1.Psychometric properties of the Chinese version of the Self-Confidence Scale for Clean Intermittent Self-Catheterization
Sufang QIN ; Lina ZHAO ; Lifan ZHANG ; Kaixia GAO ; Bin ZHANG ; Zhuolun TIAN ; Junping GAO
Chinese Journal of Modern Nursing 2024;30(25):3395-3401
		                        		
		                        			
		                        			Objective:To translate the Self-Confidence Scale for Clean Intermittent Self-Catheterization (SCSCISC) into Chinese and test its reliability and validity.Methods:Following the Brislin questionnaire translation principles, the English version of SCCSISC was translated, back translated, culturally adapted, consulted with experts, and pre-surveyed to form the Chinese version of SCCSISC. From June to September 2023, 237 patients with neurogenic bladder admitted to the First Hospital of Shanxi Medical University were selected as survey subjects by the convenient sampling method. The critical ratio method was used for project analysis, and Cronbach's α coefficient, split half reliability, and test-retest reliability were used to evaluate the reliability of the scale. Content validity and construct validity were used to test the validity of the scale.Results:The Cronbach's α coefficient of the Chinese version of SCCSISC was 0.976, the split half coefficient was 0.962, and the test-retest reliability was 0.876. The item-level content validity index ( I- CVI) of the Chinese version of SCCSISC was 0.86 to 1.00, and the scale-level content validity index ( S- CVI) was 0.93, with Kappa consistency coefficients above 0.74. Two common factors were extracted through exploratory factor analysis, with a cumulative variance contribution rate of 73.42%. Conclusions:The Chinese version of SCCSISC has good reliability and validity, and can be used as a tool for self-confidence measurement of clean intermittent self-catheterization among patients with neurogenic bladder in China.
		                        		
		                        		
		                        		
		                        	
2.Lack of CFAP54 causes primary ciliary dyskinesia in a mouse model and human patients.
Xinyue ZHAO ; Haijun GE ; Wenshuai XU ; Chongsheng CHENG ; Wangji ZHOU ; Yan XU ; Junping FAN ; Yaping LIU ; Xinlun TIAN ; Kai-Feng XU ; Xue ZHANG
Frontiers of Medicine 2023;17(6):1236-1249
		                        		
		                        			
		                        			Primary ciliary dyskinesia (PCD) is a highly heterogeneous recessive inherited disorder. FAP54, the homolog of CFAP54 in Chlamydomonas reinhardtii, was previously demonstrated as the C1d projection of the central microtubule apparatus of flagella. A Cfap54 knockout mouse model was then reported to have PCD-relevant phenotypes. Through whole-exome sequencing, compound heterozygous variants c.2649_2657delinC (p. E883Dfs*47) and c.7312_7313insCGCAGGCTGAATTCTTGG (p. T2438delinsTQAEFLA) in a new suspected PCD-relevant gene, CFAP54, were identified in an individual with PCD. Two missense variants, c.4112A>C (p. E1371A) and c.6559C>T (p. P2187S), in CFAP54 were detected in another unrelated patient. In this study, a minigene assay was conducted on the frameshift mutation showing a reduction in mRNA expression. In addition, a CFAP54 in-frame variant knock-in mouse model was established, which recapitulated the typical symptoms of PCD, including hydrocephalus, infertility, and mucus accumulation in nasal sinuses. Correspondingly, two missense variants were deleterious, with a dramatic reduction in mRNA abundance from bronchial tissue and sperm. The identification of PCD-causing variants of CFAP54 in two unrelated patients with PCD for the first time provides strong supportive evidence that CFAP54 is a new PCD-causing gene. This study further helps expand the disease-associated gene spectrum and improve genetic testing for PCD diagnosis in the future.
		                        		
