1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Caregiver Burden of Patients With Huntington’s Disease in South Korea
Chan Young LEE ; Chaewon SHIN ; Yun Su HWANG ; Eungseok OH ; Manho KIM ; Hyun Sook KIM ; Sun Ju CHUNG ; Young Hee SUNG ; Won Tae YOON ; Jin Whan CHO ; Jae-Hyeok LEE ; Han-Joon KIM ; Hee Jin CHANG ; Beomseok JEON ; Kyung Ah WOO ; Seong-Beom KOH ; Kyum-Yil KWON ; Jangsup MOON ; Young Eun KIM ; Jee-Young LEE
Journal of Movement Disorders 2024;17(1):30-37
Objective:
This is the first prospective cohort study of Huntington’s disease (HD) in Korea. This study aimed to investigate the caregiver burden in relation to the characteristics of patients and caregivers.
Methods:
From August 2020 to February 2022, we enrolled patients with HD from 13 university hospitals in Korea. We used the 12-item Zarit Burden Interview (ZBI-12) to evaluate the caregiver burden. We evaluated the clinical associations of the ZBI-12 scores by linear regression analysis and investigated the differences between the low- and high-burden groups.
Results:
Sixty-five patients with HD and 45 caregivers were enrolled in this cohort study. The average age at onset of motor symptoms was 49.3 ± 12.3 years, with an average cytosine-adenine-guanine (CAG)n of 42.9 ± 4.0 (38–65). The median ZBI-12 score among our caregivers was 17.6 ± 14.2. A higher caregiver burden was associated with a more severe Shoulson–Fahn stage (p = 0.038) of the patients. A higher ZBI-12 score was also associated with lower independence scale (B = -0.154, p = 0.006) and functional capacity (B = -1.082, p = 0.002) scores of patients. The caregiving duration was longer in the high- than in the low-burden group. Caregivers’ demographics, blood relation, and marital and social status did not affect the burden significantly.
Conclusion
HD patients’ neurological status exerts an enormous impact on the caregiver burden regardless of the demographic or social status of the caregiver. This study emphasizes the need to establish an optimal support system for families dealing with HD in Korea. A future longitudinal analysis could help us understand how disease progression aggravates the caregiver burden throughout the entire disease course.
6.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
7.Validity and Reliability of the Korean-Translated Version of the International Cooperative Ataxia Rating Scale in Cerebellar Ataxia
Jinse PARK ; Jin Whan CHO ; Jinyoung YOUN ; Engseok OH ; Wooyoung JANG ; Joong-Seok KIM ; Yoon-Sang OH ; Hyungyoung HWANG ; Chang-Hwan RYU ; Jin-Young AHN ; Jee-Young LEE ; Seong-Beom KOH ; Jae H. PARK ; Hee-Tae KIM
Journal of Movement Disorders 2023;16(1):86-90
Objective:
The International Cooperative Ataxia Rating Scale (ICARS) is a semiquantitative clinical scale for ataxia that is widely used in numerous countries. The purpose of this study was to investigate the validity and reliability of the Korean-translated version of the ICARS.
Methods:
Eighty-eight patients who presented with cerebellar ataxia were enrolled. We investigated the construct validity using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). We also investigated the internal consistency using Cronbach’s α and intrarater and interrater reliability using intraclass correlation coefficients.
Results:
The Korean-translated ICARS showed satisfactory construct validity using EFA and CFA. It also revealed good interrater and intrarater reliability and showed acceptable internal consistency. However, subscale 4 for assessing oculomotor disorder showed moderate internal consistency.
Conclusion
This is the first report to investigate the validity and reliability of the Korean-translated ICARS. Our results showed excellent construct and convergent validity. The reliability is also acceptable.
8.Validation Study of the Official Korean Version of the Movement Disorder Society-Unified Parkinson’s Disease Rating Scale
Jinse PARK ; Seong-Beom KOH ; Kyum-Yil KWON ; Sang Jin KIM ; Jae Woo KIM ; Joong-Seok KIM ; Kun-Woo PARK ; Jong Sam PAIK ; Young H. SOHN ; Jin-Young AHN ; Eungseok OH ; Jinyoung YOUN ; Ji-Young LEE ; Phil Hyu LEE ; Wooyoung JANG ; Han-Joon KIM ; Beom Seok JEON ; Sun Ju CHUNG ; Jin Whan CHO ; Sang-Myung CHEON ; Suk Yun KANG ; Mee Young PARK ; Seongho PARK ; Young Eun HUH ; Seok Jae KANG ; Hee-Tae KIM
Journal of Clinical Neurology 2021;17(3):501-501
9.Validation Study of the Official Korean Version of the Movement Disorder Society-Unified Parkinson’s Disease Rating Scale
Jinse PARK ; Seong-Beom KOH ; Kyum-Yil KWON ; Sang Jin KIM ; Jae Woo KIM ; Joong-Seok KIM ; Kun-Woo PARK ; Jong Sam PAIK ; Young H. SOHN ; Jin-Young AHN ; Eungseok OH ; Jinyoung YOUN ; Ji-Young LEE ; Phil Hyu LEE ; Wooyoung JANG ; Han-Joon KIM ; Beom Seok JEON ; Sun Ju CHUNG ; Jin Whan CHO ; Sang-Myung CHEON ; Suk Yun KANG ; Mee Young PARK ; Seongho PARK ; Young Eun HUH ; Seok Jae KANG ; Hee-Tae KIM
Journal of Clinical Neurology 2021;17(3):501-501
10.Effect of Operator Volume on In-Hospital Outcomes Following Primary Percutaneous Coronary Intervention for ST-Elevation Myocardial Infarction: Based on the 2014 Cohort of Korean Percutaneous Coronary Intervention (K-PCI) Registry
Jung Hee LEE ; Sang Yong EOM ; Ung KIM ; Chan Hee LEE ; Jang Won SON ; Dong Woon JEON ; Jang Ho BAE ; Seok Kyu OH ; Kwang Soo CHA ; Yongsung SUH ; Young Youp KOH ; Tae Hyun YANG ; Dae keun SHIM ; Jang Whan BAE ; Jong Seon PARK
Korean Circulation Journal 2020;50(2):133-144
BACKGROUND AND OBJECTIVES:
The relationship between operator volume and outcomes of percutaneous coronary intervention (PCI) in patients with ST-elevation myocardial infarction (STEMI) has not been fully investigated. We aimed to investigate the relationship between operator PCI volume and in-hospital outcomes after primary PCI for STEMI.
METHODS:
Among the total of 44,967 consecutive cases of PCI enrolled in the Korean nationwide, retrospective registry (K-PCI registry), 8,282 patients treated with PCI for STEMI by 373 operators were analyzed. PCI volumes above the 75th percentile (>30 cases/year), between the 75th and 25th percentile (10–30 cases/year), and below the 25th percentile (<10 cases/year) were defined as high, moderate, and low-volume operators, respectively. In-hospital outcomes including mortality, non-fatal myocardial infarction (MI), stent thrombosis, stroke, and urgent repeat PCI were analyzed.
RESULTS:
The average number of primary PCI cases performed by 373 operators was 22.2 in a year. In-hospital mortality after PCI for STEMI was 571 cases (6.9%). In-hospital outcomes by operator volume showed no significant differences in the death rate, cardiac death, non-fatal MI, and stent thrombosis. However, the rate of urgent repeat PCI tended to be lower in the high-volume operator (0.6%) than in the moderate-(0.7%)/low-(1.5%) volume operator groups (p=0.095). The adjusted odds ratios for adverse in-hospital outcomes were similar in the 3 groups. Multivariate analysis also showed that operator volume was not a predictor for adverse in-hospital outcomes.
CONCLUSIONS
In-hospital outcomes after primary PCI for STEMI were not associated with operator volume in the K-PCI registry.

Result Analysis
Print
Save
E-mail