1.Clinical Observation on 60 Cases of Knee Osteoarthritis Treated with Heat-Sensitive Moxibustion
Lu TIAN ; Hongwu XIE ; Meihua LIU ; Jing ZHANG ; Shaozhong XU ; Changjun LI ; Zhixiong KOU
Journal of Traditional Chinese Medicine 2025;66(5):492-500
ObjectiveTo explore the central neuroregulation mechanism of heat-sensitive moxibustion for knee osteoarthritis on pain relief. MethodsThirty patients who did not have experience of Deqi (得气) during heat-sensitive moxibustion treatment were assigned to the "non-Deqi group", while another 30 patients who had experience of Deqi were assigned to the "Deqi group". Both groups received moxibustion at the left Heding (EX-LE2) acupoint. In the Deqi group, after the patients experienced sensation of Deqi at the acupoint, moxibustion was applied at approximately 3 cm from the skin for 10 minutes; in the non-Deqi group, moxibustion was also applied at approximately 3 cm from the skin for 10 minutes. Both groups received treatment once daily for 10 consecutive days. Knee joint pain was assessed before and after treatment using the visual analog scale (VAS). Resting-state functional magnetic resonance imaging (rs-fMRI) scans were performed on all participants before the first treatment session and after the final session on the 10th day. The fractional amplitude of low-frequency fluctuations (fALFF) maps before and after treatment were processed using the SPM12 module by MATLAB. ResultsAfter treatment, VAS scores in both groups were significantly lower than before treatment (P<0.05 or P<0.01), with the Deqi group showing significantly lower VAS scores than the non-Deqi group (P<0.01). Compared to before treatment, the Deqi group exhibited significant activation in the prefrontal cortex (t = 6.28), white matter (t = 6.36), and left temporal lobe (t = 9.33), while significant inhibition was observed in the occipital lobe (t = -9.86) and right cerebrum (t = -4.54, P<0.01); in the non-Deqi group, significant changes after treatment were observed in the left occipital lobe (t = -6.42), left medial frontal gyrus (t = -4.35), left middle frontal gyrus (t = -4.74), right superior frontal gyrus (t = -4.82), right superior temporal gyrus (t = -6.61), and right cerebellar posterior lobe (t = -8.64), all of which were in inhibited states (P<0.01). Compared to the non-Deqi group, the Deqi group exhibited significant activation after treatment in the external nucleus (t = 5.77), white matter (t = 3.58), right cerebrum (t = 5.84), left cerebellum (t = 5.35), and left cerebrum (t = 4.32), while significant inhibition was observed in the prefrontal cortex (t = -4.16), occipital lobe (t = -4.87), and precentral gyrus (t = -4.46, P<0.01). ConclusionsHeat-sensitive moxibustion provides better analgesic effects for knee osteoarthritis under state of Deqi. Its central neuroregulation mechanism may be related to the involvement of the frontal lobe, temporal lobe, occipital lobe, external nucleus, white matter, right cerebrum, left cerebellum, left cerebrum, and precentral gyrus in modulating pain signals.
2.Experience of WANG Jie in Treating Palpitation by Using the Method of Tonifying the Kidney and Invigorating Blood
Jing TIAN ; Mi DENG ; Luna NIU ; Baoying LI ; Yuling CHA ; Ruowei ZHU ; Lu JING
Journal of Traditional Chinese Medicine 2025;66(10):996-999
To summarize the clinical experience of Professor WANG Jie in treating palpitation using the method of tonifying the kidneys and invigorating blood. It is believed that kidney yang deficiency and heart vessel stasis are the key pathogenesis of palpitation, and it is advocated to treat palpitation by tonifying the kidney and invigorating the blood. Meanwhile,the methods of draining water, dissolving phlegm, and fortifying the spleen to supplement the blood should be applied. For palpitation with kidney yang deficiency and heart vessel stasis with upward water, the treatment could use self-prescribed Bushen Huoxue Lishui Formula (补肾活血利水方); for palpitation with phlegm obstruction in blood vessel, the treatment could use self-prescribed Bushen Huoxue Huatan Formula (补肾活血化痰方); for palpitation with spleen yang deficiency, the treatment could use self-prescribed Bushen Huoxue Jianpi Formula (补肾活血健脾方).
3.Association between QRS voltages and amyloid burden in patients with cardiac amyloidosis.
Jing-Hui LI ; Changcheng LI ; Yucong ZHENG ; Kai YANG ; Yan HUANG ; Huixin ZHANG ; Xianmei LI ; Xiuyu CHEN ; Linlin DAI ; Tian LAN ; Yang SUN ; Minjie LU ; Shihua ZHAO
Chinese Medical Journal 2024;137(3):365-367
4.Application and Biological Evaluation of Magnetic Cell Sorting Technology
Tian HONG ; Jing-Wen LI ; Ren-Ai LI ; Er-Ning CHEN ; Lu-Lu ZHAO ; Mei-Hong DU
Progress in Biochemistry and Biophysics 2024;51(1):123-135
Magnetic cell sorting technology is a highly specific and rapid cell sorting technology using superparamagnetic nanocomposites for cell sorting, which is widely used in immunology, stem cytology, oncology, clinical medicine and other fields. Magnetic cell sorting technology is divided into positive isolation, negative isolation/untouched cell isolation, depletion, multi-step isolation and automated cell separation systems. In this review, we firstly give a brief introduction to the classification and application of magnetic cell sorting technology, then discuss several new techniques and challenges based on magnetic cell sorting in recent years, such as improving the sorting efficiency by improving the structure of magnetic materials and magnetic field structure. The necessity of biological evaluation of magnetic cell sorting products was emphatically analyzed. Through the biological evaluation, the advantages and disadvantages of magnetic cell sorting products can be understood, and the research and development ability could be improved. Therefore, 10 biological evaluation technical parameters related to magnetic cell sorting products were proposed: yield, purity, sterility, cytotoxicity, cell morphology, viability, light scattering characteristics of cells, fluorescent antibody labeling ability of cells, cell activation and cell proliferation. The 10 biological evaluation technical parameters play an important role in promoting the standardized application of magnetic cell sorting.
5.Development of a national health standard:Guideline for pediatric transfusion
Rong HUANG ; Qingnan HE ; Mingyan HEI ; Minghua YANG ; Xiaofan ZHU ; Jun LU ; Xiaojun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jinping LIU ; Jing WANG ; Zhili SHAO ; Mingyi ZHAO ; Jia GUO ; Xiny-In WU ; Jiarui CHEN ; Qirong CHEN ; Rong GUI ; Yongjian GUO
Chinese Journal of Blood Transfusion 2024;37(7):839-844
Children and adults differ significantly in physiology,biochemistry and immune function,which leads to sig-nificant differences in blood transfusion strategies between children and adults.To guide the clinical transfusion practice of pediatric patients and improve the prognosis of children,the National Health Commission organized the formulation and re-lease of the health industry standard Guideline for Pediatric Transfusion(WS/T 795-2022).This paper will briefly introduce some concepts that help understand of the Standard and the preparation process of the Standard,and explain and interpret the preparation of the"scope","general provisions"and"factors to consider"of the Standard,hoping to contribute to the understanding and implementation of the Standard.
6.Discrete element modeling and breakage behavior analysis of oral solid dosage form particles
Lin-xiu LUO ; Tian-bing GUAN ; An-qi LUO ; Zeng LIU ; Yu-ting WANG ; Yan-ling JIANG ; Zheng LU ; Jing-cao TANG ; Shuang-kou CHEN ; Hui-min SUN ; Chuan-yun DAI
Acta Pharmaceutica Sinica 2024;59(4):1057-1066
The breakage pattern of unit particles during the production of oral solid dosage forms (OSD) is closely related to the quality of intermediate or final products. To accurately characterize the particles and study the evolution law of particle breakage, the Bonding model of the discrete element method (DEM) was used to investigate the breakage patterns of model parameters, particle shape and process conditions (loading mode and loading rate) on the dynamic breakage, force-time curve, breakage rate, maximum breakage size ratio and fracture strength of particles. The results showed that the particle breakage force was positively correlated with normal strength and bonded disk scale, negatively correlated with normal stiffness per unit area and tangential stiffness per unit area, and weakly correlated with tangential strength. The particle breakage rate was negatively correlated with the aspect ratio of the particles, and the maximum breakage size ratio was positively correlated with the aspect ratio of the particles; among the three loading modes, the breakage rate of compression breakage model was the largest, the breakage rate of shear breakage model was the second largest, and the breakage rate of wear breakage model was the smallest; the maximum breakage size ratio was positively correlated with the loading rate, the loading mode and the loading rate had no mutual influence on particle breakage rate, but had mutual influence on the maximum breakage size ratio. The research results will provide a theoretical basis for the shift of OSD from batch manufacturing to advanced manufacturing.
7.Functionalized Cadmium-Metal Organic Framework Materials with Azo Bonds for Highly Sensitive Electrochemical Detection of 4-Aminophenol
Lu XU ; Tian-Tian MA ; Yi-Yan BAI ; Jing SU ; Yun-Long FU ; Hai-Ying YANG ; Wen-Juan JI
Chinese Journal of Analytical Chemistry 2024;52(4):587-596
The presence of 4-aminophenol(4-AP)in wastewater from the pharmaceutical industry is a common occurrence due to its role as a byproduct or intermediate during the hydrolysis process of paracetamol metabolism,resulting in significant water pollution.Therefore,it is crucial to employ a straightforward and reliable analytical approach for detecting 4-AP in the environment.In this study,a specific type of metal-organic framework(MOF)material called[Cd4(ABTC)2(H2O)12]n(SXNU-4-Cd,H4ABTC=3,3′,5,5′-azobenzene tetracarboxylic acid)was successfully synthesized,which exhibited a unique two-dimensional layered structure consisting of three intertwined spiral chains forming a distinctive″twist braid″.These layers underwent π-π stacking,creating three-dimensional channels with azo bonds decorating the channel walls.This p-π interaction significantly enhanced the adsorption capacity of SXNU-4-Cd towards 4-AP,thereby improving its recognition sensitivity.The fabricated SXNU-4-Cd/GCE sensor showed high sensitivity towards 4-AP in the linear concentration range of 0.1-130 μmol/L,with a detection limit of 8.6 nmol/L,and also exhibited good anti-interference capability,reproducibility and stability.The SXNU-4-Cd/GCE sensor was successfully used for detecting 4-AP in lake water sample,with spiked recoveries of 95.9%-102.8%.This study introduced a novel technique that utilized pure Cd-MOFs to develop electrochemical sensor capable of effectively detecting 4-AP in water samples.
8.Three-dimensional finite element analysis of lumbar disc herniation under different body positions
Ben-Jing YIN ; Yu LU ; Fu-Tao JI ; Rong-Neng QIU ; Yuan-Yang XIE ; Ge CHEN ; Tian-Li XU ; Chao-Yu BAO ; Ju-Bao LI
China Journal of Orthopaedics and Traumatology 2024;37(6):599-604
Objective To campare biomechanical effects of different postural compression techniques on three-dimensional model of lumbar disc herniation(LDH)by finite element analysis.Methods Lumbar CT image of a 48-year-old female patient with LDH(heighted 163 cm,weighted 53 kg)was collected.Mimics 20.0,Geomagic Studio,Solidwords and other software were used to establish three-dimensional finite element model of LDH on L4,5 segments.Compression techniques under horizon-tal position,30° forward bending and 10° backward extension were simulated respectively.After applying the pressure,the ef-fects of compression techniques under different positions on stress,strain and displacement of various tissues of intervertebral disc and nerve root were observed.Results L4,5 segment finite element model was successfully established,and the model was validated.When compression manipulation was performed on the horizontal position,30° flexion and 10° extension,the annular stress were 0.732,5.929,1.286 MPa,the nucleus pulposus stress were 0.190,1.527,0.295 MPa,and the annular strain were 0.097,0.922 and 0.424,the strain sizes of nucleus pulposus were 0.153,1.222 and 0.282,respectively.The overall displace-ment distance of intervertebral disc on Y direction were-3.707,-18.990,-4.171 mm,and displacement distance of nerve root on Y direction were+7.836,+5.341,+3.859 mm,respectively.The relative displacement distances of nerve root and interverte-bral disc on Y direction were 11.543,24.331 and 8.030 mm,respectively.Conclusion Compression manipulation could make herniated intervertebral disc produce contraction and retraction trend,by increasing the distance between herniated interverte-bral disc and nerve root,to reduce symptoms of nerve compression,to achieve purpose of treatment for patients with LDH,in which the compression manipulation is more effective when the forward flexion is 30°.
9.Molecular Mechanism of Protein C Deficiency Caused by Mutations of PROC Gene N355S,G392E,T314A
Tian-Yi LI ; Miao JIANG ; Lu-Lu HUANG ; Jing-Jing HAN ; Zhen-Ni MA ; Xia BAI ; Li-Jun XIA
Journal of Experimental Hematology 2024;32(6):1834-1840
Objective:To study the molecular mechanism of functional defect of protein C (PC) caused by point mutations of human protein C gene (PROC) N355S,G392E and T314A. Methods:The wild-type and mutant plasmids (PCWT,PCN355S,PCG392E,PCT314A) of PROC gene were constructed and transiently transfected into HEK293 cells. The expression of mutant proteins in vitro were tested. The mRNA level changes of wild-type and mutant PC after 24 h of transfection were detected by real-time PCR. Western blot and ELISA were used to detect the changes of intracellular and extracellular protein levels of wild-type and mutant PC. The supernatant of cells transfected for 24-48 h was concentrated by ultrafiltration. The protein in the concentrated solution was quantified,and PC activation and enzyme kinetics tests were performed. Clustal Omega multiple sequence alignment was used to analyze the conservation of amino acid mutation sites. The effect of mutation on PC protein structure was analyzed by PyMOL software. Results:The relative expression abundances of PROC mRNA in PCN355S,PCG392E and PCT314A groups were 1.14±0.46,0.96±0.08 and 1.08±0.17,respectively,and there were no significant differences compared with 1.02±0.24 in PCWT group (P>0.05). Western blot analysis of the lysates of transfected cells showed that the content of PCT314A recombinant protein slightly decreased and the band became relatively lighter. The ELISA results of the concentrated cell culture supernatants showed that the PC:Ag levels of PCN355S and PCG392E were 98.8%±2.4% and 101.4%±3.1%,respectively,with no significant differences compared with PCWT,while PCT314A decreased compared with PCWT (PC:Ag:88.6%±3.2%) (P<0.05). The results of enzyme kinetics test showed that APCN355S (Km=338.3±43.2,Vmax=2.015±0.12),APCG392E (Km=292.2±28.4,Vmax=1.893±0.07) and APCT314A (Km=299.5±24.6,Vmax=1.775±0.06) showed an increase in Km and a decrease in Vmax compared with APCWT (Km=238.2±4.58,Vmax=3.205±0.06). Multiple sequence alignment suggested that the three mutations be highly conservative in different species. The structural model suggested that the amino acid substitutions of N355S,G392E and T314A mutations collide with the surrounding amino acid groups,causing distortion of the surrounding structure,which may have adverse effects on the folding and biological function of PC. Conclusion:The N355S,G392E and T314A mutations in the PROC gene cause functional defects in PC by weakening the binding between PC and substrate. These three mutations have caused serious spatial collisions in the protein structure,affecting the folding of PC and the reactivity of active sites.
10.Preliminary clinical application of total free-breathing cardiac MR examination
Kai YANG ; Gang YIN ; Jing AN ; Xinling YANG ; Tian LAN ; Shihua ZHAO ; Minjie LU
Chinese Journal of Medical Imaging Technology 2024;40(8):1183-1188
Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion correction T1 and T2 mapping,blood flow imaging,and late gadolinium enhancement scanning were retrospectively enrolled,and the qualities of the above images were evaluated and compared with that of conventional CMR images under breath-holding state.Results No significant difference of imaging quality was found between total free-breathing and conventional breath-holding CMR.The differences of left ventricular ejection fraction,cardiac output,left ventricular end-diastolic volume index and left ventricular mass measured based on CMR images under different breath conditions were limited.Conclusion Total free-breathing CMR was feasible in clinical practice,which could provide"one-stop"evaluation of cardiac structure,function and myocardial histological characteristics,hence having promising clinical prospects.

Result Analysis
Print
Save
E-mail