1.High frequency ultrasound combined with ultrasound-guided core needle biopsy for the diagnosis of primary thyroid lymphoma.
Li Long XU ; Shi Yan LI ; Jiang ZHU ; Jiang Hong LYU ; Ming Xuan ZHANG ; Li GAO ; Lei XIE ; Zhi Nong JIANG ; Guo Xiang FU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2021;56(8):858-862
Objective: To investigate the sonographic features of primary thyroid lymphoma (PTL) and to evaluate the clinical significance of ultrasound-guided core needle biopsy (US-CNB) in PTL. Methods: A total of 24 patients with suspected PTL in Sir Run Run Shaw Hospital from January 2013 to June 2018 were analyzed retrospectively. All cases were confirmed by pathology, of them 23 patients received US-CNB and 1 patient chose operation without US-CNB, including 5 males and 19 females, aged from 39 to 75 years old. The effectiveness and safety of 23 patients with US-CNB were evaluated, and the sonographic features of 20 patients with PTL diagnosed by pathology were analyzed. Descriptive statistical methods were used in the study. Results: In the 23 patients with suspected PTL underwent US-CNB, 18 patients were diagnosed as PTL, 4 patients were respectively diagnosed as subacute thyroiditis, anaplastic carcinoma, Hashimoto's thyroiditis, and fibro thyroiditis, and the another patient was hard to diagnose by US-CNB and then was diagnosed as PTL by surgical biopsy. The success rate of US-CNB for diagnosis of PTL was 18/19, and no severe complications occurred in the patients with US-CNB. The other case was diagnosed as PTL by surgical biopsy without US-CNB. Sonographic features of 20 cases with PTL (18 cases diagnosed by US-CNB and 2 cases by surgery or surgery biopsy) were as follows: (1) Most nodules had irregular shapes and unsmooth margins; (2) Hypoechoic or markedly hypoechoic nodules with honeycombed or cord structures were observed in most cases; (3) Calcification was rare; (4) Multiple lesions were common; (5) Abundant intralesional vascularization was commonly observed; (6) Most cases had intensification of posterior acoustic enhancement; (7) Thyroid gland enlargement or with irregular shape; and (8) PTL often accompanied with lymph nodes enlargement in lateral neck or central region. Conclusion: PTL has certain sonographic features, with assistance of US-CNB, more accurate diagnosis of PTL can be obtained.
Adult
;
Aged
;
Biopsy, Large-Core Needle
;
Female
;
Humans
;
Image-Guided Biopsy
;
Lymphoma/diagnostic imaging*
;
Male
;
Middle Aged
;
Retrospective Studies
;
Thyroid Gland
;
Thyroid Neoplasms/diagnostic imaging*
;
Thyroid Nodule
;
Ultrasonography, Interventional
2.Feasibility of Adjustable Electrodes for Radiofrequency Ablation of Benign Thyroid Nodules
Jiyeong LEE ; Jung Hee SHIN ; Soo Yeon HAHN ; Ko Woon PARK ; Ji Soo CHOI
Korean Journal of Radiology 2020;21(3):377-383
OBJECTIVE: The purpose of this study was to evaluate a novel radiofrequency ablation (RFA) application utilizing an adjustable electrode for treatment of benign thyroid nodules.MATERIALS AND METHODS: From April 2011 to December 2018, 21 patients underwent RFA treatment on 21 thyroid nodules, utilizing an 18-gauge internally cooled electrode equipped with a size adjustable active tip. The peripheral nodule portions were ablated with the moving-shot technique and a shorter active tip, and the nodule centers were ablated with the fixed technique and a longer active tip. We assessed parameters including characteristics of the treated nodules, use of variablesized active tips, volume reduction rate, therapeutic success rate, and post-procedural complications. The therapeutic success rate was defined as a > 50% volume reduction of the initial nodule volume at the 6- or 12-month follow-up.RESULTS: The treated thyroid nodules were large enough to cause symptoms (mean volume, 29.6 mL). Two types of active tips per session were used for all nodules. The mean volume reduction rate at the last follow-up was 68.3 ± 4.4% and our therapeutic success rate was 90.5%. Both symptoms and cosmetic scores decreased significantly. Minor complications in three patients were recorded during and after the procedure.CONCLUSION: This initial study demonstrated that an adjustable electrode for RFA of benign thyroid nodules effectively and safely resulted in volume reduction.
