1.Niraparib in Japanese patients with heavily pretreated, homologous recombination-deficient ovarian cancer: final results of a multicenter phase 2 study
Daisuke AOKI ; Tsutomu TABATA ; Satoshi YANAGIDA ; Toshiaki NAKAMURA ; Eiji KONDO ; Junzo HAMANISHI ; Kenichi HARANO ; Kosei HASEGAWA ; Takeshi HIRASAWA ; Kensuke HORI ; Shinichi KOMIYAMA ; Motoki MATSUURA ; Hidekatsu NAKAI ; Hiroko NAKAMURA ; Jun SAKATA ; Kazuhiro TAKEHARA ; Munetaka TAKEKUMA ; Yoshihito YOKOYAMA ; Yoichi KASE ; Shuuji SUMINO ; Junpei SOEDA ; Ai KATO ; Ajit SURI ; Aikou OKAMOTO ; Toru SUGIYAMA
Journal of Gynecologic Oncology 2024;35(5):e114-
Objective:
To evaluate the long-term efficacy and safety of niraparib in Japanese women with heavily pretreated ovarian cancer.
Methods:
This was the follow-up analysis of a phase 2, multicenter, open-label, single-arm study in Japanese women with homologous recombination-deficient, platinum-sensitive, relapsed, high-grade serous epithelial ovarian, fallopian tube, or primary peritoneal cancer who had completed 3–4 lines of chemotherapy and were poly(ADP-ribose) polymerase inhibitor naïve. Participants received niraparib (starting dose, 300 mg) once daily in continuous 28-day cycles until objective disease progression, unacceptable toxicity, or consent withdrawal. The primary endpoint was confirmed objective response rate (ORR), as assessed using Response Evaluation Criteria in Solid Tumors version 1.1. Safety evaluations included treatment-emergent adverse events (TEAEs).
Results:
20 patients were enrolled in the study and included in both efficacy and safety analyses. Median total study duration was 759.5 days. Median dose intensity was 201.3 mg/ day. Confirmed ORR was 60.0% (90% confidence interval [CI]=39.4–78.3); 2 patients had complete response and 10 patients had partial response. Median duration of response was 9.9 months (95% CI=3.9–26.9) and the disease control rate was 90.0% (95% CI=68.3–98.8).The most common TEAEs were anemia (n=15), nausea (n=12), and decreased platelet count (n=11). TEAEs leading to study drug dose reduction, interruption, or discontinuation were reported in 16 (80.0%), 15 (75.0%), and 2 patients (10.0%), respectively.
Conclusion
The long-term efficacy and safety profile of niraparib was consistent with previous findings in the equivalent population in non-Japanese patients. No new safety signals were identified.
2.Niraparib in Japanese patients with heavily pretreated, homologous recombination-deficient ovarian cancer: final results of a multicenter phase 2 study
Daisuke AOKI ; Tsutomu TABATA ; Satoshi YANAGIDA ; Toshiaki NAKAMURA ; Eiji KONDO ; Junzo HAMANISHI ; Kenichi HARANO ; Kosei HASEGAWA ; Takeshi HIRASAWA ; Kensuke HORI ; Shinichi KOMIYAMA ; Motoki MATSUURA ; Hidekatsu NAKAI ; Hiroko NAKAMURA ; Jun SAKATA ; Kazuhiro TAKEHARA ; Munetaka TAKEKUMA ; Yoshihito YOKOYAMA ; Yoichi KASE ; Shuuji SUMINO ; Junpei SOEDA ; Ai KATO ; Ajit SURI ; Aikou OKAMOTO ; Toru SUGIYAMA
Journal of Gynecologic Oncology 2024;35(5):e114-
Objective:
To evaluate the long-term efficacy and safety of niraparib in Japanese women with heavily pretreated ovarian cancer.
Methods:
This was the follow-up analysis of a phase 2, multicenter, open-label, single-arm study in Japanese women with homologous recombination-deficient, platinum-sensitive, relapsed, high-grade serous epithelial ovarian, fallopian tube, or primary peritoneal cancer who had completed 3–4 lines of chemotherapy and were poly(ADP-ribose) polymerase inhibitor naïve. Participants received niraparib (starting dose, 300 mg) once daily in continuous 28-day cycles until objective disease progression, unacceptable toxicity, or consent withdrawal. The primary endpoint was confirmed objective response rate (ORR), as assessed using Response Evaluation Criteria in Solid Tumors version 1.1. Safety evaluations included treatment-emergent adverse events (TEAEs).
Results:
20 patients were enrolled in the study and included in both efficacy and safety analyses. Median total study duration was 759.5 days. Median dose intensity was 201.3 mg/ day. Confirmed ORR was 60.0% (90% confidence interval [CI]=39.4–78.3); 2 patients had complete response and 10 patients had partial response. Median duration of response was 9.9 months (95% CI=3.9–26.9) and the disease control rate was 90.0% (95% CI=68.3–98.8).The most common TEAEs were anemia (n=15), nausea (n=12), and decreased platelet count (n=11). TEAEs leading to study drug dose reduction, interruption, or discontinuation were reported in 16 (80.0%), 15 (75.0%), and 2 patients (10.0%), respectively.
Conclusion
The long-term efficacy and safety profile of niraparib was consistent with previous findings in the equivalent population in non-Japanese patients. No new safety signals were identified.
3.Niraparib in Japanese patients with heavily pretreated, homologous recombination-deficient ovarian cancer: final results of a multicenter phase 2 study
Daisuke AOKI ; Tsutomu TABATA ; Satoshi YANAGIDA ; Toshiaki NAKAMURA ; Eiji KONDO ; Junzo HAMANISHI ; Kenichi HARANO ; Kosei HASEGAWA ; Takeshi HIRASAWA ; Kensuke HORI ; Shinichi KOMIYAMA ; Motoki MATSUURA ; Hidekatsu NAKAI ; Hiroko NAKAMURA ; Jun SAKATA ; Kazuhiro TAKEHARA ; Munetaka TAKEKUMA ; Yoshihito YOKOYAMA ; Yoichi KASE ; Shuuji SUMINO ; Junpei SOEDA ; Ai KATO ; Ajit SURI ; Aikou OKAMOTO ; Toru SUGIYAMA
Journal of Gynecologic Oncology 2024;35(5):e114-
Objective:
To evaluate the long-term efficacy and safety of niraparib in Japanese women with heavily pretreated ovarian cancer.
Methods:
This was the follow-up analysis of a phase 2, multicenter, open-label, single-arm study in Japanese women with homologous recombination-deficient, platinum-sensitive, relapsed, high-grade serous epithelial ovarian, fallopian tube, or primary peritoneal cancer who had completed 3–4 lines of chemotherapy and were poly(ADP-ribose) polymerase inhibitor naïve. Participants received niraparib (starting dose, 300 mg) once daily in continuous 28-day cycles until objective disease progression, unacceptable toxicity, or consent withdrawal. The primary endpoint was confirmed objective response rate (ORR), as assessed using Response Evaluation Criteria in Solid Tumors version 1.1. Safety evaluations included treatment-emergent adverse events (TEAEs).
Results:
20 patients were enrolled in the study and included in both efficacy and safety analyses. Median total study duration was 759.5 days. Median dose intensity was 201.3 mg/ day. Confirmed ORR was 60.0% (90% confidence interval [CI]=39.4–78.3); 2 patients had complete response and 10 patients had partial response. Median duration of response was 9.9 months (95% CI=3.9–26.9) and the disease control rate was 90.0% (95% CI=68.3–98.8).The most common TEAEs were anemia (n=15), nausea (n=12), and decreased platelet count (n=11). TEAEs leading to study drug dose reduction, interruption, or discontinuation were reported in 16 (80.0%), 15 (75.0%), and 2 patients (10.0%), respectively.
Conclusion
The long-term efficacy and safety profile of niraparib was consistent with previous findings in the equivalent population in non-Japanese patients. No new safety signals were identified.
4.Rotatable sphincterotome as a rescue device for endoscopic retrograde cholangiopancreatography cannulation: a single-center experience
Takeshi OKAMOTO ; Takashi SASAKI ; Tsuyoshi TAKEDA ; Takafumi MIE ; Chinatsu MORI ; Takaaki FURUKAWA ; Yuto YAMADA ; Akiyoshi KASUGA ; Masato MATSUYAMA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2024;57(1):96-104
Background/Aims:
Selective bile duct or pancreatic duct cannulation remains a significant initial hurdle in endoscopic retrograde cholangiopancreatography (ERCP) despite advances in endoscopy and accessories. This study evaluated our experience with a rotatable sphincterotome in cases of difficult cannulation.
Methods:
We retrospectively reviewed ERCP cases using TRUEtome, a rotatable sphincterotome, as a rescue device for cannulation at a cancer institute in Japan from October 2014 to December 2021.
Results:
TRUEtome was used in 88 patients. Duodenoscopes were used for 51 patients, while single-balloon enteroscopes (SBE) were used for 37 patients. TRUEtome was used for biliary and pancreatic duct cannulation (84.1%), intrahepatic bile duct selection (12.5%), and strictures of the afferent limb (3.4%). Cannulation success rates were similar in the duodenoscope and SBE groups (86.3% vs. 75.7%, p=0.213). TRUEtome was more commonly used in cases with steep cannulation angles in the duodenoscope group and in cases requiring cannulation in different directions in the SBE group. There were no significant differences in adverse events between the two groups.
Conclusions
The cannulation sphincterotome was useful for difficult cannulations in both unaltered and surgically altered anatomies. It may be an option to consider before high-risk procedures such as precut and endoscopic ultrasound-guided rendezvous techniques.
5.Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study
Takeshi OKAMOTO ; Takashi SASAKI ; Tsuyoshi TAKEDA ; Tatsuki HIRAI ; Takahiro ISHITSUKA ; Manabu YAMADA ; Hiroki NAKAGAWA ; Takafumi MIE ; Takaaki FURUKAWA ; Akiyoshi KASUGA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2024;57(4):515-526
Background/Aims:
The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO).
Methods:
Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared.
Results:
Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7% vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS.
Conclusions
No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.
6.Risk factors for recurrent stenosis after balloon dilation for benign hepaticojejunostomy anastomotic stricture
Takafumi MIE ; Takashi SASAKI ; Takeshi OKAMOTO ; Tsuyoshi TAKEDA ; Chinatsu MORI ; Yuto YAMADA ; Takaaki FURUKAWA ; Akiyoshi KASUGA ; Masato MATSUYAMA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2024;57(2):253-262
Background/Aims:
Hepaticojejunostomy anastomotic stricture (HJAS) is a feared adverse event associated with hepatopancreatobiliary surgery. Although balloon dilation for benign HJAS during endoscopic retrograde cholangiopancreatography with balloon-assisted enteroscopy has been reported to be useful, the treatment strategy remains controversial. Therefore, we evaluated the outcomes and risk factors of recurrent stenosis after balloon dilation alone for benign HJAS.
Methods:
We retrospectively analyzed consecutive patients who underwent balloon-assisted enteroscopy–endoscopic retrograde cholangiopancreatography for benign HJAS at our institution between July 2014 and December 2020.
Results:
Forty-six patients were included, 16 of whom had recurrent HJAS after balloon dilation. The patency rates at 1 and 2 years after balloon dilation were 76.8% and 64.2%, respectively. Presence of a residual balloon notch during balloon dilation was an independent predictor of recurrence (hazard ratio, 2.80; 95% confidence interval, 1.01–7.78; p=0.048), whereas HJAS within postoperative 1 year tended to be associated with recurrence (hazard ratio, 2.43; 95% confidence interval, 0.85–6.89; p=0.096). The patency rates in patients without a residual balloon notch were 82.1% and 73.1% after 1 and 2 years, respectively.
Conclusions
Balloon dilation alone may be a viable option for patients with benign HJAS without residual balloon notches on fluoroscopy.
7.Intralesional steroid infusion using a spray tube to prevent stenosis after endoscopic submucosal dissection of esophageal cancer
Atsushi GOTO ; Takeshi OKAMOTO ; Ryo OGAWA ; Kouichi HAMABE ; Shinichi HASHIMOTO ; Jun NISHIKAWA ; Taro TAKAMI
Clinical Endoscopy 2022;55(4):520-524
Background/Aims:
Intralesional steroid injections have been administered as prophylaxis for stenosis after esophageal endoscopic submucosal dissection. However, this method carries a risk of potential complications such as perforation because a fine needle is used to directly puncture the postoperative ulcer. We devised a new method of steroid intralesional infusion using a spray tube and evaluated its efficacy and safety.
Methods:
Intralesional steroid infusion using a spray tube was performed on 27 patients who underwent endoscopic submucosal dissection for superficial esophageal cancer with three-quarters or more of the lumen circumference resected. The presence or absence of stenosis, complications, and the number of endoscopic balloon dilations (EBDs) performed were evaluated after treatment.
Results:
Although stenosis was not observed in 22 of the 27 patients, five patients had stenosis and dysphagia requiring EBD. The stenosis in these five patients was relieved after four EBDs. No complications related to intralesional steroid infusion using the spray tube were observed.
Conclusions
Intralesional steroid infusion using a spray tube is a simple and safe technique that is adequately effective in preventing stenosis Clinical trial number (UMIN000037567).
8.Comparison of tube-assisted mapping biopsy with digital single-operator peroral cholangioscopy for preoperative evaluation of biliary tract cancer
Tsuyoshi TAKEDA ; Takashi SASAKI ; Takafumi MIE ; Takeshi OKAMOTO ; Chinatsu MORI ; Takaaki FURUKAWA ; Yuto YAMADA ; Akiyoshi KASUGA ; Masato MATSUYAMA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2022;55(4):549-557
Background/Aims:
Digital single-operator cholangioscopy (DSOC)-guided mapping biopsy (DMB) and tube-assisted mapping biopsy (TMB) are two techniques used for preoperative evaluation of biliary tract cancer (BTC). However, data regarding the diagnostic performance of these techniques are limited.
Methods:
We retrospectively examined consecutive patients with BTC who underwent either technique at our institution between 2018 and 2020. We evaluated the technical success rate, adequate tissue acquisition rate, and diagnostic performance of these techniques for the evaluation of lateral spread of BTC.
Results:
A total of 54 patients were included in the study. The technical success rate of reaching the target sites was 95% for DMB and 100% for TMB. The adequate tissue acquisition rate was 61% for DMB and 69% for TMB. The adequate tissue acquisition rate was low, especially for target sites beyond the secondary biliary radicles. The sensitivity of DMB alone was 39%, which improved to 65% when combined with visual impression. Experts demonstrated a higher negative predictive value and diagnostic accuracy with respect to both DSOC visual impression and DMB for the evaluation of lateral spread of BTC compared to trainees.
Conclusions
Adequate tissue acquisition rates were similar between the two techniques. Since DMB requires expertise, TMB may be an acceptable option when DSOC is unavailable or when DSOC expertise is limited.
9.Bispectral index-guided propofol sedation during endoscopic ultrasonography
Ayana OKAMOTO ; Ken KAMATA ; Takeshi MIYATA ; Tomoe YOSHIKAWA ; Rei ISHIKAWA ; Tomohiro YAMAZAKI ; Atsushi NAKAI ; Shunsuke OMOTO ; Kosuke MINAGA ; Kentaro YAMAO ; Mamoru TAKENAKA ; Yasutaka CHIBA ; Toshiharu SAKURAI ; Naoshi NISHIDA ; Masayuki KITANO ; Masatoshi KUDO
Clinical Endoscopy 2022;55(4):558-563
Background/Aims:
Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS).
Methods:
This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room.
Results:
The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001).
Conclusions
During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.
10.Reflux-related Extraesophageal Symptoms Until Proven Otherwise: A Direct Measurement of Abnormal Proximal Exposure Based on Hypopharyngeal Multichannel Intraluminal Impedance as a Reliable Indicator for Successful Treatment Outcomes
Takeshi SUZUKI ; Yosuke SEKI ; Tomoaki MATSUMURA ; Makoto ARAI ; Toyoyuki HANAZAWA ; Yoshitaka OKAMOTO ; Haruhiko SUZUKI ; Kazunori KASAMA ; Akiko UMEZAWA ; Yoshimoti KUROKAWA ; Toshitaka HOPPO
Journal of Neurogastroenterology and Motility 2022;28(1):69-77
Background/Aims:
The Lyon Consensus defined parameters based on upper endoscopy and 24-hour combined multichannel intraluminal impedancepH (MII-pH), that conclusively establish the presence of gastroesophageal reflux disease (GERD). However, the true role of upper endoscopy and MII-pH to evaluate patients with extraesophageal symptoms (EES) has not been well established. Hypopharyngeal MII (HMII), which directly measures laryngopharyngeal reflux (LPR) events, has been utilized to evaluate patients with EES suggestive of LPR.
Methods:
This was a retrospective study involving patients with EES for > 12 weeks despite proton pump inhibitor therapy, and had no endoscopic confirmatory evidence for GERD and negative MII-pH. All patients were subsequently referred for further evaluation of EES with “unknown” etiology and underwent laryngoscopy and HMII. Based on HMII, abnormal proximal exposure (APE) was defined as LPR ≥ 1/day and/or full column reflux (reflux 2 cm distal to the upper esophageal sphincter) > 4/day. Patients with APE were offered antireflux surgery (ARS) and the outcome of ARS was objectively assessed using Reflux Symptom Index.
Results:
Of 21 patients with EES which was thought to be GERD-unrelated based on endoscopy and MII-pH, 17 patients (81%) had APE. Eight patients with APE who had undergone ARS had significant symptomatic improvement in the Reflux Symptom Index score (19.6 ± 4.9 pre-ARS to 5.8 ± 1.4 post-ARS, P = 0.008).
Conclusions
A conventional diagnostic approach using endoscopy and MII-pH may not be sufficient to evaluate patients with EES suggestive of LPR. HMII is essential to evaluate patients with EES, and APE could be a reliable indicator for successful treatment outcomes.

Result Analysis
Print
Save
E-mail