1.Diagnostic value of ACR TI-RADS combined with three-dimensional shear wave elastography in ACR TI-RADS 4 and 5 thyroid nodules.
Lijun HAO ; Peiqing LIU ; Changwei DING ; Jing LI ; Yingchun ZHANG
Chinese Medical Journal 2023;136(10):1225-1230
BACKGROUND:
Three-dimensional shear wave elastography (3D-SWE) is a promising method in distinguishing benign and malignant thyroid nodules. By combining with conventional method, it may further improve the diagnostic value. The study aimed to assess the diagnostic value of American College of Radiology (ACR) thyroid imaging reporting and data system (TI-RADS) combined with 3D-SWE in ACR TI-RADS 4 and 5 thyroid nodules.
METHODS:
All nodules were examined by conventional ultrasonography, ACR TI-RADS classification, and 3D-SWE examination. Conventional ultrasonography was used to observe the location, size, shape, margin, echogenicity, taller-than-wide sign, microcalcification, and blood flow of thyroid nodules, and then ACR TI-RADS classification was performed. The Young's modulus values (3D-C-Emax, 3D-C-Emean, and elastography standard deviation [3D-C-Esd]) were measured on the reconstructed coronal plane images. According to the receiver operating characteristic (ROC) curve, the best diagnostic efficiency among 3D-C-Emax, 3D-C-Emean, and 3D-C-Esd was selected and the cut-off threshold was calculated. According to the surgical pathology, they were divided into benign group and malignant group. And appropriate statistical methods such as t -test and Mann-Whitney U test were used to compare the difference between the two groups. On this basis, 3D-SWE combined with conventional ACR TI-RADS was reclassified as combined ACR TI-RADS to determine benign or malignant thyroid nodules.
RESULTS:
Of the 112 thyroid nodules, 62 were malignant and 50 were benign. The optimal cut-off value of three-dimensional maximum Young's modulus in coronal plane (3D-C-Emax) was 51.5 kPa and the area under the curve (AUC) was 0.798. The AUC, sensitivity, specificity, and accuracy of conventional ACR TI-RADS were 0.828, 83.9%, 66.0%, and 75.9%, respectively. The AUC, sensitivity, specificity, and accuracy of combined ACR TI-RADS were 0.845, 90.3%, 66.0%, and 79.5%, respectively. The difference between the two AUC values was statistically significant.
CONCLUSIONS
Combined ACR TI-RADS has higher diagnostic efficiency than conventional ACR TI-RADS. The sensitivity and accuracy of combined ACR TI-RADS showed significant improvements. It can be used as an effective method in the diagnosis of thyroid nodules.
Humans
;
Thyroid Nodule/pathology*
;
Elasticity Imaging Techniques/methods*
;
Retrospective Studies
;
Ultrasonography/methods*
2.Diagnostic Value of American Thyroid Association Guidelines,American College of Radiology Thyroid Imaging Reporting and Data System,and Chinese Thyroid Imaging Reporting and Data System Alone and Combined With BRAFV600E Mutation in Atypia of Undetermined Significance/Follicular Lesion of Undetermined Significance.
