1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
		                        		
		                        			 Background and Objectives:
		                        			Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR. 
		                        		
		                        			Methods:
		                        			All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment. 
		                        		
		                        			Results:
		                        			A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period. 
		                        		
		                        			Conclusions
		                        			The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect. 
		                        		
		                        		
		                        		
		                        	
5.Clinical Practice Guideline for Blood-based Circulating Tumor DNA Assays
Jee-Soo LEE ; Eun Hye CHO ; Boram KIM ; Jinyoung HONG ; Young-gon KIM ; Yoonjung KIM ; Ja-Hyun JANG ; Seung-Tae LEE ; Sun-Young KONG ; Woochang LEE ; Saeam SHIN ; Eun Young SONG ;
Annals of Laboratory Medicine 2024;44(3):195-209
		                        		
		                        			
		                        			 Circulating tumor DNA (ctDNA) has emerged as a promising tool for various clinical applications, including early diagnosis, therapeutic target identification, treatment response monitoring, prognosis evaluation, and minimal residual disease detection. Consequently, ctDNA assays have been incorporated into clinical practice. In this review, we offer an indepth exploration of the clinical implementation of ctDNA assays. Notably, we examined existing evidence related to pre-analytical procedures, analytical components in current technologies, and result interpretation and reporting processes. The primary objective of this guidelines is to provide recommendations for the clinical utilization of ctDNA assays. 
		                        		
		                        		
		                        		
		                        	
6.Study Design and Protocol for a Randomized Controlled Trial to Assess Long-Term Efficacy and Safety of a Triple Combination of Ezetimibe, Fenofibrate, and Moderate-Intensity Statin in Patients with Type 2 Diabetes and Modifiable Cardiovascular Risk Factors (ENSEMBLE)
Nam Hoon KIM ; Juneyoung LEE ; Suk CHON ; Jae Myung YU ; In-Kyung JEONG ; Soo LIM ; Won Jun KIM ; Keeho SONG ; Ho Chan CHO ; Hea Min YU ; Kyoung-Ah KIM ; Sang Soo KIM ; Soon Hee LEE ; Chong Hwa KIM ; Soo Heon KWAK ; Yong‐ho LEE ; Choon Hee CHUNG ; Sihoon LEE ; Heung Yong JIN ; Jae Hyuk LEE ; Gwanpyo KOH ; Sang-Yong KIM ; Jaetaek KIM ; Ju Hee LEE ; Tae Nyun KIM ; Hyun Jeong JEON ; Ji Hyun LEE ; Jae-Han JEON ; Hye Jin YOO ; Hee Kyung KIM ; Hyeong-Kyu PARK ; Il Seong NAM-GOONG ; Seongbin HONG ; Chul Woo AHN ; Ji Hee YU ; Jong Heon PARK ; Keun-Gyu PARK ; Chan Ho PARK ; Kyong Hye JOUNG ; Ohk-Hyun RYU ; Keun Yong PARK ; Eun-Gyoung HONG ; Bong-Soo CHA ; Kyu Chang WON ; Yoon-Sok CHUNG ; Sin Gon KIM
Endocrinology and Metabolism 2024;39(5):722-731
		                        		
		                        			 Background:
		                        			Atherogenic dyslipidemia, which is frequently associated with type 2 diabetes (T2D) and insulin resistance, contributes to the development of vascular complications. Statin therapy is the primary approach to dyslipidemia management in T2D, however, the role of non-statin therapy remains unclear. Ezetimibe reduces cholesterol burden by inhibiting intestinal cholesterol absorption. Fibrates lower triglyceride levels and increase high-density lipoprotein cholesterol (HDL-C) levels via peroxisome proliferator- activated receptor alpha agonism. Therefore, when combined, these drugs effectively lower non-HDL-C levels. Despite this, few clinical trials have specifically targeted non-HDL-C, and the efficacy of triple combination therapies, including statins, ezetimibe, and fibrates, has yet to be determined. 
		                        		
		                        			Methods:
		                        			This is a multicenter, prospective, randomized, open-label, active-comparator controlled trial involving 3,958 eligible participants with T2D, cardiovascular risk factors, and elevated non-HDL-C (≥100 mg/dL). Participants, already on moderate-intensity statins, will be randomly assigned to either Ezefeno (ezetimibe/fenofibrate) addition or statin dose-escalation. The primary end point is the development of a composite of major adverse cardiovascular and diabetic microvascular events over 48 months. 
		                        		
		                        			Conclusion
		                        			This trial aims to assess whether combining statins, ezetimibe, and fenofibrate is as effective as, or possibly superior to, statin monotherapy intensification in lowering cardiovascular and microvascular disease risk for patients with T2D. This could propose a novel therapeutic approach for managing dyslipidemia in T2D. 
		                        		