Catheter Ablation
;
Electrodes
;
Follow-Up Studies
;
Humans
;
Thyroid Gland
;
Thyroid Nodule
;
Ultrasonography
3.Computer-Aided Diagnosis System for the Evaluation of Thyroid Nodules on Ultrasonography: Prospective Non-Inferiority Study according to the Experience Level of Radiologists
Sae Rom CHUNG ; Jung Hwan BAEK ; Min Kyoung LEE ; Yura AHN ; Young Jun CHOI ; Tae Yon SUNG ; Dong Eun SONG ; Tae Yong KIM ; Jeong Hyun LEE
Korean Journal of Radiology 2020;21(3):369-376
OBJECTIVE: To determine whether a computer-aided diagnosis (CAD) system for the evaluation of thyroid nodules is non-inferior to radiologists with different levels of experience.MATERIALS AND METHODS: Patients with thyroid nodules with a decisive diagnosis of benign or malignant nodule were consecutively enrolled from November 2017 to September 2018. Three radiologists with different levels of experience (1 month, 4 years, and 7 years) in thyroid ultrasound (US) reviewed the thyroid US with and without using the CAD system. Statistical analyses included non-inferiority testing of the diagnostic accuracy for malignant thyroid nodules between the CAD system and the three radiologists with a non-inferiority margin of 10%, comparison of the diagnostic performance, and the added value of the CAD system to the radiologists.RESULTS: Altogether, 197 patients were included in the study cohort. The diagnostic accuracy of the CAD system (88.48%, 95% confidence interval [CI] = 82.65–92.53) was non-inferior to that of the radiologists with less experience (1 month and 4 year) of thyroid US (83.03%, 95% CI = 76.52–88.02; p < 0.001), whereas it was inferior to that of the experienced radiologist (7 years) (95.76%, 95% CI = 91.37–97.96; p = 0.138). The sensitivity and negative predictive value of the CAD system were significantly higher than those of the less-experienced radiologists were, whereas no significant difference was found with those of the experienced radiologist. A combination of US and the CAD system significantly improved sensitivity and negative predictive value, although the specificity and positive predictive value deteriorated for the less-experienced radiologists.CONCLUSION: The CAD system may offer support for decision-making in the diagnosis of malignant thyroid nodules for operators who have less experience with thyroid US.
Cohort Studies
;
Diagnosis
;
Humans
;
Prospective Studies
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
4.Ultrasonographic Demonstration of the Tissue Microvasculature in Children: Microvascular Ultrasonography Versus Conventional Color Doppler Ultrasonography
Joonghyun YOO ; Bo Kyung JE ; Ji Yung CHOO
Korean Journal of Radiology 2020;21(2):146-158
ultrasonography are its superiority in detection and visualization of the small blood vessels in tissues, providing radiologists with more information on the vascular structures. Therefore, it has shown particular value in the clinical fields. The aim of this study was to provide microvascular ultrasonographic images for the tissue microvasculature, including the brain, thyroid gland, kidney, urinary bladder, small bowel, ovary, testis, lymph node, and hemangiomas in children, focusing on the comparison with conventional color Doppler ultrasonographic images.]]>
Artifacts
;
Blood Vessels
;
Brain
;
Child
;
Female
;
Hemangioma
;
Humans
;
Kidney
;
Lymph Nodes
;
Microvessels
;
Ovary
;
Testis
;
Thyroid Gland
;
Ultrasonography
;
Ultrasonography, Doppler, Color
;
Urinary Bladder
5.Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
Younghee YIM ; Dong Gyu NA ; Eun Ju HA ; Jung Hwan BAEK ; Jin Yong SUNG ; Ji hoon KIM ; Won Jin MOON
Korean Journal of Radiology 2020;21(1):108-116
Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies.MATERIALS AND METHODS: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated.RESULTS: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1–100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8–83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7–19.8%, 0–40.9%, and 0.1–30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0–5.9%, 0–10.9%, and 0.1–8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0–33.8%), decreased with the simulated biopsy size criteria (0–8.7%).CONCLUSION: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.]]>
Biopsy
;
Classification
;
Dataset
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
6.Core-Needle Biopsy Does Not Show Superior Diagnostic Performance to Fine-Needle Aspiration for Diagnosing Thyroid Nodules
Ilah SHIN ; Eun Kyung KIM ; Hee Jung MOON ; Jung Hyun YOON ; Vivian Youngjean PARK ; Si Eun LEE ; Hye Sun LEE ; Jin Young KWAK
Yonsei Medical Journal 2020;61(2):161-168
thyroid nodules according to nodule size.MATERIALS AND METHODS: This retrospective study included 320 thyroid nodules from 320 patients who underwent both FNA and CNB at outside clinics and proceeded with surgery in our institution between July 2012 and May 2019. According to nodule size, the diagnostic performances of FNA and CNB were calculated using various combinations of test-negatives and test-positives defined by the Bethesda categories and were compared using the generalized estimated equation and the Delong method.RESULTS: There were 279 malignant nodules in 279 patients and 41 benign nodules in 41 patients. The diagnostic performance of FNA was mostly not different from CNB regardless of nodule size, except for negative predictive value, which was better for FNA than CNB when applying Criteria 1 and 2. When applying Criteria 3, the specificity and positive predictive value of FNA were superior to CNB regardless of size. When applying Criteria 4, diagnostic performance did not differ between FNA and CNB regardless of size. After applying Criteria 5, diagnostic performance did not differ between FNA and CNB in nodules ≥2 cm. However, in nodules ≥1 cm and all nodules, the sensitivity, accuracy, and negative predictive value of CNB were better than those of FNA.CONCLUSION: CNB did not show superior diagnostic performance to FNA for diagnosing thyroid nodules.]]>
Biopsy
;
Biopsy, Fine-Needle
;
Biopsy, Large-Core Needle
;
Humans
;
Methods
;
Retrospective Studies
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
7.Percutaneous laser ablation for benign and malignant thyroid diseases.
Giovanni MAURI ; Luca NICOSIA ; Paolo DELLA VIGNA ; Gianluca Maria VARANO ; Daniele MAIETTINI ; Guido BONOMO ; Gioacchino GIULIANO ; Franco ORSI ; Luigi SOLBIATI ; Elvio DE FIORI ; Enrico PAPINI ; Claudio Maurizio PACELLA ; Luca Maria SCONFIENZA
Ultrasonography 2019;38(1):25-36
Minimally invasive image-guided thermal ablation is becoming increasingly common as an alternative to surgery for the treatment of benign thyroid nodules. Among the various techniques for thermal ablation, laser ablation (LA) is the least invasive, using the smallest applicators available on the market and enabling extremely precise energy deposition. However, in some cases, multiple laser fibers must be used simultaneously for the treatment of large nodules. In this review, the LA technique is described, and its main clinical applications and results are discussed and illustrated.
Laser Therapy*
;
Thyroid Diseases*
;
Thyroid Gland*
;
Thyroid Nodule
;
Ultrasonography
8.(99m)Tc-Pertechnetate Scintigraphy Predicts Successful Postoperative Ablation in Differentiated Thyroid Carcinoma Patients Treated with Low Radioiodine Activities
Luca GIOVANELLA ; Gaetano PAONE ; Teresa RUBERTO ; Luca CERIANI ; Pierpaolo TRIMBOLI
Endocrinology and Metabolism 2019;34(1):63-69
BACKGROUND: Postoperative routine radioiodine (RAI) treatment is currently debated for patients with low-risk differentiated thyroid carcinoma (DTC) patients. If performed, a low 131I activity (i.e., 1 to 2 GBq) is recommended with the aim to ablate thyroid remnant and facilitate subsequent follow-up by thyroglobulin measurement. The purpose of this study was to evaluate the relationship between postsurgical technetium-99m (99mTc)-pertechnetate scintigraphy and the rate of successful remnant ablation after low activity radioiodine ablation in patients with DTC. METHODS: Enrolled were 193 patients with low risk DTC who underwent total thyroidectomy and RAI ablation with a fixed 1.1 GBq activity of 131I. 99mTc-pertechnetate scans were done and thyrotropin stimulated thyroglobulin (sTg) levels measured just before ablation. Ablation effectiveness was assessed 6 to 12 months later by sTg measurement, neck ultrasound and diagnostic whole body scan. RESULTS: A negative 99mTc-perthecnetate scans was the best predictor of successful ablation (P<0.001) followed by preablative sTg levels <0.8 ng/mL (P=0.008) and 99mTc-pertechnetate uptake rate values <0.9% (P=0.065). Neither sex nor age of the patient at the time of ablation or tumor histology and size showed a significant association with the rate of successful ablation. CONCLUSION: The 99mTc-pertechnetate scintigraphy is a simple and feasible tool to predict effectiveness of low activity 131I thyroid to ablate thyroid remnants in patients with DTC.