Yu LIN ; Yu-Kun LUO ; Jie LI ; Xiu-Yun REN ; Hong-Wei WANG
Acta Academiae Medicinae Sinicae 2023;45(6):921-928
Objective To explore the diagnostic efficacy of American Thyroid Association(ATA)guidelines,American College of Radiology Thyroid Imaging Report and Data System(ACR-TIRADS),and Chinese Thyroid Imaging Reporting and Data System(C-TIRADS)alone and combined with BRAFV600E mutation in atypia of undetermined significance/follicular lesion of undetermined significance(AUS/FLUS).Methods A total of 138 patients who underwent ultrasound-guided fine needle aspiration(FNA)in the Chinese PLA General Hospital from January 2020 to May 2023 were selected.The clinicopathological and ultrasound characteristics were retrospectively analyzed for each nodule.Each nodule underwent preoperative BRAFV600E mutation testing and was diagnosed according to the ATA guidelines,ACR-TIRADS,and C-TIRADS.The diagnostic efficacy of ATA guidelines,ACR-TIRADS,and C-TIRADS alone and combined with BRAFV600E mutation was assessed based on the results of histopathological diagnosis.Results The 138 AUS/FLUS thyroid nodules included 45(32.6%)benign ones and 93(67.4%)malignant ones.The patient age(t=1.444,P=0.151),gender(χ2=0.259,P=0.611),and location of nodules(χ2=2.055,P=0.358)had no statistical significance for the differentiation between benign and malignant nodules,while nodule size(Z=2.500,P=0.012),echo(χ2=14.693,P<0.001),composition(χ2=17.075,P<0.001),aspect ratio ≥1(χ2=9.477,P=0.002),and microcalcification(χ2=6.892,P=0.009)were of significance for the differentiation.When applied alone,BRAFV600E mutation showed high specificity(95.56%)and positive predictive value(95.65%).Among the three ultrasound grading systems,ACR-TIRADS had the highest sensitivity(χ2=37.923,P<0.001;χ2=40.462,P<0.001)and accuracy(χ2=81.595,P<0.001;χ2=76.912,P<0.001),while C-TIRADS had the highest specificity(χ2=11.746,P<0.001;χ2=21.235,P<0.001).However,the three systems showed no statistically significant difference in the diagnostic efficiency when applied alone(Z=1.177,P=0.239;Z=0.213,P=0.831;Z=1.016,P=0.310).The combination of BRAFV600E mutation with ACR-TIRADS or C-TIRADS improved the diagnostic efficacy of BRAFV600E mutation in distinguishing the benign and malignant AUS/FLUS nodules(Z=2.107,P=0.035;Z=2.752,P=0.006).The combination of ATA guidelines with BRAFV600E mutation increased the diagnostic accuracy of BRAFV600E mutation(χ2=20.679,P<0.001),while it had no statistically significant difference in distinguishing the benign and malignant AUS/FLUS nodules(Z=1.321,P=0.186).The combination of ATA guidelines,ACR-TIRADS,or C-TIRADS with BRAFV600E mutation improved the diagnostic efficacy of ultrasound grading systems for AUS/FLUS nodules(Z=2.770,P=0.006;Z=2.770,P=0.006;Z=2.890,P=0.004).Specifically,ACR-TIRADS combined with BRAFV600E mutation showed the highest sensitivity(χ2=4.712,P=0.030;χ2=4.712,P=0.030),while C-TIRADS combined with BRAFV600E mutation showed the highest accuracy(χ2=77.627,P<0.001;χ2=85.827,P<0.001).However,there were no statistically significant differences in diagnostic performance between the combinations(Z=1.276,P=0.202;Z=0.808,P=0.419;Z=1.615,P=0.106).Conclusion ATA guidelines,ACR-TIRADS,and C-TIRADS combined with BRAFV600E mutation can improve the diagnostic efficacy of BRAFV600E mutation or ultrasound grading system alone in AUS/FLUS nodules,which can facilitate the further management and treatment of such patients.
Humans
;
United States
;
Infant
;
Thyroid Neoplasms/genetics*
;
Proto-Oncogene Proteins B-raf/genetics*
;
Adenocarcinoma, Follicular/pathology*
;
Retrospective Studies
;
Data Systems
;
Thyroid Nodule/genetics*
;
Ultrasonography/methods*
;
Mutation
;
China
;
Radiology
3.Influencing Factors of Bethesda Ⅲ Results in Fine-Needle Aspiration Biopsy of Thyroid Nodules.