		                        		
		                        		
		                        			Mice
		                        			;
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Kartagener Syndrome/metabolism*
		                        			;
		                        		
		                        			Cilia/metabolism*
		                        			;
		                        		
		                        			Semen
		                        			;
		                        		
		                        			Genetic Testing
		                        			;
		                        		
		                        			RNA, Messenger
		                        			;
		                        		
		                        			Mutation
		                        			
		                        		
		                        	
3.Effects of different radiation doses on the accuracy of quantitative iodine concentration and CT value of virtual monochromatic image in second-generation dual-layer detector spectral CT
Qiaoling WU ; Junping TIAN ; Daming ZHANG ; Zhengyu JIN ; Xiaomei LU ; Shenghui YU ; Yun WANG
Basic & Clinical Medicine 2023;43(12):1866-1870
		                        		
		                        			
		                        			Objective To investigate the effect of different radiation doses on the accuracy of iodine quantification and CT value of virtual monochromatic image with a muti-spectral CT iodine phantom using second-generation dual-layer detector spectral CT(DLCT).Methods The second-generation DLCT scan abdominal phantom was used,which consisted of six different concentrations of iodine rods at 4,8 and 12 g/L.The scan parameters were set at 100,120 and 140 kVp tube voltages,and six radiation exposure sequences were scanned at each tube voltage:5,10,15,20,25 and 30 mGy.Measure the iodine concentration value and the CT value at the single level of 50,70 and 100 keV,and calculate the absolute error value of iodine concentration and CT value under different radiation exposure.SPSS 22.0 software single factor analysis of variance was used to compare the difference between the io-dine concentration and the absolute error of CT value under different Radiation exposure,and LSD method was used to compare the two groups.Results The absolute error of CT value of 4 g/L iodine rod with 10~30 mGy scanning at 100 keV energy level was significantly higher than that of 12 g/L and 8 g/L(P<0.05),and the absolute error of iodine concentration measurement of other iodine rods with different concentrations at different Radiation exposure had no statistical difference.Conclusions The second-generation double-layer detector spectral CT has high meas-urement stability for iodine concentration quantification and CT value accuracy under conditions of radiation dose greater than 5 mGy.
		                        		
		                        		
		                        		
		                        	
4.Reliability and validity of the Chinese version of Intermittent Catheterization Difficulty Questionnaire
Sufang QIN ; Tiantian CUI ; Kaixia GAO ; Bin ZHANG ; Zhuolun TIAN ; Junping GAO ; Xiaomei ZHAI ; Hua ZHAO ; Haiyan TIAN ; Jie WANG
Chinese Journal of Modern Nursing 2023;29(30):4108-4115
		                        		
		                        			
		                        			Objective:To translate the Intermittent Catheterization Difficulty Questionnaire (ICDQ) into Chinese, and to test its reliability and validity in neurogenic bladder patients.Methods:After translation, back-translation, cross-cultural debugging, expert consultation and pre-investigation, a Chinese version of ICDQ was formed. A total of 248 patients with neurogenic bladder clean intermittent self-catheterization who were treated and followed up in the First Hospital of Shanxi Medical University in October 2022 were selected as research objects by the convenient sampling method, and the Chinese version of ICDQ was used for investigation. The critical ratio method was used for project analysis. Content validity and structure validity were used to test the validity of the questionnaire. Cronbach's α coefficient, split half reliability coefficient and retest reliability coefficient were used to test the reliability of the questionnaire. A total of 248 questionnaires were sent out in this study, and 238 were effectively collected, with a recovery rate of 95.97% (238/248) .Results:The Cronbach's α coefficient of the Chinese version of ICDQ was 0.857, the split half coefficient was 0.711, and the retest reliability coefficient was 0.954. The content validity index of the Chinese version of ICDQ item level was 0.860 to 1.000, and the content validity index of the scale level was 0.930. Seven common factors were extracted by exploratory factor analysis, and the cumulative variance contribution rate was 77.38%. The results of confirmatory factor analysis showed RMSEA < 0.080, GFI, AGFI, TLI, CFI > 0.800. Conclusions:Through confirmatory factor analysis, the Chinese version of ICDQ shows that the model fitting indicators of the scale meet the corresponding requirements, indicating that the scale has high structural validity and overall model fitting. It can be used as an evaluation tool for intermittent self catheterization difficulties in patients with neurogenic bladder.
		                        		
		                        		
		                        		
		                        	
5.Status of HVPG clinical application in China in 2021
Wen ZHANG ; Fuquan LIU ; Linpeng ZHANG ; Huiguo DING ; Yuzheng ZHUGE ; Jitao WANG ; Lei LI ; Guangchuan WANG ; Hao WU ; Hui LI ; Guohong CAO ; Xuefeng LU ; Derun KONG ; Lin SUN ; Wei WU ; Junhui SUN ; Jiangtao LIU ; He ZHU ; Dongliang LI ; Wuhua GUO ; Hui XUE ; Yu WANG ; Jiancuo GENGZANG ; Tian ZHAO ; Min YUAN ; Shirong LIU ; Hui HUAN ; Meng NIU ; Xin LI ; Jun MA ; Qingliang ZHU ; Wenbo GUO ; Kunpeng ZHANG ; Xiaoliang ZHU ; Birun HUANG ; Jianan LI ; Weidong WANG ; Hongfeng YI ; Qi ZHANG ; Long GAO ; Guo ZHANG ; Zhongwei ZHAO ; Kai XIONG ; Zexin WANG ; Hong SHAN ; Mingsheng LI ; Xueqiang ZHANG ; Haibin SHI ; Xiaogang HU ; Kangshun ZHU ; Zhanguo ZHANG ; Hong JIANG ; Jianbo ZHAO ; Mingsheng HUANG ; Wenyong SHEN ; Lin ZHANG ; Feng XIE ; Zhiwei LI ; Changlong HOU ; Shengjuan HU ; Jianwei LU ; Xudong CUI ; Ting LU ; Shaoqi YANG ; Wei LIU ; Junping SHI ; Yanming LEI ; Jinlun BAO ; Tao WANG ; Weixin REN ; Xiaoli ZHU ; Yong WANG ; Lei YU ; Qiang YU ; Huiling XIANG ; Wenqiang LUO ; Xiaolong QI
Chinese Journal of Hepatology 2022;30(6):637-643
		                        		
		                        			
		                        			Objective:The investigation and research on the application status of Hepatic Venous Pressure Gradient (HVPG) is very important to understand the real situation and future development of this technology in China.Methods:This study comprehensively investigated the basic situation of HVPG technology in China, including hospital distribution, hospital level, annual number of cases, catheters used, average cost, indications and existing problems.Results:According to the survey, there were 70 hospitals in China carrying out HVPG technology in 2021, distributed in 28 provinces (autonomous regions and municipalities directly under the central Government). A total of 4 398 cases of HVPG were performed in all the surveyed hospitals in 2021, of which 2 291 cases (52.1%) were tested by HVPG alone. The average cost of HVPG detection was (5 617.2±2 079.4) yuan. 96.3% of the teams completed HVPG detection with balloon method, and most of the teams used thrombectomy balloon catheter (80.3%).Conclusion:Through this investigation, the status of domestic clinical application of HVPG has been clarified, and it has been confirmed that many domestic medical institutions have mastered this technology, but it still needs to continue to promote and popularize HVPG technology in the future.
		                        		
		                        		
		                        		
		                        	
6.Efficient cascade biosynthesis of (S)-2-hydroxybutyric acid.
Lingzhi TIAN ; Junping ZHOU ; Taowei YANG ; Xian ZHANG ; Minglong SHAO ; Meijuan XU ; Zhiming RAO
Chinese Journal of Biotechnology 2021;37(12):4231-4242
		                        		
		                        			
		                        			2-Hydroxybutyric acid (2-HBA) is an important intermediate for synthesizing biodegradable materials and various medicines. Chemically synthesized racemized 2-HBA requires deracemization to obtain optically pure enantiomers for industrial application. In this study, we designed a cascade biosynthesis system in Escherichia coli BL21 by coexpressing L-threonine deaminase (TD), NAD-dependent L-lactate dehydrogenase (LDH) and formate dehydrogenase (FDH) for production of optically pure (S)-2-HBA from bulk chemical L-threonine (L-Thr). To coordinate the production rate and the consumption rate of the intermediate 2-oxobutyric acid in the multi-enzyme cascade catalytic reactions, we explored promoter engineering to regulate the expression levels of TD and FDH, and developed a recombinant strain P21285FDH-T7V7827 with a tunable system to achieve a coordinated multi-enzyme expression. The recombinant strain P21285FDH-T7V7827 was able to efficiently produce (S)-2-HBA with the highest titer of 143 g/L and a molar yield of 97% achieved within 16 hours. This titer was approximately 1.83 times than that of the highest yield reported to date, showing great potential for industrial application. Our results indicated that constructing a multi-enzyme-coordinated expression system in a single cell significantly contributed to the biosynthesis of hydroxyl acids.
		                        		
		                        		
		                        		
		                        			Escherichia coli/genetics*
		                        			;
		                        		
		                        			Formate Dehydrogenases
		                        			;
		                        		
		                        			Hydroxybutyrates
		                        			;
		                        		
		                        			Threonine Dehydratase
		                        			
		                        		
		                        	
7.Correlation of neurocognitive impairment and metabolic changes of thalamus in patients with chronic liver cirrhosis
Junping PENG ; Guihua JIANG ; Xiaofei LYU ; Junzhang TIAN ; Huanhuan SU ; Chulan LIN ; Mingwu LOU
Chinese Journal of Medical Imaging Technology 2018;34(6):822-825
		                        		
		                        			
		                        			Objective To analyze the relationship of neurocognitive impairments and 1 H MRS changes of the thalamus in patients with chronic hepatitis B virus related cirrhosis (HBV-RC).Methods Totally 28 patients with HBV-RC (cirrhosis group) and 28 well-matched healthy subjects (control group) were enrolled.All subjects underwent number connection test A (NCT-A) and the digit symbol test (DST) before MRS scanning.The ratios of peak area to each metabolite,including N-acetylaminosuccinic acid (NAA),choline (Cho),glutamine and glutamate (Glx),myoinositol (mI) and creatine (Cr) were calculated,respectively.Results Compared with control group,patients in cirrhosis group showed lower Cho/Cr and mI/Cr,higher Glx/Cr,prolonged NCT-A time and decreased DST scores (all P<0.001).NCT-A completion time was negatively correlated with Cho/Cr and mI/Cr (r=-0.477,P =0.001;r=-0.695,P<0.001) and positively correlated with Glx/Cr (r=0.665,P<0.001).DST scores were positively correlated with Cho/Cr and mI/Cr (r =0.478,P =0.001;r=0.632,P<0.001),and negatively correlated with Glx/Cr (r=-0.572,P<0.001).Conclusion The neurocognitive impairments may be related to metabolic changes of the thalamus in patients with HBV RC.
		                        		
		                        		
		                        		
		                        	
8.Carotid plaque characteristics detected with 3.0T high resolution nuclear magnetic resonance imaging in patients with coronary artery disease.
Changpeng SONG ; Dezhao WANG ; Hongyu HU ; Qiang FU ; Wei CHEN ; Qian WANG ; Caixia GUO ; Junping TIAN ; Li MA ; Xiaowei XU ; Binbin SUI ; He JIN ; Buxing CHEN
Chinese Journal of Cardiology 2016;44(1):38-42
OBJECTIVETo assess the value of detecting the compositional features of carotid atherosclerotic plaques by 3.0T high resolution magnetic resonance imaging (MRI) in patients with coronary artery disease (CAD).
METHODSConsecutive 104 patients with coronary atherosclerosis confirmed by coronary angiography were prospectively recruited from January 2013 to January 2015 in Tiantan hospital. All patients were imaged with 3.0T high resolution MRI system. After exclusion patients with poor image quality, 97 patients were divided into 3 groups according to the degree of coronary artery stenosis: coronary atherosclerosis group (coronary stenosis between 1%-49%, n=16); single-vessel lesion group (single vessel lesion with stenosis between 50%-100%, n=48); multi-vessel lesion group (two or three vessel lesions with stenosis between 50%-100% or left main stem disease, n=33). The prevalence of total carotid plaque, calcified plaque, lipid-rich necrotic core, intra-plaque hemorrhage, plaque ulcer and rupture were compared among 3 groups.
RESULTSThe prevalence of total carotid plaque (81.3%(13/16), 72.9%(35/48), and 93.9%(31/33)) and calcified plaque (50.0%(8/16), 35.4%(17/48), and 42.4%(14/33)) were similar among the 3 groups (both P>0.05). The prevalence of carotid lipid-rich necrotic core in coronary atherosclerosis group was significantly lower than in single-vessel lesion group (18.8%(3/16) vs. 64.6%(31/48), P<0.01) and multi-vessel lesion group(18.8%(3/16) vs. 69.7%(23/33), P<0.01), but there was no significant difference between single-vessel lesion group and multi-vessel lesion group(P>0.05). Intra-plaque hemorrhage was detected in 2 patients of multi-vessel lesion group. There was no plaque ulcer or rupture in this cohort.
CONCLUSIONCarotid plaque features are associated with the severity of coronary atherosclerosis in CAD patients.
Coronary Artery Disease ; Hemorrhage ; Humans ; Magnetic Resonance Imaging ; Necrosis ; Plaque, Atherosclerotic ; Prevalence ; Prospective Studies
9.Corelation research between self-care ability and fatigue and loneliness in peritoneal dialysis patients
Xing TIAN ; Zhengyan LI ; Jing LUO ; Xiaoping LOU ; Jinhong MIAO ; Junping WANG ; Jing XIAO ; Zhanzheng ZHAO
Chinese Journal of Modern Nursing 2016;22(35):5080-5082,5083
		                        		
		                        			
		                        			Objective To explore self-care abilities and current status of fatigue and loneliness in peritoneal dialysis patients, and to determine the correlation between their self-care and fatigue & loneliness. Methods Totals of 237 cases with peritoneal dialysis followed up by Nephrology Department in the First Affiliated Hospital of Zhengzhou University were selected and surveyed by General patient information questionnaire, Exercise of Self-Care Agency Scale ( ESCA) , Multidimensional Fatigue Inventory-20 ( MFI-20) , and UCLA Loneliness Scale ( Chinese version ) . Results Scores of self-care ability in peritoneal dialysis patients were ( 92. 18 ± 15. 23) points, in the level above the average. Scores of fatigue in peritoneal dialysis patients were (61.24±11.72) points, and of loneliness (46.28±5.34), both higher than norm (P<0.01). Self-care ability of peritoneal dialysis patients showed a negative correlation with level of fatigue and loneliness ( P<0. 01) . It was revealed in multiple stepwise regression analysis that influencing factors of self-care abilities in peritoneal dialysis patients included comprehensive fatigue, less activity, physical fatigue and loneliness. Conclusions When making nursing measures for peritoneal dialysis patients, their fatigue and loneliness should be assessed. Targeting measures should be intervened to eliminate their fatigue and loneliness, so as to improve their self-care ability and quality of life.
		                        		
		                        		
		                        		
		                        	
10.Exploration on Medication Regularity of Epidemic Encephalitis B with Text Mining Technique
Jingping TIAN ; Aiping LV ; Guang ZHENG ; Jing ZHAO ; Feng CAI ; Hongtao GUO ; Junping ZHAN ; Chi ZHANG ; Miao JIANG ; Cheng LV
Chinese Journal of Information on Traditional Chinese Medicine 2013;(7):21-23,48
		                        		
		                        			
		                        			Objective To explore the clinical regularity of drugs on epidemic encephalitis B with text mining technique. Methods The data set on epidemic encephalitis B was downloaded from CBM database. The regularities of Chinese herbal medicine, Chinese patent medicine (CPM), western medicine and the combination of CPM and western medicine on epidemic encephalitis B were mined by data slicing algorithm. The results are showed visually with Cytoscape 2.8 software. Results The main function of herbal pieces was focused on clearing heat and removing toxicity. The herbal pieces such as Rehmanniae Radix Isatidis Raxis, Isatids Folium, Paeoniae Radis rubra and Scutellariae Radix were most often used. Angong Niuhuang Wan and Qingkailing Injection were usually used as CPM. For western medicine, antiviral drugs such as interferon and ribavirin were often used, and they were often used together with brain cells nutrition medicine, hormone, immunopotentiator and so on, and they were also frequently used together with CPM such as Angong Niuhuang Wan and Qingkailing Injection. Conclusion Text mining approach provides an important method in exploring the medication regularity for diseas, and provide refenrence for clinical use.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail