were (485.21±66.29) μg/g and (12.53±2.32) μg/g, which were 5.6 and 78 times than that of the BTF-S group, respectively.Within the observation time, the mass fractions of the drug in tears and corneas of the BTF-NM group at each time point were significantly higher than those of BTF-S group at corresponding time points (all at P<0.01), respectively.The area under the concentration-time curve (AUC) 0-240 minutes in tears and corneas of the BTF-NM group was 7 488.90 (μg/g)·minute and 829.01 (μg/g)·minute, which was 7.2 and 52 times than that of the BTF-S group, respectively.No drugs were detected in the aqueous humor of the BTF-NM group and the BTF-S group. Conclusions:BTF-NM is an ideal agent with a simple preparing process, high drug encapsulation efficiency and small particle size.Compared with BTF suspension, BTF-NM can significantly improve the bioavailability of BTF in rabbit corneas.
6.Ocular pharmacokinetics of econazole solid lipid nanoparticle eye drops after single dose topical administration in rabbits
Zhen LIANG ; Zhen ZHANG ; Jingguo LI ; Jingjing YANG ; Ping LU ; Tianyang ZHOU ; Junjie ZHANG
Chinese Journal of Experimental Ophthalmology 2020;38(12):1032-1037
Objective:To investigate the pharmacokinetics of econazole solid lipid nanoparticles (E-SLNs) after administration of one single dose in rabbit eyes.Methods:E-SLNs with 0.2% econazole was prepared by microemulsion method.Its antifungal activity against Fusarium isolated from the eyes of patients with fungal keratitis was evaluated in vitro and was compared with natamycin eye drops.Four healthy New Zealand white rabbits were assigned to the blank control group without any drug interference during the experimental period, and other matched 21 rabbits were randomized into 7 groups according to the specimen-collected time, with 3 rabbits in each group.E-SLNs of 50 μl was singly applied to conjunctival sac in both eyes in the 21 rabbits, and tear was collected using a filter paper at 5, 15, 30, 60, 90, 120 and 180 minutes following administration of the drug.The cornea specimen was collected at above-mentioned time points respectively.The drug levels in each sample were assayed by high performance liquid chromatography.The accuracy, recovery rate, stability and antifungal activity of the drugs in tear fluid and cornea were detected.This study protocol was approved by the Life Science Ethics Review Committee of Henan Eye Hospital (No.HENNCA-2017-22). Results:For the tear samples and corneal tissue samples, the relative standard deviation ( RSD) of the accuracy of the drug was 2.34%-4.04%; the stability analysis result showed that the RSD of the drugs was less than 10%.The 50% minimum inhibitory concentration (MIC 50) and 90% minimum inhibit concentration (MIC 90) of E-SLNs were 0.37 μg/ml and 0.89 μg/ml, respectively.The MIC 50 and MIC 90 of natamycin were 1.15 μg/ml and 1.70 μg/ml, respectively.After one single dose application of E-SLNs eye drops, the peak time of the drug in tears fluids and cornea of rabbits were 5 minutes and maximum concentrations in tears and cornea were 597.64 μg/g and 33.15 μg/g, respectively. Conclusions:The drug levels in tears and cornea achieved are higher than MIC against Fusarium.