Jian LIU ; Shang-Hong XIE ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(6):929-933
Objective To investigate the influencing factors of Bethesda Ⅲ results in fine-needle aspiration biopsy of thyroid nodules.Methods A total of 300 thyroid nodules with cytological diagnosis results were analyzed retrospectively,including 100 Bethesda Ⅲ nodules and 50 nodules of Bethesda Ⅱ,Ⅳ,Ⅴ,and Ⅵ categories,respectively.Univariate analysis and Logistic regression analysis were performed on the clinical data of patients and the ultrasound signs of thyroid nodules to clarify the factors influencing the diagnosis of Bethesda Ⅲ nodules.Results Univariate analysis showed that Bethesda Ⅲ nodules were mostly adjacent to the capsule(P<0.001),with no blood flow in the color Doppler assessment(P=0.011)and lack of blood supply(P=0.033)and maximum diameter ≤0.9 cm(P=0.038)as revealed by the contrast-enhanced ultrasound.Logistic regression showed that the position close to the capsule(OR=5.110,95%CI=2.153-12.130,P<0.001)and color Doppler without blood flow signal(OR=3.015,95%CI=1.094-8.311,P=0.033)were independent risk factors for the diagnosis of Bethesda Ⅲ nodules.Conclusions The puncture difficulty caused by the dangerous position of thyroid nodules close to the capsule and the aspiration difficulty caused by the absence of blood flow signal in color Doppler are the main factors influencing the diagnosis of Bethesda Ⅲ nodules.Therefore,corresponding avoidance measures should be taken during the aspiration process to reduce the diagnosis results of Bethesda Ⅲ nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Thyroid Neoplasms/diagnosis*
;
Biopsy, Fine-Needle/methods*
;
Retrospective Studies
;
Ultrasonography/methods*
4.Evaluation of Extrathyroidal Extension of Papillary Thyroid Microcarcinoma With Three-Dimensional Tomographic Ultrasound Imaging.
Ru-Yu LIU ; Yu-Xin JIANG ; Rui-Na ZHAO ; Xing-Jian LAI ; Chuan-Ying-Zi LU ; Lu-Ying GAO ; Ying WANG ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):361-365
Objective To evaluate extrathyroidal extension (ETE) in papillary thyroid microcarcinoma (PTMC) with three-dimensional tomographic ultrasound imaging (3D-TUI). Methods A total of 97 thyroid nodules of 79 patients with PTMC treated in PUMC Hospital from February 2016 to January 2018 were included in this study.Two ultrasound experts performed independent blinded assessment of the relationship between thyroid nodules and thyroid capsule by two-dimensional ultrasound (2D-US) and 3D-TUI.The results of 2D-US and 3D-TUI in evaluating ETE were compared with intraoperative findings and postoperative histological and pathological results. Results Among the 97 nodules,54 (55.7%) nodules had ETE.The diagnostic sensitivity (68.5% vs.37.0%;χ2=10.737,P=0.002),accuracy (74.5% vs.56.7%;χ2=6.686,P=0.015),and area under the receiver operating characteristic curve[0.761 (95%CI=0.677-0.845) vs.0.592 (95%CI=0.504-0.680);Z=3.500,P<0.001] of 3D-TUI were higher than those of 2D-US.However,3D-TUI and 2D-US showed no significant difference in the specificity (84.1% vs.81.4%;χ2=0.081,P=0.776),negative predictive value (67.9% vs.50.7%;χ2=3.645,P=0.066),or positive predictive value (84.1% vs.71.4%;χ2=1.663,P=0.240). Conclusion Compared with 2D-US,3D-TUI demonstrates increased diagnostic efficiency for ETE of PTMC.
Humans
;
Thyroid Nodule
;
Thyroid Neoplasms/diagnosis*
;
Carcinoma, Papillary/pathology*
;
Ultrasonography/methods*
;
Retrospective Studies
5.Influencing Factors and Prediction Model of Performance of Needle Visualization in Fine Needle Aspiration of Thyroid Nodules.
Liang-Kai WANG ; Jia-Jia TANG ; Wen-Quan NIU ; Xin-Ying JIA ; Xue-Hua XI ; Jiao-Jiao MA ; Hui-Lin LI ; Zhe SUN ; Xin-Yi LIU ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):366-373
Objective To investigate the influencing factors and establish a model predicting the performance of needle visualization in fine-needle aspiration (FNA) of thyroid nodules. Methods This study prospectively included 175 patients who underwent FNA of thyroid nodules in the Department of Ultrasound in China-Japan Friendship Hospital and compared the display of the needle tips in the examination of 199 thyroid nodules before and after the application of needle visualization.We recorded the location,the positional relationship with thyroid capsule,ultrasonic characteristics,and the distribution of the soft tissue strip structure at the puncture site of the nodules with unclear needle tips display before using needle visualization.Furthermore,according to the thyroid imaging reporting and data system proposed by the American College of Radiology,we graded the risk of the nodules.Lasso-Logistic regression was employed to screen out the factors influencing the performance of needle visualization and establish a nomogram for prediction. Results The needle tips were not clearly displayed in the examination of 135 (67.8%) and 53 (26.6%) nodules before and after the application of needle visualization,respectively,which showed a significant difference (P<0.001).Based on the positional relationship between the nodule and capsule,anteroposterior/transverse diameter (A/T) ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site,a nomogram was established to predict the probability of unclear display of the needle tips after application of needle visualization.The C-index of the prediction model was 0.75 (95%CI=0.67-0.84) and the area under the receiver operating characteristic curve was 0.72.The calibration curve confirmed the appreciable reliability of the prediction model,with the C-index of 0.70 in internal validation. Conclusions Needle visualization can improve the display of the needle tip in ultrasound-guided FNA of thyroid nodules.The nomogram established based on ultrasound features such as the positional relationship between the nodule and capsule,A/T ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site can predict whether needle visualization is suitable for the examination of nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Biopsy, Fine-Needle/methods*
;
Reproducibility of Results
;
Ultrasonography
;
Retrospective Studies
;
Thyroid Neoplasms
6.Application of Micro-flow Imaging in the Differentiation of Benign and Malignant Thyroid Nodules.
Qing SONG ; Lin-Li KANG ; Yu LAN ; Lin YAN ; Wen LI ; Ling REN ; Yu-Kun LUO
Acta Academiae Medicinae Sinicae 2022;44(1):40-44
Objective To evaluate the performance of micro-flow imaging(MFI)in the differential diagnosis of benign and malignant thyroid nodules. Methods Totally 50 patients with thyroid nodules examined by conventional ultrasound,MFI,and contrast-enhanced ultrasound and confirmed by histological or cytological pathology in the First Medical Center of Chinese PLA General Hospital from May to December in 2020 were enrolled in the study.The clinical data and ultrasound images were retrospectively analyzed.A binary logistic regression model was established to evaluate the performance of the model in predicting benign and malignant thyroid nodules. Results Logistic regression showed that composition and "S-W-C" sign were independent risk factors for predicting malignant thyroid nodule.The sensitivity,specificity,and Youden index of the logistic regression model were 73.33%,80.00%,and 0.53,respectively,and the area under receiver operating characteristic curve was 0.799(95%CI=0.662-0.899). Conclusion MFI facilitates the differential diagnosis of benign and malignant thyroid nodules and has the potential to be applied in the future.
Diagnosis, Differential
;
Humans
;
ROC Curve
;
Retrospective Studies
;
Thyroid Nodule/diagnostic imaging*
;
Ultrasonography/methods*
8.Active surveillance for thyroid micro-malignant nodules.
Ying Cheng HUANG ; Ze Hao HUANG ; Hui Zhu CAI ; Xi Wei ZHANG ; Dan Gui YAN ; Chang Ming AN ; Zong Min ZHANG ; Li Juan NIU ; Zheng Jiang LI
Chinese Journal of Oncology 2022;44(11):1214-1220
Objective: To evaluate the effect of ultrasound diagnosis of thyroid micro-malignant nodules and accumulate practical experience for the management of active surveillance for them, so as to avoid overtreatment. Methods: A total of 949 patients who were diagnosed with thyroid malignant nodules using ultrasonography, with the nodules being less than 1 cm in size and without regional lymph node metastasis or distant metastasis, were included. They were treated by the same surgeon of the Department of Head and Neck Surgery, Cancer Hospital, Chinese Academy of Medical Sciences from February 2014 to December 2020. 112 patients chose immediate surgery. The rest patients were asked to accept ultrasound examination every 6 months to 1 year. Follow-up endpoints: tumor size growth of 3 mm, tumor volume increase greater than 50%, lymph node metastasis or distant metastasis. Results: The median follow-up time was 19 months. 713 patients underwent surveillance for more than 6 months. Of the 713 patients, 570 (79.9%) were women, with mean age at 43.5 years old. Tumor progression was observed in 47 (6.6%) patients with a cumulative incidence of 2.7% (1 year), 7.2% (2 years) and 9.5% (3 years). In multivariate analysis, patient age [HR=0.508, 95%CI: 0.275-0.939, P=0.031], lesion number [HR=2.945, 95%CI: 1.593-5.444, P=0.001] and tumor size [HR=2.245, 95%CI: 1.202-4.192, P=0.011] at the beginning of observation were independent risk factors for tumor progression in patients with minimal thyroid malignant nodules during follow-up. During a median (range) active surveillance of 19 (6-80) months, 74 patients chose surgery during the surveillance. Among the 186 patients who underwent surgery, only 3 patients were diagnosed with fibrotic nodules in pathology, while the rest were papillary thyroid carcinoma. The ultrasound accuracy reached 98.4%(183/186). Conclusions: Ultrasonography is an effective method of diagnosing malignant thyroid nodules. Thyroid micro-malignant nodules progress slowly. As a result, it is safe to observe them instead of taking immediate surgery. Patient age, lesion number and tumor size at the beginning of observation are independent risk factors for the tumor progression of malignant nodules.
Humans
;
Female
;
Adult
;
Male
;
Thyroid Nodule/surgery*
;
Carcinoma, Papillary/surgery*
;
Lymphatic Metastasis
;
Thyroid Neoplasms/surgery*
;
Thyroidectomy/methods*
;
Watchful Waiting
;
Ultrasonography
;
Retrospective Studies
9.Ultrasonographic assessment and differentiation of spontaneous degenerating cystic thyroid nodules and papillary thyroid carcinomas.
Xing Zhi HUANG ; Xiang MIN ; Ai Yun ZHOU ; Wan ZHU ; Xin Chun YUAN ; Qi QI ; Fan XIAO ; Pan XU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2021;56(1):75-78
Objective: To analyze the features of degenerating cystic thyroid nodules (DCTN) on conventional ultrasound and contrast-enhanced ultrasound (CEUS), and to explore the differentiation between DCTN and papillary thyroid carcinomas (PTC). Methods: A total of 46 DCTN (39 cases, including 12 males and 27 females, with an age range of 25 to 76 years) and 36 PTC (32 cases, including 8 males and 24 females, with an age range of 23 to 68 years) diagnosed via fine- needle aspiration (FNA) or surgery from February 2019 to January 2020 in the First Affiliated Hospital of Nanchang University were enrolled. The size, shape, margin, echogenicity, presence of shadowing, calcification and vascularity of DCTN and PTC were retrospectively evaluated, and 28 DCTN and 30 PTC underwent CEUS were separately analyzed and compared.The t test, χ² test or Fisher's exact test were implemented to compare the features of ultrasound among the two groups. The binary Logistic regression test was performed to determine whether the feature whose difference was statistically significant was an independent predictive risk factor. Results: A univariate analysis indicated that DCTN more frequently showed wider-than-tall shapes, marked hypoechogenicity, well-defined margin and no or dot-lined enhancement (wider-than-tall shapes: 36 vs. 17, χ2=8.511; well-defined margin: 30 vs. 15, χ2=4.523; marked hypoechogenicity: 27 vs. 9, χ2=9.310; no or dot-lined enhancement: 24 vs. 3, χ2=33.369; all P<0.05). A multivariate analysis demonstrated that wider-than-tall shapes, well-defined margin and marked hypoechogenicity were independent predictors for DCTN (OR values were 5.204, 3.134 and 5.042, P values were 0.003, 0.031, and 0.003, respectively). Among 28 DCTN, 15 showed a decrease in mean maximum diameter (24.3±11.4 mm) with a mean time span of (18.6±10.5) months between the presence and absence of suspicious ultrasound features. Conclusions: Compared with PTC, DCTN shows the ultrasound characteristics of wider-than-tall shapes, well-defined margin, marked hypoechogenicity and no or dot-lined enhancement pattern. Ultrasound follow-up can help to identify spontaneous DCTN.
Adult
;
Aged
;
Carcinoma, Papillary/diagnostic imaging*
;
Female
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
;
Thyroid Cancer, Papillary/diagnostic imaging*
;
Thyroid Neoplasms/diagnostic imaging*
;
Thyroid Nodule/diagnostic imaging*
;
Ultrasonography
10.High frequency ultrasound combined with ultrasound-guided core needle biopsy for the diagnosis of primary thyroid lymphoma.
Li Long XU ; Shi Yan LI ; Jiang ZHU ; Jiang Hong LYU ; Ming Xuan ZHANG ; Li GAO ; Lei XIE ; Zhi Nong JIANG ; Guo Xiang FU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2021;56(8):858-862
Objective: To investigate the sonographic features of primary thyroid lymphoma (PTL) and to evaluate the clinical significance of ultrasound-guided core needle biopsy (US-CNB) in PTL. Methods: A total of 24 patients with suspected PTL in Sir Run Run Shaw Hospital from January 2013 to June 2018 were analyzed retrospectively. All cases were confirmed by pathology, of them 23 patients received US-CNB and 1 patient chose operation without US-CNB, including 5 males and 19 females, aged from 39 to 75 years old. The effectiveness and safety of 23 patients with US-CNB were evaluated, and the sonographic features of 20 patients with PTL diagnosed by pathology were analyzed. Descriptive statistical methods were used in the study. Results: In the 23 patients with suspected PTL underwent US-CNB, 18 patients were diagnosed as PTL, 4 patients were respectively diagnosed as subacute thyroiditis, anaplastic carcinoma, Hashimoto's thyroiditis, and fibro thyroiditis, and the another patient was hard to diagnose by US-CNB and then was diagnosed as PTL by surgical biopsy. The success rate of US-CNB for diagnosis of PTL was 18/19, and no severe complications occurred in the patients with US-CNB. The other case was diagnosed as PTL by surgical biopsy without US-CNB. Sonographic features of 20 cases with PTL (18 cases diagnosed by US-CNB and 2 cases by surgery or surgery biopsy) were as follows: (1) Most nodules had irregular shapes and unsmooth margins; (2) Hypoechoic or markedly hypoechoic nodules with honeycombed or cord structures were observed in most cases; (3) Calcification was rare; (4) Multiple lesions were common; (5) Abundant intralesional vascularization was commonly observed; (6) Most cases had intensification of posterior acoustic enhancement; (7) Thyroid gland enlargement or with irregular shape; and (8) PTL often accompanied with lymph nodes enlargement in lateral neck or central region. Conclusion: PTL has certain sonographic features, with assistance of US-CNB, more accurate diagnosis of PTL can be obtained.
Adult
;
Aged
;
Biopsy, Large-Core Needle
;
Female
;
Humans
;
Image-Guided Biopsy
;
Lymphoma/diagnostic imaging*
;
Male
;
Middle Aged
;
Retrospective Studies
;
Thyroid Gland
;
Thyroid Neoplasms/diagnostic imaging*
;
Thyroid Nodule
;
Ultrasonography, Interventional

Result Analysis
Print
Save
E-mail