1.Effect of Acupuncture Combined with Bloodletting and Cupping on the Expression of Coagulation-Complement-Mast Cell Activation Axis-Related Factors in Patients with Chronic Spontaneous Urticaria:Randomize-controlled Study
Yuzhu DU ; Yuqiang XUE ; Xiang LIU ; Yu SHI ; Hongkun LI ; Wenshan LIU ; Zan TIAN ; Yutong HU ; Yanjun WANG
Journal of Traditional Chinese Medicine 2025;66(2):150-156
ObjectiveTo observe the clinical efficacy of acupuncture combined with bloodletting and cupping in the treatment of chronic spontaneous urticaria(CSU) and to explore its potential mechanisms of action. MethodsSeventy CSU patients were randomly divided into loratadine group and acupuncture + bloodletting group, with 35 patients in each group. The loratadine group received oral loratadine tablets, 10 mg once daily in the evening. The acupuncture + bloodletting group received acupuncture at Zhongwan (CV 12), Guanyuan (CV 4), Tianshu (ST 25), Zusanli (ST 36), Sanyinjiao (SP 6), Xuehai (SP 10), Quchi (LI 11), Hegu (LI 4), Taichong (LR 3), Baihui (GV 20), and Shenting (GV 24), once daily,along with bloodletting and cupping at Dazhui (GV 14) and Geshu (BL 17), every other day. Both groups were treated for 4 weeks. The 7-day urticaria activity score(UAS7) was assessed before and after the treatment, and levels of serum immunoglobulin E (IgE), interleukin-4 (IL-4), interleukin-5 (IL-5), eosinophil cationic protein (ECP), plasma tissue factor (TF), activated factor Ⅶ (FⅦa), prothrombin fragment 1+2 (F1+2), D-dimer (D-D) and complement component 5a (C5a) were detected. ResultsA total of 65 patients were included in the final analysis, 32 in the loratadine group and 33 in the acupuncture + bloodletting group. Before treatment, there was no significant difference in UAS7 score, serum IgE, IL-4, IL-5, ECP levels, or plasma TF, FⅦa, F1+2, D-D, C5a levels between groups (P> 0.05). After treatment, both groups showed significant reductions in UAS7 score, serum IgE, IL-4, IL-5, and plasma TF, FⅦa, F1+2, D-D, and C5a levels compared to those before treatment (P<0.01). However, after treatment, there was no significant difference in UAS7 score and serum ECP, IgE, IL-4, IL-5 levels between groups (P>0.05). The acupuncture + bloodletting group showed lower plasma TF, FⅦa, F1+2, D-D and C5a levels compared to the loratadine group (P<0.05 or P<0.01). ConclusionAcupuncture combined with bloodletting and cupping can effectively improve the skin symptoms of CSU patients and reduce the levels of inflammatory factors. The potential mechanism of action may involve the regulation of the coagulation-complement-mast cell activation axis, thereby inhibiting mast cell degranulation.
2.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure
3.Association of NLRP3 genetic variant rs10754555 with early-onset coronary artery disease.
Lingfeng ZHA ; Chengqi XU ; Mengqi WANG ; Shaofang NIE ; Miao YU ; Jiangtao DONG ; Qianwen CHEN ; Tian XIE ; Meilin LIU ; Fen YANG ; Zhengfeng ZHU ; Xin TU ; Qing K WANG ; Zhilei SHAN ; Xiang CHENG
Chinese Medical Journal 2025;138(21):2844-2846
4.YOLOX-SwinT algorithm improves the accuracy of AO/OTA classification of intertrochanteric fractures by orthopedic trauma surgeons.
Xue-Si LIU ; Rui NIE ; Ao-Wen DUAN ; Li YANG ; Xiang LI ; Le-Tian ZHANG ; Guang-Kuo GUO ; Qing-Shan GUO ; Dong-Chu ZHAO ; Yang LI ; He-Hua ZHANG
Chinese Journal of Traumatology 2025;28(1):69-75
PURPOSE:
Intertrochanteric fracture (ITF) classification is crucial for surgical decision-making. However, orthopedic trauma surgeons have shown lower accuracy in ITF classification than expected. The objective of this study was to utilize an artificial intelligence (AI) method to improve the accuracy of ITF classification.
METHODS:
We trained a network called YOLOX-SwinT, which is based on the You Only Look Once X (YOLOX) object detection network with Swin Transformer (SwinT) as the backbone architecture, using 762 radiographic ITF examinations as the training set. Subsequently, we recruited 5 senior orthopedic trauma surgeons (SOTS) and 5 junior orthopedic trauma surgeons (JOTS) to classify the 85 original images in the test set, as well as the images with the prediction results of the network model in sequence. Statistical analysis was performed using the SPSS 20.0 (IBM Corp., Armonk, NY, USA) to compare the differences among the SOTS, JOTS, SOTS + AI, JOTS + AI, SOTS + JOTS, and SOTS + JOTS + AI groups. All images were classified according to the AO/OTA 2018 classification system by 2 experienced trauma surgeons and verified by another expert in this field. Based on the actual clinical needs, after discussion, we integrated 8 subgroups into 5 new subgroups, and the dataset was divided into training, validation, and test sets by the ratio of 8:1:1.
RESULTS:
The mean average precision at the intersection over union (IoU) of 0.5 (mAP50) for subgroup detection reached 90.29%. The classification accuracy values of SOTS, JOTS, SOTS + AI, and JOTS + AI groups were 56.24% ± 4.02%, 35.29% ± 18.07%, 79.53% ± 7.14%, and 71.53% ± 5.22%, respectively. The paired t-test results showed that the difference between the SOTS and SOTS + AI groups was statistically significant, as well as the difference between the JOTS and JOTS + AI groups, and the SOTS + JOTS and SOTS + JOTS + AI groups. Moreover, the difference between the SOTS + JOTS and SOTS + JOTS + AI groups in each subgroup was statistically significant, with all p < 0.05. The independent samples t-test results showed that the difference between the SOTS and JOTS groups was statistically significant, while the difference between the SOTS + AI and JOTS + AI groups was not statistically significant. With the assistance of AI, the subgroup classification accuracy of both SOTS and JOTS was significantly improved, and JOTS achieved the same level as SOTS.
CONCLUSION
In conclusion, the YOLOX-SwinT network algorithm enhances the accuracy of AO/OTA subgroups classification of ITF by orthopedic trauma surgeons.
Humans
;
Hip Fractures/diagnostic imaging*
;
Orthopedic Surgeons
;
Algorithms
;
Artificial Intelligence
5.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
6.International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025).
Sheng-Sheng ZHANG ; Lu-Qing ZHAO ; Xiao-Hua HOU ; Zhao-Xiang BIAN ; Jian-Hua ZHENG ; Hai-He TIAN ; Guan-Hu YANG ; Won-Sook HONG ; Yu-Ying HE ; Li LIU ; Hong SHEN ; Yan-Ping LI ; Sheng XIE ; Jin SHU ; Bin-Fang ZENG ; Jun-Xiang LI ; Zhen LIU ; Zheng-Hua XIAO ; Jing-Dong XIAO ; Pei-Yong ZHENG ; Shao-Gang HUANG ; Sheng-Liang CHEN ; Gui-Jun FEI
Journal of Integrative Medicine 2025;23(5):502-518
Functional dyspepsia (FD), characterized by persistent or recurrent dyspeptic symptoms without identifiable organic, systemic or metabolic causes, is an increasingly recognized global health issue. The objective of this guideline is to equip clinicians and nursing professionals with evidence-based strategies for the management and treatment of adult patients with FD using traditional Chinese medicine (TCM). The Guideline Development Group consulted existing TCM consensus documents on FD and convened a panel of 35 clinicians to generate initial clinical queries. To address these queries, a systematic literature search was conducted across PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), VIP Database, China Biology Medicine (SinoMed) Database, Wanfang Database, Traditional Medicine Research Data Expanded (TMRDE), and the Traditional Chinese Medical Literature Analysis and Retrieval System (TCMLARS). The evidence from the literature was critically appraised using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. The strength of the recommendations was ascertained through a consensus-building process involving TCM and allopathic medicine experts, methodologists, pharmacologists, nursing specialists, and health economists, leveraging their collective expertise and empirical knowledge. The guideline comprises a total of 43 evidence-informed recommendations that span a range of clinical aspects, including the pathogenesis according to TCM, diagnostic approaches, therapeutic interventions, efficacy assessments, and prognostic considerations. Please cite this article as: Zhang SS, Zhao LQ, Hou XH, Bian ZX, Zheng JH, Tian HH, Yang GH, Hong WS, He YY, Liu L, Shen H, Li YP, Xie S, Shu J, Zeng BF, Li JX, Liu Z, Xiao ZH, Xiao JD, Zheng PY, Huang SG, Chen SL, Fei GJ. International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025). J Integr Med. 2025; 23(5):502-518.
Dyspepsia/drug therapy*
;
Humans
;
Medicine, Chinese Traditional/methods*
;
Practice Guidelines as Topic
;
Drugs, Chinese Herbal/therapeutic use*
7.Associations between Pesticide Metabolites and Decreased Estimated Glomerular Filtration Rate Among Solar Greenhouse Workers: A Specialized Farmer Group.
Teng Long YAN ; Xin SONG ; Xiao Dong LIU ; Wu LIU ; Yong Lan CHEN ; Xiao Mei ZHANG ; Xiang Juan MENG ; Bin Shuo HU ; Zhen Xia KOU ; Tian CHEN ; Xiao Jun ZHU
Biomedical and Environmental Sciences 2025;38(2):265-269
8.Analysis of national external quality assessment results for transfusion compatibility test, 2018 to 2023
Junhua HU ; Peng ZHANG ; Jiali LIU ; Zhiguo WANG ; Yanming LIU ; Shengchen TIAN ; Wanru MA ; Xiang LI ; Xuebin ZHAO ; Feng XUE ; Yuntian WANG ; Dong LIN ; Zheng SUN ; Jiwu GONG ; Lin ZHOU
Chinese Journal of Blood Transfusion 2025;38(12):1720-1727
Objective: To analyze the results of national external quality assessment (EQA) for transfusion compatibility test from 2018 to 2023, with the aim of providing references for improving laboratory testing quality and ensuring the safety of clinical blood transfusion. Methods: Three EQA programs were conducted annually, each distributing 22 quality assessment samples. Participating transfusion laboratories were required to complete testing within specified deadlines and to submit results along with documentation of testing methodologies, reagents, and equipment used. National Center for Clinical Laboratories (NCCL) conducted statistical analysis of laboratory results, evaluated testing outcomes and related circumstances, and provided feedback to participating laboratories. EQA data from transfusion laboratories across China from 2018 to 2023 were collected and systematically analyzed. Results: From 2018 to 2023, the qualification rates for all five items (ABO forward typing, ABO reverse typing, Rh blood group typing, antibody screening, and cross-matching) were 67.59%, 77.11%, 77.38%, 72.78%, 79.96%, and 85.16%, respectively. The mean qualification rates for ABO forward typing, ABO reverse typing, RhD blood group typing, antibody screening, and cross-matching over the past six years were 96.25%±0.59%, 90.45%±4.52%, 96.05%±0.71%, 90.88%±2.86%, and 88.34%±3.48%, respectively. The qualification rates in 2019, 2020, 2022, and 2023 all showed a stable trend of "blood stations>tertiary hospitals>secondary hospitals". The mean qualification rate of laboratories in secondary hospitals from 2018 to 2023 was significantly lower than those of laboratories in tertiary hospitals and blood stations (P<0.05), while no significant difference was observed between laboratories in tertiary hospitals and blood stations (P>0.05). The micro column agglutination method was the most widely used in all five tests. In the four test items, namely ABO forward typing, ABO reverse typing, antibody screening, and cross-matching, there was a statistically significant difference in the qualification rate of micro column agglutination method compared to other methods (P<0.05). There was a statistical difference in the qualification rate between manual and automated detection using micro column agglutination method in the cross-matching tests (P<0.05), whereas no significant difference was noted for the other test items (P>0.05). Conclusion: From 2018 to 2023, the number of laboratories participating in EQA activities has been increasing year by year, and the qualification rate has shown an overall upward trend. The type of laboratory is a key factor affecting the qualification rate, and the testing capabilities of some laboratories still need to be improved. The micro column agglutination method is widely used in transfusion compatibility tests. The established EQA program effectively monitors quality issues in laboratories, drives continuous improvement, and ensures sustained enhancement of testing standards to safeguard clinical blood safety.
9.Characteristics of Emergency Health Systems Guidance Based on AGREE-HS
Danping ZHENG ; Wei YANG ; Nannan SHI ; Dongfeng WEI ; An LI ; Gezhi ZHANG ; Xue CHEN ; Fangqi LIU ; Zhaoshuai YAN ; Weixuan BAI ; Xinghua XIANG ; Yaxin TIAN ; Mengyu LIU ; Huamin ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(22):137-148
This study used the Appraisal of Guidelines Research & Evaluation-Health Systems (AGREE-HS) to demonstratively compare 34 global coronavirus disease-2019 (COVID-19) health systems guidance documents (HSGs) and 6 World Health Organization (WHO) standard HSGs. The comparison involved topic, participants, methods, recommendations, and implementability, with the aim of exploring the characteristics of emergency HSGs. The results showed that the emergency HSGs had an overall average score of 49%, with topic having the highest score, recommendations having the second highest score, and participants having the lowest score. The standard HSGs had an overall average score of 79%, with high scores in all items. The emergency HSGs had lower scores in participants, methods, recommendations, and implementability than the standard HSGs (P<0.001), while the COVID-19 emergency HSGs developed by the WHO had higher score in topic than the standard HSGs (P<0.05). Compared with those released by countries, the COVID-19 emergency HSG developed by the WHO showed superiority in all items and overall scores (P=0.000 2). This indicates that emergency HSGs, represented by the COVID-19 emergency HSG, place equal emphasis on topic and recommendations as standard HSGs but have low requirements in terms of expert participation, evidence support, and comprehensive consideration in the time- and resource-limited context. They have the characteristics of prominent topics, clear purposes, orientation to demand, keeping up with the latest evidence, flexible adjustment, and timeliness, emphasizing immediate implementation effects, weakening long-term effects, and focusing on comprehensive benefits. Additionally, developers, types, and report completeness are important influencing factors.
10.Evaluation of chemiluminescence immunoassay kit for detection of hepatitis D virus IgG antibody
Rongchen YUAN ; Fangming CHENG ; Kuanhui XIANG ; Yongcong LI ; Tianxun HUANG ; Zhenchao TIAN ; Xiongwei LIU ; Xiaozhong WANG ; Zhuanguo WANG ; Yahong MA ; Jing ZHOU ; Erhei DAI ; Chungen QIAN ; Tong LI ; Tao SHEN ; Bangning CHENG
Chinese Journal of Laboratory Medicine 2024;47(3):234-238
Objective:This study evaluates the performance of chemiluminescence assay, which is designed to detect Hepatitis D Virus (HDV) Immunoglobulin G (IgG) antibodies.Methods:A comparative analysis was conducted among chemiluminescence anti-HDV IgG reagent, the magnetic particle-based domestic reagent A and domestic reagent B, and the Robo Gene HDV RNA kit, using 1909 HBsAg-positive plasma samples. This comparison aimed to delineate clinical specificity and detection accuracy. The anti-HDV IgG reagent precision was assessed at three different concentration levels following the Clinical Laboratory Standards Institute EP5-A2 guidelines. The specificity of the assay was validated using 200 HAV IgM positive, 545 HBsAg-positive but anti-HDV IgG-negative, 350 anti HCV positive plasma samples and 200 healthy human blood samples. Additionally, a concordance study was conducted with 545 HBsAg-positive and 37 anti-HDV IgG-positive plasma samples, comparing the anti-HDV IgG reagent against reagent A.Results:1 909 HBsAg-positive plasma samples were tested using 3 anti HDV IgG reagent and 1 HDV RNA reagent, 19 samples were identified as anti-HDV IgG-positive. The anti-HDV IgG demonstrated superior accuracy and specificity. The assay exhibited excellent precision, with intra-assay coefficient of variation (CV) values ranging from 1.57% to 4.30%, and inter-assay CV values between 1.71% and 4.67% for detecting samples at high, medium, and low concentration levels. Concordance with Reagent A showed consistent results in both positive and negative detections.Conclusion:In this study, the anti-HDV IgG reagent (chemiluminescence method) displayed outstanding specificity in detecting clinical samples and exhibited a high conformity rate with commercialized reagents, making it potentially suitable for screening anti-HDV IgG in HBsAg-positive samples.

Result Analysis
Print
Save
E-mail