7.The facilitation of corneal permeability of cyclosporine A loaded on chitosan-graft-cyclodextrin copolymers vector
Jingguo LI ; Tianyang ZHOU ; Zhanrong LI ; Zhen LIANG ; Huiyun XIA ; Jijun HE ; Junjie ZHANG
Chinese Journal of Experimental Ophthalmology 2019;36(12):914-919
Objective To investigate the corneal permeability of cyclosprin A (CsA) loaded on polymeric vector after topical application.Methods The grafted copolymer chitosan-graft-cyclodextrin (CS-g-CD) was synthesized,and the physicochemical structures of the polymer were investigated using nuclear magnetic resonance spectroscopy (NMR) and fourier transform infrared spectroscopy (FT-IR).A novel CsA eye drop was prepared using the grafted copolymer as carrier material.The physicochemical properties of eye drop,including drug-loading content,osmotic pressure and viscosity were investigated by high performance liquid chromatography-mass spectrometry (HPLC-MS),osmotic pressure gauge and viscometer,respectively.New Zealand albino rabbits were randomly divided into intact cornea CsA group,epithelium debrided CsA group and epithelium debrided control group.The corneal epithelia of the left eyes was debrided in the cornea epithelium debrided group.Cornea irritation test was performed on New Zealand albino rabbits.The aqueous humor was taken and the corneas were collected at 0.5 hour and 1 hour after instilled.The concentration of CsA was measured by HPLC-MS.Cy5 labeled vector loaded with Coumarin 6 served as model copolymers system,the penetration capabilities of the double fluorescent labeling copolymers system were monitored in vivo using two-photon scanning fluorescence microscopy on murine corneas after topical application.The use and care of the animals complied with Regulations for the Administration of Affair Concerning Experimental Animals by State Science and Technology Commission.Results The polymer of CS-g-CD was successfully synthesized and confirmed using NMR and FT-IR.The drug loading of CsA in eye drop solution was 0.06 %;the osmotic pressure was 305 mOsmol/kg and the viscosity was 36.5 cP.The CsA drug delivery system had a reversible temperature-sensitive drug release behavior and had no obvious irritation on the eyes of New Zealand rabbits.One hour after treatment,the concentration of CsA in the cornea and aqueous humor of epithelium debrided CsA group was (5.88 ± 1.46) μg/g and (149.19 ± 3.93) ng/ml,respectively,which was significantly higher than (3.98 ±0.95) μg/g and (30.25± 11.43) ng/ml in epithelium debrided control group (both at P<0.05);the concentration of CsA in the aqueous humor of intact cornea CsA group was (7.23 ± 1.31)ng/ml,which was significantly lower than that in epithelium debrided CsA group (P<0.05).Polymer vectors were mainly retained in the corneal epithelium,and coumarin 6 gradually diffused into the deep corneal stroma with time.Conclusions The grafted copolymer can load CsA,and the eye drop can effectively overcome the corneal barrier and increase the corneal permeability of CsA.
8.The facilitation of corneal permeability of cyclosporine A loaded on chitosan-graft-cyclodextrin copolymers vector
Jingguo LI ; Tianyang ZHOU ; Zhanrong LI ; Zhen LIANG ; Huiyun XIA ; Jijun HE ; Junjie ZHANG
Chinese Journal of Experimental Ophthalmology 2018;36(12):914-919
Objective To investigate the corneal permeability of cyclosprin A (CsA) loaded on polymeric vector after topical application. Methods The grafted copolymer chitosan.graft.cyclodextrin ( CS.g.CD ) was synthesized, and the physicochemical structures of the polymer were investigated using nuclear magnetic resonance spectroscopy ( NMR) and fourier transform infrared spectroscopy ( FT.IR) . A novel CsA eye drop was prepared using the grafted copolymer as carrier material. The physicochemical properties of eye drop,including drug.loading content, osmotic pressure and viscosity were investigated by high performance liquid chromatography.mass spectrometry ( HPLC.MS) ,osmotic pressure gauge and viscometer,respectively. New Zealand albino rabbits were randomly divided into intact cornea CsA group, epithelium debrided CsA group and epithelium debrided control group. The corneal epithelia of the left eyes was debrided in the cornea epithelium debrided group. Cornea irritation test was performed on New Zealand albino rabbits. The aqueous humor was taken and the corneas were collected at 0. 5 hour and 1 hour after instilled. The concentration of CsA was measured by HPLC.MS. Cy5 labeled vector loaded with Coumarin 6 served as model copolymers system, the penetration capabilities of the double fluorescent labeling copolymers system were monitored in vivo using two.photon scanning fluorescence microscopy on murine corneas after topical application. The use and care of the animals complied with Regulations for the Administration of Affair Concerning Experimental Animals by State Science and Technology Commission. Results The polymer of CS.g.CD was successfully synthesized and confirmed using NMR and FT.IR. The drug loading of CsA in eye drop solution was 0. 06 %;the osmotic pressure was 305 mOsmol/kg and the viscosity was 36. 5 cP. The CsA drug delivery system had a reversible temperature.sensitive drug release behavior and had no obvious irritation on the eyes of New Zealand rabbits. One hour after treatment,the concentration of CsA in the cornea and aqueous humor of epithelium debrided CsA group was (5. 88±1. 46)μg/g and (149. 19±3. 93)ng/ml,respectively,which was significantly higher than (3. 98±0. 95)μg/g and (30. 25±11. 43)ng/ml in epithelium debrided control group (both at P<0. 05);the concentration of CsA in the aqueous humor of intact cornea CsA group was ( 7. 23 ± 1. 31 ) ng/ml, which was significantly lower than that in epithelium debrided CsA group ( P<0. 05 ) . Polymer vectors were mainly retained in the corneal epithelium, and coumarin 6 gradually diffused into the deep corneal stroma with time. Conclusions The grafted copolymer can load CsA,and the eye drop can effectively overcome the corneal barrier and increase the corneal permeability of CsA.
9.Promoting effects of macrogol 15 hydroxystearate micelles on corneal absorption of terbinafine hydrochloride
Tianyang ZHOU ; Huiyun XIA ; Jijun HE ; Junjie ZHANG
Chinese Journal of Experimental Ophthalmology 2017;35(11):1009-1013
Background Macrogol 15 hydroxystearate (HS15) is a novel soft non-ionic surfactant and is widely used to solubilize the poorly soluble drugs due to high drug loading and enhancing permeability ability to hydrophobic drug.However,the delivering effects to cornea of HS15 on terbinafine hydrochloride (TH),a insoluble antifungal agents,is unclear.Objective This study was to investigate the promoting corneal absorption effects of HS15 micelles (HNMs) on TH.Methods TH-HNMs was prepared by a co-solvent method.The hydrodynamic droplet size,polydispersity index,and Zeta potential of TH-HNMs were measured by using a Zetasizer.The shape of the micelles was observed under the transmission electron microscope.The high performance liquid chromatography (HPLC) was employed to detect the in vitro cumulative releasing level of TH in the TH-HNMs and drug entrapment efficiency.TH-HNMs was topically adninistered in eyes of 5 healthy male New Zealand rabbits to evaluate the ocular irritation response.Ninety rabbits were randomized into experimental group and control group,and 50 μl of 0.5% TH-HNMs and 0.5% oily TH were topically administered in the right eyes of the animals in the experimental group and contral group,respectively.The animals were sacrificed 5,15,30,60,90,120,180,240,360 minutes after eye dropping by over anesthetization way and the corneas were harvested,and the TH content in the cornea was detected using HPLC.The study protocal was approved by Life Science Ethic Committee of Henen Eye Hospital.Results The average size and polyolis persital index of TH-HNMs were 13.32 nm and 0.046,respectively,and its average Zeta potential was-0.133 mV.The drug entrapment efficiency was 100%.The release level of TH from the micelles presented a pH-dependent manner.The release level of TH was (95.20±3.20)% in the phosphate buffer with pH 5.0 and (0.17± 0.01)% in the phosphate buffer with pH 7.4.The ocular irritation score was 2,and no visible damage was found around experimental eyes after instillation of TH-HNMs.The peak content of TH in the rabbit cornea 5 minutes was (20.26±2.26)pg/g in the experimental group,which was significantly higher than (1.40± 0.44)μg/g in the control group (t =18.926,P=0.000).The area under the curve (AUC)0.360min of drug concentration-time curve in the experimental group was 1 292.25 μg/(g · min),which was 15.6 times more than the control group.Conclusions TH-HNMs is an ideal agent with a simple preparing process,high drug entrapment efficiency,small size and low ocular irritation.Compared with oily TH,TH-HNMs can effectively enhance the corneal absorption of TH.
10.Concentration Determination of Isavuconazole in Rabbit Cornea by HPLC
Jingjing ZHOU ; Tianyang ZHOU ; Junjie ZHANG
China Pharmacy 2017;28(31):4362-4365
OBJECTIVE:To establish a method for the concentration determination of isavuconazole in rabbit cornea. METH-ODS:HPLC was performed on column of Waters X-Bridge C18 with mobile phase of 0.2% glacial acetic acid-acetonitrile(49:51, V/V)at flow rate of 0.7 mL/min,column temperature was 40 ℃,detection wavelength was 284 nm,and injection volume was 10μL. Fifteen Japanese white rabbits with big ears were selected,50 μL of 0.2% isavuconazole suspension was dropped into eyes, then every 3 rabbits were executed after 5,15,30,60,90 min of administration and cornea samples were taken respectively. The determination of isavuconazole were determined after treating. RESULTS:The isavuconazole in leaching solution showed good lin-ear range in 0.0312-2.24μg/mL(r2=0.9999);oethod recovery rate was 91.7%-105.6%(RSD≤6.88%,n=5);extraction recov-ery rate was 100.50%-106.10%(RSD≤2.16%,n=3);and RSDs of inter-day(n=3)and intra-day(n=3)precision and stabili-ty(n=5)tests were lower than 10%. CONCLUSIONS:The method shows strong specificity,high accuracy,good reproducibili-ty,and can rapidly and accurately determine the concentration of isavuconazole in rabbit cornea.

Result Analysis
Print
Save
E-mail