Follow-Up Studies
;
Humans
;
Neck
;
Radionuclide Imaging
;
Sodium Pertechnetate Tc 99m
;
Thyroglobulin
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroidectomy
;
Thyrotropin
;
Ultrasonography
;
Whole Body Imaging
9.Technical Report: A Cost-Effective, Easily Available Tofu Model for Training Residents in Ultrasound-Guided Fine Needle Thyroid Nodule Targeting Punctures.
Yun Fei ZHANG ; Hong LI ; Xue Mei WANG
Korean Journal of Radiology 2019;20(1):166-170
OBJECTIVE: To establish a cost-effective and easily available phantom for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures. MATERIALS AND METHODS: Tofu, drinking straws filled with coupling gel, a urine tube, and 21-gauge needles were used to generate a phantom thyroid with nodules for training. Twelve radiology residents were involved in the study. The puncture success rates were recorded and compared before and after phantom training using the Wilcoxon signed-rank test. RESULTS: On ultrasonography, tofu mimicked the texture of the thyroid. Drinking straws filled with coupling gel mimicked vessels. The urine tube filled with air mimicked the trachea, and 21-gauge needles mimicked small nodules in the transverse section. The entire phantom was similar to the structure of the thyroid and surrounding tissues. The puncture success rates of radiology residents were significantly increased from 34.4 ± 14.2% to 66.7 ± 19.5% after training (p = 0.003). The phantom was constructed in approximately 10 minutes and materials cost less than CNY 10 (approximately $ 1.5) at a local store. CONCLUSION: The tofu model was cost-effective, easily attainable, and effective for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures in vitro.
Drinking
;
In Vitro Techniques
;
Needles*
;
Punctures*
;
Soy Foods*
;
Thyroid Gland*
;
Thyroid Nodule*
;
Trachea
;
Ultrasonography
10.The Role of Core Needle Biopsy for the Evaluation of Thyroid Nodules with Suspicious Ultrasound Features.
Sae Rom CHUNG ; Jung Hwan BAEK ; Young Jun CHOI ; Tae Yon SUNG ; Dong Eun SONG ; Tae Yong KIM ; Jeong Hyun LEE
Korean Journal of Radiology 2019;20(1):158-165
OBJECTIVE: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodules has not been fully evaluated. This prospective study aimed to determine the potential of CNB to assess thyroid nodules with suspicious ultrasound (US) features. MATERIALS AND METHODS: Patients undergoing CNB for thyroid nodules with suspicious features on US were enrolled between May and August 2016. Diagnostic performance and the incidence of non-diagnostic results, inconclusive results, conclusive results, malignancy, unnecessary surgery, and complications were analyzed. Subgroup analysis according to nodule size was performed. The risk factors associated with inconclusive results were evaluated using multivariate logistic regression analysis. RESULTS: A total of 93 patients (102 thyroid nodules) were evaluated. All samples obtained from CNB were adequate for diagnosis. Inconclusive results were seen in 12.7% of cases. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy were 93.8%, 100%, 100%, 78.9%, and 95%, respectively. None of the patients underwent unnecessary surgery. The diagnostic performance was not significantly different according to nodule size. On multivariate logistic regression analysis, larger nodule size and shorter needle length were independent risk factors associated with inconclusive results. CONCLUSION: Samples obtained by CNB were sufficient for diagnosis in all cases and resulted in high diagnostic values and conclusive results in the evaluation of suspicious thyroid nodules. These findings indicated that CNB is a promising diagnostic tool for suspicious thyroid nodules.
Biopsy, Fine-Needle
;
Biopsy, Large-Core Needle*
;
Diagnosis
;
Humans
;
Incidence
;
Logistic Models
;
Needles
;
Prospective Studies
;
Risk Factors
;
Sensitivity and Specificity
;
Thyroid Gland*
;
Thyroid Nodule*
;
Ultrasonography*
;
Unnecessary Procedures

Result Analysis
Print
Save
E-mail