1.Drainage for fluid collections post pancreatic surgery and acute pancreatitis: similar but different?
Yousuke NAKAI ; Saburo MATSUBARA ; Tsuyoshi MUKAI ; Tsuyoshi HAMADA ; Takashi SASAKI ; Hirotoshi ISHIWATARI ; Susumu HIJIOKA ; Hideyuki SHIOMI ; Mamoru TAKENAKA ; Takuji IWASHITA ; Atsuhiro MASUDA ; Tomotaka SAITO ; Hiroyuki ISAYAMA ; Ichiro YASUDA ;
Clinical Endoscopy 2024;57(6):735-746
Postoperative pancreatic fistulas (POPFs) are common adverse events that occur after pancreatic surgery. Endoscopic ultrasonography (EUS)-guided drainage (EUS-D) is a first-line treatment, similar to that for pancreatic fluid collection (PFCs) after acute pancreatitis. However, some POPFs do not develop fluid collections depending on the presence or location of the surgical drain, whereas others develop fluid collections, such as postoperative fluid collections (POPFCs). Although POPFCs are similar to PFCs, the strategy and modality for POPF management need to be modified according to the presence of fluid collections, surgical drains, and surgical type. As discussed for PFCs, the indications, timing, and selection of interventions or stents for EUS-D have not been fully elucidated for POPFs. In this review, we discuss the management of POPFs and POPFCs in comparison with PFCs due to acute pancreatitis and summarize the topics that should be addressed in future studies.
2.Drainage for fluid collections post pancreatic surgery and acute pancreatitis: similar but different?
Yousuke NAKAI ; Saburo MATSUBARA ; Tsuyoshi MUKAI ; Tsuyoshi HAMADA ; Takashi SASAKI ; Hirotoshi ISHIWATARI ; Susumu HIJIOKA ; Hideyuki SHIOMI ; Mamoru TAKENAKA ; Takuji IWASHITA ; Atsuhiro MASUDA ; Tomotaka SAITO ; Hiroyuki ISAYAMA ; Ichiro YASUDA ;
Clinical Endoscopy 2024;57(6):735-746
Postoperative pancreatic fistulas (POPFs) are common adverse events that occur after pancreatic surgery. Endoscopic ultrasonography (EUS)-guided drainage (EUS-D) is a first-line treatment, similar to that for pancreatic fluid collection (PFCs) after acute pancreatitis. However, some POPFs do not develop fluid collections depending on the presence or location of the surgical drain, whereas others develop fluid collections, such as postoperative fluid collections (POPFCs). Although POPFCs are similar to PFCs, the strategy and modality for POPF management need to be modified according to the presence of fluid collections, surgical drains, and surgical type. As discussed for PFCs, the indications, timing, and selection of interventions or stents for EUS-D have not been fully elucidated for POPFs. In this review, we discuss the management of POPFs and POPFCs in comparison with PFCs due to acute pancreatitis and summarize the topics that should be addressed in future studies.
3.Drainage for fluid collections post pancreatic surgery and acute pancreatitis: similar but different?
Yousuke NAKAI ; Saburo MATSUBARA ; Tsuyoshi MUKAI ; Tsuyoshi HAMADA ; Takashi SASAKI ; Hirotoshi ISHIWATARI ; Susumu HIJIOKA ; Hideyuki SHIOMI ; Mamoru TAKENAKA ; Takuji IWASHITA ; Atsuhiro MASUDA ; Tomotaka SAITO ; Hiroyuki ISAYAMA ; Ichiro YASUDA ;
Clinical Endoscopy 2024;57(6):735-746
Postoperative pancreatic fistulas (POPFs) are common adverse events that occur after pancreatic surgery. Endoscopic ultrasonography (EUS)-guided drainage (EUS-D) is a first-line treatment, similar to that for pancreatic fluid collection (PFCs) after acute pancreatitis. However, some POPFs do not develop fluid collections depending on the presence or location of the surgical drain, whereas others develop fluid collections, such as postoperative fluid collections (POPFCs). Although POPFCs are similar to PFCs, the strategy and modality for POPF management need to be modified according to the presence of fluid collections, surgical drains, and surgical type. As discussed for PFCs, the indications, timing, and selection of interventions or stents for EUS-D have not been fully elucidated for POPFs. In this review, we discuss the management of POPFs and POPFCs in comparison with PFCs due to acute pancreatitis and summarize the topics that should be addressed in future studies.
4.Rotatable sphincterotome as a rescue device for endoscopic retrograde cholangiopancreatography cannulation: a single-center experience
Takeshi OKAMOTO ; Takashi SASAKI ; Tsuyoshi TAKEDA ; Takafumi MIE ; Chinatsu MORI ; Takaaki FURUKAWA ; Yuto YAMADA ; Akiyoshi KASUGA ; Masato MATSUYAMA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2024;57(1):96-104
Background/Aims:
Selective bile duct or pancreatic duct cannulation remains a significant initial hurdle in endoscopic retrograde cholangiopancreatography (ERCP) despite advances in endoscopy and accessories. This study evaluated our experience with a rotatable sphincterotome in cases of difficult cannulation.
Methods:
We retrospectively reviewed ERCP cases using TRUEtome, a rotatable sphincterotome, as a rescue device for cannulation at a cancer institute in Japan from October 2014 to December 2021.
Results:
TRUEtome was used in 88 patients. Duodenoscopes were used for 51 patients, while single-balloon enteroscopes (SBE) were used for 37 patients. TRUEtome was used for biliary and pancreatic duct cannulation (84.1%), intrahepatic bile duct selection (12.5%), and strictures of the afferent limb (3.4%). Cannulation success rates were similar in the duodenoscope and SBE groups (86.3% vs. 75.7%, p=0.213). TRUEtome was more commonly used in cases with steep cannulation angles in the duodenoscope group and in cases requiring cannulation in different directions in the SBE group. There were no significant differences in adverse events between the two groups.
Conclusions
The cannulation sphincterotome was useful for difficult cannulations in both unaltered and surgically altered anatomies. It may be an option to consider before high-risk procedures such as precut and endoscopic ultrasound-guided rendezvous techniques.
5.Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study
Takeshi OKAMOTO ; Takashi SASAKI ; Tsuyoshi TAKEDA ; Tatsuki HIRAI ; Takahiro ISHITSUKA ; Manabu YAMADA ; Hiroki NAKAGAWA ; Takafumi MIE ; Takaaki FURUKAWA ; Akiyoshi KASUGA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2024;57(4):515-526
Background/Aims:
The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO).
Methods:
Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared.
Results:
Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7% vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS.
Conclusions
No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.
6.Risk factors for recurrent stenosis after balloon dilation for benign hepaticojejunostomy anastomotic stricture
Takafumi MIE ; Takashi SASAKI ; Takeshi OKAMOTO ; Tsuyoshi TAKEDA ; Chinatsu MORI ; Yuto YAMADA ; Takaaki FURUKAWA ; Akiyoshi KASUGA ; Masato MATSUYAMA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2024;57(2):253-262
Background/Aims:
Hepaticojejunostomy anastomotic stricture (HJAS) is a feared adverse event associated with hepatopancreatobiliary surgery. Although balloon dilation for benign HJAS during endoscopic retrograde cholangiopancreatography with balloon-assisted enteroscopy has been reported to be useful, the treatment strategy remains controversial. Therefore, we evaluated the outcomes and risk factors of recurrent stenosis after balloon dilation alone for benign HJAS.
Methods:
We retrospectively analyzed consecutive patients who underwent balloon-assisted enteroscopy–endoscopic retrograde cholangiopancreatography for benign HJAS at our institution between July 2014 and December 2020.
Results:
Forty-six patients were included, 16 of whom had recurrent HJAS after balloon dilation. The patency rates at 1 and 2 years after balloon dilation were 76.8% and 64.2%, respectively. Presence of a residual balloon notch during balloon dilation was an independent predictor of recurrence (hazard ratio, 2.80; 95% confidence interval, 1.01–7.78; p=0.048), whereas HJAS within postoperative 1 year tended to be associated with recurrence (hazard ratio, 2.43; 95% confidence interval, 0.85–6.89; p=0.096). The patency rates in patients without a residual balloon notch were 82.1% and 73.1% after 1 and 2 years, respectively.
Conclusions
Balloon dilation alone may be a viable option for patients with benign HJAS without residual balloon notches on fluoroscopy.
7.Evaluation of the mechanical properties of current biliary self-expandable metallic stents: axial and radial force, and axial force zero border
Wataru YAMAGATA ; Toshio FUJISAWA ; Takashi SASAKI ; Rei ISHIBASHI ; Tomotaka SAITO ; Shuntaro YOSHIDA ; Shizuka NO ; Kouta INOUE ; Yousuke NAKAI ; Naoki SASAHIRA ; Hiroyuki ISAYAMA
Clinical Endoscopy 2023;56(5):633-649
Background/Aims:
Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability.
Methods:
We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated.
Results:
A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types.
Conclusions
MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.
8.Comparison of tube-assisted mapping biopsy with digital single-operator peroral cholangioscopy for preoperative evaluation of biliary tract cancer
Tsuyoshi TAKEDA ; Takashi SASAKI ; Takafumi MIE ; Takeshi OKAMOTO ; Chinatsu MORI ; Takaaki FURUKAWA ; Yuto YAMADA ; Akiyoshi KASUGA ; Masato MATSUYAMA ; Masato OZAKA ; Naoki SASAHIRA
Clinical Endoscopy 2022;55(4):549-557
Background/Aims:
Digital single-operator cholangioscopy (DSOC)-guided mapping biopsy (DMB) and tube-assisted mapping biopsy (TMB) are two techniques used for preoperative evaluation of biliary tract cancer (BTC). However, data regarding the diagnostic performance of these techniques are limited.
Methods:
We retrospectively examined consecutive patients with BTC who underwent either technique at our institution between 2018 and 2020. We evaluated the technical success rate, adequate tissue acquisition rate, and diagnostic performance of these techniques for the evaluation of lateral spread of BTC.
Results:
A total of 54 patients were included in the study. The technical success rate of reaching the target sites was 95% for DMB and 100% for TMB. The adequate tissue acquisition rate was 61% for DMB and 69% for TMB. The adequate tissue acquisition rate was low, especially for target sites beyond the secondary biliary radicles. The sensitivity of DMB alone was 39%, which improved to 65% when combined with visual impression. Experts demonstrated a higher negative predictive value and diagnostic accuracy with respect to both DSOC visual impression and DMB for the evaluation of lateral spread of BTC compared to trainees.
Conclusions
Adequate tissue acquisition rates were similar between the two techniques. Since DMB requires expertise, TMB may be an acceptable option when DSOC is unavailable or when DSOC expertise is limited.
9.Stand-Alone Anterior Cervical Discectomy and Fusion Using an Additive Manufactured Individualized Bioactive Porous Titanium Implant without Bone Graft: Results of a Prospective Clinical Trial
Shunsuke FUJIBAYASHI ; Mitsuru TAKEMOTO ; Takashi NAKAMURA ; Tomiharu MATSUSHITA ; Tadashi KOKUBO ; Kiyoyuki SASAKI ; Shigeo MORI ; Shuichi MATSUDA
Asian Spine Journal 2021;15(3):373-380
The purpose of this study was to introduce our patient-specific bioactive porous titanium implant manufactured using selective laser melting (SLM) and to establish the efficacy and safety of the implant for stand-alone anterior cervical discectomy and fusion (ACDF) based on a prospective clinical trial. We designed a customized ACDF implant using patient-specific data and manufactured the implant using SLM. We produced a bioactive surface through a specific chemical and thermal treatment. Using this implant, we surgically treated four patients with cervical degenerative disc disease and evaluated the clinical and radiological results. We achieved successful bony union in all but one patient without autologous bone grafting within 1 year. We observed no implant subsidence during the follow-up period, and all clinical parameters improved significantly after surgery, with no reported implant-related adverse effects. Our customized bioactive porous titanium implant is a safe and promising implant for stand-alone ACDF.

Result Analysis
Print
Save
E-mail