		                        		
		                        		
		                        	
7.A Novel Retractable Robotic Device for Colorectal Endoscopic Submucosal Dissection
Sang Hyun KIM ; Chanwoo KIM ; Bora KEUM ; Junghyun IM ; Seonghyeon WON ; Byung Gon KIM ; Kyungnam KIM ; Taebin KWON ; Daehie HONG ; Han Jo JEON ; Hyuk Soon CHOI ; Eun Sun KIM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Joo Ha HWANG
Gut and Liver 2024;18(4):377-385
		                        		
		                        			 Background/Aims:
		                        			Appropriate tissue tension and clear visibility of the dissection area using traction are essential for effective and safe endoscopic submucosal dissection (ESD). In this study, we developed a retractable robot-assisted traction device and evaluated its performance in colorectal ESD. 
		                        		
		                        			Methods:
		                        			An experienced endoscopist performed ESD 18 times on an ex vivo porcine colon using the robot and 18 times using the conventional method. The outcome measures were procedure time, dissection speed, procedure-related adverse events, and blind dissection rate. 
		                        		
		                        			Results:
		                        			Thirty-six colonic lesions were resected from ex vivo porcine colon samples. The total procedure time was significantly shorter in robot-assisted ESD (RESD) than in conventional ESD (CESD) (20.1±4.1 minutes vs 34.3±8.3 minutes, p<0.05). The submucosal dissection speed was significantly faster in the RESD group than in the CESD group (36.8±9.2 mm 2 /min vs 18.1±4.7 mm 2 /min, p<0.05). The blind dissection rate was also significantly lower in the RESD group (12.8%±3.4% vs 35.1%±3.9%, p<0.05). In an in vivo porcine feasibility study, the robotic device was attached to a colonoscope and successfully inserted into the proximal colon without damaging the colonic wall, and ESD was successfully performed. 
		                        		
		                        			Conclusions
		                        			The dissection speed and safety profile improved significantly with the retractable RESD. Thus, our robotic device has the potential to provide simple, effective, and safe multidirectional traction during colonic ESD. 
		                        		
		                        		
		                        		
		                        	
8.Benign Prostatic Hyperplasia and the Risk of Falls in Older Men: Insights From a Population-Based Study on Geriatric Morbid Conditions
Sung Jin KIM ; Donghyun LEE ; Sung Gon PARK ; Sahyun PAK ; Young Goo LEE ; Sung Tae CHO
International Neurourology Journal 2024;28(1):44-51
		                        		
		                        			 Purpose:
		                        			The purpose of this study was to explore the association between benign prostatic hyperplasia (BPH) and the incidence of falls from the perspective of geriatric morbid conditions. 
		                        		
		                        			Methods:
		                        			Data were sourced from the triennial National Survey of Older Koreans conducted by the Ministry of Health and Welfare (2017–2020). In total, 8,135 male participants aged 65 and older were included, and information was gathered through questionnaires and physical measurements. Logistic regression analysis was utilized to determine the impact of BPH on the risk of falls, and subgroup analyses were conducted to examine the influence of BPH on specific types of falls. 
		                        		
		                        			Results:
		                        			Of the participants, 15.2% (1,238 of 8,135) reported that their BPH treatment exceeded 3 months, and 8.0% (648 of 8,135) reported experiencing falls, with 61.4% (398/648) of these falls resulting in injuries. A significant association was identified between BPH and both falls (odds ratio [OR], 1.798; 95% confidence interval [CI], 1.479–2.185) and falls with injuries (OR, 2.133; 95% CI, 1.689–2.694). A subgroup analysis indicated a correlation between BPH and falls in groups having one (OR, 1.912; 95% CI, 1.356–2.694) and 2 or more conditions (OR, 1.856; 95% CI, 1.455–2.367) involving visual and auditory impairments, cognitive decline, depression, lower motor weakness, and limitations in daily activities. 
		                        		
		                        			Conclusions
		                        			The findings indicate that BPH contributes to the incidence of falls among older men, particularly those with comorbid conditions. Considering the heightened fall risk among elderly individuals suffering from multiple morbidities, particularly those with BPH, targeted interventions are essential for mitigating the risk of falls in this vulnerable group. 
		                        		
		                        		
		                        		
		                        	
9.Omission of Breast Surgery in Predicted Pathologic Complete Response after Neoadjuvant Systemic Therapy: A Multicenter, Single-Arm, Non-inferiority Trial
Ji-Jung JUNG ; Jong-Ho CHEUN ; Soo-Yeon KIM ; Jiwon KOH ; Jai Min RYU ; Tae-Kyung YOO ; Hee-Chul SHIN ; Sung Gwe AHN ; Seho PARK ; Woosung LIM ; Sang-Eun NAM ; Min Ho PARK ; Ku Sang KIM ; Taewoo KANG ; Jeeyeon LEE ; Hyun Jo YOUN ; Yoo Seok KIM ; Chang Ik YOON ; Hong-Kyu KIM ; Hyeong-Gon MOON ; Wonshik HAN ; Nariya CHO ; Min Kyoon KIM ; Han-Byoel LEE
Journal of Breast Cancer 2024;27(1):61-71
		                        		
		                        			 Purpose:
		                        			Advances in chemotherapeutic and targeted agents have increased pathologic complete response (pCR) rates after neoadjuvant systemic therapy (NST). Vacuum-assisted biopsy (VAB) has been suggested to accurately evaluate pCR. This study aims to confirm the non-inferiority of the 5-year disease-free survival of patients who omitted breast surgery when predicted to have a pCR based on breast magnetic resonance imaging (MRI) and VAB after NST, compared with patients with a pCR who had undergone breast surgery in previous studies. 
		                        		
		                        			Methods
		                        			The Omission of breast surgery for PredicTed pCR patients wIth MRI and vacuumassisted bIopsy in breaST cancer after neoadjuvant systemic therapy (OPTIMIST) trial is a prospective, multicenter, single-arm, non-inferiority study enrolling in 17 tertiary care hospitals in the Republic of Korea. Eligible patients must have a clip marker placed in the tumor and meet the MRI criteria suggesting complete clinical response (post-NST MRI size ≤ 1 cm and lesion-to-background signal enhancement ratio ≤ 1.6) after NST. Patients will undergo VAB, and breast surgery will be omitted for those with no residual tumor. Axillary surgery can also be omitted if the patient was clinically node-negative before and after NST and met the stringent criteria of MRI size ≤ 0.5 cm. Survival and efficacy outcomes are evaluated over five years.Discussion: This study seeks to establish evidence for the safe omission of breast surgery in exceptional responders to NST while minimizing patient burden. The trial will address concerns about potential undertreatment due to false-negative results and recurrence as well as improved patient-reported quality of life issues from the omission of surgery. Successful completion of this trial may reshape clinical practice for certain breast cancer subtypes and lead to a safe and less invasive approach for selected patients. 
		                        		
		                        		
		                        		
		                        	
10.Association Between Individual Air Pollution (PM 10 , PM2.5) Exposure and Adverse Pregnancy Outcomes in Korea: A Multicenter Prospective Cohort, Air Pollution on Pregnancy Outcome (APPO) Study
Tae Gyu AHN ; Young Ju KIM ; Gain LEE ; Young-Ah YOU ; Soo Min KIM ; Rin CHAE ; Young Min HUR ; Mi Hye PARK ; Jin-Gon BAE ; Soo-Jeong LEE ; Young-Han KIM ; Sunghun NA
Journal of Korean Medical Science 2024;39(13):e131-
		                        		
		                        			 Background:
		                        			Prenatal exposure to ambient air pollution is linked to a higher risk of unfavorable pregnancy outcomes. However, the association between pregnancy complications and exposure to indoor air pollution remains unclear. The Air Pollution on Pregnancy Outcomes research is a hospital-based prospective cohort research created to look into the effects of aerodynamically exposed particulate matter (PM) 10 and PM 2.5 on pregnancy outcomes. 
		                        		
		                        			Methods:
		                        			This prospective multicenter observational cohort study was conducted from January 2021 to June 2023. A total of 662 women with singleton pregnancies enrolled in this study. An AirguardK ® air sensor was installed inside the homes of the participants to measure the individual PM 10 and PM 2.5 levels in the living environment. The time–activity patterns and PM 100 and PM 2.5 , determined as concentrations from the time-weighted average model, were applied to determine the anticipated exposure levels to air pollution of each pregnant woman. The relationship between air pollution exposure and pregnancy outcomes was assessed using logistic and linear regression analyses. 
		                        		
		                        			Results:
		                        			Exposure to elevated levels of PM 10 throughout the first, second, and third trimesters as well as throughout pregnancy was strongly correlated with the risk of pregnancy problems according to multiple logistic regression models adjusted for variables. Except for in the third trimester of pregnancy, women exposed to high levels of PM 2.5 had a high risk of pregnancy complications. During the second trimester and entire pregnancy, the risk of preterm birth (PTB) increased by 24% and 27%, respectively, for each 10 μg/m 3 increase in PM 10. Exposure to high PM 10 levels during the second trimester increased the risk of gestational diabetes mellitus (GDM) by 30%. The risk of GDM increased by 15% for each 5 μg/m 3 increase in PM2.5 during the second trimester and overall pregnancy, respectively. Exposure to high PM  10 and PM 2.5 during the first trimester of pregnancy increased the risk of delivering small for gestational age (SGA) infants by 96% and 26%, respectively. 
		                        		
		                        			Conclusion
		                        			Exposure to high concentrations of PM 10 and PM 2.5 is strongly correlated with the risk of adverse pregnancy outcomes. Exposure to high levels of PM10 and PM2.5 during the second trimester and entire pregnancy, respectively, significantly increased the risk of PTB and GDM. Exposure to high levels of PM 10 and PM2.5 during the first trimester of pregnancy considerably increased the risk of having SGA infants. Our findings highlight the need to measure individual particulate levels during pregnancy and the importance of managing air quality in residential environment. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail